Intracavitary in vivo dosimetry based on multichannel fiber-coupled radioluminescence and optically stimulated luminescence of Al{sub 2}O{sub 3}:C

Fiber Optic Dosimetric Catheters (FODCs) composed of chains of alumina crystals are investigated by the CEA LIST within the French ANR-INTRADOSE Project in the purpose of intracavitary in vivo dosimetry (IVD) during Brachytherapy (BT) with iridium sources and Intensity-Modulated Radiation Therapy (IMRT) with linear accelerators. A dedicated process involving PMMA fibers, cast altogether forming hexagonal bundle, is demonstrated. Optically Stimulated Luminescence (OSL) signals are recorded on-line after irradiation and absorbed doses are compared to planned dose distribution. Real-time dose measurements may also be performed by recording the Radioluminescence (RL), spontaneously emitted by the crystals during irradiation. In this case, a correction method is implemented to correct for stem effect influence (Cerenkov and scintillation generated within the fibers). For BT, the dual-fiber subtraction method is used (using a reference fiber) whereas the time discrimination method is used for IMRT. The experimental dose distribution leads to an underestimation of the source-sensor distance presumably due to energy dependence of the alumina crystal at low photon energy. At the time being, Monte-Carlo modeling of the FODC is performed with the aim to estimate this energy dependence and finally correct for it. Finally, metrological and preclinical validations are still running at Centre Leon Berard (Lyon (France)) in the purpose of checking the compliance of the FODC prototypes with treatment specifications and medical constraints. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and Measurements for Mitigating Interface from Skyshine

Skyshine, the radiation scattered in the air above a high-activity gamma-ray source, can produce interference with radiation portal monitor (RPM) systems at distances up to even many hundred meters. Pacific Northwest National Laboratory (PNNL) has been engaged in a campaign of measurements, design work and modeling that explore methods of mitigating the effects of skyshine on outdoor measurements with sensitive instruments. An overview of our work with shielding of skyshine is being reported by us in another paper at this conference. This paper will concentrate on two topics: measurements and modeling with Monte Carlo transport calculations to characterize skyshine from an iridium-192 source, and testing of a prototype louver system, designed and fabricated at PNNL, as a shielding approach to limit the impact of skyshine interference on RPM systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recommended values of clean metal surface work functions

A critical review of the experimental literature for measurements of the work functions of clean metal surfaces of single-crystals is presented. The tables presented include all results found for low-index crystal faces except cases that were known to be contaminated surfaces. These results are used to construct a recommended value of the work function for each surface examined, along with an uncertainty estimate for that value. The uncertainties are based in part on the error distribution for all measured work functions in the literature, which is included here. The metals included in this review are silver (Ag), aluminum (Al), gold (Au), copper (Cu), iron (Fe), iridium (Ir), molybdenum (Mo), niobium (Nb), nickel (Ni), palladium (Pd), platinum (Pt), rhodium (Rh), ruthenium (Ru), tantalum (Ta), and tungsten (W)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heteroleptic cyclometalated Ir(III) complexes with charge transporting groups: A theoretical study

Efficient and stable high energy organic light emitting devices (OLEDs) are a vital component of new generation general illumination solutions. However, large charge imbalances in the emissive layer of OLEDs lead to charge accumulation and subsequent side reactions which lowers the device efficiency and dramatically shortens operational lifetime. Radical changes in the way emitter materials are designed are needed to address this problem. Conventional approaches have only focused on color tuning; however, multi-functional emitter materials are needed to assist the transport of charge in the emissive layer. We propose to design and synthesize new organometallic iridium phosphorescent materials with bipolar charge transport properties to be used in high energy OLEDs and white light configurations

Organic light emitting devices, rational design, o↗

The use of directional interstitial sources to improve dosimetry in breast brachytherapy

