Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

STS atmospheric luminosities

During the STS-8 space shuttle mission special photographic and TV operations were carried out to record the properties of the spacecraft induced luminosities. One of these luminous phenomena is the quiescent vehicle glow which was photographed during the STS-8 mission with an image intensified photographic camera, with and without an objective grating. During the latter part of the mission the altitude of the shuttle was relatively low (120 n.m. = 222 km) and unprecedentedly high intensity of the glow was observed. The crew reported that the glow was easily visible to the naked eye. The proper orientation of the shuttle with respect to the velocity vector and the objective grating permitted the exposure of good objective spectrum of the glow in the visible region. From the results it is clear that the spectrum appears to be a continuum as observed by the image intensifier objective grating camera. Qualitative examination of the data shows that there is very tail little glow ion the wavelength range of 4300 to about 5000 angstroms. Above 5000 angstroms the glow becomes stronger towards the red and then it falls off towards higher wavelength and of the spectrum presumably because of the responsivity of the device.

Mende, S. B.↗

Layered synthetic microstructure technology considerations for the extreme ultraviolet

It is demonstrated that layered synthetic microstructures (LSMs) can provide mirrors with enhanced normal incidence reflectance in the 300-A spectral region. Experimental results are presented for Pt-Si and Ir-Si structures fabricated by electron-beam deposition at pressures of about 10 to the -6th Torr, and it is shown that the enhancement is realized over a limited bandwidth of 75 A. One potential application of LSMs is their use as coatings on diffraction gratings to enhance normal incidence reflection efficiencies. Preliminary results for the Ir-Si combination on a diffraction grating show that LSMs enhance grating efficiencies in the EUV by a factor of about 3.

Keski-Kuha, R. A. M.↗

An analysis of scattered light in low dispersion IUE spectra

A detailed numerical simulation of light scattering from the low-resolution grating in the short wavelength spectrograph of the IUE Observatory was developed, in order to quantitatively analyze the effects of scattering on both continuum and line emission spectra. It is found that: (1) the redistribution of light by grating scattering did not appreciably alter either the shape or the absolute flux level of continuum spectra for A-F stars; (2) late-type stellar continua showed a tendency to flatten when observed in scattered light toward the shorter wavelengths; and (3) the effect of grating scattering on emission lines is to decrease measured line intensities by an increasing percentage toward the shorter wavelengths. The spectra obtained from scattering experiments for solar-type and late type stars are reproduced in graphic form.

Basri, G.↗

Spatial-frequency spectrum of patterns changes the visibility of spatial-phase differences

It is shown that spatial-frequency components over a 4-octave range affected the visibility of spatial-phase differences. Contrast thresholds were measured for discrimination between two (+45- and -45-deg) spatial phases of a sinusoidal test grating added to a background grating. The background could contain one or several sinusoidal components, all in 0-deg phase. Phase differences between the test and the background were visible at lower contrasts when test and background frequencies were harmonically related than when they were not, when test and background frequencies were within 1 octave than when they were farther apart, when the fundamental frequency of the background was low than when it was high, and for some discriminations more than for others, after practice. The visibility of phase differences was not affected by additional components in the background if the fundamental and difference frequencies of the background remained unchanged. Observers' reports of their strategies gave information about the types of attentive processing that were used to discriminate phase differences. Attentive processing facilitated phase discrimination for multifrequency gratings spanning a much wider range of spatial frequencies than would be possible by using only local preattentive processing. These results were consistent with the visibility of phase differences being processed by some combination of even- and odd-symmetric simple cells tuned to a wide range of different spatial frequencies.

Lawton, T. B.↗

Gallium arsenide solar cell efficiency: Problems and potential

Under ideal conditions the GaAs solar cell should be able to operate at an AMO efficiency exceeding 27 percent, whereas to date the best measured efficiencies barely exceed 19 percent. Of more concern is the fact that there has been no improvement in the past half decade, despite the expenditure of considerable effort. State-of-the-art GaAs efficiency is analyzed in an attempt to determine the feasibility of improving on the status quo. The possible gains to be had in the planar cell. An attempt is also made to predict the efficiency levels that could be achieved with a grating geometry. Both the N-base and the P-base BaAs cells in their planar configurations have the potential to operate at AMO efficiencies between 23 and 24 percent. For the former the enabling technology is essentially in hand, while for the latter the problem of passivating the emitter surface remains to be solved. In the dot grating configuration, P-base efficiencies approaching 26 percent are possible with minor improvements in existing technology. N-base grating cell efficiencies comparable to those predicted for the P-base cell are achievable if the N surface can be sufficiently passivated.

