Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Improving the precision of astrometry for space debris

The data reduction method for optical space debris observations has many similarities with the one adopted for surveying near-Earth objects; however, due to several specific issues, the image degradation is particularly critical, which makes it difficult to obtain precise astrometry. An automatic image reconstruction method was developed to improve the astrometry precision for space debris, based on the mathematical morphology operator. Variable structural elements along multiple directions are adopted for image transformation, and then all the resultant images are stacked to obtain a final result. To investigate its efficiency, trial observations are made with Global Positioning System satellites and the astrometry accuracy improvement is obtained by comparison with the reference positions. The results of our experiments indicate that the influence of degradation in astrometric CCD images is reduced, and the position accuracy of both objects and stellar stars is improved distinctly. Our technique will contribute significantly to optical data reduction and high-order precision astrometry for space debris.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-shot Femtosecond X-Ray Holography Using Extended References

In the context of x-ray lensless imaging, we present a recent approach for Fourier transform holography based on the use of extended references. Major advances shown here rely on a high signal efficiency and on the direct image reconstruction of the object performed by a simple linear derivative. Moreover, the extended holographic reference is easy to manufacture and can be applied to a variety of imaging experiments. Here we demonstrate single-shot imaging with a table-top, laser-based coherent soft x-ray source. A spatial resolution of 110 nm was obtained with an integration time of 20 fs.

07 ISOTOPE AND RADIATION SOURCES↗

Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe

A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 µm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ∼1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.

42 ENGINEERING↗

Magnetospheric Radio Tomography: Observables, Algorithms, and Experimental Analysis

This grant supported research towards developing magnetospheric electron density and magnetic field remote sensing techniques via multistatic radio propagation and tomographic image reconstruction. This work was motivated by the need to better develop the basic technique of magnetospheric radio tomography, which holds substantial promise as a technology uniquely capable of imaging magnetic field and electron density in the magnetosphere on large scales with rapid cadence. Such images would provide an unprecedented and needed view into magnetospheric processes. By highlighting the systems-level interconnectedness of different regions, our understanding of space weather processes and ability to predict them would be dramatically enhanced. Three peer-reviewed publications and 5 conference presentations have resulted from this work, which supported 1 PhD student and 1 postdoctoral researcher. One more paper is in progress and will be submitted shortly. Because the main results of this research have been published or are soon to be published in refereed journal articles listed in the reference section of this document, we provide here an overview of the research and accomplishments without describing all of the details that are contained in the articles.

Cummer, Steven↗

Free-moving Quantitative Gamma-ray Imaging

The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dependent detector position and orientation data, a digitized representation of the surrounding 3D environment, and appropriate image reconstruction and uncertainty quantification methods. We have previously demonstrated 3D mapping of gamma-ray emitters with free-moving detector systems on a relative intensity scale using a technique called Scene Data Fusion (SDF). Here we characterize the detector response of a multi-element gamma-ray imaging system using experimentally benchmarked Monte Carlo simulations and perform 3D mapping on an absolute intensity scale. We present experimental reconstruction results from hand-carried and airborne measurements with point-like and distributed sources in known configurations, demonstrating quantitative SDF in complex 3D environments.

47 OTHER INSTRUMENTATION↗

Evidence procedure for efficient quantum-state tomography

I show that in tomographic experiments, the measurement of a small set of observables suffices to confirm or incrementally amend prior expectations with a high degree of confidence. To this end, I adapt the evidence procedure, an estimation technique used in classical image reconstruction, for use in quantum-state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photosensor aperture shaping to reduce aliasing in optical-mechanical line-scan imaging systems.

Review of optical-mechanical scanning techniques that are generally employed in instruments specifically designed to characterize variations in scene brightness spectrally or radiometrically. Special attention is given to the effect of aliasing on the spatial detail of the reconstructed image. Aliasing may be caused by linescan sampling and can, in turn, severely degrade images that emphasize the spatial characterization of a scene. Photosensor aperture shaping and line-scan spacing are investigated as means for reducing this degradation.

Katzberg, S. J.↗

Calibration method of tilt and azimuth angles for alignment of TEM tomographic tilt series

This paper describes the calibration method of the tilt and azimuth angles of specimen using a digital protractor and a laser autocollimator for alignment of electron tomography. It also suggests an easy method to check whether the specimen is tilted by 180.0 deg., and whether the azimuth angle is 0.0 deg.; the method involves the use of two images of a rod-shaped specimen collected before and after a 180.0 deg. The method is based on the assumption that these images are symmetric about the tilt axis when the azimuth angle is 0.0 deg. In addition, we used an experiment to demonstrate the effect of the incorrect angles on reconstructed images and simulated the image quality against distance away from tilt axis.

