Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Using an ultra-thin non-doped orange emission layer to realize high efficiency white organic light-emitting diodes with low efficiency roll-off

By adopting an ultra-thin non-doped orange emission layer sandwiched between two blue emission layers, high efficiency white organic light-emitting diodes (WOLEDs) with reduced efficiency roll-off were fabricated. The optimized devices show a balanced white emission with Internationale de L'Eclairage of (0.41, 0.44) at the luminance of 1000 cd/m{sup 2}, and the maximum power efficiency, current efficiency (CE), and external quantum efficiency reach 63.2 lm/W, 59.3 cd/A, and 23.1%, which slightly shift to 53.4 lm/W, 57.1 cd/A, and 22.2% at 1000 cd/m{sup 2}, respectively, showing low efficiency roll-off. Detailed investigations on the recombination zone and the transient electroluminescence (EL) clearly reveal the EL processes of the ultra-thin non-doped orange emission layer in WOLEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Efficiency Model Predictive Control for Star-Connected Cascaded H-Bridge STATCOM Under Unbalanced Conditions

This paper presents a high-efficiency model predictive control (HMPC), which is enabled by a sorting approach based on dc capacitor voltages to significantly reduce the exponentially-increasing switching states in cascaded Hbridge (CHB) converters. In addition, a generic discrete-time prediction model for star-connected CHB static synchronous compensator is proposed to address the issues due to either grid and/or load unbalances. Both simulation and hardware-in-loop experimental results are presented to validate the feasibility and effectiveness of the proposed HMPC strategy.

Li, Yufei↗

TU-C-BRE-02: A Novel, Highly Efficient and Automated Quality Assurance Tool for Modern Linear Accelerators

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. Varian’s Machine Performance Check (MPC) uses IsoCal phantom to test geometric and dosimetric aspects of the TrueBeam systems in <5min. In this study we independently tested the accuracy and robustness of the MPC tools. Methods: MPC is automated for simultaneous image-acquisition, using kV-and-MV onboard-imagers (EPIDs), while delivering kV-and-MV beams in a set routine of varying gantry, collimator and couch angles. MPC software-tools analyze the images to test: i) beam-output and uniformity, ii) positional accuracy of isocenter, EPIDs, collimating jaws (CJs), MLC leaves and couch and iii) rotational accuracy of gantry, collimator and couch. 6MV-beam dose-output and uniformity were tested using ionization-chamber (IC) and ICarray. Winston-Lutz-Tests (WLT) were performed to measure isocenter-offsets caused by gantry, collimator and couch rotations. Positional accuracy of EPIDs was evaluated using radio-opaque markers of the IsoCal phantom. Furthermore, to test the robustness of the MPC tools we purposefully miscalibrated a non-clinical TrueBeam by introducing errors in beam-output, energy, symmetry, gantry angle, couch translations, CJs and MLC leaves positions. Results: 6MV-output and uniformity were within ±0.6% for most measurements with a maximum deviation of ±1.0%. Average isocenter-offset caused by gantry and collimator rotations was 0.316±0.011mm agreeing with IsoLock (0.274mm) and WLT (0.41mm). Average rotation-induced couch-shift from MPC was 0.378±0.032mm agreeing with WLT (0.35mm). MV-and-kV imager-offsets measured by MPC were within ±0.15mm. MPC predicted all machine miscalibrations within acceptable clinical tolerance. MPC detected the output miscalibrations within ±0.61% while the MLC and couch positions were within ±0.06mm and ±0.14mm, respectively. Gantry angle miscalibrations were detected within ±0.1°. Conclusions: MPC is a useful tool for QA of TrueBeam systems and its automation makes it highly efficient for testing both geometric and dosimetric aspects of the machine. This is very important for hypo-fractionated SBRT treatments. Received support from Varian Medical Systems, Palo Alto, CA 94304-1038.

07 ISOTOPE AND RADIATION SOURCES↗

Sequestering Rare Earth Elements and Precious Metals from Seawater Using a Highly Efficient Polymer Adsorbent Derived from Acrylic Fiber

An amidoxime and carboxylate containing polymer adsorbent derived from acrylic fiber has shown extremely high efficiencies for extracting critical materials and precious metals from seawater. Among 50 extractable elements, the lanthanides, cobalt, and palladium were ranked near the top with KD values in the order of 107, about an order of magnitude higher than that of uranium. The KD value of the lanthanides increased linearly with the atomic number indicating charge density is a factor controlling trivalent lanthanide extractability in seawater. The data given in this report provides crucial information regarding the strategies of ocean mining of critical materials and precious metals.