Weizer, V. G.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Design and status of the detector block for the ISO-SWS

The Short Wave Spectrometer (SWS) is one of the two spectrometers for the Infrared Space Observatory (ISO). It consists of a pair of grating spectrometers and a Fabry-Perot interferometer. Together, the grating spectrometers cover the wavelength range 2.4 to 45 microns, at a resolution between 1000 and 2000. The Fabry-Perot interferometer, in series with one of the grating spectrometers, provides a resolution of about 20,000 at the wavelengths between 15 and 35 microns. The SWS is being built by the Space Research Organization of the Netherlands and the Max Planck Institute for Extraterrestrial Physics in Garching, Germany. The spectrometer has 52 discrete detectors, most of which are bulk detectors. In the design of the spectrometer, the main emphasis is on the sensitivity of the individual channels, rather than on the number of detectors. This was one of the main reasons to select non-destructive read-out circuits, with a separate heated-JFET pre-amplifier for each individual detector. The signals are amplified and filtered in parallel. The engineering tests on the SWS detector block have not yet been completed. The design of the detector block is described and the present problem areas are indicated.

Luinge, W.↗

Constant-dispersion grism spectrometer for channeled spectra

A new spectrometer design is presented in which the angular dispersion with respect to wave number is nearly constant. The spectrometer is a type of grism, a series combination of grating and prism, in which the constant parts of the dispersion terms add to one another but the slopes of the dispersions tend to cancel one another. A systematic method is presented for optimizing the grating and prism parameters. A cross-dispersion technique is presented, eliminating overlapping grating orders. A design example is given for the visible region from 0.45 to 0.80 micron with essentially constant wave-number dispersion and a peak transmission of approximately 95 percent. This grism is well suited for measuring channeled spectra as generated by an optical stellar interferometer.

Traub, Wesley A.↗

Effect of contrast on the perceived direction of a moving plaid

A series of experiments examining the effect of contrast on the perception of moving plaids is performed. This was done to test the hypothesis put forth by Adelson and Movshon (1982) that the human visual system determines the direction of a moving plaid in a two-staged process: decomposition into component motion followed by application of the intersection of constraints rule. When the gratings within the plaid are of different contrast, the perceived direction is not predicted by the intersection of constraints rule. There is a strong (up to 20 deg) bias in the direction of the higher-contrast grating. A revised model, which incorporates a contrast-dependent weighting of perceived grating speed as observed for one-dimensional patterns (Thompson, 1982), can quantitatively predict most of the results. Results are discussed in the context of various models of human visual motion processing and of physiological responses of neurons in the primate visual system.

Stone, L. S.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with a GaAs phase conjugate mirror

A method and apparatus is disclosed for detecting and tracking moving objects in a noise environment cluttered with fast-and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photo-refractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the inter-ferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

X-ray spectroscopic instrumentation for the 21st century

Several technologies being developed for high resolution X-ray spectroscopy are compared to determine the most suitable applications for each. Nondispersive cryogenic technology is considered by means of devices such as microcalorimeters and superconducting tunnel-junction detectors, and dispersive technologies are represented by crystal diffractors, transmission gratings and reflection gratings. Calorimeters and superconducting tunnel-junction conductors are found to be suitable for high energies while reflection gratings are more effective at lower energies. In general, however, the selected technology depends primarily on the particular implementation. Parameters such as launch capability, constraints, and scientific drivers are the guiding forces for selecting a particular device.

Kahn, Steven M.↗

Effect Of Contrast On Perceived Motion Of A Plaid

Report desribes series of experiments examining effect of contrast on perception of moving plaids. Each plaid pattern used in experiments was sum of two drifting sinusoidal gratings of different orientations. One of many studies helping to show how brain processes visual information on moving patterns. When gratings forming plaid differ in contrast, apparent direction of motion of plaid biased up to 20 degrees toward direction of grating of higher contrast.