43 PARTICLE ACCELERATORS↗

A novel approach to assess the treatment response using Gaussian random field in PET

Purpose: The assessment of early therapeutic response to anticancer therapy is vital for treatment planning and patient management in clinic. With the development of personal treatment plan, the early treatment response, especially before any anatomically apparent changes after treatment, becomes urgent need in clinic. Positron emission tomography (PET) imaging serves an important role in clinical oncology for tumor detection, staging, and therapy response assessment. Many studies on therapy response involve interpretation of differences between two PET images, usually in terms of standardized uptake values (SUVs). However, the quantitative accuracy of this measurement is limited. This work proposes a statistically robust approach for therapy response assessment based on Gaussian random field (GRF) to provide a statistically more meaningful scale to evaluate therapy effects. Methods: The authors propose a new criterion for therapeutic assessment by incorporating image noise into traditional SUV method. An analytical method based on the approximate expressions of the Fisher information matrix was applied to model the variance of individual pixels in reconstructed images. A zero mean unit variance GRF under the null hypothesis (no response to therapy) was obtained by normalizing each pixel of the post-therapy image with the mean and standard deviation of the pretherapy image. The performance of the proposed method was evaluated by Monte Carlo simulation, where XCAT phantoms (128{sup 2} pixels) with lesions of various diameters (2–6 mm), multiple tumor-to-background contrasts (3–10), and different changes in intensity (6.25%–30%) were used. The receiver operating characteristic curves and the corresponding areas under the curve were computed for both the proposed method and the traditional methods whose figure of merit is the percentage change of SUVs. The formula for the false positive rate (FPR) estimation was developed for the proposed therapy response assessment utilizing local average method based on random field. The accuracy of the estimation was validated in terms of Euler distance and correlation coefficient. Results: It is shown that the performance of therapy response assessment is significantly improved by the introduction of variance with a higher area under the curve (97.3%) than SUVmean (91.4%) and SUVmax (82.0%). In addition, the FPR estimation serves as a good prediction for the specificity of the proposed method, consistent with simulation outcome with ∼1 correlation coefficient. Conclusions: In this work, the authors developed a method to evaluate therapy response from PET images, which were modeled as Gaussian random field. The digital phantom simulations demonstrated that the proposed method achieved a large reduction in statistical variability through incorporating knowledge of the variance of the original Gaussian random field. The proposed method has the potential to enable prediction of early treatment response and shows promise for application to clinical practice. In future work, the authors will report on the robustness of the estimation theory for application to clinical practice of therapy response evaluation, which pertains to binary discrimination tasks at a fixed location in the image such as detection of small and weak lesion.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sprectroscopic and time-resolved optical methods and apparatus for imaging objects in turbed media

Method and apparatus for imaging objects in turbid media. In one embodiment, the method comprises illuminating at least a portion of the turbid medium with substantially monochromatic light of at least two wavelengths in the 600-1500 nm spectral range. A first of the at least two wavelengths is equal to a resonance wavelength for an optical property of an object in the illuminated portion of the turbid medium but is not equal to a resonance wavelength for the turbid medium. A second of the at least two wavelengths is not equal to a resonance wavelength for either the object or the turbid medium. Light emergent from the turbid medium following each of the foregoing illuminations comprises a ballistic component, a snake component and a diffuse component. A direct shadowgram image may be obtained by preferentially passing from the emergent light, following each illumination. the ballistic and snake components thereof and detecting the preferentially passed light. Alternatively, an inverse reconstruction image may be obtained by determining, following each illumination, the intensity of the diffuse component at a plurality of points in time and then using these pluralities of intensity determinations and a mathematical inversion algorithm to form an image of the object in the turbid medium. An image of the object with higher contrast and better quality may be obtained by using the ratio or difference of the images recorded with resonant light and non-resonant light.

Alfano, Robert R.↗

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗

An investigative study of multispectral data compression for remotely-sensed images using vector quantization and difference-mapped shift-coding

A study is conducted to investigate the effects and advantages of data compression techniques on multispectral imagery data acquired by NASA's airborne scanners at the Stennis Space Center. The first technique used was vector quantization. The vector is defined in the multispectral imagery context as an array of pixels from the same location from each channel. The error obtained in substituting the reconstructed images for the original set is compared for different compression ratios. Also, the eigenvalues of the covariance matrix obtained from the reconstructed data set are compared with the eigenvalues of the original set. The effects of varying the size of the vector codebook on the quality of the compression and on subsequent classification are also presented. The output data from the Vector Quantization algorithm was further compressed by a lossless technique called Difference-mapped Shift-extended Huffman coding. The overall compression for 7 channels of data acquired by the Calibrated Airborne Multispectral Scanner (CAMS), with an RMS error of 15.8 pixels was 195:1 (0.41 bpp) and with an RMS error of 3.6 pixels was 18:1 (.447 bpp). The algorithms were implemented in software and interfaced with the help of dedicated image processing boards to an 80386 PC compatible computer. Modules were developed for the task of image compression and image analysis. Also, supporting software to perform image processing for visual display and interpretation of the compressed/classified images was developed.

