Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

An Overview of Behind-the-Meter Solar-Plus-Storage Regulatory Design: Approaches and Case Studies to Inform International Applications

Behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system. How should regulators, utilities, and policymakers manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV? This report is intended to offer key regulatory considerations for facilitating DPV-plus-storage programs for retail customers; relevant cases from U.S. states are provided as examples of how novel regulatory issues related to behind-the-meter energy storage systems paired with DPV are being addressed in practice. At a high level, designing a regulatory framework that aligns DPV-plus-storage deployment with larger policy objectives requires thoughtful deliberation across a range of technical and economic issues. While this report attempts to segment many of these issues into distinct topics to enhance reader understanding, in reality, DPV-plus-storage regulatory issues are all closely integrated, and design decisions on a single aspect often have broader implications. With that in mind, this report outlines a series of steps that can be employed by regulators to approach DPV-plus-storage regulatory design.

14 SOLAR ENERGY↗

Offshore Wind Farm Turbine and Energy Storage Optimization

Abstract This paper evaluates the technical and economic feasibility of repurposing decommissioned offshore oil and gas platforms as electrical substations for offshore wind projects in the U.S. Gulf of America, a region characterized by relatively low and highly variable wind speeds, extensive legacy offshore infrastructure, and exposure to merchant electricity markets. A unified techno-economic framework is developed using the Repurposing Offshore Infrastructure for Continued Energy (ROICE) Economic Model (REM) to integrate Gulfspecific wind resource assessment, commercial wind turbine performance, offshore infrastructure cost modeling, and wholesale electricity market exposure. Gulf wind speed data are vertically extrapolated to turbine hub height and combined with manufacturer power curves to compute annual energy production and capacity factors across a broad portfolio of commercial turbines, enabling identification of turbine designs best suited for low-wind offshore environments. Hourly electricity price data from the Midcontinent Independent System Operator (MISO) day-ahead market are incorporated to characterize revenue potential, price volatility, and the temporal alignment between wind generation and market conditions. In addition, a conceptual framework for offshore battery energy storage system (BESS) integration is developed to support future investigation of market-responsive energy shifting at repurposed platforms. Results from the turbine evaluation demonstrate that machines with lower cut-in wind speeds and earlier ‘rated-power’ characteristics significantly outperform larger, industry-standard offshore turbines for the same net power under Gulf wind conditions, underscoring the need for region-specific technology selection. Market analysis further reveals substantial price variability and limited intrinsic alignment between wind production and high-price periods, motivating consideration of operational flexibility mechanisms. While storage optimization is not implemented in this study, the REM framework establishes a transparent and replicable foundation for co-evaluating turbine selection, infrastructure constraints, and market exposure, providing a practical pathway for assessing the potential role of repurposed offshore platforms in enabling economically viable offshore wind development in the Gulf of America.

02 PETROLEUM↗

Aerospace Regenerative Fuel Cell Fluidic Component Design Challenges

A discrete regenerative fuel cell (RFC) system is currently under development at the NASA Glenn Research Center and Johnson Space Center. The objective of this activity is to produce an energy storage system with a higher specific energy (W·hr/kg) than the state-of-the-art battery technologies then test that system within an environment simulating the temperatures and pressures expected over a full lunar day cycle on the lunar surface. The system is designed to be as flight-like as possible given resource and commercially available technology limitations. The RFC system is comprised of a fuel cell power system, a high pressure electrolysis system, fluidic and electronic balance of plant systems, avionics, power management and distribution system, and software. This technical memorandum discusses components and subsystems that present challenges in developing flight ready RFCs. To remedy identified issues, functional application test plans are presented for components and subsystems primarily constructed with commercially available options due to the budget and schedule constraints of this ground technology demonstration project.

fuel cell↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Hybrid Fuel Cell Systems for Heavy-Duty Trucks: Configuration, Heat Rejection, and Performance

Low-temperature polymer electrolyte membrane fuel cell systems can achieve higher efficiency than diesel engines, but heat rejection remains a major challenge in class-8 heavy-duty fuel cell trucks. For the same rated power, the radiator heat load is greater than that in a diesel engine, while the allowable operating temperatures are lower. This work proposes and evaluates 400 kWe fuel cell–battery hybrid (FCH) platforms and operating strategies that manage heat rejection without enlarging the radiator frontal area. Three FCH platforms are identified, each varying in fuel cell system (FCS) rated power, battery energy storage system (ESS) capacity, and maximum stack coolant exit temperature (T h1 ). All three satisfy key system and vehicle requirements, including 175 kWe FCS power at top sustained speed, 400 kWe FCH power on a 6% grade climb, a target stack power density (PD) of 750 mW e /cm 2 , and heat rejection constraints. The first FCH has the smallest FCS, the largest ESS, and a T h1 of 90 °C. The second achieves the highest PD of 840 mW e /cm 2 at a T h1 of 95 °C. The third has the largest FCS, the smallest ESS, and a T h1 of 102 °C. At a Th1 of 115 °C, the platform can be configured as a stand-alone 400 kWe(net) FCS without hybridization, but the achievable PD drops to 460 mW e /cm 2 .

