Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Data From: Simulating bioclogging effects on dynamic riverbed permeability and infiltration, Water Resources Research

We collected a time series of Russian River infiltration rates to parameterize stochastic model development of infiltration conditions as a function of bioclogging. The time series of infiltration were collected from the Russian River Riverbank Filtration site located in Sonoma County California. Infiltration datasets are shown in units of m/day and were obtained using a seepage meter in 2012. To address the combined effects of bioclogging and disconnection on infiltration, we developed numerical representations of bioclogging processes based on these datasets using a within a one-dimensional, variably saturated flow model representing losing-connected and losing-disconnected rivers. All models and bioclogging formulations were used to create synthetic test cases for bioclogging.This research was supported by the Jane Lewis Fellowship from the University of California, Berkeley, the Sonoma County Water Agency (SCWA), the Roy G. Post Foundation Scholarship, the U.S. Department of Energy, Office of Science Graduate Student Research (SCGSR) Program, U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research under award DE-AC02-05CH11231, and the UFZ-Helmholtz Centre for Environmental Research, Leipzig, Germany.

54 ENVIRONMENTAL SCIENCES↗

Procedure for the Transfer of Polymer Films Onto Porous Substrates with Minimized Defects

The fabrication of devices containing thin film structures necessitate the transfer of these films onto the surfaces of arbitrary support substrates. Accomplishing this transfer in a highly controlled, mechanized, and reproducible manner would eliminate the creation of macroscale defect structures (e.g. tears, cracks, and wrinkles) within the thin film that would otherwise have a negative impact on ultimate device performance. In this work, we describe a general protocol for the highly controlled and mechanized transfer of a polymeric thin film onto an arbitrary porous support substrate for eventual use as a water filtration membrane device. Specifically, we fabricate a block copolymer (BCP) thin film on top of a sacrificial, water-soluble poly(acrylic acid) (PAA) layer and silicon wafer substrate. We then utilize a custom-designed, 3D-printed transfer tool and drain chamber system to deposit, lift-off, and transfer the BCP thin film onto the center of a porous anodized aluminum oxide (AAO) support disc. The transferred BCP thin film is shown to be consistently placed onto the center of the support surface due to the guidance of the meniscus. Additionally, we compare our mechanized transfer-processed thin films to those that have been transferred by other commonly used techniques, such as by hand with the use of tweezers. Optical inspection and image analysis of the transferred thin films from the mechanized process confirm that little-to-no macroscale inhomogeneities or plastic deformations are produced, as compared to the multitude of tears and wrinkles produced from manual transfer by hand. Our findings indicate that the proposed strategy for thin film transfer can reduce defects when compared to other methods across many systems and applications.

36 MATERIALS SCIENCE↗

Determination of interstellar O parameters using the first two years of data from the Interstellar Boundary Explorer

The direct measurements of interstellar matter by the Interstellar Boundary Explorer (IBEX) mission have opened a new and important chapter in our study of the interactions that control the boundaries of our heliosphere. Here we derive for the quantitative information about interstellar O flow parameters from IBEX low-energy neutral atom data for the first time. Specifically, we derive a relatively narrow four-dimensional parameter tube along which interstellar O flow parameters must lie. Along the parameter tube, we find a large uncertainty in interstellar O flow longitude, 76.°0 ± 3.°4 from χ {sup 2} analysis and 76.°5 ± 6.°2 from a maximum likelihood fit, which is statistically consistent with the flow longitude derived for interstellar He, 75.°6 ± 1.°4. The best-fit O and He temperatures are almost identical at a reference flow longitude of 76°, which provides a strong indication that the local interstellar plasma near the Sun is relatively unaffected by turbulent heating. However, key differences include an oxygen parameter tube for the interstellar speed (relation between speed and longitude) that has higher speeds than those in the corresponding parameter tube for He, and an upstream flow latitude for oxygen that is southward of the upstream flow latitude for helium. Both of these differences are likely the result of enhanced filtration of interstellar oxygen due to its charge-exchange ionization rate, which is higher than that for helium. Furthermore, we derive an interstellar O density near the termination shock of 5.8{sub −0.8}{sup +0.9}×10{sup −5} cm{sup −3} that, within uncertainties, is consistent with previous estimates. Thus, we use IBEX data to probe the interstellar properties of oxygen.

