Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Frequency Response Analysis Tool

Frequency response has received a lot of attention in recent years at the national level, which culminated in the development and approval of North American Electricity Reliability Corporation (NERC) BAL-003-1 Frequency Response and Frequency Bias Setting Reliability Standard. This report is prepared to describe the details of the work conducted by Pacific Northwest National Laboratory (PNNL) in collaboration with the Bonneville Power Administration and Western Electricity Coordinating Council (WECC) Joint Synchronized Information Subcommittee (JSIS) to develop a frequency response analysis tool (FRAT). The document provides the details on the methodology and main features of the FRAT. The tool manages the database of under-frequency events and calculates the frequency response baseline. Frequency response calculations are consistent with frequency response measure (FRM) in NERC BAL-003-1 for an interconnection and balancing authority. The FRAT can use both phasor measurement unit (PMU) data, where available, and supervisory control and data acquisition (SCADA) data. The tool is also capable of automatically generating NERC Frequency Response Survey (FRS) forms required by BAL-003-1 Standard.

97 MATHEMATICS AND COMPUTING↗

Using Synchrophasors for Frequency Response Analysis in the Western Interconnection

Frequency response has received a lot of attention in recent years at the national level, which culminated in the development and approval of NERC BAL-003-1 Frequency Response and Frequency Bias Setting Reliability Standard. WECC JSIS, NASPI, BPA, CERTS and PNNL collaborate on the common goals to deliver to the industry applications for frequency response analysis at interconnection, Balancing Authority and individual power plant levels. This paper describes a Frequency Response Analysis Tool that has been used for establishing a frequency response baseline for the Western Interconnection. This paper describes how synchrophasor data is used in for determination of generator characteristics – frequency responsive, under load control or baseloaded. This paper also discusses and provides an example of how the frequency response distribution can impact power pick-up on major transmission paths.

Kosterev, Dmitry↗

Investigation of the Statistics of Pure Tone Sound Power Injection from Low Frequency, Finite Sized Sources in a Reverberant Room

The effect of finite source size on the power statistics in a reverberant room for pure tone excitation was investigated. Theoretical results indicate that the standard deviation of low frequency, pure tone finite sources is always less than that predicted by point source theory and considerably less when the source dimension approaches one-half an acoustic wavelength or greater. A supporting experimental study was conducted utilizing an eight inch loudspeaker and a 30 inch loudspeaker at eleven source positions. The resulting standard deviation of sound power output of the smaller speaker is in excellent agreement with both the derived finite source theory and existing point source theory, if the theoretical data is adjusted to account for experimental incomplete spatial averaging. However, the standard deviation of sound power output of the larger speaker is measurably lower than point source theory indicates, but is in good agreement with the finite source theory.

Smith, Wayne Farrior↗

Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry

Traceability to the International System of Units has been established for vibration and shock measurements as specified in international document standards, recommendations, and regulations to ensure product quality, health, and safety. New and upgraded laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods in the ISO 16063 series of international document standards. In ISO 16063-11:1999, three interferometric methods are specified for the primary calibration of vibration transducers (reference standard accelerometers) in a frequency range from 1 Hz to 10 kHz. In order to specify the same (modified) methods for the calibration of laser vibrometers (ISO 16063-41:2011), their applicability in an expanded frequency range was investigated. Steady-state sinusoidal vibrations were generated by piezoelectric actuators at specific frequencies up to 347 kHz (acceleration amplitudes up to 376 km/s{sup 2}). The displacement amplitude, adjusted by the special interferometric method of coincidence to 158.2 nm (quarter the wavelength of the He-Ne laser light), was measured by the standardized interferometric methods of fringe counting and sine-approximation. The deviations between the measurement results of the three interferometric methods applied simultaneously were smaller than 1 %. The limits of measurement uncertainty specified in ISO 16063-11 between 1 Hz to 10 kHz were kept up to frequencies, which are orders of magnitude greater; the uncertainty limit 0.5 % specified at the reference frequency 160 Hz was not exceeded at 160 kHz. The reported results were considered during the development of ISO 16063-41 by specifying the instrumentation and procedures for performing calibrations of rectilinear laser vibrometers in the frequency range typically between 0.4 Hz and 50 kHz—the interferometric methods may be applied within expanded frequency ranges using refined techniques and procedures. It is concluded that calibration frequencies up to 0.5 MHz are attainable in compliance with the first international document standard for the calibration of laser vibrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A space system for high-accuracy global time and frequency comparison of clocks

