Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Porewater chemistry in Typha-dominated brackish tidal marsh, PIE LTER, Plum Island Sound, MA, July 2022–September 2024

This dataset contains profile measurements of porewater constituents taken on 3-4 days across the growing seasons in 2022, 2023, and 2024 in a tidal brackish marsh within the Plum Island Ecosystems Long Term Ecological Research site (PIE LTER), located in the Plum Island Sound, Massachusetts (MA). Measurements were taken to monitor changes in porewater chemistry induced by seasonal saltwater intrusion at the site. Samples were taken in two locations: one was close to the creek bank and the other in the marsh interior. Water was sampled from 2-5 depths between the surface to 50cm using a sipper consisting of a hollow stainless steel rod with an opening at the end similar to that described in (Berg & McGlathery, 2001). The rod was pushed into the sediment to the desired depth, typically every 10cm, and water samples were taken by syringe. Water was not obtained at all depths. Samples were preserved and analyzed in the lab. Metadata files Typha_porewater_sipper_dd.csv and Typha_porewater_sipper_flmd.csv contain detailed information on data variables, sampling and QA/QC methods, and site location.

54 ENVIRONMENTAL SCIENCES↗

Introduction to Tools and Techniques for Surface Sampling on Europa

The NASA Jet Propulsion Laboratory (JPL) is studying excavation and collection of a sample from an icy surface for a potential landed mission to Europa. Europa presents unique challenges in planetary sampling. Very little is known about the local topography and material composition of the surface. The environmental conditions of being cryogenically cold (80-130K), low gravity (~1/7th Earth), no atmosphere, low lighting conditions, and limited ground in the loop opportunities have forced JPL to look at sampling differently than past missions. Interacting with the surface of the Jovian moon requires a sampling system that is robust to local topography on the scale of the lander and/or the tool. In addition, the sampling system must be capable both of detecting faults and automatically adjusting to them to achieve the mission objectives without ground in the loop feedback. Presented here is an overview of a sampling system concept that involves a two-stage approach for collecting a sample. The first stage uses an excavation tool to prepare the surface site for sample collection by removing the top layer of irradiated material and clearing tailings from the hole. The second stage then generates and collects a sample for delivery to instruments on-board a lander. Also presented is an introduction for how autonomy and sensing technologies might be employed to enable mission success.

Tevere, Erica L.↗

Space Environment Effects on Stability of Medications Flown on Space Shuttles and the International Space Station (ISS)

The purpose is to assess physical and chemical degradation of select pharmaceutical formulations from the Shuttle and ISS medical kits. Eleven pharmaceuticals dispensed as different dosage forms were selected based on their physical / chemical characteristics and susceptibility to environmental factors such as, temperature, humidity and light sensitivity. When available, ground-controls of the study medications with matching brand and lot numbers were used for comparison. Samples retrieved from flight were stored along with their matching controls in a temperature and humidity controlled environmental chamber. Temperature, humidity, and radiation data from the Shuttle and ISS were retrieved from onboard HOBO U12 Temp/RH Data Loggers, and from passive dosimeters. Physical and chemical analyses of the pharmaceuticals were conducted using validated United States Pharmacopeia (USP) methods. Results indicated degradation of 6 of the 11 formulations returned from space flights. Four formulations, Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, and ciprofloxacin tablets depicted discoloration after flight. Chemical content analyses using High or Ultra Performance Liquid Chromatography (HPLC / UPLC) methods revealed that dosage forms of Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, lidocaine, ciprofloxacin and mupirocin contained less than 95% of manufacturer s labeled claim of active drug compound. Shuttle and ISS environments affect stability and shelf life of certain mediations flown on these missions. Data analysis is in progress to examine the effect of specific space flight environmental factors on pharmaceutical stability. The degradation profiles generated from ground studies in analog environments will be useful in establishing predictive shelf-life profiles for medications intended for use during long-term space exploration missions.