Jaggi, S.↗

Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT

In dual-source dual-energy CT, the images reconstructed from the low- and high-energy scans (typically at 80 and 140 kV, respectively) can be mixed together to provide a single set of non-material-specific images for the purpose of routine diagnostic interpretation. Different from the material-specific information that may be obtained from the dual-energy scan data, the mixed images are created with the purpose of providing the interpreting physician a single set of images that have an appearance similar to that in single-energy images acquired at the same total radiation dose. In this work, the authors used a phantom study to evaluate the image quality of linearly mixed images in comparison to single-energy CT images, assuming the same total radiation dose and taking into account the effect of patient size and the dose partitioning between the low-and high-energy scans. The authors first developed a method to optimize the quality of the linearly mixed images such that the single-energy image quality was compared to the best-case image quality of the dual-energy mixed images. Compared to 80 kV single-energy images for the same radiation dose, the iodine CNR in dual-energy mixed images was worse for smaller phantom sizes. However, similar noise and similar or improved iodine CNR relative to 120 kV images could be achieved for dual-energy mixed images using the same total radiation dose over a wide range of patient sizes (up to 45 cm lateral thorax dimension). Thus, for adult CT practices, which primarily use 120 kV scanning, the use of dual-energy CT for the purpose of material-specific imaging can also produce a set of non-material-specific images for routine diagnostic interpretation that are of similar or improved quality relative to single-energy 120 kV scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cohesive phase-field chemo-mechanical simulations of inter- and trans- granular fractures in polycrystalline NMC cathodes via image-based 3D reconstruction

The optimal design and durable utilization of lithium-ion batteries necessitates an objective modeling approach to understand fracture and failure mechanisms. This paper presents a comprehensive chemo-mechanical modeling study focused on elucidating fracture-induced damage and degradation phenomena in the polycrystalline Li $\mathcal{x}$ Ni 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) cathode. An innovative approach that utilizes image-based reconstructed 3D geometry as finite element (FE) mesh input is employed to enhance the precision in capturing the convoluted architecture and morphological features. For accurately representing the intricate crack configurations within the polycrystalline system, we adopted the cohesive phase-field fracture (CPF) model. Through the integration of advanced image-based geometry reconstruction technique and the promising CPF modeling approach, lithium (de)intercalation induced crack evolution (e.g., nucleation, propagation, branching and diverse modes including inter-/trans-(intra-) granular patterns) and the resulting chemical degradation can be precisely captured, which is also compared and validated with numerical predictions using a continuum damage model. In particular, this model predicts fracture induced degradation under varying fracture properties of grain boundaries and charging rates; the conclusion that NMC particles comprised of larger grains are predicted to have less degradation than those with smaller grains can also be drawn. This comprehensive analysis provides valuable insights into the fracture and degradation within polycrystalline NMC cathodes.

25 ENERGY STORAGE↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ERTS image data compression technique evaluation

The background and results of an investigation concerning the use of multispectral data compression in the ERTS program are presented. An average compression of greater than 2:1 has been achieved under the constraint of zero distortion in the reconstructed image, and four MSS tapes can be compressed to fill less than one reel of magnetic tape. A preliminary study of the hardware implementation of this processor proves the feasability of compression at input bit rates of over 100Mbs.

May, C. L.↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

MO-FG-CAMPUS-IeP2-05: Feasibility Demonstration of High-Voltage Clinical CT and Impact On X-Ray Penetration Through Metal Objects

Purpose: To demonstrate the possibility and quantify the impact of operating a clinical CT scanner at exceptionally high x-ray tube voltage for better penetration through metal objects and facilitating metal artifact reduction. Methods: We categorize metal objects according to the data corruption severeness (level of distortion and complete photon starvation fraction). To demonstrate feasibility and investigate the impact of high voltage scanning we modified a commercial GE LightSpeed VCT scanner (generator and software) to enable CT scans with x-ray tube voltages as high as 175 kVp. A 20 cm diameter water phantom with two metal rods (10 mm stainless and 25 mm titanium) and a water phantom with realistic metal object (spine cage) were used to evaluate the data corruption and image artifacts in the absence of any algorithm correction. We also performed simulations to confirm our understanding of the transmitted photon levels through metal objects with different size and composition. Results: The reconstructed images at 175 kVp still have significant dark shading artifacts, as expected since no special scatter correction or beam hardening was performed but show substantially lower noise and photon starvation than at lower kVp due to better beam penetration. Analysis of the raw data shows that the photon starved data is reduced from over 4% at 140 kVp to below 0.2% at 175 kVp. The simulations indicate that for clinically relevant titanium and stainless objects a 175 kVp tube voltage effectively avoids photon starvation. Conclusion: The use of exceptionally high tube voltage on a clinical CT system is a practical and effective solution to avoid photon starvation caused by certain metal implants. Sparse and hybrid high-voltage protocols are being considered to maintain low patient dose. This opens the door to algorithmic physics-based corrections rather than treating the data as missing and relying on missing data algorithms. Some of the authors are employees of General Electric.

60 APPLIED LIFE SCIENCES↗