79 ASTRONOMY AND ASTROPHYSICS↗

A RESOLVED NEAR-INFRARED IMAGE OF THE INNER CAVITY IN THE GM Aur TRANSITIONAL DISK

We present high-contrast H -band polarized intensity (PI) images of the transitional disk around the young solar-like star GM Aur. The near-infrared direct imaging of the disk was derived by polarimetric differential imaging using the Subaru 8.2 m Telescope and HiCIAO. An angular resolution and an inner working angle of 0.″07 and r ∼ 0.″05, respectively, were obtained. We clearly resolved a large inner cavity, with a measured radius of 18 ± 2 au, which is smaller than that of a submillimeter interferometric image (28 au). This discrepancy in the cavity radii at near-infrared and submillimeter wavelengths may be caused by a 3–4 M {sub Jup} planet about 20 au away from the star, near the edge of the cavity. The presence of a near-infrared inner cavity is a strong constraint on hypotheses for inner cavity formation in a transitional disk. A dust filtration mechanism has been proposed to explain the large cavity in the submillimeter image, but our results suggest that this mechanism must be combined with an additional process. We found that the PI slope of the outer disk is significantly different from the intensity slope obtained from HST /NICMOS, and this difference may indicate the grain growth process in the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Porous cobalt spheres for high temperature gradient magnetically assisted fluidized beds

Porous metallic cobalt spheres have been prepared as high temperature capable media for employment in gradient magnetically assisted fluidization and filtration technologies. Cobalt impregnated alginate beads are first formed by extrusion of an aqueous suspension of Co3O4 into a Co(II) chloride solution. The organic polymer is thermally decomposed yielding cobalt oxide spheres, followed by reduction to the metallic state, and densification. Cobalt beads have been produced with porosities ranging between 10 and 50%, depending upon sintering conditions. The product media have been characterized by scanning electron microscopy (SEM), nitrogen adsorption porosimetry, and vibrating sample magnetometry. c2003 Elsevier Science Ltd. All rights reserved.

NASA Discipline Life Support Systems↗

Acutely elevated vasopressin increases circulating concentrations of cortisol and aldosterone in fasting northern elephant seal (Mirounga angustirostris) pups

The physiological actions of vasopressin (VP) in marine mammals are not well defined. To help elucidate its hormonal and renal effects in this group of mammals, northern elephant seal (Mirounga angustirostris) pups (N=7; 99+/-4 kg) were first infused with 0.9% saline (control; 220 ml), followed 24 h later with VP (as a 20 ng kg(-1) bolus, then 2 ng kg(-1) min(-1) for approximately 35 min in 225+/-16 ml saline). During both control and VP periods, blood samples were collected prior to infusion, and 15, 30, 60, 120 min and 24 h after infusion to examine the hormonal responses of the pups to VP. Renal responses were quantified from 24 h urine samples obtained prior to infusion (control) and 24 h post-infusion. Compared to the control period, infusion of VP increased plasma concentrations of cortisol over a 120 min period and aldosterone over 30 min, while plasma renin activity (PRA) was decreased for a 120 min period. The plasma urea:creatinine ratio was elevated following infusion of VP. Urine output and osmotic clearance were increased by 69+/-18% (mean +/- S.E.M.) and 36+/-10%, respectively, but free water clearance and glomerular filtration rate were not significantly altered 24 h post-infusion of VP. Solute (osmolality, Na(+), K(+) and Cl(-)) excretion and fractional excretion of electrolytes were also increased when compared to control values. The increase in cortisol concentration suggests that VP may possess corticotropin releasing hormone-like activity in elephant seals. If osmotic diuresis and natriuresis are typical consequences of elevated [VP] in fasting pups, then not increasing VP normally during the fast may serve as a protective mechanism to avoid the potential loss of Na(+) induced by elevated [VP]. Therefore, under natural fasting conditions, pups may be highly sensitive to small changes in [VP], resulting in the maintenance of water and electrolyte balance.