Daniels, Vernie↗

Drilling, Coring and Sampling Using Piezoelectric Actuated Mechanisms: From the USDC to a Piezo-Rotary-Hammer Drill

NASA exploration missions are increasingly including sampling tasks but with the growth in engineering experience (particularly, Phoenix Scout and MSL) it is now very much recognized that planetary drilling poses many challenges. The difficulties grow significantly with the hardness of sampled material, the depth of drilling and the harshness of the environmental conditions. To address the requirements for samplers that could be operated at the conditions of the various bodies in the solar system, a number of piezoelectric actuated drills and corers were developed by the Advanced Technologies Group of JPL. The basic configuration that was conceived in 1998 is known as the Ultrasonic/Sonic Driller/Corer (USDC), and it operates as a percussive mechanism. This drill requires as low preload as 10N (important for operation at low gravity) allowing to operate with as low-mass device as 400g, use an average power as low as 2- 3W and drill rocks as hard as basalt. A key feature of this drilling mechanism is the use of a free-mass to convert the ultrasonic vibrations generated by piezoelectric stack to sonic impacts on the bit. Using the versatile capabilities f the USDC led to the development of many configurations and device sizes. Significant improvement of the penetration rate was achieved by augmenting the hammering action by rotation and use of a fluted bit to remove cuttings. To reach meters deep in ice a wireline drill was developed called the Ultrasonic/Sonic Gopher and it was demonstrated in 2005 to penetrate about 2-m deep at Antarctica. Jointly with Honeybee Robotics, this mechanism is currently being modified to incorporate rotation and inchworm operation forming Auto-Gopher to reach meters deep in rocks. To take advantage of the ability of piezoelectric actuators to operate over a wide temperatures range, piezoelectric actuated drills were developed and demonstrated to operate at as cold as -200oC and as hot as 500oC. In this paper, the developed mechanisms will be reviewed and discussed including the configurations, capabilities, and challenges.

ultrasonic/Sonic Driller/ Corer (USDC)↗

MISSE 6, 7 and 8 Materials Sample Experiments from the International Space Station Materials and Processes Team

The International Space Station Materials and Processes (ISS M&P) team has multiple material samples on MISSE 6, 7 and 8 to observe Low Earth Orbit (LEO) environmental effects on Space Station materials. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. The ISS M&P team has participated in previous MISSE activities in order to better characterize the LEO effects on Space Station materials. This investigation will further this effort. Results for the following MISSE 6 samples materials will be presented: a comparison of anodize and chemical conversion coatings on various aluminum alloys, electroless nickel; AZ93 white ceramic thermal control coating with and without Teflon; Hyzod(TM) polycarbonate used to temporarily protect ISS windows; Russian quartz window material; reformulated Teflon (TM) coated Beta Cloth (Teflon TM without perfluorooctanoic acid (PFOA)) and a Dutch version of beta cloth. Discussion for current and future MISSE materials experiments will be presented. MISSE 7 samples are: deionized water sealed anodized aluminum Photofoil(TM); indium tin oxide (ITO)- coated Kapton(TM) used as thermo-optical surfaces; mechanically scribed tin-plated beryllium-copper samples for "tin pest" growth ( alpha/Beta transformation); Crew Exploration Vehicle (CEV) parachute soft goods. MISSE 8 sample: exposed "scrim cloth" (fiberglass weave) from the ISS solar array wing material, Davlyn fiberglass sleeve material, Permacel and Intertape protective tapes, and ITO-coated Kapton.

Kravchenko, Michael↗

On-ground Live Fuel Moisture Content Sampling Along California’s Central Coast Santa Lucia Preserve - Carmel Valley, CA

The ratio of water to dry mass within live plants is an important factor when determining the severity and intensity of potential wildfires. Currently, live fuel moisture content (LFMC) samples support wildland fire management, but are limited in number and spatial extent. In Monterey County, the only LFMC data to analyze spatial and temporal trends is collected by CalFire and the Los Padres National Forest Unit of the United States Forest Service across five long-term sampling sites. Our project aims to enhance the spatial coverage of current LFMC data being collected across Monterey County. Here, we share results from the ongoing work to monitor LFMC across Carmel Valley, CA. We evaluate LFMC data by environmental factors such as slope, aspect, topography, and species composition. We also place our LFMC samples in relation to nearby long-term sampling locations. We conclude by interpreting spatial and temporal trends in the preliminary data and discuss logistical challenges of establishing more long-term LFMC sampling sites to better represent the complex topography and vegetation composition of Central California.

