Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat transfer performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Internal Thermal Control System Hose Heat Transfer Fluid Thermal Expansion Evaluation Test Report

During assembly of the International Space Station, the Internal Thermal Control Systems in adjacent modules are connected by jumper hoses referred to as integrated hose assemblies (IHAs). A test of an IHA has been performed at the Marshall Space Flight Center to determine whether the pressure in an IHA filled with heat transfer fluid would exceed the maximum design pressure when subjected to elevated temperatures (up to 60 C (140 F)) that may be experienced during storage or transportation. The results of the test show that the pressure in the IHA remains below 227 kPa (33 psia) (well below the 689 kPa (100 psia) maximum design pressure) even at a temperature of 71 C (160 F), with no indication of leakage or damage to the hose. Therefore, based on the results of this test, the IHA can safely be filled with coolant prior to launch. The test and results are documented in this Technical Memorandum.

Wieland, P. O.↗

Fuel Cell Thermal Management Through Conductive Cooling Plates

An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

Colozza, Anthony J.↗

A Machine Learning Framework for Error Compensation in Radiative Transfer Calculations

Radiative heat transfer influences the amount of heat flux transferred to the surface of the hypersonic vehicle, which is essential to evaluate the performance of thermal protection systems. The radiative heat flux is found to be computationally prohibitive while accounting for the variation in spatial, angular, and spectral domains. A new methodology has been recently developed to alleviate the cost of computation in the spectral domain by constructing flow-agnostic reduced-order models (ROMs). The developed spectral ROM databases provide grouping strategies that account for non-equilibrium absorption and emission as well as interaction between disparate species due to spectral overlap in associated radiative processes. However, the developed ROMs need to be optimized for a specific combination of interacting gas species and would need to re-calibrated in case individual species are added/omitted. In this work, we use various machine learning (ML) techniques to approximate the radiative intensities determined by a ROM optimized for a specific gas mixture. The ML model relies on the ROM databases developed for a single species which ignores any spectral overlap. Thus, radiation evaluation starts with a simple summation of radiative intensities predicted using these non-calibrated ROMs for the contributing species. The ML framework then provides a correction to account for the interplay in the frequency, i.e., emission of photons by one species and absorption by another, and yields mixture-specific radiation fields. Once trained on the individual ROM databases, the ML framework offers instantaneous corrections that serves as a time/cost effective alternative to the optimization of ROMs for a specific gas mixture. The ML framework is trained on both the high fidelity and ROM evaluated line of sight (LOS) data from Orion, Stardust, and FIRE II cases to obtain a general purpose correction model for earth re-entry scenarios when radiation contributions from both atomic nitrogen and atomic oxygen are considered. A geometric length scale parameter is used in the training process to account for errors introduced in the ROM databases as a consequence of high optical thickness. The efficacy of the ML framework is underscored through extensive analysis of train and test errors with respect to all the re-entry scenarios. The applicability of such an ML framework was further corroborated by embedding it in a state-of-the-art US3D - NERO system for determining the radiative heat flux transferred to the hypersonic vehicle surface.

Radiation↗

Performance Expectations of Closed-Brayton-Cycle Heat Exchangers in 100-kWe Nuclear Space Power Systems

Performance expectations of closed-Brayton-cycle heat exchangers to be used in 100-k We nuclear space power systems were forecast. Proposed cycle state points for a system supporting a mission to three of Jupiter's moons required effectiveness values for the heat-source exchanger, recuperator and rejection exchanger (gas cooler) of 0.98, 0.95, and 0.97, respectively. Performance parameters such as number of thermal units (Ntu), equivalent thermal conductance (UA), and entropy generation numbers (Ns) varied from 11 to 19, 23 to 39 kW/K, and 0.019 to 0.023 for some standard heat exchanger configurations. Pressure-loss contributions to entropy generation were significant; the largest frictional contribution was 114% of the heat transfer irreversibility. Using conventional recuperator designs, the 0.95 effectiveness proved difficult to achieve without exceeding other performance targets; a metallic, plate-fin counterflow solution called for 15% more mass and 33% higher pressure-loss than the target values. Two types of gas-coolers showed promise. Single-pass counterflow and multipass cross-counterflow arrangements both met the 0.97 effectiveness requirement. Potential reliability-related advantages of the cross-counterflow design were noted. Cycle modifications, enhanced heat transfer techniques and incorporation of advanced materials were suggested options to reduce system development risk. Carbon-carbon sheeting or foam proved an attractive option to improve overall performance.

