Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Terminal area automatic navigation, guidance, and control research using the Microwave Landing System (MLS). Part 2: RNAV/MLS transition problems for aircraft

The problems in navigation and guidance encountered by aircraft in the initial transition period in changing from distance measuring equipment, VORTAC, and barometric instruments to the more precise microwave landing system data type navaids in the terminal area are investigated. The effects of the resulting discontinuities on the estimates of position and velocity for both optimal (Kalman type navigation schemes) and fixed gain (complementary type) navigation filters, and the effects of the errors in cross track, track angle, and altitude on the guidance equation and control commands during the critical landing phase are discussed. A method is presented to remove the discontinuities from the navigation loop and to reconstruct an RNAV path designed to land the aircraft with minimal turns and altitude changes.

Pines, S.↗

Estimation of atmospheric moisture content from microwave radiometric measurements during CCOPE

A multiple linear regression technique has been applied to retrieve continuous sequences of atmospheric moisture profiles from a set of measured data. In this method the selection of an optimal subset of sensor channels plays a crucial role, in order to reduce the impact of data noise and redundancy. The data were obtained with a 4-channel remote-sensing microwave instrument carried aboard an aircraft. In contrast, most previously reported moisture profile retrievals from microwave radiometry have been used on simulated, discontinuous data. Although the data were obtained over a land surface with only a limited amount of correlative data, the retrievals were quite successful.

Lambrigtsen, B. H.↗

Hubble Space Telescope - New view of an ancient universe

Scheduled for a March 1990 Shuttle launch, the Hubble Space Telescope (HST) will give astronomers a tool of unprecedented accuracy to observe the universe: an optically superb instrument free of the atmospheric turbulence, distortion, and brightness that plague all earthbound telescopes. The observatory will carry into orbit two cameras, a pair of spectrographs, a photometer, and fine guidance sensors optimized for astrometry. The diffraction limit for the 2.4-m aperture of the HST corresponds to 90 percent of the radiation from a point source falling within a circle of 0.1 arcsec angular radius at a wavelength of 633 nm. The 15-year mission will make observations in the ultraviolet as well as the optical spectral region, thus, widening the wavelength window to a range extending from the Lyman alpha wavelengnth of 122 nm to just about 2 microns. The observational program that awaits the HST will include the study of planetary atmospheres, in particular the search for aerosols; the study of globular star clusters within the Galaxy; and the determination of the present rate of expansion of the universe. The HST will achieve resolutions of 0.1 arcsec consistently, regardless of observation duration. The HST engineering challenge is also discussed.

Leckrone, David S.↗

Application of carbon-powder-polymer composite as a continuous crack-length sensor

This paper explores the application of carbon-powder-impregnated polymeric composites for measuring crack extensions. The strain sensitivity of the gage material is shown to be very small. In the first series of tests, the gage material is characterized by measuring the change in electrical resistance due to machined slits for various gage lengths. The measured responses is compared with the response predicted from a very simple electrical model. On the basis of good correlation and repeatability, the usefulness of such gages to measure crack extensions is assessed by a second series of tests. Further work to improve the gage response by optimizing the shape of the gage and making the gage and the adhesive layer thinner is proposed. The presented concept, with improvements, can result in a reliable, inexpensive crack gage requiring inexpensive instrumentation.

Prabhakaran, R.↗

In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

Glavin, D. P.↗

Shuttle Entry Imaging Using Infrared Thermography

During the Columbia Accident Investigation, imaging teams supporting debris shedding analysis were hampered by poor entry image quality and the general lack of information on optical signatures associated with a nominal Shuttle entry. After the accident, recommendations were made to NASA management to develop and maintain a state-of-the-art imagery database for Shuttle engineering performance assessments and to improve entry imaging capability to support anomaly and contingency analysis during a mission. As a result, the Space Shuttle Program sponsored an observation campaign to qualitatively characterize a nominal Shuttle entry over the widest possible Mach number range. The initial objectives focused on an assessment of capability to identify/resolve debris liberated from the Shuttle during entry, characterization of potential anomalous events associated with RCS jet firings and unusual phenomenon associated with the plasma trail. The aeroheating technical community viewed the Space Shuttle Program sponsored activity as an opportunity to influence the observation objectives and incrementally demonstrate key elements of a quantitative spatially resolved temperature measurement capability over a series of flights. One long-term desire of the Shuttle engineering community is to calibrate boundary layer transition prediction methodologies that are presently part of the Shuttle damage assessment process using flight data provided by a controlled Shuttle flight experiment. Quantitative global imaging may offer a complementary method of data collection to more traditional methods such as surface thermocouples. This paper reviews the process used by the engineering community to influence data collection methods and analysis of global infrared images of the Shuttle obtained during hypersonic entry. Emphasis is placed upon airborne imaging assets sponsored by the Shuttle program during Return to Flight. Visual and IR entry imagery were obtained with available airborne imaging platforms used within DoD along with agency assets developed and optimized for use during Shuttle ascent to demonstrate capability (i.e., tracking, acquisition of multispectral data, spatial resolution) and identify system limitations (i.e., radiance modeling, saturation) using state-of-the-art imaging instrumentation and communication systems. Global infrared intensity data have been transformed to temperature by comparison to Shuttle flight thermocouple data. Reasonable agreement is found between the flight thermography images and numerical prediction. A discussion of lessons learned and potential application to a potential Shuttle boundary layer transition flight test is presented.

