Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Factorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

High thermoelectric power factor in two-dimensional crystals of Mo S 2

The quest for high-efficiency heat-to-electricity conversion has been one of the major driving forces toward renewable energy production for the future. Efficient thermoelectric devices require high voltage generation from a temperature gradient and a large electrical conductivity while maintaining a low thermal conductivity. For a given thermal conductivity and temperature, the thermoelectric power factor is determined by the electronic structure of the material. Low dimensionality (1D and 2D) opens new routes to a high power factor due to the unique density of states (DOS) of confined electrons and holes. The 2D transition metal dichalcogenide (TMDC) semiconductors represent a new class of thermoelectric materials not only due to such confinement effects but especially due to their large effective masses and valley degeneracies. Here, we report a power factor of MoS2 as large as 8.5 mW m –1 K –2 at room temperature, which is among the highest measured in traditional, gapped thermoelectric materials. To obtain these high power factors, we perform thermoelectric measurements on few-layer MoS 2 in the metallic regime, which allows us to access the 2D DOS near the conduction band edge and exploit the effect of 2D confinement on electron scattering rates, resulting in a large Seebeck coefficient. We conclude the demonstrated high, electronically modulated power factor in 2D TMDCs holds promise for efficient thermoelectric energy conversion.

36 MATERIALS SCIENCE↗

Structure factors of the unitary gas under supernova conditions

Here, we compute with lattice field theory the vector and axial static structure factors of the unitary gas for arbitrary temperature above the superfluid transition and for fugacities 0.1 < $\mathcal{z}$ < 1.0 . Using the lattice formulation, we calculate beyond the validity of the virial expansion, a commonly used technique in many-body physics. We find qualitative differences in the behavior of the structure factors at high fugacity compared to the predictions of the virial expansion. Due to the large scattering length of neutrons, we expect the unitary gas structure factors to approximate the structure factors of hot neutron gases, and we therefore expect our calculations to be useful in supernova simulations, where neutron gas structure factors are needed to compute in-medium neutrino-neutron scattering rates.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining spectroscopic factors near the r -process path using combined measurements: Kr 86 ( d , p ) 87 Kr

Background: Current nuclear structure models indicate that the shell structure near the valley of stability, with well-established shell closures at N=50, for example, changes in very neutron-rich nuclei far from stability. Single-particle properties of nuclei away from stability can be probed in single-neutron (d,p) transfer reactions with beams of rare isotopes. The interpretation of these data requires reaction theories with various effective interactions. Often, approximations made to the final bound-state potential introduce a large uncertainty in the extracted single-particle properties, in particular the spectroscopic factor. Purpose: Mitigate this uncertainty using a combined measurement method to constrain the shape of the bound-state potential and to reliably extract the spectroscopic factor. Methods: The 2 H( 86 Kr,p) 87 Kr reaction was measured at 33 MeV/u at the National Superconducting Cyclotron Laboratory (NSCL) as a test of the combined method. The reaction protons were detected with the Oak Ridge Rutgers University Barrel Array (ORRUBA) of position sensitive silicon strip detectors, the first implementation of ORRUBA coupled to the S800 spectrograph with fast beams at NSCL. Results: These measurements at 33 MeV/u are combined with previous studies of the 86 Kr(d,p) reaction at 5.5 MeV/u to demonstrate a successful case of the combined method to constrain the shape of the single-particle potential and deduce asymptotic normalization coefficients and spectroscopic factors. In particular, the single-particle asymptotic normalization coefficient for the ground state of 87 Kr was constrained to b d5/2 =6.46$^{+1.12}_{–0.57}$ fm –1/2 , and therefore the deduced spectroscopic factor is S=0.44$^{+0.09}_{–0.13}$ with uncertainties dominated by experimental statistics. Conclusions: By combining measurements at two very different beam energies, single-particle asymptotic normalization coefficients, at least for low angular momentum transfers, can be constrained. Thus, spectroscopic factors can be deduced with uncertainties dominated by experimental uncertainties, rather than limited knowledge of bound-state potential parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unified description of DGLAP, CSS, and BFKL evolution: TMD factorization bridging large and small x

