Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration and Optimization of a Waste Heat Driven Organic Rankine Cycle for Power Generation in Wastewater Treatment Plants

The study focuses on achieving energy self-sufficiency in Wastewater Treatment Plants by proposing a comprehensive model for integrating, sizing, and optimizing an Organic Rankine Cycle system. The Organic Rankine Cycle system is designed to utilize waste heat from the gensets at As Samra Wastewater Treatment Plant in Jordan, where it will contribute to the overall electrical energy supply of the plant. Real data from As Samra Wastewater Treatment Plant is used to model and calculate the available waste heat using TRNSYS® software. The Organic Rankine Cycle model is then developed using ASPEN PLUS® software to explore the impact of operational parameters and determine their optimal values for maximizing the plant's energy profile. An economic analysis is conducted to assess the feasibility of the proposed model, considering system components, installation, operation, and maintenance costs. To optimize the Organic Rankine Cycle system, the study employs the Multi-Output Support Vector Regression technique to capture nonlinear relationships between independent variables (fluid type, turbine inlet pressure, turbine inlet temperature, turbine outlet pressure, and mass flow rate) and dependent variables (pump power input, waste heat input, and turbine specific work). The Osprey optimization algorithm is used to address the multi-objective optimization problem, with the proposed Pareto-based Osprey Optimization Algorithm and the Multi-Objective Particle Swarm Optimization technique being employed to evaluate critical performance and economic parameters such as system thermal efficiency, net power output, and the levelized cost of electricity. The results of the optimization strategies indicate that the M-SVR model's prediction accuracy is significantly improved after parameter optimization, with the model returning high R 2 and low Mean Square Error values of 0.991 and 0.00216, respectively. The Pareto-Based Osprey Optimization Algorithm optimizer identifies the best working fluid as Isobutane/Isopentane in a ratio of 66:34, with optimal turbine inlet pressure and temperature of 15 bars and 218 °C, respectively. In conclusion, the Organic Rankine Cycle model at these optimal conditions achieves a cycle efficiency of 19.93% and an Levelized Cost of Electricity value of 0.0353 USD/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural-based time series forecasting of loss of coolant accidents in nuclear power plants

During the last few years, deep learning in neural networks has demonstrated impressive successes in the areas of computer vision, speech and image recognition, text generation, and many others. However, sensitive engineering areas such as nuclear engineering benefited less from these efficient techniques. In this work, deep learning expert systems are utilized to model and predict time series progression of a design-basis nuclear accident, featuring a loss of coolant accident. Two major findings are accomplished in this work. First, the ability to train expert systems with high accuracy, which could help nuclear power plant operators to figure out plant responses during the accident. Second, building fast, efficient, and accurate deep models to simulate nuclear phenomena, which could be valuable to nuclear computational science. In this work, large amount of time series data is obtained from simulation tools by simulating different conditions of the base-case/nominal accident scenario. Four critical outputs/responses are monitored during the accident (e.g. temperature, pressure, break flow rate, water level). Two approaches are adopted in this work. The first approach is to use feedforward deep neural networks (DNN) to fit all time steps and outputs in a single model. The second approach is to use long short-term memory (LSTM) to fit all time steps together for each reactor response separately. Both DNN and LSTM demonstrate very good performance in predicting the test and base-case scenarios, with accuracy as low as 92% and as high as 99%, where these test scenarios are unknown to the expert systems and are not included in the model training. In addition, both approaches demonstrate a significant reduction in computational costs, as the deep expert system is able to accurately predict the accident 100,000 times faster than the original simulation tool. Given sufficient data, the methodology adopted in this study demonstrates that DNN/LSTM expert systems can be used as a decision support system to model advanced time series phenomena within nuclear power plants with high accuracy and negligible computational costs.