36 MATERIALS SCIENCE↗

X-band noise temperature near the Sun at a 34-meter high efficiency antenna

The X-band system noise temperature near the Sun was measured at the DSS 15, a 34 meter high efficiency (HEF) antenna, in November 1987. Data was taken at angles off the center of the Sun from 0 to 4 degrees. At angles greater than 0.5 degree, the measured results agree with Voyager tracking data taken at solar conjunction in late December 1987. Within the solar disk, at angles lower than 0.27 degree, the temperature measured was lower than the prediction of a model by 30 percent, after adjusting for known receiver nonlinearities. The discrepancy in this extreme case is probably caused by unknown nonlinearities in the receiver, uncertainties in the model, or both. The measurement is nevertheless credible for practically all Sun-Earth-probe angles of interest to deep space missions.

Rebold, T. A.↗

LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

total ionizing dose (TID)↗

Indium-Tin-Oxide-Based Transparent Conducting Layers for Highly Efficient Photovoltaic Devices

Additional hydrogen (H{sub 2}) annealing and subsequent electrochemical treatment are found to make tin-doped indium oxide (ITO)-based photoelectrodes suitable for highly efficient dye sensitized solar cells. The additional H{sub 2} annealing process recovered the electrical conductivity of the ITO film the same as its initial high conductivity, which enhanced the charge collecting property. Moreover, the employment of electrochemical oxidation of TiO{sub 2}/ITO photoelectrode improved the energy conversion efficiency of the ITO-based dye-sensitized solar cells (DSSC), higher than that of a conventional FTO-based DSSC. Electrochemical impedance analysis showed that the H2 annealing process reduced the internal resistance of the cell, i.e., the resistance of the ITO and the Schottky barrier at the TiO{sub 2}/ITO interface were reduced, and that the electrochemical treatment recovered the diodelike characteristics of the DSSC by retarding back electron transfer from the photoelectrode to the electrolyte. The present work demonstrates that thermally and electrochemically modified ITO-based photoelectrode is another alternative to the conventionally used FTO-based photoelectrode.

14 SOLAR ENERGY↗

Bifacial Si heterojunction-perovskite organic-inorganic tandem to produce highly efficient (η T * ~ 33%) solar cell

As single junction photovoltaic (PV) technologies, both Si heterojunction (HIT) and perovskite based solar cells promise high efficiencies at low cost. Intuitively, a traditional tandem cell design with these cells connected in series is expected to improve the efficiency further. Using a self-consistent numerical modeling of optical and transport characteristics, however, we find that a traditional series connected tandem design suffers from low J SC due to band-gap mismatch and current matching constraints. Furthermore, a traditional tandem cell with state-of-the-art HIT (η = 24%) and perovskite (η = 20%) sub-cells provides only a modest tandem efficiency of η T ~ 25%. Instead, we demonstrate that a bifacial HIT/perovskite tandem design decouples the optoelectronic constraints and provides an innovative path for extraordinary efficiencies. In the bifacial configuration, the same state-of-the-art sub-cells achieve a normalized output of η T * = 33%, exceeding the bifacial HIT performance at practical albedo reflections. Unlike the traditional design, this bifacial design is relatively insensitive to perovskite thickness variations, which may translate to simpler manufacture and higher yield.

14 SOLAR ENERGY↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of high efficiency (14 percent) solar cell array module

Most effort was concentrated on development of procedures to provide large area (3 in. diameter) high efficiency (16.5 percent AM1, 28 C) P+NN+ solar cells. Intensive tests with 3 in. slices gave consistently lower efficiency (13.5 percent). The problems were identified as incomplete formation of and optimum back surface field (BSF), and interaction of the BSF process and the shallow P+ junction. The problem was shown not to be caused by reduced quality of silicon near the edges of the larger slices.

Iles, P. A.↗

Highly efficient four-wave mixing in a coherent six-level system in ultraslow propagation regime

We propose a scheme to obtain a highly efficient four-wave mixing (FWM) in a coherent six-level tripod system by using a double-dark resonance and multiphoton destructive interference induced transparency. We show both analytically and numerically that the optical-wave mixing in such a system with a pump wave and an internally generated FWM wave mediated by electromagnetically induced transparency and hence propagating with matched ultraslow group velocities can result in a significant enhancement of FWM conversion efficiency. This interesting scheme may be used to generate coherent short-wavelength radiation in dense optical media with very low pump-wave intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A highly efficient, 10-J output signal amplifier for ultra-intense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 x 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. Here, the seed beam (170 nm, 240 mJ) was provided by the preceding OPCPA stages. The maximum pump-to-signal conversion efficiency of 37% was achieved with a 52-mm-long DKDP crystal and 40-J pump energy at 527 nm due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape. The 11.8-J output signal was compressed to 19 fs.

42 ENGINEERING↗

Large-area high-efficiency ion-implanted cells and flat-plate modules

This paper reports the development of a flat-plate module based on highly efficient ion-implanted silicon solar cells. The cells are 53 sq cm in area and have exhibited AM 1.5 efficiencies of over 18 percent. The use of back surface reflectors to reduce module operating temperature is discussed. A comparison of various approaches to cell design is made, and module test data for these designs are presented. Module efficiency of 14 percent (25 C) is reported.

Spitzer, M. B.↗