On-ground↗

Mars Sample Return – An Overview of the Capture, Containment and Return System

The Mars Sample Return campaign aims at bringing back soil, rock and atmospheric samples from Mars to Earth to answer key questions about Mars’ biological evolution by means of four missions. The first one, Mars 2020, landed on the red planet on February 18, 2021 and has to date collected a number of samples through the Perseverance rover. The three subsequent missions will recover the sample tubes, launch them into Mars orbit and transport them back to Earth. These missions are currently in the planning and design stages of development and represent an international effort comprising NASA, ESA and many industry partners. The work presented here provides an overview of the current design and concept of operations of the NASA-provided Capture, Containment, and Return System (CCRS), which is the payload of the ESA-provided Earth Return Orbiter (ERO). ERO will rendezvous with the orbiting samples and CCRS will capture them, contain them and robotically insert them into a capsule that will return the samples to Earth, the Earth Entry System (EES). Three days before arrival on Earth, CCRS will release the EES, which will fly through space, enter Earth’s atmosphere, descend on a well-defined trajectory and safely land at the Utah Test and Training Range. The decision to implement Mars Sample Return will not be finalized until NASA’s completion of the National Environmental Policy Act process. This document is being made available for information purposes only.

Mars Sample Return↗

Metallicity beats sSFR: the connection between superluminous supernova host galaxy environments and the importance of metallicity for their production

ABSTRACT We analyse 33 Type I superluminous supernovae (SLSNe) taken from Zwicky Transient Facility (ZTF)’s Bright Transient Survey to investigate the local environments of their host galaxies. We use a spectroscopic sample of galaxies from the Sloan Digital Sky Survey (SDSS) to determine the large-scale environmental density of the host galaxy. Noting that SLSNe are generally found in galaxies with low stellar masses, high star formation rates (SFRs), and low metallicities, we find that SLSN hosts are also rarely found within high-density environments. Only $3\substack{+9 \\ -1}$ per cent of SLSN hosts were found in regions with two or more bright galaxies within 2 Mpc. For comparison, we generate a sample of 662 SDSS galaxies matched to the photometric properties of the SLSN hosts. This sample is also rarely found within high-density environments, suggesting that galaxies with properties required for SLSN production favour more isolated environments. Furthermore, we select galaxies within the IllustrisTNG simulation to match SLSN host galaxy properties in colour and stellar mass. We find that the fraction of simulated galaxies in high-density environments quantitatively match the observed SLSN hosts only if we restrict to simulated galaxies with metallicity 12 + log (O/H) ≤ 8.12. In contrast, limiting to only the highest specific star formation rate (sSFR) galaxies in the sample leads to an overabundance of SLSN hosts in high-density environments. Thus, our measurement of the environmental density of SLSN host galaxies appears to break the degeneracy between low metallicity and high sSFR as the driver for SLSN hosts and provides evidence that the most constraining factor on SLSN production is low metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Global atmospheric distribution and trend of methylchloroform /CH3CCl3/

Results of global measurements of the concentration of atmospheric methylchloroform, a man-made gas with potentially harmful environmental consequences, performed over a two-year period are presented. Samples were collected weekly at Pt. Barrow and Poker Flats, Alaska, Cape Meares, Oregon, Cape Kumakahi, Hawaii, Samoa, and Cape Grim, Tasmania, and yearly at the South Pole, and methylchloroform concentrations were determined by electron capture-gas chromatographic techniques. A latitudinal profile of CH3CCl3 concentrations derived from the data exhibits a bump at high northern latitudes, where most of the sources are located. Average concentrations calculated for the Northern and Southern Hemispheres showed a rise in global concentrations at a rate of 6.7 + or - 2.0%/year for the period from January 1979 to January 1981, with concentrations rising more slowly in 1980 than in 1979. These yearly increases are also smaller than earlier rates of increase, explainable by a reduction in the rate of emission increase, and are consistent with an atmospheric lifetime of between 6 and 10 years.