The purposes of this study were to investigate the feasibility of improving dosimetry with temporary low-dose-rate (LDR) multicatheter breast implants using directional {sup 125}I (iodine) interstitial sources and to provide a comparison of a patient treatment plan to that achieved by conventional high-dose-rate (HDR) interstitial breast brachytherapy. A novel {sup 125}I source emitting radiation in a specified direction has been developed. The directional sources contain an internal radiation shield that greatly reduces the intensity of radiation in the shielded direction. The sources have a similar dose distribution to conventional nondirectional sources on the unshielded side. The treatment plan for a patient treated with HDR interstitial brachytherapy with {sup 192}Ir (iridium) was compared with a directional {sup 125}I treatment plan using the same data set. Several dosimetric parameters are compared including target volume coverage, volume receiving 50%, 100%, and 150% of the prescription dose (V50, V100, and V150, respectively), dose homogeneity index (DHI), and the skin surface areas receiving 30%, 50%, and 80% of the prescription dose (S30, S50, and S80, respectively). The HDR and LDR prescription doses were 34 Gy in ten fractions delivered over five days and 45 Gy in 108 h, respectively. Similar and excellent target volume coverage was achieved by both directional LDR and HDR plans (99.2% and 97.5%, respectively). For a 170 cm{sup 3} target volume, the dosimetric parameters were similar for LDR and HDR: DHI was 0.82 in both cases, V100 was 214.4 cm{sup 3} and 225.7 cm{sup 3}, and V150 was 39.1 cm{sup 3} and 40.4 cm{sup 3}, respectively. However, with directional LDR, significant reductions in skin dose were achieved: S30 was reduced from 100.6 to 62.5 cm{sup 2}, S50 from 50.6 to 16.1 cm{sup 2}, and S80 from 2 cm{sup 2} to zero. The reduction in V50 for the whole breast was more than 100 cm{sup 3} (386.1 cm{sup 3} for LDR versus 489.2 cm{sup 3} for HDR). In this case study, compared with HDR, directional interstitial LDR {sup 125}I sources allow similar dose coverage to the subcutaneous target volume while lowering the skin dose due to a more conformal dose distribution and quicker falloff beyond the target. The improved dose distribution provided by directional interstitial brachytherapy might enable partial breast treatment to tumors closer to the skin or chest wall or in relatively small breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An absorbed dose to water standard for HDR {sup 192}Ir brachytherapy sources based on water calorimetry: Numerical and experimental proof-of-principle

Water calorimetry is an established technique for absorbed dose to water measurements in external beams. In this paper, the feasibility of direct absorbed dose measurements for high dose rate (HDR) iridium-192 ({sup 192}Ir) sources using water calorimetry is established. Feasibility is determined primarily by a balance between the need to obtain sufficient signal to perform a reproducible measurement, the effect of heat loss on the measured signal, and the positioning uncertainty affecting the source-detector distance. The heat conduction pattern generated in water by the Nucletron microSelectron-HDR {sup 192}Ir brachytherapy source was simulated using COMSOL MULTIPHYSICSTM software. Source heating due to radiation self-absorption was calculated using EGSnrcMP. A heat-loss correction k{sub c} was calculated as the ratio of the temperature rise under ideal conditions to temperature rise under realistic conditions. The calorimeter setup used a parallel-plate calorimeter vessel of 79 mm diameter and 1.12 mm thick front and rear glass windows located 24 mm apart. Absorbed dose was measured with two sources with nominal air kerma strengths of 38 000 and 21 000 U, at source-detector separations ranging from 24.7 to 27.6 mm and irradiation times of 36.0 to 80.0 s. The preliminary measured dose rate per unit air kerma strength of (0.502{+-}0.007) {mu}Gy/(s U) compares well with the TG-43 derived 0.505 {mu}Gy/(s U). This work shows that combined dose uncertainties of significantly less than 5% can be achieved with only modest modifications of current water calorimetry techniques and instruments. This work forms the basis of a potential future absolute dose to water standard for HDR {sup 192}Ir brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope

By providing superior localization and immobilization, stereotactic radiosurgery (SRS) is capable of delivering millimeter spheres of dose to intracranial targets with submillimeter precision. Several authors have proposed new SRS solutions to dramatically reduce beam penumbra to hundreds of microns. These solutions require new quality assurance methods capable of penumbra measurement at the micron scale. This article examines the capability of a digital microscope, with translation stage and associated software, to resolve dose gradients in Gafchromic EBT film at this level. To produce very steep penumbra, films were irradiated in phantom beneath pinhole collimators using lower energy x rays (100 kVp, 300 kVp, and Iridium-192) and minimal geometric penumbra contribution. For film analysis, a method was developed which improved the signal to noise ratio by finding the center of the irradiation spot, generating several radial dose profiles and averaging these to obtain the final off-axis dose profile. Optical density was converted to dose using a calibration curve. The experimentally determined off-axis dose profiles were compared with MCNP Monte Carlo simulations which replicated the irradiation geometry and served to validate our measured data. The measured 80%-20% penumbral widths were 46 {mu}m{+-}26 {mu}m (100 kVp, 2 mm field size), 69 {mu}m{+-}27 {mu}m (300 kVp, 2 mm field size), and 241 {mu}m{+-}31 {mu}m (Ir-192, 1 mm field size). These penumbral widths agreed with Monte Carlo simulations within experimental uncertainty. Our findings suggest that reading Gafchromic EBT films using a digital microscope with translation stage is suitable for the quality assurance of very sharp penumbra able to resolve gradients to within at least 30 {mu}m.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochromic film dosimetry of HDR {sup 192}Ir source radiation fields