A Space Shuttle experiment in which a hydrogen maser clock on board the Space Shuttle will be compared with clocks on the ground using two-way microwave and short pulse laser signals is described. The accuracy goal for the experiment is 1 nsec or better for the time transfer and 10 to the minus 14th power for the frequency comparison. A direct frequency comparison of primary standards at the 10 to the minus 14th power accuracy level is a unique feature of the proposed system. Both time and frequency transfer will be accomplished by microwave transmission, while the laser signals provide calibration of the system as well as subnanosecond time transfer.

Decher, R.↗

Comparison of low-altitude wind-shear statistics derived from measured and proposed standard wind profiles

Wind shear statistics were calculated for a simulated set of wind profiles based on a proposed standard wind field data base. Wind shears were grouped in altitude in altitude bands of 100 ft between 100 and 1400 ft and in wind shear increments of 0.025 knot/ft. Frequency distributions, means, and standard deviations for each altitude band were derived for the total sample were derived for both sets. It was found that frequency distributions in each altitude band for the simulated data set were more dispersed below 800 ft and less dispersed above 900 ft than those for the measured data set. Total sample frequency of occurrence for the two data sets was about equal for wind shear values between +0.075 knot/ft, but the simulated data set had significantly larger values for all wind shears outside these boundaries. It is shown that normal distribution in both data sets neither data set was normally distributed; similar results are observed from the cumulative frequency distributions.

Usry, J. W.↗

The design of a turboshaft speed governor using modern control techniques

The objectives of this program were: to verify the model of off schedule compressor variable geometry in the T700 turboshaft engine nonlinear model; to evaluate the use of the pseudo-random binary noise (PRBN) technique for obtaining engine frequency response data; and to design a high performance power turbine speed governor using modern control methods. Reduction of T700 engine test data generated at NASA-Lewis indicated that the off schedule variable geometry effects were accurate as modeled. Analysis also showed that the PRBN technique combined with the maximum likelihood model identification method produced a Bode frequency response that was as accurate as the response obtained from standard sinewave testing methods. The frequency response verified the accuracy of linear models consisting of engine partial derivatives and used for design. A power turbine governor was designed using the Linear Quadratic Regulator (LQR) method of full state feedback control. A Kalman filter observer was used to estimate helicopter main rotor blade velocity. Compared to the baseline T700 power turbine speed governor, the LQR governor reduced droop up to 25 percent for a 490 shaft horsepower transient in 0.1 sec simulating a wind gust, and up to 85 percent for a 700 shaft horsepower transient in 0.5 sec simulating a large collective pitch angle transient.

Delosreyes, G.↗

James Webb Space Telescope - L2 Communications for Science Data Processing

JWST is the first NASA mission at the second Lagrange point (L2) to identify the need for data rates higher than 10 megabits per second (Mbps). JWST will produce approximately 235 Gigabits of science data every day that will be downlinked to the Deep Space Network (DSN). To get the data rates desired required moving away from X-band frequencies to Ka-band frequencies. To accomplish this transition, the DSN is upgrading its infrastructure. This new range of frequencies are becoming the new standard for high data rate science missions at L2. With the new frequency range, the issues of alternatives antenna deployment, off nominal scenarios, NASA implementation of the Ka-band 26 GHz, and navigation requirements will be discussed in this paper. JWST is also using Consultative Committee for Space Data Systems (CCSDS) standard process for reliable file transfer using CCSDS File Delivery Protocol (CFDP). For JWST the use of the CFDP protocol provides level zero processing at the DSN site. This paper will address NASA implementations of Ground Stations in support of Ka-band 26 GHz and lesson learned from implementing a file base (CFDP) protocol operational system.

