Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The CMS Remote Analysis Builder (CRAB)

The CMS experiment will produce several Pbytes of data every year, to be distributed over many computing centers geographically distributed in different countries. Analysis of this data will be also performed in a distributed way, using grid infrastructure. CRAB (CMS Remote Analysis Builder) is a specific tool, designed and developed by the CMS collaboration, that allows a transparent access to distributed data to end physicist. Very limited knowledge of underlying technicalities are required to the user. CRAB interacts with the local user environment, the CMS Data Management services and with the Grid middleware. It is able to use WLCG, gLite and OSG middleware. CRAB has been in production and in routine use by end-users since Spring 2004. It has been extensively used in studies to prepare the Physics Technical Design Report (PTDR) and in the analysis of reconstructed event samples generated during the Computing Software and Analysis Challenge (CSA06). This involved generating thousands of jobs per day at peak rates. In this paper we discuss the current implementation of CRAB, the experience with using it in production and the plans to improve it in the immediate future.

99 GENERAL AND MISCELLANEOUS↗

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

Analysis of the Current Use, Benefit, and Value of the Open Science Grid

The Open Science Grid usage has ramped up more than 25% in the past twelve months due to both the increase in throughput of the core stakeholders - US LHC, LIGO and Run II - and increase in usage by nonphysics communities. It is important to understand the value collaborative projects, such as the OSG, contribute to the scientific community. This needs to be cognizant of the environment of commercial cloud offerings, the evolving and maturing middleware for grid based distributed computing, and the evolution in science and research dependence on computation. We present a first categorization of OSG value and analysis across several different aspects of the Consortium's goals and activities. And lastly, we presents some of the upcoming challenges of LHC data analysis ramp up and our ongoing contributions to the World Wide LHC Computing Grid.

99 GENERAL AND MISCELLANEOUS↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Shape optimization of single- and two-element airfoils on multiblock grids

A multiblock, discrete sensitivity analysis method is used to couple a direct optimization method and a flow analysis method. The domain is divided into smaller subdomains for which the sensitivities are obtained separately. Then, an effective sensitivity equation is solved to complete the coupling of all the sensitivity information. The flow analysis is based on the thin-layer Navier-Stokes equations solved by an implicit, upwind-biased, finite-volume method. The method of feasible directions is used for the present gradient-based optimization approach. First, a transonic airfoil is optimized to investigate the behavior of the method in highly nonlinear flows as well as the effect of different blocking strategies on the procedure. A supercritical airfoil is produced from an initially symmetric airfoil with multiblocking affecting the path but not the final shape. Secondly, a two-element airfoil is shape optimized in subsonic flow to demonstrate the present method's capability of shaping aerodynamically interfering elements simultaneously. For a very low and a very high Reynolds number cases, the shape of the main airfoil and the flap are optimized to yield improved lift-to-drag ratios.

Lacasse, James M.↗

Condenser Microphone Protective Grid Correction for High Frequency Measurements

Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

Lee, Erik↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Accuracy of Adaptive Grid Methods for Captured Shocks

The accuracy of two grid adaptation strategies, grid redistribution and local grid refinement, is examined by solving the 2-D Euler equations for the supersonic steady flow around a cylinder. Second- and fourth-order linear finite difference shock-capturing schemes, based on the Lax-Friedrichs flux splitting, are used to discretize the governing equations. The grid refinement study shows that for the second-order scheme, neither grid adaptation strategy improves the numerical solution accuracy compared to that calculated on a uniform grid with the same number of grid points. For the fourth-order scheme, the dominant first-order error component is reduced by the grid adaptation, while the design-order error component drastically increases because of the grid nonuniformity. As a result, both grid adaptation techniques improve the numerical solution accuracy only on the coarsest mesh or on very fine grids that are seldom found in practical applications because of the computational cost involved. Similar error behavior has been obtained for the pressure integral across the shock. A simple analysis shows that both grid adaptation strategies are not without penalties in the numerical solution accuracy. Based on these results, a new grid adaptation criterion for captured shocks is proposed.