Rasmussen, R. A.↗

In-Situ Resource Utilization (ISRU) Development Program

The question "Why In-Situ Resource Utilization (ISRU)?" is addressed in this presentation. The reasons given concentrate on Cost reduction, Mass reduction, Risk reduction, the expansion of human exploration and presence and the enabling of industrial exploitation. A review of the Martian and Lunar resources available for ISRU is presented. Other ISRU concepts (i.e., In-Situ Consumable production (ISCP) and In-Situ Propellant Production (ISPP)) are introduced and further explained. The objectives of a Mars ISRU System Technology (MIST) include (1) the characterization of technology and subsystem performance for mission modeling and technology funding planning, (2) reduce risk and concerns arising from sample return and human missions utilizing ISRU, and (3) demonstrate the environmental suitability of ISRU components/processes and systems. A proof of concept demonstration schedule and a facility overview for MIST is presented.

Sanders, Jerry↗

Effects of Command and Control Vehicle (C2V) operational environment on soldier health and performance

The purpose of this project was to use NASA technology to assist the US Army in the assessment of motion sickness incidences and effects on soldier performance and mood states within the Command and Control Vehicle (C2V). Specific objectives were (1) to determine if there was a significant difference between three internal configurations of the C2V and/or between seats within these vehicles; (2) to determine if there was a significant difference between the park, move, or short-halt field conditions; and (3) to validate a method of converging indicators developed by NASA to assess environmental impact of long duration spaceflight on crewmembers, using a large sample of subjects under ground-based operational conditions.

NASA Center ARC↗

Electron Tomography of Nanoparticle Clusters: Implications for Atmospheric Lifetimes and Radiative Forcing of Soot

Nanoparticles are ubiquitous in nature. Their large surface areas and consequent chemical reactivity typically result in their aggregation into clusters. Their chemical and physical properties depend on cluster shapes, which are commonly complex and unknown. This is the first application of electron tomography with a transmission electron microscope to quantitatively determine the three-dimensional (3D) shapes, volumes, and surface areas of nanoparticle clusters. We use soot (black carbon, BC) nanoparticles as an example because it is a major contributor to environmental degradation and global climate change. To the extent that our samples are representative, we find that quantitative measurements of soot surface areas and volumes derived from electron tomograms differ from geometrically derived values by, respectively, almost one and two orders of magnitude. Global sensitivity studies suggest that the global burden and direct radiative forcing of fractal BC are only about 60% of the value if it is assumed that BC has a spherical shape.

vanPoppel, Laura H.↗

Miniaturized Environmental Scanning Electron Microscope for In Situ Planetary Studies

The exploration of remote planetary surfaces calls for the advancement of low power, highly-miniaturized instrumentation. Instruments of this nature that are capable of multiple types of analyses will prove to be particularly useful as we prepare for human return to the moon, and as we continue to explore increasingly remote locations in our Solar System. To this end, our group has been developing a miniaturized Environmental-Scanning Electron Microscope (mESEM) capable of remote investigations of mineralogical samples through in-situ topographical and chemical analysis on a fine scale. The functioning of an SEM is well known: an electron beam is focused to nanometer-scale onto a given sample where resulting emissions such as backscattered and secondary electrons, X-rays, and visible light are registered. Raster scanning the primary electron beam across the sample then gives a fine-scale image of the surface topography (texture), crystalline structure and orientation, with accompanying elemental composition. The flexibility in the types of measurements the mESEM is capable of, makes it ideally suited for a variety of applications. The mESEM is appropriate for use on multiple planetary surfaces, and for a variety of mission goals (from science to non-destructive analysis to ISRU). We will identify potential applications and range of potential uses related to planetary exploration. Over the past few of years we have initiated fabrication and testing of a proof-of-concept assembly, consisting of a cold-field-emission electron gun and custom high-voltage power supply, electrostatic electron-beam focusing column, and scanning-imaging electronics plus backscatter detector. Current project status will be discussed. This effort is funded through the NASA Research Opportunities in Space and Earth Sciences - Planetary Instrument Definition and Development Program.

