Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GROUNDWATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Heavy metals and trace elements in the groundwater in El Paso, Texas

The chemical elements studied here (Al, As, Ba, Cd, Cr, Cu, Fe, Pb, Mn, Hg, Ni, Se, Ag, Zn, Li, B) include toxic heavy metals and non-toxic elements which have occurred at high levels in El Paso, TX groundwater (Fe, Cu, Mn, As, Pb; up to 24,000, 17,000, 3200, 95, and 1000 ppb respectively). The objective of this study is to investigate the origins of these heavy metals in the groundwater. Previous works found some of these metals in the rocks of the mountains that recharge the watershed, and sufficient evidence for natural origins of arsenic in the groundwater. Statistical analyses in this report are consistent with natural origin also for the heavy metals studied but cannot dismiss human activity as a contributing factor. Interesting correlations with R-value>0.60, p-value<0.01 warrant further analysis.

Marquez B, Elia↗

Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116

An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated system as an alternative to traditional sample collection and analysis includes the following: - Field observations that provide more characterization information than is possible using traditional monitoring methods. - Potentially significant reductions in labor and analytical costs if traditional methods are complemented by automated systems. - The reduced cost of acquiring samples will allow for more frequent collection of samples that may be automatically introduced into real-time graphical flux programs allowing site managers to observe the changes in contaminant concentrations during remediation projects and across discrete river stage events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radon Concentration in Groundwater in the Central Region of Gyeongju, Korea - 13130

Radon is a naturally occurring radioactive gas that is a well known cause of lung cancer through inhalation. Nevertheless, stomach cancer can also occur if radon-containing water is ingested. This study measured the radon concentration in groundwater for drinking or other domestic uses in the central region of Gyeongju, Korea. The groundwater samples were taken from 11 points chosen from the 11 administrative districts in the central region of Gyeongju by selecting a point per district considering the demographic distribution including the number of tourists who visit the ancient ruins and archaeological sites. The mean radon concentrations in the groundwater samples ranged from 14.38 to 9050.73 Bq.m{sup -3}, which were below the recommendations by the U.S. EPA and WHO. (authors)

54 ENVIRONMENTAL SCIENCES↗

Thermal Removal of Tritium from Concrete and Soil to Reduce Groundwater Impacts - 13197

Legacy heavy-water moderator operations at the Savannah River Site (SRS) have resulted in the contamination of equipment pads, building slabs, and surrounding soil with tritium. At the time of discovery the tritium had impacted the shallow (< 3-m) groundwater at the facility. While tritium was present in the groundwater, characterization efforts determined that a significant source remained in a concrete slab at the surface and within the associated vadose zone soils. To prevent continued long-term impacts to the shallow groundwater a CERCLA non-time critical removal action for these source materials was conducted to reduce the leaching of tritium from the vadose zone soils and concrete slabs. In order to minimize transportation and disposal costs, an on-site thermal treatment process was designed, tested, and implemented. The on-site treatment consisted of thermal detritiation of the concrete rubble and soil. During this process concrete rubble was heated to a temperature of 815 deg. C (1,500 deg. F) resulting in the dehydration and removal of water bound tritium. During heating, tritium contaminated soil was used to provide thermal insulation during which it's temperature exceeded 100 deg. C (212 deg. F), causing drying and removal of tritium. The thermal treatment process volatiles the water bound tritium and releases it to the atmosphere. The released tritium was considered insignificant based upon Clean Air Act Compliance Package (CAP88) analysis and did not exceed exposure thresholds. A treatability study evaluated the effectiveness of this thermal configuration and viability as a decontamination method for tritium in concrete and soil materials. Post treatment sampling confirmed the effectiveness at reducing tritium to acceptable waste site specific levels. With American Recovery and Reinvestment Act (ARRA) funding three additional treatment cells were assembled utilizing commercial heating equipment and common construction materials. This provided a total of four units to batch treat concrete rubble and soil. Post treatment sampling verified that the activity in the treated soil and concrete met the treatment standards for each medium which allowed the treated concrete rubble and soil to be disposed of on-site as backfill. During testing and operations a total of 1,261-m{sup 3} (1,650-yd{sup 3}) of contaminated concrete and soils were treated with an actual incurred cost of $3,980,000. This represents a unit treatment cost of $3,156/m{sup 3} ($2,412/yd{sup 3}). In 2011 the project was recognized with an e-Star Sustainability Award by DOE's Office of Environmental Management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mann-Kendall Test for Analysis of Groundwater Contaminant Plume Stability and Evaluation of Sampling Frequency for Long-Term Monitoring - 13233