Non-NASA Center↗

Body water handling in response to hypertonic-saline induced diuresis in fasting northern elephant seal pups (Mirounga angustirostris)

During natural fasting conditions in postweaned northern elephant seal (NES) (Mirounga angustirostris) pups, urinary water loss is minimized and percent total body water (TBW) is maintained constant. However, following infusion of hypertonic saline, glomerular filtration rate (GFR) and urine output increased in fasting pups. Therefore, we quantified the magnitude of the hypernatremia-induced diuresis relative to the animal's total body water (TBW) pool and the percentage of filtered water reabsorbed. Following a 24 h control period, naturally fasting NES pups (n=7) were infused (4 ml min(-1)) with hypertonic saline (16.7%) at a dose of 3 mmol NaCl kg(-1) body mass. Total body water was estimated prior to infusion by tritium dilution, GFR was estimated by standard creatinine clearance, and urine output (V) was measured for 24 h during the control and post infusion periods. Percentage of filtered water reabsorbed was calculated as (1-(V/GFR))x100. Twenty-four hours following the infusion, GFR (control: 69+/-12 ml min(-1) and post-infusion: 118+/-19 ml min(-1); mean+/-S.E.) increased 77+/-28% above control and the percentage of filtered water reabsorbed was decreased 0.4+/-0.1%. The increase in urine output (control: 218+/-47 ml d(-1) and post-infusion: 883+/-92 ml d(-1)) accounted for 1.7+/-0.2% of the pups' TBW. The hypernatremia-induced diuresis was accompanied by the loss of body water indicating the lack of water retention. Although the 77% increase in GFR was only associated with a 0.4% decrease in the percentage of filtered water reabsorbed, this decrease was significant enough to result in a 4-fold increase in urine output. Despite the observed diuresis, fasting NES pups appear to possess an efficient water recycling mechanism requiring only a small percentage of body water to excrete an excess salt load. This water recycling mechanism may allow pups to avoid negative perturbations in body water as they initiate feeding in a marine environment following the fast.

Non-NASA Center↗

Renal effects of fresh water-induced hypo-osmolality in a marine adapted seal

With few exceptions, marine mammals are not exposed to fresh water; however quantifying the endocrine and renal responses of a marine-adapted mammal to the infusion of fresh water could provide insight on the evolutionary adaptation of kidney function and on the renal capabilities of these mammals. Therefore, renal function and hormonal changes associated with fresh water-induced diuresis were examined in four, fasting northern elephant seal ( Mirounga angustirostris) (NES) pups. A series of plasma samples and 24-h urine voids were collected prior to (control) and after the infusion of water. Water infusion resulted in an osmotic diuresis associated with an increase in glomerular filtration rate (GFR), but not an increase in free water clearance. The increase in excreted urea accounted for 96% of the increase in osmotic excretion. Following infusion of fresh water, plasma osmolality and renin activity decreased, while plasma aldosterone increased. Although primary regulators of aldosterone release (Na(+), K(+) and angiotensin II) were not significantly altered in the appropriate directions to individually stimulate aldosterone secretion, increased aldosterone may have resulted from multiple, non-significant changes acting in concert. Aldosterone release may also be hypersensitive to slight reductions in plasma Na(+), which may be an adaptive mechanism in a species not known to drink seawater. Excreted aldosterone and urea were correlated suggesting aldosterone may regulate urea excretion during hypo-osmotic conditions in NES pups. Urea excretion appears to be a significant mechanism by which NES pups sustain electrolyte resorption during conditions that can negatively affect ionic homeostasis such as prolonged fasting.

NASA Center ARC↗

Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.