42 ENGINEERING↗

Continuous caustic aqueous phase electrochemical reforming (CAPER) of ethanol for producing compressed hydrogen

Caustic Aqueous Phase Electrochemical Reforming (CAPER) of ethanol produces pure compressed H 2 at lower voltages, temperatures, and energy requirements than conventional electrolysis, while capturing carbonaceous products. The CAPER flow reactor consists of stainless steel endplates, stainless steel current collectors, and a Teflon flow field. The electrodes are prepared using commercial palladium nanoparticles on carbon support for the anode and platinum nanoparticles on carbon support for the cathode. The catalyst metal loading was 1 mgcm –2 on a 10cm 2 carbon cloth for both electrodes. Our CAPER reactor produces pure H 2 at 80bar and 80°C applying voltages at ≤0.5V. The only gas-phase product detected was H 2 and any carbonaceous products were contained in the liquid phase. The H 2 was produced with 97±4% faradaic efficiency. Further, operating at smaller electrode separation distances (4mm) and 80°C increased the current density. The highest lower heating value efficiency achieved was 28% at a flow rate of 0.05mLmin –1 and an applied voltage of 0.5V. The compressed H 2 was produced at ≤20 kWh kg –1 , which is much lower than electrolysis systems that require upwards of 50 kWh kg –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling gas migration through clay-based buffer material using coupled multiphase fluid flow and geomechanics with stress-dependent gas permeability

A model for gas migration through clay-based buffer material is developed for modeling gas generation and migration associated with deep geologic nuclear waste disposal. The model is based on a multiphase fluid flow and geomechanics simulator that is adapted to consider enhanced gas flow when gas pressure is high enough to approach the confining stress magnitude. A key feature in the model is a direct coupling between gas permeability and stress, through a non-linear stress-dependent permeability function. The model was first tested and calibrated by modelling two different laboratory gas migration tests on Wyoming (MX-80) bentonite samples. The calibrated model was then applied to model gas migration through a bentonite buffer of a large-scale gas injection test (Lasgit) conducted at the Äspö Hard Rock Laboratory in Sweden. Observed preferential gas migration along interfaces (between compacted blocks and along the canister surface) required explicit representation of such interfaces in the model. The model with the stress-dependent gas permeability accurately captured observed experimental responses in terms of gas breakthrough time, peak gas pressure, and cumulative gas flow rates. The calibrated model was finally applied to simulate migration of hydrogen gas generated within a breached nuclear waste canister over 10,000 years, involving migration of much larger gas volumes. For the considered gas generation rate and host rock properties, the generated gas could migrate through the bentonite buffer and released into the surrounding host rock at a maximum gas pressure somewhat higher than the initial total stress, though a significant amount of hydrogen remained within the buffer. This modelling sets the stage for further detailed analysis of the impact of hydrogen gas generation on the long-term performance of nuclear waste repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Comparative experimental study of heat transfer processes in accumulation energy recovery exchangers

In this study, an experimental comparison between three different energy accumulating ceramic heat exchangers for energy recovery in ventilation systems was presented. The units were selected to represent three different approaches on the energy recovery process: honeycomb structure with more accumulation mass (more energy can be stored in one unit)- Unit 1.1, honeycomb structure with lower accumulation mass- Unit 1.2, and a rectangular structure with expanded heat transfer surface- Unit 1.3. The achieved results are useful for the future application of such units in ventilation systems. It was established that all evaluated units demonstrated an acceptable effectiveness of thermal energy recovery from the exhaust air. Their average energy recovery efficiency ranged between 70 % and 80 %, aligning with expected performance benchmarks for regenerative heat exchangers employed in contemporary mechanical ventilation systems. It was also established that the factor which has the highest impact on thermal effectiveness is the heat transfer surface available in the tested heat exchangers. Units with the highest number of channels (i.e., with the highest amount of single channel walls, which can be used for heat transfer) achieve the highest thermal effectiveness. However, higher thermal effectiveness can negatively affect the ventilation potential of the units. Unit 1.3, which was characterized by the highest thermal efficiency, was also characterized by the lowest achievable flow rate. It was also found that the important technical aspect that should be taken into account when analyzing accumulation energy recovery units is also the fluctuation of the supply air temperature. The ability to ensure minimal temperature fluctuations is a significant operational advantage, as it ensures a higher level of safety at lower outside temperatures.