This paper describes a spreadsheet-based approach for applying the Mann-Kendall (MK) Test to identify statistically significant increasing or decreasing concentration trends, stable concentration trends (not increasing or decreasing), and indeterminate concentration trends (no trend) defined by time-series groundwater monitoring data for inorganic, organic, or radiological contaminants. The approach has been applied in support of ongoing long-term monitoring (LTM) of groundwater contamination at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee and elsewhere on the DOE Oak Ridge Reservation (ORR), and has proven effective at minimizing subjective bias in the evaluation and interpretation of contaminant concentration trend data. Application of the approach for the purposes of optimizing groundwater sampling frequency for LTM also is outlined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influences on Effective Decay Rates of Radionuclides in Groundwater: F-Area Seepage Basins, Savannah River Site - 17149

Effective decay rates for radionuclides incorporate all attenuation mechanisms and are useful for assessing the progress of natural or enhanced attenuation. If a concentration versus time trend at a given monitoring well behaves according to first-order decay, then an effective decay constant can be calculated from the slope of the linear trend. It is important to view time trends in terms of all possible processes that can affect them prior to evaluating effective decay rates, because changes to groundwater flow and attenuation processes influence the rate at which contaminant concentrations decrease. In addition, other factors can lead to apparent changes in the effective decay rate. Groundwater associated with the F-Area Seepage Basins at the Savannah River Site in South Carolina provides an excellent case study for examining processes that affect concentration versus time trends and some of the pitfalls in evaluating effective decay rates. The site has an extensive groundwater monitoring database and its history is well known. The objective of this case study is to highlight the importance of viewing a site holistically in any evaluation of effective decay rates, because what is obvious at the F-Area Seepage Basins may not be obvious at sites with sparser monitoring data and more obscure histories. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated program for department of energy environmental management office of soil and groundwater remediation - 15426

The subsurface problems that remain at the U.S. Department of Energy (DOE) Office of Environmental Management (EM) sites are technically complex and the costs to complete the cleanup mission are expected to range from $17 billion to $21 billion. There is growing recognition that conventional remedies will not meet regulatory goals at a number of sites and alternative approaches will be required. To address the challenge, the EM Office of Soil and Groundwater Remediation created an integrated program to develop innovative scientific and technical in conjunction with engagement of stakeholders, regulators, and the public. The integrated program provides a holistic approach to assess the risk associated with the remaining challenges facing EM and develop solutions that achieve remediation goals and protect human health and the environment. The integrated program uses a systems-based framework for achieving environmental remediation goals. The framework is based on developing and updating a site conceptual model and includes steps to 1) provide the technical basis for remedial actions, 2) assessments of potential remedies, and 3) implementation and management of remedies to achieve site restoration goals. The Office of Soil and Groundwater remediation defines research and development needed to successfully define and apply the framework. Research opportunities and targets are identified in characterization and conceptual model development, predictions of site conditions, remediation, monitoring, and remediation decision support. Characterization and quantification of key subsurface uncertainties is needed to support conceptual model development, identify contaminant source zones, quantify the flux of contaminants from source terms to points of compliance, and characterize controlling processes for remediation approaches including natural attenuation. Predictive analyses are needed to support development of remediation endpoints, select and design active and in situ or passive remedies, assess remedy performance, and predict long-term contaminant behavior for design of monitoring systems. Advancements are needed to support adaptive remediation approaches and to develop long-term contaminant management strategies for complex sites, such as effective in situ treatment methods for long-lived contaminants ({sup 99}Tc, {sup 129}I, U, Hg, etc.). Monitoring tools and approaches are needed to evaluate remedy performance and plume behavior and decision support methods are needed to quantitatively evaluate remediation alternatives. The Office of Soil and Groundwater Remediation leverages scientific understanding provided through partnerships with the DOE Office of Science, the Department of Defense, and Environmental Protection Agency. These partnerships are helping EM develop scientific understanding and technologies for implementing the assessment framework. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of multiple groundwater contaminant plumes extending beyond property boundaries at the young - Rainey STAR Center (Science, Technology, and Research Center) - 15623