Purpose: A radiochromic film based dosimetry system for high dose rate (HDR) Iridium-192 brachytherapy source was described. A comparison between calibration curves established in water and Solid Water was provided. Methods: Pieces of EBT-2 model GAFCHROMIC film were irradiated in both water and Solid Water with HDR {sup 192}Ir brachytherapy source in a dose range from 0 to 50 Gy. Responses of EBT-2 GAFCHROMIC film were compared for irradiations in water and Solid Water by scaling the dose between media through Monte Carlo calculated conversion factor for both setups. To decrease uncertainty in dose delivery due to positioning of the film piece with respect to the radiation source, traceable calibration irradiations were performed in a parallel-opposed beam setup. Results: The EBT-2 GAFCHROMIC film based dosimetry system described in this work can provide an overall one-sigma dose uncertainty of 4.12% for doses above 1 Gy. The ratio of dose delivered to the sensitive layer of the film in water to the dose delivered to the sensitive layer of the film in Solid Water was calculated using Monte Carlo simulations to be 0.9941 {+-} 0.0007. Conclusions: A radiochromic film based dosimetry system using only the green color channel of a flatbed document scanner showed superior precision if used alone in a dose range that extends up to 50 Gy, which greatly decreases the complexity of work. In addition, Solid Water material was shown to be a viable alternative to water in performing radiochromic film based dosimetry with HDR {sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-P-24: Radiological Disperse Device

Purpose: We are now living in a society of constant fear of terrorism. This topic is pertaining to give a general knowledge of what is a radiological dispersion device or RDD and in case of its detonation, what are the options open to public for a safe action in terms of reducing the exposure and knowing the proper steps. These RDD are also called dirty bombs. Methods: Compared to nuclear weapons, dirty bombs are easy to make. In order for a terrorist organization to construct and detonate a dirty bomb, it must acquire radioactive material by stealing it or buying it through legal or illegal channels. Possible RDD material could come from the millions of radioactive sources used in the industry, for medical purposes and in academic applications mainly for researches. These are, americium-{sup 241}, californium-{sup 252}, caesium-{sup 137}, cobalt-{sup 60}, iridium-{sup 192}, plutonium-{sup 238}, polonium-{sup 210}, radium-{sup 226} and strontium-{sup 90}. Results: Prompt detection of the type of radioactive material used will greatly assist advising people on the protective measures, like sheltering in place, or quickly leaving the immediate area. The effects of radiation are determined by:°the amount of radiation absorbed by body°the type of radiation °the distance from the radiation to an individual°the means of exposure absorbed by the skin, inhaled, or ingested; and length of time exposed. Conclusion: In any facility it is now much more important to keep a log list of all radioactive materials in use. In case there is a dirty bomb explosion, the chaos and economic cost could be enormous. The economic cost for the evaluation of the contamination, survey of people and surroundings and the after treatment, decontamination cost and effort will be a big challenge in any country. So awareness and preparation is the start to face this new type of challenge.

61 RADIATION PROTECTION AND DOSIMETRY↗

Features of photoinduced magnetism in some yttrium–iron-garnet single crystals

Photoinduced magnetic phenomena are considered in yttrium–iron single-crystalline garnets grown from a BaO–B{sub 2}O{sub 3} molten solution with the addition of iridium to the initial melt. The features of the composition and defects of the crystal structure of the samples in the surface layer are determined. In view of this, explanations for features of the photoinduced magnetic phenomena in the investigated crystals are proposed. The determining role of oxygen anions for the photoinduced magnetic phenomena at room temperature is highlighted, and the possible role of a variation in the dopant content and composition is considered.