Barrett, Michael J.↗

Enhancement of operational Flexibility of Power Plants Using IN740

Headers are crucial components within diverse industries, especially in the energy sector, as they enable the efficient transfer of fluids. The selection of materials for headers is determined by their specific applications; for example, Grade 91 and Grade 92 steels are commonly utilized. In our research, we recommend the adoption of INCONEL alloy 740 due to its exceptional robustness and heat-resistant characteristics. One critical parameter in header systems is the heat transfer coefficient, which directly influences the efficiency of heat exchange processes and can thereby impact the structural integrity of the headers. This coefficient is closely linked with factors such as the Nusselt number, which is influenced by fluid flow characteristics and thermal properties. The flow direction within headers, whether unidirectional or multidirectional—significantly affects the overall dynamics of heat transfer. This research focuses on exploring the behavior of headers, a specific pipeline system component, using ANSYS simulation software. The study aims to predict heat transfer and mechanical behavior within headers under various conditions through steady-state and transient simulations (parts 1 and 2 of the report). Key parameters such as heat transfer coefficient, velocity, and temperature are examined with the goal of optimizing header design. Part 3 of the report addresses the critical yet underexplored relationship between pressure drop and heat transfer coefficients in the transient flow regime within headers, specifically focusing on smooth horizontal circular tubes. Limited experimental work has been conducted in this area, prompting the need for comprehensive analysis. By leveraging machine learning techniques, this research aims to establish a correlation between pressure drop and heat transfer across various flow conditions, including laminar, transient, quasi-turbulent, and turbulent regimes. The data utilized for this analysis were meticulously gathered from existing literature, capturing simultaneous measurements of pressure drops and heat transfer. Part 4: In the context of power plants, header pipes are essential components that significantly influence system performance by facilitating the collection and distribution of steam. This report highlights the critical role of header pipes in enhancing reliability, efficiency, and overall power plant performance. A key aspect of this investigation is shape optimization, which aims to maximize performance while minimizing material usage. By focusing on shape optimization, this research contributes to improved efficiency and a reduced environmental footprint for power plant installations. The methodology developed in this study emphasizes optimizing header shapes to decrease reliance on expensive alloy materials and lower maintenance costs. Furthermore, a case study was conducted using a header from an operational power plant to validate the proposed optimization techniques. Finally, part 5 addresses the challenges associated with flexible operations in boiler systems, the study outlines several strategies for enhancing the durability and reliability of steam headers. Key approaches include material selection, which involves utilizing advanced materials with superior high-temperature properties and enhanced fatigue resistance to extend the lifespan of steam headers. Design modifications are also recommended, focusing on implementing changes that mitigate thermal stress and cyclic loading to reduce the likelihood of failures under varying operating conditions. Additionally, the study emphasizes the importance of regular inspection and monitoring by establishing rigorous protocols to detect early signs of damage, allowing for timely maintenance and minimizing the risks of catastrophic failures. Furthermore, operational guidelines are developed to minimize the frequency and severity of thermal transients, ensuring stable and efficient operations. Collectively, these strategies provide a robust framework for overcoming the unique challenges posed by flexible operation in boiler systems, ultimately contributing to improved reliability and performance in power plant operations. Through this comprehensive approach, the study not only enhances the understanding of pressure drop and heat transfer relationships but also promotes advancements in design and operation that will benefit the entire power generation industry.