The US DOE Pinellas Plant-now known as the Young - Rainey STAR Center, located in Largo, Florida-manufactured components for nuclear weapons from 1956 to 1995. During decades of operations, chlorinated solvents were released from a drum storage area and from underground piping at multiple points adjacent to and beneath a 4.5-hectare (11-acre) building. Two groundwater contaminant plumes associated with contaminant sources beneath the building have been identified, delineated, and are being monitored. During a focused delineation campaign in 2008 to better define the plume boundaries prior to municipal construction projects in the area, the plumes were determined to extend beyond the site boundaries, beneath the adjacent roadway easements, and beneath four adjacent privately owned properties. US DOE has performed a number of activities in response to the discovery of the offsite contaminant plumes, including performing a high-resolution delineation of contaminant plumes; coordinating with local municipalities to complete two linear construction projects requiring dewatering in the vicinity of the plumes; performing risk assessment, risk management, risk communication, and community relations tasks associated with the project; coordinating with state regulators to identify a risk-based corrective action regulatory approach; and coordinating with impacted property owners to develop and implement institutional controls. During the replacement of a 1.2-meter (48-inch) municipal potable water line directly over the contaminant plume area, US DOE (1) constructed infrastructure to receive and treat dewatering effluent at a rate of 20 gallons per minute around the clock for 6 weeks, and (2) conducted breathing-zone air monitoring during excavation of a 3.0-meter (10-foot) deep trench. This degree of diligence was necessary to ensure and document that no site workers were exposed to chlorinated solvent vapors during the construction process, and that a large volume of potentially contaminated groundwater was properly treated and dispositioned. US DOE also took aggressive actions to pro-actively address claims regarding loss of property value on two properties associated with the groundwater contamination, which resulted in a teaming arrangement with each party for future management of the ongoing corrective actions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of dominant hydrogeochemical processes influencing uranium transport in groundwater at a retired explosives test site - 15727

The Lawrence Livermore National Laboratory (LLNL) Site 300 facility was established in 1955 to support US weapons research and development. Open-air explosives tests, that used depleted uranium as a proxy, were conducted at the Building 812 site. Depleted uranium was released into the environment, eventually migrating into the underlying sandstone bedrock aquifer. At the site, groundwater concentrations of uranium exceed the California Maximum Contaminant Level of 20 pico-Curies per liter (pCi/L). However, the groundwater contaminant plume appears to attenuate within 60 meters of the contaminant source, beyond which no depleted uranium is observed. The goal of this research is to determine the processes (i.e., sorption to mineral surfaces, biotransformation, diffusion, dispersion, and mineral precipitation) controlling attenuation of uranium in local groundwater. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater Monitoring Guidance for Decommissioning Planning - 16228

The Electric Power Research Institute (EPRI) is preparing a document called Groundwater Monitoring Guidance for Decommissioning Planning. This guidance is the first part of a multi-year EPRI project which summarizes experiences with both operational and decommissioning groundwater protection programs and compares the two in order to identify data gaps. The EPRI guidance will show how to address these data gaps and provide recommended decommissioning preparatory actions. The second part of this project will addresses the long term stewardship of a groundwater protection program after the permanent shutdown of the plant during the SAFSTOR period and/or during the active decommissioning of the plant. This paper will discuss the content of the first EPRI guidance document that is focused on decommissioning planning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Basis and Implementation of Groundwater Pathway Models Used for INL's RH LLW Disposal Facility Performance Assessment - 19440

The Idaho National Laboratory's (INL's) Remote-Handled Low-Level Waste (RH LLW) Disposal Facility has been designed and constructed to receive waste generated by INL in support of the Office of Nuclear Energy (NE) and Naval Reactors (NR) missions. RH LLW is generated on the INL site from spent nuclear fuel handling and operations at the Naval Reactors Facility (NRF), the Advanced Test Reactor (ATR), and at the Material and Fuels Complex (MFC) in addition to other miscellaneous research activities. The facility has been designed to receive RH LLW currently in storage at INL facilities and new waste generated by nuclear research programs. RH LLW received at the facility is solid waste consisting of surface contaminated materials, ion exchange resins used to purify cooling water, and activated metals generated during reactor core change outs, Naval spent fuel management, and nuclear R and D. The facility has been designed to meet the requirements of DOE Order 435.1, Radioactive Waste Management for all-pathways including groundwater and air, radon emissions limits, and inadvertent intrusion limits. The facility design includes a vault system incorporating robust concrete vaults oriented vertically in close-packed arrays, a hydraulic drainage system designed to limit water contact with the stainless steel waste canisters and concrete vaults, and a robust monitoring system. Per the environmental assessment (EA), all waste will be disposed of in stainless steel waste canisters. During facility design and construction, site-specific data was collected to provide laboratory and field scale performance characteristics for the concrete vault and hydraulic drainage systems. Field-scale infiltration tests were conducted and monitoring data was interpreted using numerical simulation. Based on interpretation of the observed laboratory and field test data, the facility performance assessment (PA) was developed. The PA groundwater pathway source release model differentially credits release from surface contaminated waste, ion exchange resins, and activated metals. It also credits steel waste canisters with failure rates based on actual corrosion data. Once released, radionuclide transport through the vadose zone and aquifer to downgradient receptor locations was simulated in the PA using a one-dimensional modeling approach based on three-dimensional modeling of historically-contaminated INL sites. This paper provides an overview of the groundwater pathway source release models and their technical implementation in the PA. It also describes the one-dimensional transport model used for the vadose zone and multi-dimensional model used for the aquifer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geochemical Reactions Controlling Contaminant Transport in Groundwater at a Former Uranium Mill Site - 19576