Horvath, Thomas↗

Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.

sea surface salinity↗

Second-generation Micro-Spec: Spectrometer Design for the Experiment for Cryogenic Large-Aperture Intensity Mapping

Micro-Spec (μ-Spec) is a direct-detection spectrometer that integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip using superconducting microstrip transmission lines on a single-crystal silicon substrate. The second-generation μ-Spec has been designed to operate with a spectral resolution of ∼512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA’s EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM will be a high-altitude balloon mission that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5. EXCLAIM will be the first demonstration of the μ-Spec technology in a space-like environment. This work reviews the status of the μ-Spec design for the EXCLAIM instrument, with emphasis on the spectrometer’s two-dimensional diffractive region, through which light of different wavelengths is focused on microwave kinetic inductance detectors (MKIDs) along the spectrometer focal plane. An optimization process generates a geometrical configuration of the diffractive region that satisfies specific requirements on size, operating spectral range and performance. An initial optical design optimized for EXCLAIM is presented in terms of geometric layout, spectral purity and efficiency.

Giuseppe Cataldo↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Flexural Fillet Geometry Optimization for Design of Force Transducers Used in Aeronautics Testing

Force transducer designs used in the ground testing aeronautics community have seen minimal change over the last few decades. With increased focus on data quality and long-term performance capabilities over the life of these instruments, it is critical to investigate new methods that improve these designs. One area of focus in the past few years at NASA has been on the design of the flexural elements of traditional force balance transducers. Many of the heritage balances that have been heavily used over the last few decades have started to develop fatigue cracks. The recent focus on the flexural design of traditional single-piece force balances revolves around the design of these elements such that stress concentrations are minimized, with the overall goal of increasing the fatigue life of the balance. Recent research in the area of using conic shaped fillets in the highly stressed regions of traditional force balances will be discussed, with preliminary numerical and experimental data results. A case study will be presented which discusses integration of this knowledge into a new high-capacity semi-span force balance.

Lynn, Keith C.↗

Flight instrument and telemetry response and its inversion

Mathematical models of rate gyros, servo accelerometers, pressure transducers, and telemetry systems were derived and their parameters were obtained from laboratory tests. Analog computer simulations were used extensively for verification of the validity for fast and large input signals. An optimal inversion method was derived to reconstruct input signals from noisy output signals and a computer program was prepared.

Weinberger, M. R.↗

Statistical Classification of Biosignature Information using Multiple Instrument Observations

The accurate identification of biosignatures (indications of life) from data taken from remote or in situ planetary exploration is one of the most important challenges in astrobiology, the interdisciplinary field examining habitability and the potential for extraterrestrial life. This study employs machine learning algorithms to optimize the identification of biosignatures, with an emphasis on those which are agnostic to a specific biochemical basis. We exploit the wealth of terrestrial data available from biogenic and abiogenic systems to enhance efficient feature prioritization. Our dataset, pulled from public databases and laboratory recorded measurements, includes elemental abundance, isotopic fractionation, and VNIR/Raman spectra The data curation process included standardization for detection limits and ranges. Subsequent feature extraction yielded detailed inputs for machine learning, including combinations of elemental content, isotopic ratios, and parameters of spectral peaks and troughs. Feature significance was evaluated across diverse machine learning methodologies, such as k-nearest neighbors, logistic regression, Random Forest, support vector machines, and Gaussian Naïve Bayes, along with a combined voting classifier. We utilized Receiver Operating Characteristic Area Under the Curve (ROC AUC) across 2,000 50% test-train splits as a robust metric of model performance. Results revealed a promising ROC AUC of 0.853 for the combined voting classifier. Removing elemental abundance data notably reduced model accuracy (13% decrease in AUC), highlighting its critical role in biosignature detection. Several other individual data features exhibited significance within their respective data types, offering additional granularity. This research fortifies the relevance of machine learning to astrobiology, potentially enhancing life detection missions by allowing algorithmic prioritization of high-interest samples for further investigation. Future work will refine data standardization, expand the dataset to include more terrestrial systems, and incorporate convolutional neural networks for spectral feature extraction. The potential for public data sharing is also under exploration, reinforcing our commitment to collective scientific advancement.