This paper introduces a transverse-momentum dependent (TMD) factorization scheme designed to unify both large and small Bjorken-x regimes. We compute the next-to-leading order quantum chromodynamics (QCD) corrections to the gluon TMD operator for an unpolarized hadron within this proposed scheme. This leads to the emergence of a new TMD evolution, incorporating those in transverse momentum, rapidity, and Bjorken-x. When matched to the collinear factorization scheme, our factorization scheme faithfully reproduces the well-established Dokshitzer-Gribov-Lipatov-Altarelli-Parisi and Collins-Soper-Sterman (CSS) evolutions. Conversely, matching with high-energy factorization not only yields the Balitsky-Fadin-Kuraev-Lipatov evolution but also reveals distinctive signatures of CSS logarithms. The development of this novel TMD factorization scheme, capable of seamlessly reconciling disparate Bjorken-x regimes and faithfully reproducing established QCD evolution equations, has the potential to significantly advance our comprehension of high-energy processes and three-dimensional parton structures of hadrons. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-loop matching factors for light quark masses and three-loop mass anomalous dimensions in the regularization invariant symmetric momentum-subtraction schemes

Light quark masses can be determined through lattice simulations in regularization invariant momentum-subtraction (RI/MOM) schemes. Subsequently, matching factors, computed in continuum perturbation theory, are used in order to convert these quark masses from a RI/MOM scheme to the MS scheme. We calculate the two-loop corrections in QCD to these matching factors as well as the three-loop mass anomalous dimensions for the RI/SMOM and RI/SMOM{sub {gamma}{sub {mu}} }schemes. These two schemes are characterized by a symmetric subtraction point. Providing the conversion factors in the two different schemes allows for a better understanding of the systematic uncertainties. The two-loop expansion coefficients of the matching factors for both schemes turn out to be small compared to the traditional RI/MOM schemes. For n{sub f}=3 quark flavors they are about 0.6%-0.7% and 2%, respectively, of the leading order result at scales of about 2 GeV. Therefore, they will allow for a significant reduction of the systematic uncertainty of light quark mass determinations obtained through this approach. The determination of these matching factors requires the computation of amputated Green's functions with the insertions of quark bilinear operators. As a by-product of our calculation we also provide the corresponding results for the tensor operator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

$B \to \pi \ell \nu$ and $B_s \to K \ell \nu$ form factors and $|V_{ub}|$ from 2+1-flavor lattice QCD with domain-wall light quarks and relativistic heavy quarks

We calculate the form factors for B → πℓν and B s → Kℓν decay in dynamical lattice quantum chromodynamics (QCD) using domain-wall light quarks and relativistic b-quarks. We use the (2+1)-flavor gauge-field ensembles generated by the RBC and UKQCD collaborations with the domain-wall fermion action and Iwasaki gauge action. For the b-quarks we use the anisotropic clover action with a relativistic heavy-quark interpretation. We analyze data at two lattice spacings of a ≈ 0.11, 0.086 fm with unitary pion masses as light as M π ≈ 290 MeV. We simultaneously extrapolate our numerical results to the physical light-quark masses and to the continuum and interpolate in the pion/kaon energy using SU(2) “hard-pion” chiral perturbation theory for heavy-light meson form factors. We provide complete systematic error budgets for the vector and scalar form factors f + (q 2 ) and f 0 (q 2 ) for both B → πℓν and B s → Kℓν at three momenta that span the q 2 range accessible in our numerical simulations. Next we extrapolate these results to q 2 = 0 using a model-independent z-parametrization based on analyticity and unitarity. We present our final results for f + (q 2 ) and f 0 (q 2 )as the coefficients of the series in z and the matrix of correlations between them; this provides a parametrization of the form factors valid over the entire allowed kinematic range. Our results agree with other three-flavor lattice-QCD determinations using staggered light quarks, and have comparable precision, thereby providing important independent cross-checks. Both B → πℓν and B s → Kℓν decays enable determinations of the Cabibbo-Kobayashi-Maskawa matrix element |V ub |. Furthermore, we perform a combined z-fit of our numerical B → πℓν form-factor data with the experimental measurements of the branching fraction from BABAR and Belle leaving the relative normalization as a free parameter; we obtain |V ub | = 3.61(32)×10 -3 , where the error includes statistical and all systematic uncertainties. The same approach can be applied to the decay B s → Kℓν to provide an alternative determination of |V ub | once the process has been measured experimentally. In anticipation of future experimental measurements, we make predictions for B → πℓν and B s → Kℓν differential branching fractions and forward-backward asymmetries in the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Λ b → p ℓ - ν ¯ ℓ and Λ b → Λ c ℓ - ν ¯ ℓ form factors from lattice QCD with relativistic heavy quarks