Stone, L. S.↗

X-ray/EUV optics for astronomy, microscopy, polarimetry, and projection lithography; Proceedings of the Meeting, San Diego, CA, July 9-13, 1990

Topics discussed in this issue include the fabrication of multilayer X-ray/EUV coatings; the design, characterization, and test of multilayer X-ray/EUV coatings; multilayer X-ray/EUV monochromators and imaging microscopes; X-ray/EUV telescopes; the test and calibration performance of X-ray/EUV instruments; XUV/soft X-ray projection lithography; X-ray/EUV space observatories and missions; X-ray/EUV telescopes for solar research; X-ray/EUV polarimetry; X-ray/EUV spectrographs; and X-ray/EUV filters and gratings. Papers are presented on the deposition-controlled uniformity of multilayer mirrors, interfaces in Mo/Si multilayers, the design and analysis of an aspherical multilayer imaging X-ray microscope, recent developments in the production of thin X-ray reflecting foils, and the ultraprecise scanning technology. Consideration is also given to an active sun telescope array, the fabrication and performance at 1.33 nm of a 0.24-micron-period multilayer grating, a cylindrical proportional counter for X-ray polarimetry, and the design and analysis of the reflection grating arrays for the X-Ray Multi-Mirror Mission.

Hoover, Richard B.↗

The AXAF CCD imaging spectrometer

The current status of the instrument design and the status of the CCDs being fabricated for the AXAF CCD Imaging Spectrometer (ACIS) are summarized. The instrument consists of an image recording array of CCDs and a linear arrangement of CCDs to record the spectra formed by the objective grating spectrometer. Both arrays employ CCDs with pixel dimensions which correspond to about 0.5 arcsec samples of the image. The CCDs provide moderate spectral resolution and good detection efficiency over the energy range 0.5 to 10 keV. Spectral resolution of 200 or more is achievable using the objective grating with the grating array. Radiation damage effects are shown to degrade the energy resolution of CCDs. Specially designed CCD pixel architecture is employed together with shielding and low temperature operation to slow the effects of radiation damage.

Garmire, G. P.↗

Shallow-trap-induced positive absorptive two-beam coupling 'gain' and light-induced transparency in nominally undoped barium titanate

The asymmetry of beam coupling with respect to the orientation of the polar axis in a nominally undoped barium titanate crystal is used to determine the electro-optic and absorptive 'gain' in the usual beam-coupling geometry. For small grating wave vectors, the electrooptic coupling vanishes but the absorptive coupling remains finite and positive. Positive absorptive coupling at small grating wave vectors is correlated with the light-induced transparency of the crystal described herein. The intensity and grating wave vector dependence of the electrooptic and absorptive coupling, and the light-induced transparency are consistent with a model incorporating deep and shallow levels.

Garrett, M. H.↗

Optical Technologies for UV Remote Sensing Instruments

Over the last decade significant advances in technology have made possible development of instruments with substantially improved efficiency in the UV spectral region. In the area of optical coatings and materials, the importance of recent developments in chemical vapor deposited (CVD) silicon carbide (SiC) mirrors, SiC films, and multilayer coatings in the context of ultraviolet instrumentation design are discussed. For example, the development of chemically vapor deposited (CVD) silicon carbide (SiC) mirrors, with high ultraviolet (UV) reflectance and low scatter surfaces, provides the opportunity to extend higher spectral/spatial resolution capability into the 50-nm region. Optical coatings for normal incidence diffraction gratings are particularly important for the evolution of efficient extreme ultraviolet (EUV) spectrographs. SiC films are important for optimizing the spectrograph performance in the 90 nm spectral region. The performance evaluation of the flight optical components for the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) instrument, a spectroscopic instrument to fly aboard the Solar and Heliospheric Observatory (SOHO) mission, designed to study dynamic processes, temperatures, and densities in the plasma of the upper atmosphere of the Sun in the wavelength range from 50 nm to 160 nm, is discussed. The optical components were evaluated for imaging and scatter in the UV. The performance evaluation of SOHO/CDS (Coronal Diagnostic Spectrometer) flight gratings tested for spectral resolution and scatter in the DGEF is reviewed and preliminary results on resolution and scatter testing of Space Telescope Imaging Spectrograph (STIS) technology development diffraction gratings are presented.

Keski-Kuha, R. A. M.↗

Manufacturing the key to binary optics

The topics are presented in viewgraph form, and the topics covered include the following: gratings, grating characteristics, grating manufacture, zone plate, zone plate characteristics, zone plate manufacture, holography, holographic aberration correction, wavefront generated holograms, computer generated holograms, fabrication, fabrication capabilities, replication, processing errors, and quality control.

Guenther, Bob D.↗