36 MATERIALS SCIENCE↗

High temperature Ir segregation in Ir-B ceramics: Effect of oxygen presence on stability of IrB 2 and other Ir-B phases

The formation of IrB 2 , IrB 1.35 , IrB 1.1 and IrB monoboride phases in the Ir–B ceramic nanopowder was confirmed during mechanochemical reaction between metallic Ir and elemental B powders. The Ir–B phases were analysed after 90 h of high energy ball milling and after annealing of the powder for 72 h at 1050°C in vacuo . The iridium monoboride (IrB) orthorhombic phase was synthesised experimentally for the first time and identified by powder X-ray diffraction. Additionally, the ReB 2 type IrB 2 hexagonal phase was also produced for the first time and identified by high resolution transmission electron microscope. Ir segregation along disordered domains of the boron lattice was found to occur during high temperature annealing. Furthermore, these nanodomains may have useful catalytic properties.

36 MATERIALS SCIENCE↗

CATALYSTS NHI Thermochemical Systems FY 2009 Year-End Report

Fiscal Year 2009 work in the Catalysts project focused on advanced catalysts for the decomposition of sulfuric acid, a reaction common to both the Sulfur-Iodine (S-I) cycle and the Hybrid Sulfur cycle. Prior years’ effort in this project has found that although platinum supported on titanium oxide will be an acceptable catalyst for sulfuric acid decomposition in the integrated laboratory scale (ILS) project, the material has short comings, including significant cost and high deactivation rates due to sintering and platinum evaporation. For pilot and larger scale systems, the catalyst stability needs to be improved significantly. In Fiscal Year 2008 it was found that at atmospheric pressure, deactivation rates of a 1 wt% platinum catalyst could be reduced by 300% by adding either 0.3 wt% iridium (Ir) or 0.3 wt% ruthenium (Ru) to the catalyst. In Fiscal Year 2009, work focused on examining the platinum group metal catalysts activity and stability at elevated pressures. In addition, simple and complex metal oxides are known to catalyze the sulfuric acid decomposition reaction. These metal oxides could offer activities comparable to platinum but at significantly reduced cost. Thus a second focus for Fiscal Year 2009 was to explore metal oxide catalysts for the sulfuric acid decomposition reaction. In Fiscal Year 2007 several commercial activated carbons had been identified for the HI decomposition reaction; a reaction specific to the S-I cycle. Those materials should be acceptable for the pilot scale project. The activated carbon catalysts have some disadvantages including low activity at the lower range of reactor operating temperature (350 to 400°C) and a propensity to generate carbon monoxide in the presence of water that could contaminate the hydrogen product, but due to limited funding, this area had low priority in Fiscal Year 2009. Fiscal Year 2009 catalyst work included five tasks: development, and testing of stabilized platinum based H2SO4 catalysts, development and testing of metal oxide based H2SO4 catalysts, support of the ILS for catalyst studies, conducting a long term catalyst stability test at anticipated operating temperatures and pressures, and developing capabilities for conducting pressurized catalyst tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER-163 Post-Experiment MCNP Calculations (U)

IER-163 has been modeled with high fidelity in MCNP6. The model k eff was high, as in other similar calculations. The fission ratio 238 U(n,f)/ 235 U(n,f) was 12.6% too small compared with measurements; the ratio 239 Pu(n,f)/ 235 U(n,f) was 11.5% too small compared with measurements; the iridium ratio 193 Ir(n,n´)/ 191 Ir(n,γ) was 16.4% too large; and the gold ratios 197 Au(n,2n)/ 197 Au(n,γ), 197 Au(n,2n)/ 235 U(n,f), and 197 Au(n,γ)/ 235 U(n,f) were within one standard deviation of the measured values. It is suggested that the calculated 235 U fission rate is too large and the calculated 238 U fission rate is too small.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Letter Report on 500 nA Pulsed Current from Field Ionization Source

We recently produced a milestone 500 nA of pulsed current using 40 Ir field ionizer electrodes in our ion source. In conclusion, we have produced the milestone pulsed current of 500 nA using 40 electrochemically etched iridium tips in a field ionization source. The pulsed current output is repeatable and scales as expected with gas fill pressure and bias voltage. We expect these current will be sufficient to produce neutral yields of 1 ∙ 10 7 DT n/s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixed Alcohol Synthesis Catalyst Screening 2007 Progress Report

Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) are researching the feasibility of producing mixed alcohols from biomass-derived synthesis gas (syngas). PNNL is obtaining commercially available mixed alcohol or preparing promising mixed-alcohol catalysts and screening them in a laboratory-scale reactor system. The most promising catalysts are provided to NREL for testing using a slipstream from a pilot-scale biomass gasifier. After a review of the literature in 2006 and conversations with companies that produce catalysts, it was determined that no commercial mixed-alcohol synthesis catalysts were available. One manufacturer supplied a modified methanol catalyst that was tested in the PNNL laboratory-scale system and provided to NREL for further testing. PNNL also prepared and tested the behavior of 10 other catalysts representing the distinct catalyst classes for mixed alcohol syntheses. Based on those results,testing in 2007 focused on the performance of the rhodium-based catalysts. The effects of adding promoters to the rhodium catalysts in addition to the manganese already being used were examined. The iron and rhenium promoters both stood out as achieving higher carbon selectivities , followed by Cu. Iridium and Li, on the other hand, had low carbon selectivity ratios of 0.27 and 0.22, respectively. Although testing of candidate promoters is not complete, it appears that Ir and Li promoters warrant further optimization and possibly combination to further improve STYs and carbon selectivities to C2+ oxygenates. However, using these promoters, it will be necessary to incorporate a separate hydrogenation catalyst to improve the yield of C2+ alcohols with respect to the other oxygenates. Fe, Re, and Cu stand out as possible candidates in this respect, but additional research is needed to examine whether they can be combined with the other promoters on the Rh-based catalyst or need to be optimized on a separate catalyst support that is either physically mixed or used in series with the promoted Rh-based catalyst.

09 BIOMASS FUELS↗

COMPONENT DEVELOPMENT NEEDS FOR THE HYBRID SULFUR ELECTROLYZER

Fiscal year 2008 studies in electrolyzer component development have focused on the characterization of membrane electrode assemblies (MEA) after performance tests in the single cell electrolyzer, evaluation of electrocatalysts and membranes using a small scale electrolyzer and evaluating the contribution of individual cell components to the overall electrochemical performance. Scanning electron microscopic (SEM) studies of samples taken from MEAs testing in the SRNL single cell electrolyzer test station indicates a sulfur-rich layer forms between the cathode catalyst layer and the membrane. Based on a review of operating conditions for each of the MEAs evaluated, we conclude that the formation of the layer results from the reduction of sulfur dioxide as it passes through the MEA and reaches the catalyst layer at the cathode-membrane interface. Formation of the sulfur rich layer results in partial delamination of the cathode catalyst layer leading to diminished performance. Furthermore we believe that operating the electrolyzer at elevated pressure significantly increases the rate of formation due to increased adsorption of hydrogen on the internal catalyst surface. Thus, identification of a membrane that exhibits much lower transport of sulfur dioxide is needed to reduce the quantity of sulfur dioxide that reaches the cathode catalyst and is reduced to produce the sulfur-rich layer. Three candidate membranes are currently being evaluated that have shown promise from preliminary studies, (1) modified Nafion{reg_sign}, (2) polybenzimidazole (PBI), and (3) sulfonated Diels Alder polyphenylene (SDAPP). Testing examined the activity for the sulfur dioxide oxidation of platinum (Pt) and platinum-alloy catalysts in 30 wt% sulfuric acid solution. Linear sweep voltammetry showed an increase in activity when catalysts in which Pt is alloyed with non-noble transition metals such as cobalt and chromium. However when Pt is alloyed with noble metals, such as iridium or ruthenium, the kinetic activity decreases. We recommend further testing to determine if these binary alloys will provide the increased reaction kinetic needed to meet the targets. We also plan to test the performance of these catalyst materials for both proton and sulfur dioxide reduction. The latter may provide another parameter by which we can control the reduction of sulfur dioxide upon transport to the cathode catalyst surface. A small scale electrolyzer (2 cm{sup 2}) has been fabricated and successfully installed as an additional tool to evaluate the effect of different operating conditions on electrolyzer and MEA performance. Currently this electrolyzer is limited to testing at temperatures up to 80 C and at atmospheric pressure. Selected electrochemical performance data from the single cell sulfur dioxide depolarized electrolyzer were analyzed with the aid of an empirical equation which takes into account the overpotential of each of the components. By using the empirical equation, the performance data was broken down into its components and a comparison of the potential losses was made. The results indicated that for the testing conditions of 80 C and 30 wt% sulfuric acid, the major overpotential contribution ({approx}70 % of all losses) arise from the slow reaction rate of oxidation of sulfur dioxide. The results indicate that in order to meet the target of hydrogen production at 0.5 A/cm{sup 2} at 0.6 V and 50 wt% sulfuric acid, identification of a better catalyst for sulfur dioxide oxidation will provide the largest gain in electrolyzer performance.