Measurements of the Λ b → p ℓ - ν ¯ ℓ and Λ b → Λ c ℓ - ν ¯ ℓ decay rates can be used to specify the magnitudes of the Cabibbo-Kobayashi-Maskawa matrix elements Vub and Vcb, provided that the relevant hadronic form factors are known. In this work we present a precise calculation of these form factors using lattice QCD with 2 + 1 flavors of dynamical domain-wall fermions. The b and c quarks are implemented with relativistic heavy-quark actions, allowing us to work directly at the physical heavy-quark masses. The lattice computation is performed for six different pion masses and two different lattice spacings, using gauge-field configurations generated by the RBC and UKQCD Collaborations. The b → u and b → c currents are renormalized with a mostly nonperturbative method. We extrapolate the form factor results to the physical pion mass and the continuum limit, parametrizing the q 2 dependence using z expansions. The form factors are presented in such a way as to enable the correlated propagation of both statistical and systematic uncertainties into derived quantities such as differential decay rates and asymmetries. Using these form factors, we present predictions for the Λ b → p ℓ - ν ¯ ℓ and Λ b → Λ c ℓ - ν ¯ ℓ differential and integrated decay rates. Combined with experimental data, our results enable determinations of |V ub |, |V cb |, and |V ub /V cb | with theory uncertainties of 4.4%, 2.2%, and 4.9%, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Collinear factorization violation and effective field theory

The factorization of amplitudes into hard, soft and collinear parts is known to be violated in situations where incoming particles are collinear to outgoing ones. This conclusion was first derived by studying limits where noncollinear particles become collinear. We demonstrate that through an effective field theory framework with Glauber operators, these factorization-violating effects can be reproduced from an amplitude that is factorized before the splitting occurs.We confirm results at one loop, through single Glauber exchange, and at two loops, through double Glauber exchange. To approach the calculation, we begin by reviewing the importance of Glauber scaling for factorization.We show that for any situation where initial-state and finalstate particles are not collinear, the Glauber contribution is entirely contained in the soft contribution. The contributions coming from Glauber operators are necessarily nonanalytic functions of external momentum, with the nonanalyticity arising from the rapidity regulator. The nonanalyticity is crucial so that Glauber operators can both preserve factorization when it holds and produce factorization-violating effects when they are present.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Measurement of the Neutron Magnetic Form Factor from A=3 Mirror Nuclei

The electromagnetic form factors of the proton and neutron encode information on the spatial structure of their charge and magnetization distributions. While measurements of the proton are relatively straightforward, the lack of a free neutron target makes measurements of the neutron's electromagnetic structure more challenging and more sensitive to experimental or model-dependent uncertainties. Various experiments have attempted to extract the neutron form factors from scattering from the neutron in deuterium, with different techniques providing different, and sometimes large, systematic uncertainties. We present results from a novel measurement of the neutron magnetic form factor using quasielastic scattering from the mirror nuclei 3 H and 3 He, where the nuclear effects are larger than for deuterium but expected to largely cancel in the cross-section ratios. We extracted values of the neutron magnetic form factor for low-to-modest momentum transfer, 0.6 < Q 2 < 2.9 GeV 2 , where existing measurements give inconsistent results. The precision and Q 2 range of these data allow for a better understanding of the current world’s data and suggest a path toward further improvement of our overall understanding of the neutron’s magnetic form factor.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mapping Dense LU Factorization on Multicore Supercomputer Nodes