Gaskin, Jessica↗

NASA Life Sciences Portal (NLSP): Supporting Scientific Transparency and Reproducibility

NASA’s Life Sciences Ports (NLSP) serves the scientific community by providing curated data from space life science experiment. The Human Research Program (HRP) with the help of NLSP is currently transforming their life sciences data archive systems and processes to improve compliance with the FAIR principles [1]. Some of these improvements will at the same time support the twin pillars of Open Science [2]: transparency of methods and reproducibility of results. Scientific transparency is marked by the easily intelligible communication of what has been investigated: what were the procedures for collecting sample and the characteristics of samples collected? what kinds of measurements were made, what were the environmental conditions of the measurements? What were the analysis techniques of the collected data? Reproducibility of the results and findings from the investigation requires a high level of transparency for all but the simplest investigations; the slightest deviation in communicating and replicating complex experimental procedures or data analyses can often yield quite different data and even findings, thwarting their validation. One of the ways the NLSP is aiming to improve the communication of scientific information is through the use of ontology-driven metadata. Ontologies are powerful, graph-based knowledge representation structures, which can be leveraged to increase data interoperability, the area of the FAIR principles in which many data systems most lack compliance. Over the past decade, there has been a concerted effort in the biomedical community to develop modular and narrowly focused domain and application-specific ontologies in a common, open-source framework, the Open Biological and Biomedical Ontology (OBO) Foundry [3]. The open sharing and modular nature of this effort promises huge increases in harmonized data sharing for systems that leverage these models. Which is in line with the FAIR Data Principles of Findability, Accessibility, Interoperability, and Reuse for scientific data management and stewardship. 1. Wilkinson, M.D., et al., The FAIR Guiding Principles for scientific data management and stewardship. Sci Data, 2016. 3: p. 160018. 2. National Academies of Sciences, E. and Medicine, Open Science by Design: Realizing a Vision for 21st Century Research. 2018, Washington, DC: The National Academies Press. 232. 3. Smith, B., et al., The OBO Foundry: coordinated evolution of ontologies to support biomedical data integration. Nat Biotechnol, 2007. 25(11): p. 1251-5.

Life Sciences data↗

NASA Life Sciences Portal (NLSP): Supporting Scientific Transparency and Reproducibility

NASA’s Life Sciences Ports (NLSP) serves the scientific community by providing curated data from space life science experiment. The Human Research Program (HRP) with the help of NLSP is currently transforming their life sciences data archive systems and processes to improve compliance with the FAIR principles [1]. Some of these improvements will at the same time support the twin pillars of Open Science [2]: transparency of methods and reproducibility of results. Scientific transparency is marked by the easily intelligible communication of what has been investigated: what were the procedures for collecting sample and the characteristics of samples collected? what kinds of measurements were made, what were the environmental conditions of the measurements? What were the analysis techniques of the collected data? Reproducibility of the results and findings from the investigation requires a high level of transparency for all but the simplest investigations; the slightest deviation in communicating and replicating complex experimental procedures or data analyses can often yield quite different data and even findings, thwarting their validation. One of the ways the NLSP is aiming to improve the communication of scientific information is through the use of ontology-driven metadata. Ontologies are powerful, graph-based knowledge representation structures, which can be leveraged to increase data interoperability, the area of the FAIR principles in which many data systems most lack compliance. Over the past decade, there has been a concerted effort in the biomedical community to develop modular and narrowly focused domain and application-specific ontologies in a common, open-source framework, the Open Biological and Biomedical Ontology (OBO) Foundry [3]. The open sharing and modular nature of this effort promises huge increases in harmonized data sharing for systems that leverage these models. Which is in line with the FAIR Data Principles of Findability, Accessibility, Interoperability, and Reuse for scientific data management and stewardship.

Life Sciences data↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

W T Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

William T. Wallace↗

Development of a Versatile Analysis Method for the Isotopic Characterization of Alpha Spectra

Over the past several years significant work has been performed at Idaho National Laboratory to build an alpha-particle spectrometry capability and expertise for a wide range of applications that include technical nuclear forensics, nuclear safeguards, and environmental monitoring. This development has led to a diverse collection of sample types and preparations measured with varied solid-state detector materials and configurations. Several characteristics of a measured alpha pulse height spectrum make performing localized fits of individual peak shapes unfeasible. Alternatively, the entirety of the spectrum must be fit concurrently to extract isotopic information. An analysis tool has been developed to perform isotopic characterization of alpha spectra. This process included a study of both the mathematical model used to represent the detector response of an alpha-particle as well as the algorithm used to fit the spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