Energy recovery↗

Development of an innovative process for post-combustion CO 2 capture to produce high-value NaHCO 3 nanomaterials

An innovative post-combustion process using aqueous sodium glycinates solutions (SGS) for CO 2 capture from a split flue gas stream emitted from the 600 MWe coal power plant, used in the Wolverine Clean Energy Venture (WCEV) project, was developed in Aspen Plus v.10. The flue gas flow rate used in the process was 12.43 kg/s (at 353.15 K and 101.33 kPa) and contained 0.0023 and 13.33 mol% of SO 2 and CO 2 , respectively. The overall process includes 5 main units designed to remove all SO 2 and capture more than 90 mol% of CO 2 in the flue gas stream, while producing high-value, salable sodium bicarbonate (NaHCO 3 ) nanomaterials to offset the total process costs. The hydraulics, mass transfer characteristics, and process performance obtained using Aspen Plus were discussed. Also, the capital expenditure (CAPEX), operating expenditure (OPEX), and Levelized cost of CO 2 capture (LCOC) were calculated to assess the feasibility of this process. Further, the hydraulics in the SO 2 washing and CO 2 capture units showed a pressure drop of 12 and 1 kPa, respectively, and the behaviors of the liquid holdup and normalized packing specific wetted surface area were similar in both units. The gas-side mass transfer coefficients were orders of magnitude greater than the liquid-side mass transfer coefficients. The process was able to capture 2.352 kg/s of CO 2 and produce 4.486 kg/s of valuable NaHCO 3 nanomaterials. Also, the calculated CAPEX, OPEX, and LCOC of the process for a 30-year plant lifetime were ($\$ $4,450,552), (233.00 $\$ $/h) and (35.49 $\$ $/ton of CO 2 captured), respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the effects of pressure management for the Williston basin Brine Extraction and Storage Test (BEST) site using machine learning

Active reservoir management (ARM) through brine extraction can reduce pressure buildup during large-scale implementation of carbon capture and storage (CCS) projects. This study used machine learning (ML)-assisted approaches to analyze bottomhole pressure (BHP) responses to various brine injection and extraction scenarios. Field monitoring data were collected over a 2-year operation period at two injection wells and one extraction well (about 400 meters away) as part of a Brine Extraction and Storage Test (BEST) in the North Dakota portion of the Williston Basin. Injection activities increased the BHPs at the injection wells by around 0.70 MPa (~100 psi) during the operation period. Extraction activities demonstrated the capability to decrease the BHPs at the injection wells by approximately 0.21–0.34 MPa (30–50 psi) depending on the ratio of the extraction and injection well flow rates (the “extraction ratio” – a normalization procedure used in the analysis). The pressure reduction provided by the extraction well equated to 30%–50% of the pressure buildup at the injection well. Furthermore, this work shows how ML analytics can play a key role in estimating reservoir pressure responses for complex injection and extraction activities during pressure management practices of CCS projects.

58 GEOSCIENCES↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Generalized Analysis of Dynamic Flow Fouling on Heat Transfer Surfaces

Several energy applications involve flow of untreated heat transfer fluids that contain trace amounts of mineral salts, such as calcium carbonate and calcium sulfate, which show reverse solubility with temperature. The gradual accretion of these salts onto the heat transfer surfaces causes fouling that degrades thermal performance over time. While fouling of bare surfaces has been extensively studied, fouling of nonwetting superhydrophobic or liquid-infused surfaces is less understood, especially under dynamic flow conditions. This study presents a systematic experimental analysis to elucidate dynamic flow fouling of calcium carbonate and calcium sulfate on smooth, superhydrophobic and liquid-infused surfaces in a generalized manner. Here, copper tubes with modified inner surface wettability are fabricated and subjected to forced convection at different flow rates and fouling salt concentrations. Fouling characteristics of the two salts on the different surfaces are examined through microstructural analysis, and quantified in terms of asymptotic fouling resistance that measures the total extent of fouling, and a threshold time, which correlates to the onset of significant fouling. Using Taguchi design of experiments, the study reports, for the first time, closed-form analytical relationships for the asymptotic fouling thermal resistance and threshold time on the Reynolds number, dimensionless concentration of fouling agent and dimensionless infused liquid viscosity that represents the different surface types in a unified manner. It is shown that the analytical model accurately predicts the fouling characteristics in up to about 97% of the data, based on which contour maps of optimum surface designs for minimizing fouling resistance are presented. The results provide information on designing surfaces for reduced fouling or for estimating the fouling characteristics for a given surface in applications.