The historical operation of a uranium mill near Tuba City, Arizona, contaminated the underlying groundwater. Initial characterization led to a compliance strategy using groundwater extraction and treatment, which operated from 2002 through 2014. Remediation progress was inhibited primarily by aquifer productivity. Geochemical testing was undertaken to better understand future potential for contaminant plume migration. Results indicated the presence of solid-phase uranium in the subsurface, which can continue to feed the groundwater plume, along with limited uranium sorption on uncontaminated material. Future transport modeling will incorporate the laboratory-quantified geochemical reactions and be used to evaluate site compliance strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ISR Restoration Methods and Applicability to Groundwater Remediation at Abandoned Uranium Mills - 20342

There are numerous abandoned uranium mining and mill sites in the southwestern US. Surface remediation was undertaken in the 1980's and 90's to cover mill tailings and minimize infiltration of meteoric precipitation into the subsurface These actions have reduced the availability of tailings contaminants but many of these sites have persistent groundwater contamination, primarily due to the disposal of tailings and process fluids in unlined impoundments during the mill's operational life. Active in situ recovery (ISR) uranium mining and wellfield restoration practices are examined to determine the factors that contribute to the success of groundwater restoration. Hydrologic characteristics, geochemistry, ore body quality, regulatory requirements and the aboveground components of uranium production and water treatment are considered. While there is no such thing as a typical abandoned mill site, the potential use of ISR restoration methods is evaluated for viability as a remedial alternative to mine and mill sites that have residual contaminated groundwater plumes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Method to Identify Groundwater Affected By Redox Conditions at Los Alamos National Laboratory Legacy Cleanup Site - 20497

To facilitate the mission of the Department of Energy's (DoE's) Environmental Management Program at Los Alamos National Laboratory (LANL), a significant number of groundwater monitoring wells with depths ranging from 152-396 meter were completed for characterization and monitoring. Groundwater at Los Alamos tends to be oxygen saturated with very low concentrations of organic matter. Drilling fluids can introduce residual carbon causing an increase in microbial activity and local reducing conditions around the well, potentially impacting representativeness of groundwater data quality for redox sensitive constituents. We assert that the redox state of the wells can robustly be identified by aqueous solution concentrations of iron and manganese. An automated review process has been built into a computer-based data management system enabling an efficient screening process for identifying reducing conditions that are not caught using standard data-validation protocol, and ensures that important data quality issues are thoroughly identified and addressed in an efficient and timely manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Supplemental Groundwater Remediation Technologies to Protect the Columbia River at Hanford, WA

Nine projects have been recently selected by the US Department of Energy (EM-22) to address groundwater contaminant migration at the Hanford Site. This paper summarizes the background and objectives of these projects. Five of the selected projects are targeted at hexavalent chromium contamination in Hanford 100 Area groundwater. These projects represent an integrated approach towards identifying the source of hexavalent chromium contamination in the Hanford 100-D Area and treating the groundwater contamination. Currently, there is no effective method to stop strontium-90 associated with the riparian zone sediments from leaching into the river. Phytoremediation may be a possible way to treat this contamination. Its use at the 100-N Area will be investigated. Another technology currently being tested for strontium-90 contamination at the 100-N Area involves injection (through wells) of a calcium-citrate-phosphate solution, which will precipitate apatite, a natural calcium-phosphate mineral. Apatite will adsorb the strontium-90, and then incorporate it as part of the apatite structure, isolating the strontium-90 contamination from entering the river. This EM-22 funded apatite project will develop a strategy for infiltrating the apatite solution from ground surface or a shallow trench to provide treatment over the upper portion of the contaminated zone, which is unsaturated during low river stage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Functional gene array-based analysis of microbial community structure in groundwater with gradient of contaminant levels