Dense LU factorization is a prominent benchmark used to rank the performance of supercomputers. Many implementations use block-cyclic distributions of matrix blocks onto a two-dimensional process grid. The process grid dimensions drive a trade-off between communication and computation and are architecture- and implementation-sensitive. The critical panel factorization steps can be made less communication-bound by overlapping asynchronous collectives for pivoting with the computation of rank-k updates. By shifting the computation-communication trade-off, a modified block-cyclic distribution can beneficially exploit more available parallelism on the critical path, and reduce panel factorization's memory hierarchy contention on now-ubiquitous multicore architectures. During active panel factorization, rank-1 updates stream through memory with minimal reuse. In a column-major process grid, the performance of this access pattern degrades as too many streaming processors contend for access to memory. A block-cyclic mapping in the row-major order does not encounter this problem, but consequently sacrifices node and network locality in the critical pivoting steps. We introduce 'striding' to vary between the two extremes of row- and column-major process grids. The maximum available parallelism in the critical path work (active panel factorization, triangular solves, and subsequent broadcasts) is bounded by the length or width of the process grid. Increasing one dimension of the process grid decreases the number of distinct processes and nodes in the other dimension. To increase the harnessed parallelism in both dimensions, we start with a tall process grid. We then apply periodic 'rotation' to this grid to restore exploited parallelism along the row to previous levels. As a test-bed for further mapping experiments, we describe a dense LU implementation that allows a block distribution to be defined as a general function of block to processor. Other mappings can be tested wit...

Computer Science↗

GPU Accelerated Sparse Cholesky Factorization

The solution of sparse symmetric positive definite linear systems is an important computational kernel in large-scale scientific and engineering modeling and simulation. We will solve the linear systems using a direct method, in which a Cholesky factorization of the coefficient matrix is performed using a right-looking approach and the resulting triangular factors are used to compute the solution. Sparse Cholesky factorization is compute intensive. In this work we investigate techniques for reducing the factorization time in sparse Cholesky factorization by offloading some of the dense matrix operations on a GPU. We will describe the techniques we have considered. We achieved up to 4x speedup compared to the CPU-only version.

Karsavuran, M Ozan↗

Factors and Considerations for Modeling Loss of a GaN-based Inverter

The article investigates the impacts of four often-neglected factors on the loss model of a GaN-based full-bridge inverter: parasitic capacitance of the devices, dynamics of junction temperature (Tj) under time-varying power dissipation (Ploss), case temperature estimation, and detailed considerations of the passive components. Procedures to calculate the converter loss considering the above factors are proposed and implemented. A 4.5-kW hard-switching inverter prototype using gallium nitrite (GaN) high-electron-mobility transistors is used to experimentally demonstrate the impact of each factor on the converter loss model. Furthermore, it is found that the accuracy of a converter loss model is mainly affected by the passive components at the light load condition, whereas the thermal and loss models of the active components become the major factors as the output power increases. The results show that after considering the above factors, the converter loss discrepancy between calculation and measurement can be reduced from 30.6 W (28%) to 2.5 W (less than 3%) at heavy load (Po = 4.5 kW), while at the light load condition (Po = 500 W), it is reduced from 3.9 W (28%) to 2.6 W (16%). Furthermore, the difference between simulated and measured case temperature of the GaN devices is within 6 °C.

42 ENGINEERING↗

Environmental factors function as constraints on soil nitrous oxide fluxes in bioenergy feedstock cropping systems