25 ENERGY STORAGE↗

NASA Redox system development project status

NASA-Redox energy storage systems developed for solar power applications and utility load leveling applications are discussed. The major objective of the project is to establish the technology readiness of Redox energy storage for transfer to industry for product development and commercialization by industry. The approach is to competitively contract to design, build, and test Redox systems progressively from preprototype to prototype multi-kW and megawatt systems and conduct supporting technology advancement tasks. The Redox electrode and membrane are fully adequate for multi-kW solar related applications and the viability of the Redox system technology as demonstrated for multi-kW solar related applications. The status of the NASA Redox Storage System Project is described along with the goals and objectives of the project elements.

Nice, A. W.↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics as an Enabler of the Current and Future Grid: Control Instead of Copper

Power electronics are becoming more pervasive in the power system. Solar, wind and battery energy storage systems regularly connect to the grid using power electronic interfaces. Loads are also increasingly power electronic-based. These changes, coupled with the change in the power system's operating characteristics as more and more renewable energy is integrated into the power system, offer a challenge to power electronic and power system engineers alike - how do we design and operate the power system moving forward?

direct connect↗

High Efficiency Reversible Solid Oxide System (Final Technical Report)

This report was generated based upon work supported by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) under the Hydrogen and Fuel Cell Technologies Office, H2@Scale Initiative, Award Number DE-EE0008847. In this project, FuelCell Energy studied the design and performance of a system rated for 15kWe Charge/3 kWe Discharge energy storage system based on reversible solid-oxide technology.

08 HYDROGEN↗

Analysis of Water Surplus at the Lunar Outpost

This paper evaluates the benefits to the lunar architecture and outpost of having a surplus of water, or a surplus of energy in the form of hydrogen and oxygen, as it has been predicted by Constellation Program's Lunar Surface System analyses. Assumptions and a scenario are presented leading to the water surplus and the revolutionary surface element options for improving the lunar exploration architecture and mission objectives. For example, some of the elements that can benefit from a water surplus are: the power system energy storage can minimize the use of battery systems by replacing batteries with higher energy density fuel cell systems; battery packs on logistics pallets can also be minimized; mobility asset power system mass can be reduced enabling more consumables and extended roving duration and distance; small robotic vehicles (hoppers) can be used to increase the science exploration range by sending round-trip robotic missions to anywhere on the Moon using in-situ produced propellants.

Santiago-Maldonado, Edgardo↗

H ∞ Control for Energy Dispatch in Autonomous Nanogrid With Communication Delays

This paper proposes an optimal controller and estimator for energy dispatch to balance the power supply and demand considering communication delays. The proposed algorithm involves modeling an autonomous nanogrid (ANG) consisting of distributed energy resources, energy storage systems, loads, an $H$ ∞ controller with a reference power modulation technique, and a state estimator. The ANG was developed to express the dynamic supply-demand energy balance of a nanogird system. Reference power modulation was designed to generate the desired ESS power based on the imbalanced energy. Random communication delays were modeled using a stochastic variable satisfying the Bernoulli random binary distribution. The optimal $H$ ∞ controller and estimator were developed using a linear matrix inequality approach to exponentially stabilize the closed-loop system. Simulations were performed using real daily demand forecasts obtained from the Korea Meteorological Administration to demonstrate the effectiveness of the proposed real-time optimization algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

H-2-SALT: Storing Fossil Energy as Hydrogen in Salt Caverns

Hydrogen storage in subsurface caverns is known as perhaps largest and longest-term energy storage system. While few such systems are currently in service (e.g., Texas; Teesside, UK), they are envisioned as being a pillar of the current energy transition that will allow intermittent power production from renewable sources (e.g., wind, solar) to be balanced with demand at grid-scale. In addition, hydrogen energy storage can allow existing fossil power plants to run more economically either by minimizing startups/shutdowns or by allowing them to take advantage of arbitrage. Finally, stored hydrogen can feed a variety of non-power users such as pipeline gas, heating, transportation, and manufacturing. The H-2-SALT paper study assessed the feasibility of a power-to-hydrogen system utilizing salt cavern storage of hydrogen in bedded salt in central Kansas, where over 750 such caverns have been constructed to date, of which approximately 350 are still in service. Legacy well and salt cavern data were collected to develop a regional geological database for two sites in Central Kansas and adjacent areas for use in more detailed geological and geomechanical site characterization efforts. This study found commercial viability and competitiveness of large-scale, electrolytic H 2 production and storage ($1.78 per kg H 2 ) that can be used for both electrical power supply to the grid during high-priced electricity periods (including co-firing with NG and fuel cell power production) and sale of H 2 for various industries, such as petrochemicals or transportation. The commercial potential of the H-2-SALT system is also relatively high because each of its components operate commercially today. It is recommended that a stratigraphic test well be drilled to collect log data and core samples that can reduce uncertainty surrounding geological and geomechanical properties of the salt beds that will be required for further cavern and energy storage system design studies.