To understand how contaminants affect microbial community diversity, heterogeneity, and functional structure, six groundwater monitoring wells from the Field Research Center of the U.S. Department of Energy Environmental Remediation Science Program (ERSP; Oak Ridge, TN), with a wide range of pH, nitrate, and heavy metal contamination were investigated. DNA from the groundwater community was analyzed with a functional gene array containing 2006 probes to detect genes involved in metal resistance, sulfate reduction, organic contaminant degradation, and carbon and nitrogen cycling. Microbial diversity decreased in relation to the contamination levels of the wells. Highly contaminated wells had lower gene diversity but greater signal intensity than the pristine well. The microbial composition was heterogeneous, with 17?70% overlap between different wells. Metal-resistant and metal-reducing microorganisms were detected in both contaminated and pristine wells, suggesting the potential for successful bioremediation of metal-contaminated groundwaters. In addition, results of Mantel tests and canonical correspondence analysis indicate that nitrate, sulfate, pH, uranium, and technetium have a significant (p < 0.05) effect on microbial community structure. This study provides an overall picture of microbial community structure in contaminated environments with functional gene arrays by showing that diversity and heterogeneity can vary greatly in relation to contamination.

59 BASIC BIOLOGICAL SCIENCES↗

AUTOMATING GROUNDWATER SAMPLING AT HANFORD THE NEXT STEP

Historically, the groundwater monitoring activities at the Department of Energy's Hanford Site in southeastern Washington State have been very "people intensive." Approximately 1500 wells are sampled each year by field personnel or "samplers." These individuals have been issued pre-printed forms showing information about the well(s) for a particular sampling evolution. This information is taken from 2 official electronic databases: the Hanford Well information System (HWIS) and the Hanford Environmental Information System (HEIS). The samplers used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and other personnel posted the collected information onto a spreadsheet that was then printed and included in a log book. The log book was then used to make manual entries of the new information into the software application(s) for the HEIS and HWIS databases. A pilot project for automating this extremely tedious process was lauched in 2008. Initially, the automation was focused on water-level measurements. Now, the effort is being extended to automate the meta-data associated with collecting groundwater samples. The project allowed electronic forms produced in the field by samplers to be used in a work flow process where the data is transferred to the database and electronic form is filed in managed records - thus eliminating manually completed forms. Elimating the manual forms and streamlining the data entry not only improved the accuracy of the information recorded, but also enhanced the efficiency and sampling capacity of field office personnel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium-series constraints on radionuclide transport and groundwater flow at the Nopal I uranium deposit, Sierra Pena Blanca, Mexico

Uranium-series data for groundwater samples from the Nopal I uranium ore deposit were obtained to place constraints on radionuclide transport and hydrologic processes for a nuclear waste repository located in fractured, unsaturated volcanic tuff. Decreasing uranium concentrations for wells drilled in 2003 are consistent with a simple physical mixing model that indicates that groundwater velocities are low ({approx}10 m/y). Uranium isotopic constraints, well productivities, and radon systematics also suggest limited groundwater mixing and slow flow in the saturated zone. Uranium isotopic systematics for seepage water collected in the mine adit show a spatial dependence which is consistent with longer water-rock interaction times and higher uranium dissolution inputs at the front adit where the deposit is located. Uranium-series disequilibria measurements for mostly unsaturated zone samples indicate that {sup 230}Th/{sup 238}U activity ratios range from 0.005-0.48 and {sup 226}Ra/{sup 238}U activity ratios range from 0.006-113. {sup 239}Pu/{sup 238}U mass ratios for the saturated zone are <2 x 10{sup -14}, and Pu mobility in the saturated zone is >1000 times lower than the U mobility. Saturated zone mobility decreases in the order {sup 238}U{approx}{sup 226}Ra > {sup 230}Th{approx}{sup 239}Pu. Radium and thorium appear to have higher mobility in the unsaturated zone based on U-series data from fractures and seepage water near the deposit.

54 ENVIRONMENTAL SCIENCES↗