Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Macrophysical Properties of Tropical Cirrus Clouds from the CALIPSO Satellite and from Ground-based Micropulse and Raman Lidars

Lidar observations of cirrus cloud macrophysical properties over the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) program Darwin, Australia site are compared from the Cloud-Aerosol Lidar and In- frared Pathfinder Satellite Observation (CALIPSO) satellite, the ground-based ARM micropulse lidar (MPL), and the ARM Raman lidar (RL). Comparisons are made using the subset of profiles where the lidar beam is not fully attenuated. Daytime measurements using the RL are shown to be relatively unaffected by the solar background and are therefore suited for checking the validity of diurnal cycles. RL and CALIPSO cloud fraction profiles show good agreement while the MPL detects significantly less cirrus, particularly during the daytime. Both MPL and CALIPSO observations show that cirrus clouds occur less frequently during the day than at night at all altitudes. In contrast, the RL diurnal cy- cle is significantly different than zero only below about 11 km; where it is the opposite sign (i.e. more clouds during the daytime). For cirrus geomet- rical thickness, the MPL and CALIPSO observations agree well and both datasets have signficantly thinner clouds during the daytime than the RL. From the examination of hourly MPL and RL cirrus cloud thickness and through the application of daytime detection limits to all CALIPSO data we find that the decreased MPL and CALIPSO cloud thickness during the daytime is very likely a result of increased daytime noise. This study highlights the vast im- provement the RL provides (compared to the MPL) in the ARM program's ability to observe tropical cirrus clouds as well as a valuable ground-based lidar dataset for the validation of CALIPSO observations and to help im- prove our understanding of tropical cirrus clouds.

Cirrus Clouds↗

Enhancing Bottom-up and Top-down Proteomic Measurements with Ion Mobility Separations

Proteomic measurements with greater throughput, sensitivity and additional structural information enhance the in-depth characterization of complex mixtures and targeted studies with additional information and higher confidence. While liquid chromatography separation coupled with mass spectrometry (LC-MS) measurements have provided information on thousands of proteins in different sample types, the additional of another rapid separation stage providing structural information has many benefits for analyses. Technical advances in ion funnels and multiplexing have enabled ion mobility separations to be easily and effectively coupled with LC-MS proteomics to enhance the information content of measurements. Finally, herein, we report on applications illustrating increased sensitivity, throughput, and structural information by utilizing IMS-MS and LC-IMS-MS measurements for both bottom-up and top-down proteomics measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM)

Structures for Lossless Ion Manipulations (SLIM) is a powerful variant of traveling wave ion mobility spectrometry (TW-IMS) that uses a serpentine pattern of microelectrodes deposited onto printed circuit boards to achieve ultralong ion path lengths (13.5 m). Ions are propelled through SLIM platforms via arrays of TW electrodes while RF and DC electrodes provide radial confinement, establishing near lossless transmission. The recent ability to cycle ions multiple times through a SLIM has allowed ion path lengths to exceed 1000 m, providing unprecedented separation power and the ability to observe ion structural conformations unobtainable with other IMS technologies. The combination of high separation power, high signal intensity, and the ability to couple with mass spectrometry places SLIM in the unique position of being able to address longstanding proteomics and metabolomics challenges by allowing the characterization of isomeric mixtures containing low abundance analytes.

Hollerbach, Adam L.↗

Strong constraints on the b → sγ photon polarisation from B0 → K*0e+e-decays

An angular analysis of the B 0 → K* 0 e + e - decay is performed using a data sample corresponding to an integrated luminosity of 9 fb - 1 of pp collisions collected with the LHCb experiment. The analysis is conducted in the very low dielectron mass squared ( q 2 ) interval between 0 . 0008 and 0 . 257 GeV 2 , where the rate is dominated by the B 0 → K * 0 γ transition with a virtual photon. The fraction of longitudinal polarisation of the K * 0 meson, F L , is measured to be F L = (4 . 4 ± 2 . 6 ± 1 . 4)%, where the first uncertainty is statistical and the second systematic. The \( {A}_{\mathrm{T}}^{\mathrm{Re}} \) observable, which is related to the lepton forward-backward asymmetry, is measured to be \( {A}_{\mathrm{T}}^{\mathrm{Re}} \) = - 0 . 06 ± 0 . 08 ± 0 . 02. The \( {A}_{\mathrm{T}}^{(2)} \) and \( {A}_{\mathrm{T}}^{\mathrm{Im}} \) transverse asymmetries, which are sensitive to the virtual photon polarisation, are found to be \( {A}_{\mathrm{T}}^{(2)} \) = 0 . 11 ± 0 . 10 ± 0 . 02 and \( {A}_{\mathrm{T}}^{\mathrm{Im}} \) = 0 . 02 ± 0 . 10 ± 0 . 01. The results are consistent with Standard Model predictions and provide the world’s best constraint on the b → sγ photon polarisation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Review of Global Radioxenon Background Research and Issues