03 NATURAL GAS↗

A 150-kW 99% Efficient All-Silicon-Carbide Triple-Active-Bridge Converter for Solar-Plus-Storage Systems

Solar-plus-storage systems could effectively mitigate the uncertainties of the photovoltaic (PV) generation and improve system reliability by adding an integrated battery energy storage system. As a three-port bidirectional isolated dc–dc converter with soft-switching capability, the triple-active-bridge (TAB) converter inherently matches the requirements of the solar-plus-storage system. However, challenges still remain in the TAB converter design to further improve system efficiency. In this article, the detailed design, implementation, and demonstration for a silicon carbide (SiC) 150-kW TAB converter are presented. Starting from a brief review of the TAB converter, the modulation scheme, power characteristics, and soft-switching region are analyzed. Then, the detailed design of the H-bridge converter building block is given. Here, to improve the system efficiency, a comprehensive characterization of the SiC gate driver with various external gate resistances is performed to address tradeoffs between switching loss and voltage overshoot during transients, as well as the thermal performance of the H-bridge building block. In addition, the design and characterization of the 20-kHz three-port transformer are also given. Comprehensive experimental studies are conducted on a full-power prototype to verify the proposed design. With a measured 99.1% peak efficiency, the proposed TAB converter can fulfill the requirements for solar-plus-storage applications.

14 SOLAR ENERGY↗

Optimal Sizing and Operation of a Hybrid Clean Energy Center

In this paper, we consider the deployment of battery energy storage systems (BESSs) paired with photovoltaics (PV) to form a hybrid clean energy center (HCEC), where the BESS is equipped for two main purposes: i) reducing the volatility of PV output and ii) shifting energy to meet an export limit. We develop a linear dynamical model to characterize the output of an HCEC and express the volatility and export power as functions of the battery's dispatch operations. We also propose an optimal sizing method via second-order cone programming (SOCP) to maximize the net benefits of the HCEC. Numerical studies are performed to illustrate and validate the proposed method.

Battery energy storage systems, photovoltaics, sec↗

Enhancing flexibility for climate change using seasonal energy storage (aquifer thermal energy storage) in distributed energy systems

Long-term energy storage is expected to play a vital role in the deep decarbonization of building energy sectors, while enhancing the flexibility of buildings to withstand future climate variations. However, it is challenging to design distributed multi-energy systems (DMES) while taking into account the uncertainties introduced by climate change, since stochastic optimization of such systems is difficult. The present study introduces a stochastic optimization model to address this bottleneck, taking into account DMES including aquifer thermal energy storage (ATES) as the long-term thermal storage. For the first time, a novel optimization algorithm links ATES with the DMES optimization model with the support of a simplified geotechnical model. Subsequently, a case study was conducted, focusing on a residential district in Chicago where the impact of future climate condition, energy demand, and solar and wind energy potentials were evaluated using Weather Research and Forecasting (WRF) data (up to 2080) and the EnergyPlus model. The study revealed that ATES is an attractive way to improve the renewable energy penetration level and minimize the dependence on fossil fuels with reasonable support from the grid to assist the fluctuations in both demand and generation. Furthermore, ATES notably reduces fuel consumption and dependence while greatly enhancing the flexibility of the energy system to withstand fluctuations in demand and renewable energy generation brought by future climate variations. These qualities will make ATES an important part of distributed energy systems, even though it is not currently the lowest cost alternative due to lack of technology maturity. Furthermore, the design platform introduced in the present study can be used to design DMES enhancing flexibility to accommodate future climate variations.

25 ENERGY STORAGE↗

Impacts of Control Set-Points on Battery Energy Storage Performance for Peak Shaving Application

This article presents the impact of battery energy storage system’s (BESS) control triggers on its performance during peak shaving application. With the increasing deployment of BESS for load leveling and grid capacity relief, the sensitivity of BESS performance to its set-points is yet to be investigated. Most utilities have defined thresholds for activating BESS control during peak demand leveling and baseload BESS charging. However, this study shows that without using optimal setpoints for control applications, the BESS can be under-utilized. Simulations results of the peak shaving algorithm implementation in 30-minute time step over a period of 10 years show the impact of different set-points on distribution transformer loading, line and system losses.

battery energy storage system↗