01 COAL, LIGNITE, AND PEAT↗

Performance Expectations of Closed-Brayton-Cycle Heat Exchangers in 100-kWe Nuclear Space Power Systems

Performance expectations of closed-Brayton-cycle heat exchangers to be used in 100-kWe nuclear space power systems were forecast. Proposed cycle state points for a system supporting a mission to three of Jupiter s moons required effectiveness values for the heat-source exchanger, recuperator and rejection exchanger (gas cooler) of 0.98,0.95 and 0.97, respectively. Performance parameters such as number of thermal units (Nm), equivalent thermal conductance (UA), and entropy generation numbers (Ns) varied from 11 to 19,23 to 39 kWK, and 0.019 to 0.023 for some standard heat exchanger configurations. Pressure-loss contributions to entropy generation were significant; the largest frictional contribution was 114% of the heat-transfer irreversibility. Using conventional recuperator designs, the 0.95 effectiveness proved difficult to achieve without exceeding other performance targets; a metallic, plate-fin counterflow solution called for 15% more mass and 33% higher pressure-loss than the target values. Two types of gas-coolers showed promise. Single-pass counterflow and multipass cross-counterflow arrangements both met the 0.97 effectiveness requirement. Potential reliability-related advantages of the cross-countefflow design were noted. Cycle modifications, enhanced heat transfer techniques and incorporation of advanced materials were suggested options to reduce system development risk. Carbon-carbon sheeting or foam proved an attractive option to improve overall performance.

Barrett, Michael J.↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

Alario, J.↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Transition correlation in subsonic flow over a flat plate

A 2D subsonic flow over a flat plate with a freestream Mach number M(infinity) up to 0.8 is considered. The flow can experience continuous uniform suction through the wall and the wall can be heated or cooled continuously with a fixed wall temperature. For a specific combination of M(infinity), suction velocity, and level of heat transfer, the mean flow problem is solved and linear stability calculations are performed to compute the location on the flat plate where the factor representing the integration of growth rates reaches nine. These calculations are repeated for several combinations of flow parameters and the theoretically predicted transition location is presented in the form of a correlation that can account for the effect of wall suction, heat transfer, and Mach number.

Masad, J. A.↗

Simulation of Hydrogen Flow in a Nuclear-Thermal Propulsion Reactor Subsystem: Conjugate Heat Transfer in Surrogate Fuel Elements and Flow Through the Dome Inlet to the Fuel Elements

NASA is performing research related to a Nuclear-Thermal Propulsion (NTP) engine as a step toward future manned missions to Mars. BWX Technologies (BWXT), in conjunction with NASA, is developing the reactor subsystem for that NTP engine design. As a subset of the reactor subsystem, the fuel elements have continued to evolve in design, as well. A set of experiments within the Nuclear Thermal Reactor Element Environmental Simulator at NASA Marshall has been developed to compliment that design process, including a series of surrogate fuel elements. Before the experiments of each surrogate can be completed, they must be deemed safe using structural analysis, which itself requires thermal and conjugate heat transfer analyses of the articles. Therefore, conjugate heat transfer simulations of the hydrogen flow through the test article fuel element surrogates were developed to provide estimates of heating, as well as to provide assessments of the fluid flow through the elements. The set of simulations involved not only the separate test conditions, but also a sensitivity study to estimate the effect of physical parameter uncertainty on the selected quantities of interest. Additionally, the fluid flow through the fore section inner plenum dome to the entrances of the fuel elements, another section of the reactor subsystem still under active development, was simulated and analyzed. The simulations show the extent of non-uniformity in the mass flow distribution across the dome outlets. Furthermore, additional analyses estimate the effects of required flow blockages on the potential development of flow dynamics. These analyses were used in the design cycle to make improvements to the reactor subsystem design.

Kalen E. Braman↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

Analytic Methods for Predicting Significant Multi-Quanta Effects in Collisional Molecular Energy Transfer

Collision-induced transitions can significantly affect molecular vibrational-rotational populations and energy transfer in atmospheres and gaseous systems. This, in turn. can strongly influence convective heat transfer through dissociation and recombination of diatomics. and radiative heat transfer due to strong vibrational coupling. It is necessary to know state-to-state rates to predict engine performance and aerothermodynamic behavior of hypersonic flows, to analyze diagnostic radiative data obtained from experimental test facilities, and to design heat shields and other thermal protective systems. Furthermore, transfer rates between vibrational and translational modes can strongly influence energy flow in various 'disturbed' environments, particularly where the vibrational and translational temperatures are not equilibrated.