Yamaleev, Nail K.↗

Size reduction of high- and low-moisture corn stalks by linear knife grid system

High- and low-moisture corn stalks were tested using a linear knife grid size reduction device developed for first-stage size reduction. The device was used in conjunction with a universal test machine that quantified shearing stress and energy characteristics for forcing a bed of corn stalks through a grid of sharp knives. No published engineering performance data for corn stover with similar devices are available to optimize performance; however, commercial knife grid systems exist for forage size reduction. From the force displacement data, mean and maximum ultimate shear stresses, cumulative and peak mass-based cutting energies for corn stalks, and mean new surface area-based cutting energies were determined from 4 5 refill runs at two moisture contents (78.8% and 11.3% wet basis), three knife grid spacings (25.4, 50.8, and 101.6 mm), and three bed depths (50.8, 101.6, and 152.4 mm). In general, the results indicated that peak failure load, ultimate shear stress, and cutting energy values varied directly with bed depth and inversely with knife grid spacing. Mean separation analysis established that high- and low-moisture conditions and bed depths 101.6 mm did not differ significantly (P < 0.05) for ultimate stress and cutting energy values, but knife grid spacing were significantly different. Linear knife grid cutting energy requirements for both moisture conditions of corn stalks were much smaller than reported cutting energy requirements. Ultimate shear stress and cutting energy results of this research should aid the engineering design of commercial scale linear knife gird size reduction equipment for various biomass feedstocks.

09 BIOMASS FUELS↗

Variational four-dimensional analysis using quasi-geostrophic constraints

A variational four-dimensional analysis technique using quasi-geostrophic models as constraints is examined using gridded fields as data. The analysis method uses a standard iterative nonlinear minimization technique to find the solution to the constraining forecast model which best fits the data as measured by a predefined functional. The minimization algorithm uses the derivative of the functional with respect to each of the initial condition values. This derivative vector is found by inserting the weighted differences between the model solution and the inserted data into a backwards integrating adjoint model. The four-dimensional analysis system was examined by applying it to fields created from a primitive equations model forecast and to fields created from satellite retrievals. The results show that the technique has several interesting characteristics not found in more traditional four-dimensional assimilation techniques. These features include a close fit of the model solution to the observations throughout the analysis interval and an insensitivity to the frequency of data insertion or the amount of data. The four-dimensional analysis technique is very versatile and can be extended to more complex problems with little theoretical difficulty.

Derber, John C.↗

Variable Electricity from Base-load Nuclear Power Plants Using Stored Heat

Restrictions on greenhouse gas emissions and growth of renewables change the price structure of electricity markets with more hours per year of low electricity prices and high electricity prices. This creates large economic incentives to (1) store energy at times of low electricity prices to produce electricity when prices are high and (2) couple base-load nuclear plants to heat storage to avoid selling electricity at times of low prices and increase electricity sales at times of high prices. Nuclear energy coupled with thermal energy storage has potentially superior economics to alternative energy storage technologies for peak electricity production because (1) heat storage is cheaper than electricity storage, (2) economics of scale for energy storage, (3) more storage cycles per year and (4) dispatchable electricity generation that avoids full depletion of energy storage systems. Nuclear with heat storage is potentially the enabling technology for a zero-carbon nuclear renewable electricity grid. The changing electricity market, nuclear thermal energy storage options, and market analysis using the Texas electricity grid as an example are described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid structured/unstructured grid computations for the F/A-18 at high angle of attack

At high angles of attack, vortical flows play a crucial role in the maintenance of lift for fighter aircraft. However, under certain conditions, the vortical flow can have an adverse effect on the aircraft. On the F/A-18 the LEX vortex can impinge on the tail; at high angles of attack the unsteady flow from vortex bursting can cause structural fatigue on the vertical tails. At high angles of attack, the flow field can be quite complex, and a computational analysis challenging. A full configuration analysis with viscous structured grids can be computationally expensive and the task of generating the requisite grids can be quite difficult. To mitigate these difficulties and provide a medium-fidelity analysis tool, a hybrid structured/unstructured approach was adopted for this work. In this analysis, the formation and roll-up of the LEX vortex is computed with a structured Navier-Stokes solver, and the resulting vortex propagated downstream with an unstructured Euler solver.