Statistical↗

Measurement of the characteristic X ray of oxygen and other ultrasoft X rays using mercuric iodide detectors

This letter reports the detection and resolution of the characteristic X-ray of oxygen at 523 eV and other ultrasoft X-rays (photons energy less than 1 keV) using radiation detectors fabricated from the compound semi-insulator mercuric iodide (HgI2). These detectors are capable of operation at room ambient but in these experiments were slightly cooled using a Peltier element to 0 C. A pulsed light feedback preamplifier with a Peltier element cooled (to -30 deg) first stage field-effect transistor was used to amplify signals from the detector. Overall system noise level was 185 eV (full width at half-maximum) limited by the temperature of the first stage field-effect transistor. With optimal cooling of this element the characteristic X-ray of carbon at 282 eV should be measurable. These results would seem to be important in measurement of biological samples in electron column instruments.

Iwanczyk, J. S.↗

Preliminary results from the MAMA detectors for the SOHO mission

Multi-Anode Microchannel Array (MAMA) detector systems are being fabricated and tested for use in the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) and the Ultraviolet Coronagraph Spectrometer (UVCS) instruments on the ESA/NASA Solar and Heliospheric Observatory (SOHO) mission. The SOHO MAMA detector systems have formats of 360 x 1024 pixels and pixel dimensions of 25 x 25 sq microns and are optimized for operation at Extreme Ultraviolet (EUV) wavelengths between 40 and 160 nm. In this paper we report on the initial results of measurements of the performance characteristics of the first flight-configuration detector system employing the new custom Application Specific Integrated Circuits (ASICs) which are designed to improve both the dynamic range and the uniformity of response. The performance characteristics of this detector system are compared with those of earlier breadboard systems employing discrete-component electronics circuits.

Slater, David C.↗

Aviation System Capacity Program Terminal Area Productivity Project: Ground and Airborne Technologies

Ground and airborne technologies were developed in the Terminal Area Productivity (TAP) project for increasing throughput at major airports by safely maintaining good-weather operating capacity during bad weather. Methods were demonstrated for accurately predicting vortices to prevent wake-turbulence encounters and to reduce in-trail separation requirements for aircraft approaching the same runway for landing. Technology was demonstrated that safely enabled independent simultaneous approaches in poor weather conditions to parallel runways spaced less than 3,400 ft apart. Guidance, control, and situation-awareness systems were developed to reduce congestion in airport surface operations resulting from the increased throughput, particularly during night and instrument meteorological conditions (IMC). These systems decreased runway occupancy time by safely and smoothly decelerating the aircraft, increasing taxi speed, and safely steering the aircraft off the runway. Simulations were performed in which optimal trajectories were determined by air traffic control (ATC) and communicated to flight crews by means of Center TRACON Automation System/Flight Management System (CTASFMS) automation to reduce flight delays, increase throughput, and ensure flight safety.

Giulianetti, Demo J.↗

Laboratory Performance of the Shaped Pupil Coronagraphic Architecture for the WFIRST-AFTA Coronagraph

One of the two primary architectures being tested for the WFIRST-AFTA coronagraph instrument is the shaped pupil coronagraph, which uses a binary aperture in a pupil plane to create localized regions of high contrast in a subsequent focal plane. The aperture shapes are determined by optimization, and can be designed to work in the presence of secondary obscurations and spiders-an important consideration for coronagraphy with WFIRSTAFTA. We present the current performance of the shaped pupil testbed, including the results of AFTA Milestone 2, in which approximately 6 × 10(exp −9) contrast was achieved in three independent runs starting from a neutral setting.

Cady, Eric↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combustor Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Combustor Noise↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combuster Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Turbomachinery Noise↗