Abstract Nitrous oxide (N 2 O) is a potent greenhouse gas and major component of the net global warming potential of bioenergy feedstock cropping systems. Numerous environmental factors influence soil N 2 O production, making direct correlation difficult to any one factor of N 2 O fluxes under field conditions. We instead employed quantile regression to evaluate whether soil temperature, water‐filled pore space ( WFPS ), and concentrations of soil nitrate ( ) and ammonium ( ) determined upper bounds for soil N 2 O flux magnitudes. We collected data over 6 years from a range of bioenergy feedstock cropping systems including no‐till grain crops, perennial warm‐season grasses, hybrid poplar, and polycultures of tallgrass prairie species each with and without nitrogen (N) addition grown at two sites. The upper bounds for soil N 2 O fluxes had a significant and positive correlation with all four environmental factors, although relatively large fluxes were still possible at minimal values for nearly all factors. The correlation with was generally weaker, suggesting it is less important than in driving large fluxes. Quantile regression slopes were generally lower for unfertilized perennials than for other systems, but this may have resulted from a perpetual state of nitrogen limitation, which prevented other factors from being clear constraints. This framework suggests efforts to reduce concentrations of in the soil may be effective at reducing high‐intensity periods—”hot moments”—of N 2 O production.

59 BASIC BIOLOGICAL SCIENCES↗

The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e

A graphite flat cavity ionization chamber is used at the BIPM in France to determine the absorbed dose to graphite in a {sup 60}Co photon beam and thereby used to determine the product of the value of W/e, the average energy required to produce an ion pair in dry air, and the value of (L{sub {Delta}}/{rho}){sub a}{sup C}, the mean restricted mass collision stopping-power ratio for graphite to air in a {sup 60}Co beam. The accuracy of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value thus determined depends upon the accuracy of the perturbation correction factors adopted for this chamber. The perturbation effect of this chamber was accounted for by the replacement correction factor whose value was calculated by an analytical method and confirmed by an EGS4 Monte Carlo calculation. The purpose of this study is to investigate the validity of the analytical and the EGS4 calculations by using recently established methods and the EGSnrc Monte Carlo code, a much improved version of EGS4, to calculate the replacement correction factors for the graphite chamber. It is found that the replacement correction factors used for the BIPM chamber are not correct: the values used are smaller than they should be by about 1%. This leads to a 1% overestimation of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value determined by using this chamber. This implies that {sup 60}Co air kerma standards that are directly proportional to this product need to be reduced by 1%. Based on the values of the replacement correction factors calculated in this study, and on the value of (L{sub {Delta}}/{rho}){sub a}{sup C} evaluated from ICRU Report No. 37 stopping power for graphite, the value of W/e determined by using the BIPM chamber should be 33.61{+-}0.08 J/C. If a more recent value of mean excitation energy for graphite (86.8 eV) and grain density are used to evaluate the graphite stopping power, then the value obtained for W/e is 34.15{+-}0.08 J/C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma Knife output factor measurements using VIP polymer gel dosimetry

Purpose: Water equivalent polymer gel dosimeters and magnetic resonance imaging were employed to measure the output factors of the two smallest treatment fields available in a Gamma Knife model C radiosurgery unit, those formed employing the 4 and 8 mm final collimator helmets. Methods: Three samples of the VIP normoxic gel formulation were prepared and irradiated so that a single shot of the field whose output factor is to be measured and a single shot of the reference 18 mm field were delivered in each one. Emphasis is given to the development and benchmarking of a refined data processing methodology of reduced uncertainty that fully exploits the 3D dose distributions registered in the dosimeters. Results: Polymer gel results for the output factor of the 8 mm collimator helmet are found to be in close agreement with the corresponding value recommended by the vendor (0.955{+-}0.007 versus 0.956, respectively). For the 4 mm collimator helmet, however, polymer gel results suggest an output factor 3% lower than the value recommended by the vendor (0.841{+-}0.009 versus 0.870, respectively). Conclusions: A comparison with corresponding measurements published in the literature indicates that output factor results of this work are in agreement with those obtained using dosimetric systems which, besides fine spatial resolution and lack of angular and dose rate dependence of the dosimeter's response, share with polymer gels the favorable characteristic of minimal radiation field perturbation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of ionization chamber absorbed dose k{sub Q} factors in megavoltage photon beams