Bieniek, Ronald J.↗

Calculation of two- and three-dimensional transonic cascade flow field using the Navier-Stokes equations

A Navier-Stokes analysis employing the time-dependent Linearized Block Implicit scheme (LBI) was applied to two-dimensional and three-dimensional transonic turbulent cascade flows. In general, the geometrical configuration of the turbine blade impacts both the grid construction procedure and the implementation of the numerical algorithm. Since modern turbine blades of interest are characterized by very blunt leading edges, rounded trailing edges and high stacking angles, a robust grid construction procedure is required that can accommodate the severe body shape while resolving regions of large flow gradients. A constructive O-type grid generation technique, suitable for cascades with rounded trailing edges, was developed and used to construct the C3X turbine cascade coordinate grid. Two-dimensional calculations were performed employing the Navier-Stokes procedure for the C3X turbine cascade, and the predicted pressure coefficients and heat transfer rates were compared with the experimental data. Three-dimensional Navier-Stokes calculations were also performed.

Weinberg, B. C.↗

Ultra-clear Aerogels for Insulated Glass in Refrigeration Doors (CRADA Final Report)

Display refrigerators commonly employ glass doors to provide product visibility; however, these doors exhibit significantly poorer thermal insulation than solid doors, resulting in increased heat transfer and higher energy consumption. To address this limitation, this project investigated the use of silica aerogel as a transparent insulating medium for refrigerator glass doors, with the objective of enhancing thermal performance without compromising visual clarity. In Phase I of the project, we assessed the feasibility of silica aerogel insulation through laboratory and full-scale studies, including material characterization, durability testing, and heat transfer measurements, along with the development and performance evaluation of prototype glass doors under realistic operating conditions. In Phase II, the project focused on scaling the technology toward practical deployment. This included scaling up the manufacturing process to achieve a surface area roughly 20 times larger for commercial applications, developing full-scale prototypes that integrated silica aerogel into standard display refrigerator doors, and conducting field evaluations to assess thermal performance, energy savings, and operational durability under real-world conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Evaluation of a Water Shield for a Surface Power Reactor

A water based shielding system is being investigated for use on initial lunar surface power systems. The use of water may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. A representative lunar surface reactor design is evaluated at various power levels in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The evaluation compares the experimental data from the WST to CFD models. Performance of a water shield on the lunar surface is predicted by CFD models anchored to test data, and by matching relevant dimensionless parameters.

Pearson, J. B.↗

Imaging for Hypersonic Experimental Aeroheating Testing (IHEAT) Version 4.0: User Manual

The IHEAT v4.0 software is a data reduction code for global thermography data acquired in the NASA Langley Aerothermodynamics Laboratory (LAL) hypersonic wind tunnels. IHEAT uses red and green color-intensity data from two-dimensional images of wind tunnel models to compute temperatures and heat-transfer rates using a semi-infinite, one-dimensional heat transfer approximation at each image pixel. Multiple automated tools in IHEAT v4.0 decrease the time required to reduce the data from a phosphor thermography wind tunnel run. Data at one or all of the image pixel locations can be exported to computer files for further analysis. The prior version of IHEAT, v3.2, was written in PV-WAVE® (now owned by Rogue Wave® Software) in 1994 and was limited in functionality to fit within the memory constraints of the available computers at the time. IHEAT v4.0 is written in MATLAB® by MathWorks® and contains several new features that leverage the increase in available memory of the current computers. A Piecewise tool permits the user to extract data along a segmented line cut that can follow interesting features in the image better than the single, straight line cuts that were possible with the legacy Length and Profile tools. The new Load Run and Batch tools facilitate batch processing by loading in all of the input files and images for a run at the same time. Load Run permits the user to process the available run images manually, while Batch automatically saves heat transfer data from all of the images based on the analysis previously performed on a single frame. IHEAT v4.0 also can automatically calculate the temporal collapse of reference line cuts from the time history heating data for a run to indicate the appropriate frame to reduce for each run. The IHEAT v4.0 source code was compiled into a standalone executable file that can be accessed remotely from several computers with different operating systems, simultaneously. The software is run through the MATLAB® Compiler Runtime engine, and therefore, IHEAT does not require a software license to run. Any software commands executed in the IHEAT v4.0 code will not affect other similar applications running on the same machine. Similarly, changes to the parent software do not affect a compiled code. These features of IHEAT v4.0 are improvements over the legacy v3.2 code, which required regular maintenance to avoid losing functionality as the PVWAVE ® programming language was upgraded.

Mason, Michelle L.↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