Among the most important problems for the world-wide nuclear explosion monitoring is the interference of naturally occurring and man-made radionuclides. The International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) frequently detects these interferences using sensitive radionuclide measurement equipment. We commonly refer to the presence of radionuclides that are relevant to the CTBT but do not originate from a nuclear explosion as “background”. Backgrounds are highest near the sources but are known to have regional and global effects on the IMS. This review paper summarizes much of the relevant work in the area of background and discusses issues of interest for nuclear explosion detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Evaluating the structural complexity of isomeric bile acids with ion mobility spectrometry

Bile acids (BAs) play an integral role in digestion through the absorption of nutrients, emulsification of fats and fat-soluble vitamins, and maintenance of cholesterol levels. Metabolic disruption, diabetes, colorectal cancer, and numerous other diseases have been linked with BA disruption, making improved BA analyses essential. To date, most BA measurements are performed using liquid chromatography separations in conjunction with mass spectrometry measurements (LC-MS). However, 10–40 min LC gradients are often used for BA analyses and these may not even be sufficient for distinguishing all the important isomers present in the human body. Ion mobility spectrometry (IMS) is a promising tool for BA evaluations due to its ability to quickly separate isomeric molecules with subtle structural differences. In this study, we utilized drift tube IMS (DTIMS) coupled with MS to characterize 56 different unlabeled BA standards and 16 deuterated versions. In the DTIMS-MS analyses of 12 isomer groups, BAs with smaller m/z values were easily separated in either their deprotonated or sodiated forms (or both). However, as the BAs grew in m/z value, they became more difficult to separate with two isomer groups being inseparable. Metal ions such as copper and zinc were then added to the overlapping BAs, and due to different binding sites, the resulting complexes were separable. Thus, the rapid structural measurements possible with DTIMS-MS show great potential for BAs measurements with and without prior LC separations.

Zheng, Xueyun↗

Fundamental Optical Functions and Fine-Structure Parameters of Strontium–Selenide Crystal Transition Bands in the 0–40 eV Range

The spectral complex of fundamental optical functions of strontium-selenide (SrSe) crystal in the range 0–40 eV was determined. Spectra of the imaginary parts of three functions [transverse dielectric permittivity ε{sub 2}(E) and longitudinal volume –Im ε{sup –1} and surface –Im (1 + ε){sup –1} characteristic electron energy losses] of SrSe crystal were deconvoluted into 36 elementary bands. Energies of maxima E{sub i}, half-widths H{sub i}, amplitudes I{sub i}, areas S{sub i}, and oscillator strengths f{sub i} were determined for every band of the three spectra. The main spectral features of the optical functions and 36 elementary bands of SrSe in the range 3–35 eV due to excitons and transverse and longitudinal interband transitions were established. The calculations were based on experimental reflectance spectra and used the Kramers–Kronig integral relations, a modified combined Argand diagram method, and a number of computer programs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of the Fundamental Optical Functions of Magnesium Silicide

The spectra of 16 optical Mg{sub 2}Si functions in the range from 0 to 11 eV at 77 K are determined. They contain five maxima and shoulders due to interband transitions and metastable excitons, as well as the maxima of bulk and surface plasmons at ~9.56 and ~7.30 eV. Their peculiarities and general patterns of behavior are established. Calculations were performed based on a well-known experimental reflection spectrum in the range from 0 to 11 eV at 77 K. The integral spectra of the imaginary parts of the permittivity ε{sub 2}(E), characteristic bulk (–Im ε{sup –1}), and surface (–Im (1 + ε){sup –1}) energy losses of electrons are expanded into elementary components in the region from 2 to 5 eV. The main parameters of the transition components were determined, including the energies of their maxima and oscillator strengths. Calculations were carried out using computer programs based on the Kramers–Kronig relations and known analytical formulas for the correlation between optical functions, as well as an improved nonparametric method of combined Argand diagrams taking into account the effective number of valence electrons participating in the formation of individual bands. Instead of five maxima and shoulders of the integral spectra, 17 elementary bands with oscillator strengths in the range from 0.0003 to 1.92 were established. They are due to transverse and longitudinal type excitonic and interband transitions. Based on known theoretical calculations, we propose herein the localization and assumed nature of the optical transition bands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solubility of B-Nb2O5 and the Hydrolysis of Niobium(V) in Aqueous Solution as a Function of Temperature and Ionic Strength

