Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry

A fully automated method for the separation of low-concentration uranium from plutonium in environmental swipe samples has been developed. The offline chromatography system features renewable 1 mL Eichrom TEVA and UTEVA column generation from bulk resin slurry. Discrete fractions of the separated actinides are delivered into user defined vials for future analysis. Clean room background levels were achieved outside of a cleanroom environment with this method. Purification of uranium and plutonium from various sample matrixes and at various concentrations was successful. Major and minor isotope ratios for both elements were measured via multiple collector inductively coupled plasma mass spectrometry and were in good agreement with certified reference values. Lastly, validation of the separation method was conducted on archived environmental samples and agreed with values previously reported using standard column chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning Kinetic Inductance with Doping in Superconducting Electron Gases at the KTaO 3 (111) Interface

We used coplanar waveguide resonators fabricated from the two-dimensional superconductor formed at KTaO 3 (111) interfaces to characterize the superconductor’s sheet kinetic inductance L K/□ . Upon varying the carrier density, in samples with T c ranging from 0.62 to 1.81 K, we can tune L K/□ between 1.88 and 7.42 nH/□ at the lowest temperatures, exceeding the highest values reported for granular aluminum films. The temperature dependence of L K/□ is consistent with a superconducting gap without nodes. The high L K/□ of superconducting KTaO 3 (111) interfacial electron gases combined with the high dielectric constant of KTaO 3 results in resonators with exceedingly low phase velocities (“slow light”) and small mode volumes. In addition, superconducting KTaO 3 (111) interfacial electron gases are robust in magnetic fields well above a Tesla. In conclusion, these features can enable unique device applications in superconducting electronics and quantum information science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗

Axion optical induction of antiferromagnetic order

Using circularly polarized light to control quantum matter is a highly intriguing topic in physics, chemistry and biology. Previous studies have demonstrated helicity-dependent optical control of chirality and magnetization, with important implications in asymmetric synthesis in chemistry; homochirality in biomolecules; and ferromagnetic spintronics. We report the surprising observation of helicity-dependent optical control of fully compensated antiferromagnetic order in two-dimensional even-layered MnBi 2 Te 4 , a topological axion insulator with neither chirality nor magnetization. Furthermore, to understand this control, we study an antiferromagnetic circular dichroism, which appears only in reflection but is absent in transmission. We show that the optical control and circular dichroism both arise from the optical axion electrodynamics. Our axion induction provides the possibility to optically control a family of PT-symmetric antiferromagnets (P, inversion; T, time-reversal) such as Cr 2 O 3 , even-layered CrI3 and possibly the pseudo-gap state in cuprates. In MnBi 2 Te 4 , this further opens the door for optical writing of a dissipationless circuit formed by topological edge states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

Laser-ablation sampling for inductively coupled plasma distance-of-flight mass spectrometry

An inductively coupled plasma distance-of-flight mass spectrometer (ICP-DOFMS) has been coupled with laser-ablation (LA) sample introduction for the elemental analysis of solids. ICP-DOFMS is well suited for the analysis of laser-generated aerosols because it offers both high-speed mass analysis and simultaneous multi-elemental detection. Here, we evaluate the analytical performance of the LA-ICP-DOFMS instrument, equipped with a microchannel plate-based imaging detector, for the measurement of steady-state LA signals, as well as transient signals produced from single LA events. Steady-state detection limits are 1 mg g1, and absolute single-pulse LA detection limits are 200 fg for uranium; the system is shown capable of performing time-resolved single-pulse LA analysis. By leveraging the benefits of simultaneous multi-elemental detection, we also attain a good shot-to-shot reproducibility of 6% relative standard deviation (RSD) and isotope-ratio precision of 0.3% RSD with a 10 s integration time.

Gundlach-Graham, Alexander W.↗

Phosphorus speciation analysis of fatty-acid-based feedstocks and fast pyrolysis biocrudes via gel permeation chromatography inductively coupled plasma high-resolution mass spectrometry

Renewable feedstocks, such as lignocelulosic fast pyrolysis oils and both vegetable oil and animal fats, are becoming a viable alternative to petroleum for producing high-quality renewable transportation fuels. However, the presence of phosphorus-containing compounds, mainly from phospholipids, in these renewable feedstocks is known to poison and deactivate hydrotreating catalysts during fuel production. In this work, gel permeation chromatography (GPC) combined with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was used to analyze feedstocks including unprocessed soybean oil, animal fat, and pyrolysis oils from red oak and milorganite to identify phosphorus species. The results have shown the presence of a wide range of different phosphorous compounds among all the samples analysed in this work. The GPC-ICP-HRMS analyses of a vegetable oil and two animal fats have shown different fingerprints based on the molecular weight of each of the samples, highlighting the structural differences among their corresponding phosphorus-containing compounds. While the presence of low-molecular-weight species, such as phospholipids, was expected, several high-molecular-weight species (MW > 10 000 Da) have been found, suggesting that high-molecular-weight micelles or liposomes might have been formed due to the high concentration of phospholipids in these samples. Results obtained through the hydroxylation of a mix of phospholipids (asolectin) and its posterior GPC-ICP-HRMS agree with this hypothesis. With respect to the lignocellulosic catalytic fast pyrolysis oil samples, the GPC-ICP-HRMS results obtained suggest that either aggregation or polymerization reactions might have occurred during the pyrolysis process, yielding phosphorus-containing compounds with an approximate molecular weight above 91 000 kDa. In addition, an aggregation phenomenom has been observed for those phosphorus species present within the fast pyrolysis oils after being stored for 3 months, especially for those pyrolysis oils contaning pre-processed feedstocks, such as milorganite.

09 BIOMASS FUELS↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact of gas purity on observed reactivity with NO using inductively coupled plasma tandem mass spectrometry

Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The balance of orbital overlap and orbital energy in the activation of methane by actinide cations: insights from inductively coupled plasma tandem mass spectrometry

The actinides present a unique challenge to chemical theory. The classical view of covalent bonding is driven by the extent of spatial overlap of valence orbitals. Modern theory has expanded assessments of covalency to include considerations of orbital energy degeneracy to assess orbital energy mixing between metal and ligand valence orbitals. Actinide–ligand (An–L) bonding has more recently been described as a balance between orbital overlap and orbital energy mixing, where 5f and L valence orbital overlap decreases while energy mixing between An 5f and L valence orbitals increases across the series. To test these existing views, we employed inductively coupled plasma tandem mass spectrometry to examine the kinetic energy dependences of reactions of actinide cations, Th + –Am + , with methane. Further, this is the first experimental report of the energy dependences of methane activation reactions involving the cations of Pa, Np, Pu, and Am and the first experimental determination of transuranic An + –D, An + –CD 2 , An + –CD 3 , and An + –CD bond dissociation energies. The correlation of the measured An + –CD 2 bond energies with E p (6d 2 ) indicates that An + 6d orbitals are the dominant contributors in the An + –CD 2 bonds. Close examination of the relative reactivities of An + offers additional support that the balance of classical and modern views of molecular bonding may lie between Np + and Pu + and that the increased reactivity of Th + –Np + may be attributed to the increased spatial extension of the 5f orbitals whereas covalent An + bond formation may be more driven by the decreasing energies of the 5f orbitals across the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic insight into AnO 2 + bonding from ThH + /UH + reactions studied by inductively coupled plasma tandem mass spectrometry

The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.

5f orbitals↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