Purpose: Absorbed dose beam quality conversion factors (k{sub Q} factors) were obtained for 27 different types of ionization chamber. The aim was to obtain objective evidence on the performance of a wide range of chambers currently available, and potentially used for reference dosimetry, and to investigate the accuracy of the k{sub Q} calculation algorithm used in the TG-51 protocol. Methods: Measurements were made using the {sup 60}Co irradiator and Elekta Precise linac facilities at the National Research Council of Canada. The objective was to characterize the chambers over the range of energies applicable to TG-51 and determine whether each chamber met the requirements of a reference-class instrument. Chamber settling, leakage current, ion recombination and polarity, and waterproofing sleeve effects were investigated, and absorbed dose calibration coefficients were obtained for {sup 60}Co and 6, 10, and 25 MV photon beams. Only thimble-type chambers were considered in this investigation and were classified into three groups: (i) Reference chambers (''standard''0.6 cm{sup 3} Farmer-type chambers and their derivatives traditionally used for beam output calibration); (ii) scanning chambers (typically 0.1 cm{sup 3} volume chambers used for beam commissioning with 3-D scanning phantoms); and (iii) microchambers (very small volume ion chambers ({<=}0.01 cm{sup 3}) used for small field dosimetry). Results: As might be expected, 0.6 cm{sup 3} thimble chambers showed the most predictable performance and experimental k{sub Q} factors were obtained with a relative uncertainty of 0.1%. The performance of scanning and microchambers was somewhat variable. Some chambers showed very good behavior but others showed anomalous polarity and recombination corrections that are not fully explained at present. For the well-behaved chambers, agreement between measured and calculated k{sub Q} factors was within 0.4%; for some chambers, differences of more than 1% were seen that may be related to the recombination/polarity results. Use of such chambers could result in significant errors in the determination of reference dose in the clinic. Conclusions: Based on the experimental evidence obtained here, specification for a reference-class ionization chamber could be developed that would minimize the error in using a dosimetry protocol with calculated beam quality conversion factors. The experimental k{sub Q} data obtained here for a wide range of thimble chambers can be used when choosing suitable detectors for reference dosimetry and are intended to be used in the upcoming update/addendum to the AAPM TG-51 dosimetry protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of depth-dependent perturbation factors for silicon diodes using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the perturbation factor in megavoltage electron beams for three models of silicon diodes (IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded) using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6-, 12-, and 18-MeV clinical electron beams. They also measured depth-dose curves using the IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded diodes. The authors used the depth-dose curves measured with the PSD as a perturbation-free reference to extract the perturbation factors of the diodes. Results: The authors found that the perturbation factors for the diodes increased substantially with depth, especially for low-energy electron beams. The experimental results show the same trend as published Monte Carlo simulation results for the EFD diode; however, the perturbations measured experimentally were greater. They found that using an effective point of measurement (EPOM) placed slightly away from the source reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: The manufacturer recommended EPOM appears to be incorrect at low electron energy (6 MeV). In addition, the perturbation factors for diodes may be greater than predicted by Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scatter factors assessment in microbeam radiation therapy

Purpose: The success of the preclinical studies in Microbeam Radiation Therapy (MRT) paved the way to the clinical trials under preparation at the Biomedical Beamline of the European Synchrotron Radiation Facility. Within this framework, an accurate determination of the deposited dose is crucial. With that aim, the scatter factors, which translate the absolute dose measured in reference conditions (2 x 2 cm{sup 2} field size at 2 cm-depth in water) to peak doses, were assessed. Methods: Monte Carlo (MC) simulations were performed with two different widely used codes, PENELOPE and GEANT4, for the sake of safety. The scatter factors were obtained as the ratio of the doses that are deposited by a microbeam and by a field of reference size, at the reference depth. The calculated values were compared with the experimental data obtained by radiochromic (ISP HD-810) films and a PTW 34070 large area chamber. Results: The scatter factors for different microbeam field sizes assessed by the two MC codes were in agreement and reproduced the experimental data within uncertainty bars. Those correction factors were shown to be non-negligible for the future MRT clinical settings: an average 30% lower dose was deposited by a 50 {mu}m microbeam with respect to the reference conditions. Conclusions: For the first time, the scatter factors in MRT were systematically studied. They constitute an essential key to deposit accurate doses in the forthcoming clinical trials in MRT. The good agreement between the different calculations and the experimental data confirms the reliability of this challenging micrometric dose estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