08 HYDROGEN↗

FY07 LDRD Final Report Synthesis under High Pressure and Temperature of New Metal Nitrides

The original aim of this LDRD was to determine with unprecedented precision the melting curve of iron to geophysically relevant pressures. In the course of developing much of the technology and techniques required to obtain this information we have encountered and studied novel chemical reactions some of whose products are stable or metastable under ambient conditions. Specifically we have synthesized nitrides of the platinum group metals including platinum, iridium, and palladium. We have also carried out in depth first principles theoretical investigations into the nature of these materials. We believed that the scientific impact of continuing this work would be greater than that of the original goals of this project. Indeed the work has led to a number of high profile publications with additional publications in preparation. While nitrides of the transition metals are generally of tremendous technological importance, those of the noble metals in particular have enjoyed much experimental and theoretical attention in the very short time since they were first synthesized. The field was and clearly remains open for further study. While the scientific motivation for this research is different from that originally proposed, many of the associated methods in which we have now gained experience are similar or identical. These include use of the diamond anvil cell combined with technologies to generate high temperatures, the in-situ technique of Raman scattering using our purpose-built, state-of-the-art system, analytical techniques for determining the composition of recovered samples such as x-ray photoelectron spectroscopy, and finally synchrotron-based techniques such as x-ray diffraction for structural and equation of state determinations. Close interactions between theorists and experimentalists has and will continue to allow our group to rapidly and reliably interpret complicated results on the structure and dynamics of these compounds and also additional novel materials. Although the purely scientific dividends of this project have been substantial, there remains the possibility of a technological application--now that nitrides with likely desirable properties have been shown to exist, large-scale synthesis techniques can be considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CLOSE-OUT REPORT FOR HYS ELECTROLYZER COMPONENT DEVELOPMENT WORK AT SAVANNAH RIVER NATIONAL LABORATORY

The chemical stability, sulfur dioxide transport, ionic conductivity, and electrolyzer performance have been measured for several commercially available and experimental proton exchange membranes (PEMs) for use in a sulfur dioxide depolarized electrolyzer (SDE). The SDE's function is to produce hydrogen by using the Hybrid Sulfur (HyS) Process, a sulfur based electrochemical/thermochemical hybrid cycle. Membrane stability was evaluated using a screening process where each candidate PEM was heated at 80 C in 63.5 wt. % H{sub 2}SO{sub 4} for 24 hours. Following acid exposure, chemical stability for each membrane was evaluated by FTIR using the ATR sampling technique. Membrane SO{sub 2} transport was evaluated using a two-chamber permeation cell. SO{sub 2} was introduced into one chamber whereupon SO{sub 2} transported across the membrane into the other chamber and oxidized to H{sub 2}SO{sub 4} at an anode positioned immediately adjacent to the membrane. The resulting current was used to determine the SO{sub 2} flux and SO{sub 2} transport. Additionally, membrane electrode assemblies (MEAs) were prepared from candidate membranes to evaluate ionic conductivity and selectivity (ionic conductivity vs. SO{sub 2} transport) which can serve as a tool for selecting membranes. MEAs were also performance tested in a HyS electrolyzer measuring current density versus a constant cell voltage (1V, 80 C in SO{sub 2} saturated 30 wt% H{sub 2}SO{sub 4}). Finally, candidate membranes were evaluated considering all measured parameters including SO{sub 2} flux, SO{sub 2} transport, ionic conductivity, HyS electrolyzer performance, and membrane stability. Candidate membranes included both PFSA and non-PFSA polymers and polymer blends of which the non-PFSA polymers, BPVE-6F and PBI, showed the best selectivity. Testing examined the activity for the sulfur dioxide oxidation of platinum base electrocatalyst in 30 wt% sulfuric acid solution. Linear sweep voltammetry showed an increase in activity when catalysts in which Pt is alloyed with non-noble transition metals such as cobalt, chromium and iron. However when Pt is alloyed with noble metals, such as iridium or ruthenium, the kinetic activity as well as the stability decreases.

08 HYDROGEN↗