Review, Tutorial↗

Increased renal tubular sodium reabsorption during exercise-induced hypervolemia in humans

We tested the hypothesis that renal tubular Na(+) reabsorption increased during the first 24 h of exercise-induced plasma volume expansion. Renal function was assessed 1 day after no-exercise control (C) or intermittent cycle ergometer exercise (Ex, 85% of peak O(2) uptake) for 2 h before and 3 h after saline loading (12.5 ml/kg over 30 min) in seven subjects. Ex reduced renal blood flow (p-aminohippurate clearance) compared with C (0.83 +/- 0.12 vs. 1.49 +/- 0.24 l/min, P < 0.05) but did not influence glomerular filtration rates (97 +/- 10 ml/min, inulin clearance). Fractional tubular reabsorption of Na(+) in the proximal tubules was higher in Ex than in C (P < 0.05). Saline loading decreased fractional tubular reabsorption of Na(+) from 99.1 +/- 0.1 to 98.7 +/- 0.1% (P < 0.05) in C but not in Ex (99.3 +/- 0.1 to 99.4 +/- 0.1%). Saline loading reduced plasma renin activity and plasma arginine vasopressin levels in C and Ex, although the magnitude of decrease was greater in C (P < 0.05). These results indicate that, during the acute phase of exercise-induced plasma volume expansion, increased tubular Na(+) reabsorption is directed primarily to the proximal tubules and is associated with a decrease in renal blood flow. In addition, saline infusion caused a smaller reduction in fluid-regulating hormones in Ex. The attenuated volume-regulatory response acts to preserve distal tubular Na(+) reabsorption during saline infusion 24 h after exercise.

NASA Discipline Cardiopulmonary↗

A Two-Stage Regenerable Filter for Collection and Disposal of Carbon Fines

NASA is investigating the use of the Plasma Pyrolysis Assembly (PPA), which is a methane post-processing technology with the goal to recover hydrogen from the Carbon dioxide Reduction Assembly (CRA) currently onboard the International Space Station (ISS). The PPA can theoretically recover 75% of hydrogen from methane produced by the CRA. During methane processing the PPA creates roughly 40 mg/hr of carbon dust when operating at 4 crew member levels. The unwanted fines need to be removed from the stream to prevent any clogging of downstream components. The Regenerable Carbon Filter (RCF) was designed by Umpqua Research Company to address the carbon particulate created in the PPA. The RCF includes two stages. The first is an electrostatic precipitator designed to collect ultrafine particles. The second is a low pressure drop physical filter. Both filters are made of heat tolerant materials to allow regeneration of the filtration capacity by O2 oxidation of captured carbon. This paper will discuss the RCF hardware and test plans.

Filtration, Environmental Control, Life Support↗

Development of Challenge Aerosols for Testing Filters in Spacecraft Air Revitalization Systems

The common means for reducing particle concentrations in air in enclosed spaces, including in space habitats, are source prevention and particle removal by air filters. While air filtration and testing is a well-established discipline and industry, testing and classifying filters according to commonly used standards rely on a test aerosol that is often arbitrary and chosen for the convenience of the test method. In space habitats, the particle size distributions are expected to be quite different than the particle size distributions prescribed in test standards, due to the partial or low gravity environment affecting sedimentation of large particulates like hair or cloth fibers, or the introduction of planetary dust to the pressurized volume. This means that the efficacy of the filter will be quite different in the space habitat than specified according to a prevailing standard. This paper will present a means to specify and generate a “composite” test aerosol that is similar to the measured and reported particle sizes utilizing the International Space Station (ISS) as an example. Application of this test aerosol is expected to yield filter efficiencies and loading effects closer to what one can expect on the ISS and to be useful in determining filter lifetime and replacement cycles. The method can be tuned, within reason, to match other particle size distributions one may encounter, such as the intrusion of Lunar dust for a Lunar lander or habitat.