36 MATERIALS SCIENCE↗

The role of moisture in MgCl 2 salt: A multiscale approach to TES performance

This study presents a comprehensive multiscale analysis to evaluate the influence of moisture on the thermal performance of thermal energy storage systems using magnesium chloride (MgCl 2 ) as the phase-changing material. The system uses graphite foam with 90% relative density to enhance thermal conductivity. The analysis includes thermal conductivity calculations and specific heat capacity for different hydrate phases of MgCl 2 : Anhydrous, Mono, Di, Tetra, and Hexa. These properties were evaluated for the first time using the phonon density of states from Density Functional Theory simulations. Results showed that thermal conductivity decreased, while specific heat capacity increased by a factor of two as the phase changed from anhydrous to hexahydrate. Meso-scale models were created to account for the anisotropy of graphite foam and property variations of the MgCl 2 hydrate phases. Asymptotic Expansion homogenization simulations determined the anisotropic thermal conductivity for all phases. This unique methodology improved simulation accuracy, which matched experimental data for anhydrous MgCl 2 . A parametric study examined various operating conditions and their effect on TES performance. It revealed that higher charging temperatures did not enhance exergy efficiency, but increased discharge mass flow rates improved it due to better heat transfer. Thermal performance evaluated by the exergy efficiency remained consistent across hydrate systems under the tested conditions. Furthermore, the study suggests that this uniformity is linked to missing key data, particularly latent heat and melting point for different hydrates. Overall, it highlights the importance of multiscale effects and accurate material properties in designing and optimizing TES systems.

Molten salt degradation↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Automotive fuel cell stack and system efficiency and fuel consumption based on vehicle testing on a chassis dynamometer at minus 18 °C to positive 35 °C temperatures

In this work we present an in-depth laboratory technology assessment of a 2016 Toyota Mirai Fuel Cell (FC) vehicle based on chassis dynamometer testing. The 114.6 kW FC stack has a high dynamic response, which makes this powertrain a FC-dominant hybrid electric vehicle. The measured peak efficiency is 66.0% FC stack and 63.7% FC system with an idle hydrogen flow rate of 4.39 g/hr. The high FC system efficiencies at low loads match typical vehicle power spectrums, resulting in a high average vehicle efficiency of 62% compared to 45% and 23% for a hybrid electric vehicle and a conventional vehicle, respectively. An energy breakdown accounts for the FC stack losses, FC system losses, air compressor loads, and heater loads for different drive cycles and different thermal conditions. The cold-start North American city drive cycle (UDDS) energy consumption values are, respectively, 758, 581, 226, and 321 Wh/km at ambient conditions of -18 degrees C, -7 degrees C, -25 degrees C and 35 degrees C with 850 W/m 2 of solar loading. The FC system shutdown and startup processes at temperatures below the freezing point contribute to the increased hydrogen consumption. Additionally, the raw test data files are available for download, thus providing the research community with a public reference data on a modern production automotive FC system.

08 HYDROGEN↗

Parametric study of operating conditions of an SO 2 -depolarized electrolyzer

Large-scale hydrogen generation is needed to satisfy both existing commercial demands and the realization of a hydrogen economy. The hybrid sulfur cycle has the potential to meet this goal without the use of fossil fuels. The ability to model and predict how the electrolyzer step of the cycle is affected by independent and interdependent variables is vital to maximizing the efficiency of the overall cycle. Herein, we report that our parametric study of the SO 2 -depolarized electrolyzer, representing one half of the overall reaction cycle, has identified desirable conditions and will help guide further development for operation that will achieve the benchmarks for economic feasibility. We discuss the interactions among the inlet flow rates, applied current, and cell temperature and pressure, on the resulting cell voltage and acid concentration in the liquid product stream. For example, we find that using a sulfonated polybenzimidazole (s-PBI) membrane and a platinum catalyst, a constant current density of either 0.5 A cm -2 , 0.75 A cm -2 , or 1 A cm -2 with an acid concentration of 65 wt% H 2 SO 4 can be produced at a cell voltage of 0.59 V, 0.63 V, and 0.67 V, respectively, by maintaining a cell temperature of 130 °C, a pressure of 2 bar, and a water-to-SO 2 stoichiometry of 2.77. Finally, we discuss directions for future research based on the findings in this manuscript.

08 HYDROGEN↗