B-Nb{sub 2}O{sub 5} was recrystallized from commercially available oxide, and XRD analyses indicated that it is stable in contact with solutions over the pH range 0 to 9, whereas solid polyniobates such as Na{sub 8}Nb{sub 6}O{sub 19} 13H{sub 2}O(s) appear to predominate at pH > 9. Solubilities of the crystalline B-Nb{sub 2}O{sub 5} were determined in five NaClO{sub 4} solutions (0.1 {le} Im/mol {center_dot} kg{sup -1} {le} 1.0) over a wide pH range at (25.0 {+-} 0.1) C and at 0.1 MPa. A limited number of measurements were also made at Im = 6.0 mol {center_dot} kg{sup -1}, whereas at Im = 1.0 mol {center_dot} kg{sup -1} the full range of pH was also covered at (10, 50 and 70) C. The pH of these solutions was fixed using either HClO{sub 4} (pH {le} 4) or NaOH (pH {ge} 10) and determined by mass balance, whereas the pH on the molality scale was measured in buffer mixtures of acetic acid + acetate (4 {le} pH {le} 6), Bis-Tris (pH {approx} 7), Tris (pH {approx} 8) and boric acid + borate (pH {approx} 9). Treatment of the solubility results indicated the presence of four species, Nb(OH){sub n}{sup 5-n} (where n = 4-7), so that the molal solubility quotients were determined according to: 0.5Nb{sub 2}O{sub 5}(cr) + 0.5(2n-5)H{sub 2}O(l){sup {center_dot}-} Nb(OH){sub n}{sup 5-n} + (n-5)H{sup +} (n = 4-7) and were fitted empirically as a function of ionic strength and temperature, including the appropriate Debye-Hueckel term. A Specific Interaction Theory (SIT) approach was also attempted. The former approach yielded the following values of log 10 K{sub sn} (infinite dilution) at 25 C: -(7.4 {+-} 0.2) for n = 4; -(9.1 {+-} 0.1) for n = 5; -(14.1 {+-} 0.3) for n = 6; and -(23.9 {+-} 0.6) for n = 7. Given the experimental uncertainties (2{sigma}), it is interesting to note that the effect of ionic strength only exceeded the combined uncertainties significantly in the case of log 10 K{sub s6} to I{sub m} = 1.0 mol {center_dot} kg{sup -1}, such that these values may be of use by defining their magnitudes in other media. Values of {Delta}{sub f} g{sup o}, {Delta}{sub f} H{sup o}, 5{sup o} and C{sub p}{sup o} (298.15 K, 0.1 MPa) for each hydrolysis product were calculated and tabulated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Worldwide measurements of radioxenon background near isotope production facilities, a nuclear power plant and at remote sites: the ‘‘EU/JA-II’’ Project

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) specifies that radioxenon measurements should be performed at 40 or more stations worldwide within the International Monitoring System (IMS). Measuring radioxenon is one of the principle techniques to detect underground nuclear explosions. Specifically, presence and ratios of different radioxenon isotopes allows determining whether a detection event under consideration originated from a nuclear explosion or a civilian source. However, radioxenon monitoring on a global scale is a novel technology and the global civil background must be characterized sufficiently. This paper lays out a study, based on several unique measurement campaigns, of the worldwide concentrations and sources of verification relevant xenon isotopes. It complements the experience already gathered with radioxenon measurements within the CTBT IMS programme and focuses on locations in Belgium, Germany, Kuwait, Thailand and South Africa where very little information was available on ambient xenon levels or interesting sites offered opportunities to learn more about emissions from known sources. The findings corroborate the hypothesis that a few major radioxenon sources contribute in great part to the global radioxenon background. Additionally, the existence of independent sources of 131mXe (the daughter of 131I) has been demonstrated, which has some potential to bias the isotopic signature of signals from nuclear explosions.

Saey, P. R.J.↗

Construction of a Shallow Underground Low-background Detector for a CTBT Radionuclide Laboratory

The International Monitoring System (IMS) is a verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), and in addition to a series of radionuclide monitoring stations, contains sixteen radionuclide laboratories capable of verification of radionuclide station measurements. This paper presents an overview of a new commercially obtained low-background detector system for radionuclide aerosol measurements recently installed in a shallow (>30 meters water equivalent) underground clean-room facility at Pacific Northwest National Laboratory. Specifics such as low-background shielding materials, active shielding methods, and improvements in sensitivity to IMS isotopes will be covered.

Forrester, Joel B.↗

Parallel Radioisotope Collection and Analysis in Response to the Fukushima Release

Two independent air samplers were operated at Pacific Northwest National Laboratory in parallel during the collection of samples from the Fukushima reactor releases. One system is an automated aerosol collection and analysis unit, while the other was a manual sampler of higher daily air volume. The samples collected each day showed excellent correlation in radionuclide activity, although some variations were seen. These variations illustrate the reproducibility of the air sample radionuclide measurements made by the Comprehensive Nuclear-Test-Ban Treaty International Monitoring System (IMS) and show a simple way to acquire useful parallel samples for scientific purposes. In particular, a party wishing to have a “copy” of a sample acquired by the verification regime of the treaty could employ this method and have results similar to the IMS station at low cost and even higher sensitivity.