Johns, Alan↗

Atmospheric profiling of water vapour with a 20.5-23.5 GHz autocorrelation radiometer

A tropospheric water vapor profiling system is presented. The hardware consists of an upward looking radiometer (CORRAD) deployed at ground level. The CORRAD measures the autocorrelation of the downwelling thermal emission from the atmosphere over a passband of 20.5 to 23.5 GHz out to a maximum time delay of 6.1 ns. This produces 100 MHz resolution imaging of the complete emission spectrum about the 22.235 GHz water vapor resonance line. The 31 equivalent frequency channels produced by Fourier transformation of the data provide additional constraints on the inversion process required to estimate the water vapor profile, as compared to standard 2 to 5 frequency channel profiling systems. The CORRAD hardware is described, and radiometer and radiosonde profiles are compared.

Ruff, C. S.↗

Laser with an in-loop relative frequency stability of 1.0x10{sup -21} on a 100-ms time scale for gravitational-wave detection

We report on the stabilization of the laser frequency for the Virgo gravitational-wave detector. We have obtained a frequency noise level, measured in loop, of 1.9x10{sup -7} Hz/{radical}(Hz) at 10 Hz for the 1064 nm laser; this value is limited by shot noise. The Allan standard deviation for relative frequency noise is 1.0x10{sup -21} on a 100-ms time scale. The spectral density of the laser frequency noise is negligible in the channel where gravitational waves ought to appear and meets the specifications for the target spectral resolution of the Virgo interferometer in the 10 Hz-10 kHz detection bandwidth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low altitude wind shear statistics derived from measured and FAA proposed standard wind profiles

Wind shear statistics were calculated for a simulated data set using wind profiles proposed as a standard and compared to statistics derived from measured wind profile data. Wind shear values were grouped in altitude bands of 100 ft between 100 and 1400 ft, and in wind shear increments of 0.025 kt/ft between + or - 0.600 kt/ft for the simulated data set and between + or - 0.200 kt/ft for the measured set. No values existed outside the + or - 0.200 kt/ft boundaries for the measured data. Frequency distributions, means, and standard deviations were derived for each altitude band for both data sets, and compared. Also, frequency distributions were derived for the total sample for both data sets and compared. Frequency of occurrence of a given wind shear was about the same for both data sets for wind shears, but less than + or 0.10 kt/ft, but the simulated data set had larger values outside these boundaries. Neglecting the vertical wind component did not significantly affect the statistics for these data sets. The frequency of occurrence of wind shears for the flight measured data was essentially the same for each altitude band and the total sample, but the simulated data distributions were different for each altitude band. The larger wind shears for the flight measured data were found to have short durations.

Dunham, R. E., Jr.↗

Active laser ranging with frequency transfer using frequency comb

A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used as time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tile-and-trim micro-resonator array fabrication optimized for high multiplexing factors

We present a superconducting micro-resonator array fabrication method that is scalable and reconfigurable and has been optimized for high multiplexing factors. The method uses uniformly sized tiles patterned on stepper photolithography reticles as the building blocks of an array. We exhibit this technique on a 101-element microwave kinetic inductance detector (MKID) array made from a titanium-nitride superconducting film. Characterization reveals 1.5% maximum fractional frequency spacing deviations caused primarily by material parameters that vary smoothly across the wafer. Yet, local deviations demonstrate a Gaussian distribution in fractional frequency spacing with a standard deviation of 2.7 × 10 -3 . We exploit this finding to increase the yield of the BLAST-TNG 250 μm production wafer by placing resonators in the array close in both physical and frequency space. This array consists of 1836 polarization-sensitive MKIDs wired in three multiplexing groups. We present the array design and show that the achieved yield is consistent with our model of frequency collisions and is comparable to what has been achieved in other low temperature detector technologies.