Robert T Biedron↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗

Analysis of Electric Vehicle Charging Impact on the Electric Power Grid

In order to evaluate the impact of electric vehicles (EVs) on the distribution grid and assess their potential benefits to the future smart grid, it is crucial to study the EV charging patterns and the usage charging station. Though EVs are not yet widely adopted nationwide, a valuable methodology to conduct such studies is the statistical analysis of real-world charging data. This paper presents actual EV charging behavior of 64 EVs (5 brands, 8 models) from EV users and charging stations at Los Angeles Department of Water and Power for more than one year. Twenty-four-hour EV charging load curves have been generated and studied for various load periods: daily, monthly, seasonally and yearly. Finally, the effect and impact of EV load on the California distribution network are evaluated at different EV penetration rates.

33 ADVANCED PROPULSION SYSTEMS↗

Quantification of phosphorus in single cells using synchrotron X-ray fluorescence

Phosphorus is required for numerous cellular compounds and as a result can serve as a useful proxy for total cell biomass in studies of cell elemental composition. Single-cell analysis by synchrotron X-ray fluorescence (SXRF) enables quantitative and qualitative analyses of cell elemental composition with high elemental sensitivity. Element standards are required to convert measured X-ray fluorescence intensities into element concentrations, but few appropriate standards are available, particularly for the biologically important element P. Empirical P conversion factors derived from other elements contained in certified thin-film standards were used to quantify P in the model diatom Thalassiosira pseudonana, and the measured cell quotas were compared with those measured in bulk by spectrophotometry. The mean cellular P quotas quantified with SXRF for cells on Au, Ni and nylon grids using this approach were not significantly different from each other or from those measured spectrophotometrically. Inter-cell variability typical of cell populations was observed. Additionally, the grid substrates were compared for their suitability to P quantification based on the potential for spectral interferences with P. Nylon grids were found to have the lowest background concentrations and limits of detection for P, while background concentrations in Ni and Au grids were 1.8- and 6.3-fold higher. The advantages and disadvantages of each grid type for elemental analysis of individual phytoplankton cells are discussed.

54 ENVIRONMENTAL SCIENCES↗

Mechanism Analysis of Wind Turbine Var Oscillations

Electromagnetic transient simulation of parallel connected 4-MW type-3 wind turbines based on original equipment manufacturer's real-code turbine model shows 1.2-Hz turbine-turbine oscillations in reactive power. This letter reveals why such oscillations occur in the individual var measurement, while being insignificant in the total var measurement, regardless of the varying grid impedance. We adopt two analysis approaches: open-loop single-input single-output analysis and network decomposition. The two approaches differ in their treatment of turbine-network interaction. The open-loop analysis shows that the turbine-turbine oscillation mode is due to an open-loop system pole being attracted to an open-loop system zero. Furthermore, we use network decomposition method to explain why this mode is observable in individual vars while not observable in the total var. The entire system of n -turbines can be viewed as n decoupled circuits. For the two-turbine case, the system has an aggregated mode and a turbine-turbine oscillation mode. Here, the aggregated mode is associated with a circuit associated with the total var, while the turbine-turbine oscillation mode is associated with the var difference and is insensitive to the grid parameters.

17 WIND ENERGY↗

Analysis of pre-flight modulator voltage calibration data for the Voyager plasma science experiment

The Voyager Plasma Science (PLS) modulator calibration (MVM) data analysis was undertaken in order to check the correctness of the fast A/D converter formulas that connect low voltage monitor signals (MV) with digital outputs (DN), to determine the proportionality constants between the actual modulator grid potential (V) and the monitor voltage (MV), and to establish an algorithm to link the digitized readouts (DN) with the actual grid potential (V). The analysis results are surprising in that the derived conversion constants deviate by fairly significant amounts from their nominal values. However, it must be kept in mind that the test results which were used for analysis may be very imprecise. Even if it is assumed that the test result errors are very large, they do no appear to be capable to account for all discrepancies between the theoretical expectations and the results of the analysis. Measurements with the flight spare instrument appear to be the only means of investigating these effects further.

Nastov, Ognen↗