Atmospheric Aerosol Sampling↗

Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector

The Comprehensive Test Ban Treaty (CTBT) bans nuclear weapons testing and establishes the International Monitoring System (IMS) for the purpose of treaty verification. IMS is a detector network that confirms that global nuclear activity is peaceful in nature. These detector systems use β-γcoincidence measurements to characterize atmospheric samples containing radioxenon isotopes. The goal of this work is to use the system consisting of two sodium iodide detectors and two PIPSbox detectors to characterize isotopically pure samples of 131m Xe, 133m Xe, 133 Xe, and 135 Xe via β, γ, and β-γ coincidence measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Structure-forming role of heterocyclic compounds in the synthesis of metal-organic frameworks based on cadmium(II)

The influence of heterocyclic compounds on the formation of coordination polymers in the system of cadmium(II) nitrate tetrahydrate and biphenyl-4,4′-dicarboxylic acid is demonstrated. Two new coordination polymers [Cd(H{sub 2}O)(bpdc)(im){sub 2}] (1, bpdc{sup 2–} is biphenyl-4,4′-dicarboxylate, im is imidazole) and [(CH{sub 3}){sub 2}NH{sub 2}]{sub 4}[Cd{sub 6}(dmf)(bpdc){sub 8}]·10DMF (2) were obtained under solvothermal conditions in the presence of imidazole or benzimidazole, respectively. Product 1 has a chain structure, while compound 2 possesses a three-dimensional structure with the hex topology. The obtained compounds were characterized by IR spectroscopy, thermogravimetry, elemental analysis, and powder X-ray diffraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Sampling with Direct Ion Mobility Spectrometric Detection for Explosives Analysis

This study investigates the potential and limitations of a streamlined, field-deployable analytical approach that involves selective capture of explosive materials with direct analysis by ion mobility spectrometry (IMS). Selective capture of explosives was performed on deactivated quartz fiber filters impregnated with metal β-diketonate polymers. These Lewis acidic polymers selectively interact with Lewis base analytes such as explosives. The filter coupons could be directly inserted into an IMS instrument for analysis. The uptake kinetics of 2,4,6-trinitrotoluene (TNT) from a saturated atmosphere were characterized, and based on these studies, passive equilibrium sampling was applied to estimate the TNT concentration within an ammunition magazine that contained bulk TNT. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) uptake from a saturated environment also was examined over a one-month period. Each incremental sampling period showed increasing quantities of RDX culminating with collection of approximately 5 ng of RDX on the coupon at the end of one month. This is the first time that gas-phase uptake of RDX has been demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Atmospheric pressure ionization of chlorinated ethanes in ion mobility spectrometry and mass spectrometry

This study investigates the APCI mechanisms associated with chlorinated ethanes in an attempt to define conditions under which unique pseudo-molecular adducts, in addition to chloride ion, can be produced for analytical measurements using IMS and MS. The ionization chemistry of chlorinated compounds typically leads to the detection of only the halide ions. Using molecular modeling, which provides insights into the ion formation and relative binding energies, predictions for the formation of pseudo-molecular adducts are postulated. Predicted structures of the chloride ion with multiple hydrogens on the ethane backbone was supported by the observation of specific pseudo-molecular adducts in IMS and MS spectra. With the proper instrumental conditions, such as short reaction times and low temp.

Atmospheric Pressure Ionization↗

Simulation of Electric Potentials and Ion Motion in Planar Electrode Structures for Lossless Ion Manipulations (SLIM)

Here we report a conceptual study and computational evaluation of novel planar electrode Structures for Lossless Ion Manipulations (SLIM). Planar electrode SLIM devices were designed that allow for flexible ion confinement, transport and storage using a combination of RF and DC fields. Effective potentials can be generated that provide near ideal regions for confining ions in the presence of a gas. Ion trajectory simulations using SIMION 8.1 demonstrated the capability for lossless ion motion in these devices over a wide m/z range and a range of electric fields at low pressures (e.g. a few torr). More complex ion manipulations, e.g. turning ions by 90° and dynamically switching selected ion species into orthogonal channels, are also feasible. Lastly, the performance of SLIM devices at ~4 torr pressure for performing ion mobility based separations (IMS) is computationally evaluated and compared to initial experimental results, and both of which agree closely with experimental and theoretical IMS performance for a conventional drift tube design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