Filtration↗

Ceramic HEPA Filter Program

Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Activity Waste Pretreatment System Bench-Scale Testing: Supporting Integrated Testing and Facility Safety Analyses - 17171

The Low Activity Waste Pretreatment System (LAWPS) is being designed to enable the direct feed of waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to be immobilized. Prior to construction of the LAWPS, pilot-scale integrated testing of the key unit operations (crossflow filtration, ion exchange using spherical resorcinol-formaldehyde (sRF) resin) will be conducted by a team led by Washington River Protection Solutions (WRPS) to increase the technology maturation level of the facility’s critical technology elements. As a part of this effort, Pacific Northwest National Laboratory (PNNL) has conducted a series of bench-scale (or engineering-scale) tests to perform two major objectives: (1) support pilot-scale integrated testing of the LAWPS by supplying information or performance data in advance of operating the pilot-scale facility; and (2) collect data needed to establish or confirm assumptions/approaches planned for implementation in the LAWPS safety basis. The first objective was focused in two technical areas: developing simulants that are representative of expected waste feed and can be produced at larger scales, and using these simulants in a bench-scale crossflow filter to establish expected solid-liquid separation performance. The crossflow filter was also used to observe the efficacy (with respect to filter production rate) of selected operational strategies. The second objective also included two technical areas: measuring the effect of sRF resin on hydrogen generation rate under irradiation, and demonstrating that the planned hydrogen management approach is effective and robust. The hydrogen management strategy involves fluidization of the sRF resin bed in the ion exchange columns and recirculating the liquid, a scenario that is planned for testing at full column height. The full height tests at PNNL also supported full-scale IX column testing conducted as part of the technology maturation plan. The experimental approaches used at PNNL in these four technical areas are summarized and selected key preliminary results are provided.

cross flow filtration↗

Feedstock and Catalyst Impact on Bio-Oil Production and FCC Co-Processing to Fuels

NREL’s thermochemical biomass conversion research is focused on ex-situ upgrading of biomass fast-pyrolysis (FP) vapors as an efficient and economical route to completely biogenic pyrolysis-based fuel precursors, potential fuels, and value-added chemicals depending on catalyst choice and process conditions. In this approach, biomass vapors are generated via fast pyrolysis with destabilizing vapor components (char, inorganics, tar aerosols) removed by hot gas filtration to produce conditioned vapors more responsive to catalytic upgrading. A Davison Circulating Riser (DCR), a petroleum industry standard for fluidized catalytic cracking (FCC) catalyst evaluation, was coupled with a custom pyrolyzer system designed to produce consistent composition pyrolysis vapors as feed to the DCR. The coupled system is shown below (Figure 1). Pyrolysis vapors, derived from pure hardwood and softwood, were upgraded using commercially available and laboratory modified zeolite-based catalysts. Upgraded oils were analyzed via 31P and 13C NMR spectroscopy, GCxGC-TOF/MS, carbonyl and ultimate analysis (CHNO), and micro distillation to assess both oil chemistry and distillation behavior as they relate to catalyst and feedstock type for producing fungible hydrocarbon product liquids. Measured process parameters identified from technoeconomic process analysis included achieving oil oxygenate contents of 20% or less, carbon-conversion efficiencies of 30% or more, and catalyst coking rates of 10% or less. A proprietary modified zeolite catalyst from Johnson Matthey produced oils that met these requirements. Using the DCR equipped with a proprietary nozzle system, a second approach focused on reducing the carbon intensity of petroleum-derived hydrocarbon fuels by FCC co-processing these CFP oils with petroleum vacuum gas oil (VGO) to produce biogenic carbon containing fuels. The vapor-phase upgrading results demonstrated for the first time the feasibility of producing refinery-compatible hydrocarbon fuel intermediates entirely from biomass-derived fast-pyrolysis vapors using an industry-accepted DCR system for catalytic upgrading. The co-processing results demonstrated the feasibility of using CFP oils with VGO feeds in FCC refinery operations to produce biogenic carbon containing fuels.

bio-oil↗

Healthy Buildings Guide for Small Businesses: A Quick Reference to Improve Indoor Air Quality (Restaurants Excluded)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time – not just during a public health crisis – and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures – the building owner and business owner can be different parties – so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