36 MATERIALS SCIENCE↗

Suppression of Parasitic Voltage Oscillation in Power Modules by Turn-Off Current Zero Placement

This paper presents a frequency-domain analysis of the turn-off equivalent switching network of a hard-switched semiconductor switching cell. This paper also proposes a novel method to suppress parasitic voltage ringing by placing the turn-off current zero at the parasitic resonant frequency. The turn-off current was decomposed into ramp functions and a constant-valued function to facilitate obtaining the frequency components of the turn-off current using the Laplace transform of standard signals. The proposed frequency-domain modeling of the parasitic voltage ringing and the suppression were validated by detailed circuit simulation using parameters corresponding to prior literature with experimental validation.

Galigekere, Veda Prakash↗

Polarimetric microwave scattering from known randomly rough surfaces

Scattering from rough surfaces is reviewed, and artificial randomly rough surfaces are described. Measurements were made from 4 to 18 GHz for the 4 linear polarization states. The target consists of a metalized randomly rough surface constructed from known surface statistical information. The surface was generated using surface generation routines on the computer, and then the data was converted for the machining of the surface on a computer controlled mill. Bistatic and monostatic measurements were acquired at incident angles from 25 to 60 deg. At the 13.5 to 18 GHz frequencies, the effects of backscatter enhancement and depolarization effects can be studied in a regime which does not satisfy Kirchoff or small perturbation assumptions. This allows scattering mechanisms to be introduced into models, which may show missing elements in the more standard formulations. At lower frequency bands such as 4 to 8.5 GHz the scattering behavior was also examined to see the behavior as assumptions of other formulations are satisfied.

Nance, C. E.↗

Fermilab PIP-II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges—especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies—advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance and were successfully implemented on a low-cost FPGA.

Wu, Jinyuan [Fermilab]↗

Alternate Methods of Model Reduction to Avoid Dynamic Modal Truncation Error

Loads analysis is traditionally performed using dynamically reduced models, which provides the benefit to reduce run time. If the reduced model frequency cutoff is not chosen appropriately, the model will lack the dynamic content required to fully represent the response of the non-reduced model. Standard guidance for reduced model frequency content, provided in NASA-STD-5002, is to solve fixed base modes up to a minimum of 1.5x the model frequency content of interest and to employ static modal truncation methods such as residual vectors, the mode acceleration method, and the residual flexibility method to account for the truncated flexibility of the missing modes. Fixed base modes require the selection of a set of degrees of freedom to be constrained which, if not properly selected, may affect the accuracy of the reduced model by excluding some of the dynamic characteristic of the full model. In this case, the standard NASA guidance would be insufficient, but it may not be readily apparent that a portion of the reduced model response is missing. This error was encountered during an independent verification and validation (IV&V) effort, where it was observed that the resulting dynamic response was lower than the inline analysis. In this specific case, despite following the standard NASA model reduction guidelines in the selection of the frequency cutoff, the inline model still did not fully capture the necessary dynamic content. As part of the IV&V, an alternate reduction methodology was employed using an unconstrained mode acceleration method. The original model initially performed a constrained reduction to twice the frequency content of interest before doing a free-free run, employing the mode acceleration method to account for the truncated modes. In contrast in the IV&V, the unconstrained model reduced directly to the needed frequency content of the free-free run, avoiding any interactions between constraints and dynamic content. To verify the model, the original reduction methodology was used to generate a series of Hurty-Craig-Bampton reductions, each with a higher frequency cutoff than the previous. The results were shown to converge once the frequency cutoff increased past eight times the frequency content of interest. At the same frequency cutoff, the results of the Hurty-Craig-Bampton model converged with the results of the unconstrained mode acceleration model. This comparative study provided confidence that the results of the unconstrained modal acceleration reduced model were correct and that the Hurty-Craig-Bampton needed to increase its frequency cutoff to fully capture the dynamic response.

Erin Simmons↗