Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Synthesis of SrO(SrTiO{sub 3}){sub n} (n = 1, 2, {infinity}) compounds and electronic structure analysis

SrO(SrTiO{sub 3}){sub n} compounds were prepared by a modified sol-gel self-propagating combustion, which is a low-temperature combustion synthesis procedure using microwave-assisted sol-gel as precursors. The thermal treating conditions were determined by DTA/TG analysis of the powders. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used for the sample characterization. The results confirm that the high temperature and long reaction time which occur in classical solid-state reaction method are avoided. The band structure, total density of states (DOS), and partial density of states (PDOS) of SrO(SrTiO{sub 3}){sub n} were calculated in order to study the electronic structures of SrO(SrTiO{sub 3}){sub n}.

36 MATERIALS SCIENCE↗

Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection

As x-ray and electron tomography is pushed farther into the nanoscale, the limitations of rotation stages become more apparent leading to challenges in the alignment of the acquired projection images. Here we present an approach for rapid post-acquisition alignment of these projections to obtain high quality 3D images. Our approach is based on a joint estimation of alignment errors, and the object, using an iterative refinement procedure. We characterize convergence in simulations, and show its application in x-ray and electron nanotomography.

47 OTHER INSTRUMENTATION↗

Electron mobility and free-carrier absorption in GaAs - Determination of the compensation ratio

Theoretical calculations of electron mobility and free-carrier absorption in n-type GaAs at room temperature were carried out taking into consideration all major scattering processes. It was found that satisfactory agreement between theoretical and experimental results on free-carrier absorption is obtained only when the effect of compensation is quantitatively taken into account. In conjunction with experimental studies it is shown that the electron mobility (for n greater than 10 to the 15th per cu cm) and free-carrier absorption (for n greater than 10 to the 16th per cu cm) are sufficiently sensitive to the ionized impurity concentration to provide a reliable means for determining the compensation ratio. Convenient procedures are presented for the determination of the compensation ratio from the free-carrier absorption coefficient and from the computed values of room-temperature electron mobility. Values of the compensation ratio obtained by these two procedures are in good agreement provided the carrier-concentration variations in the material are not appreciably greater than 10%.

Walukiewicz, W.↗

Investigating the use of in situ liquid cell scanning transmission electron microscopy

Engineering nanoparticles with desired shape-dependent properties is the key to many applications in nanotechnology. Although many synthetic procedures exist to produce anisotropic gold nanoparticles, the dynamics of growth are typically unknown or hypothetical. In the case of seed-mediated growth in the presence of DNA into anisotropic nanoparticles, it is not known exactly how DNA directs growth into specific morphologies. A series of preliminary experiments were carried out to contribute to the investigation of the possible mechanism of DNA-mediated growth of gold nanoprisms into gold nanostars using liquid cell scanning transmission electron microscopy (STEM). Imaging in the liquid phase was achieved through the use of a liquid cell platform and liquid cell holder that allow the sample to be contained within a “chip sandwich” between two electron transparent windows. Ex situ growth experiments were performed using Au-T30 NPrisms (30-base thymine oligonucleotide-coated gold nanoprisms) that are expected to grow into gold nanostars. Growth to form these nanostars were imaged using TEM (transmission electron microscopy) and liquid cell STEM (scanning transmission electron microscopy). An attempt to perform in situ growth experiments with the same Au-T30 nanoprisms revealed challenges in obtaining desired morphology results due to the environmental differences within the liquid cell compared to the ex situ environment. Different parameters in the experimental method were explored including fluid line set up, simultaneous and alternating reagent addition, and the effect of different liquid cell volumes to ensure adequate flow of reagents into the liquid cell. Lastly, the binding affinities were compared for T30 and A30 DNA incubated with gold nanoparticles using zeta potential measurements, absorption spectroscopy, and isothermal titration calorimetry (ITC). It was previously reported thymine bases have a lower binding affinity to gold surfaces than adenine bases. However, the results reported here contradict the previously reported data. Future prospectives on this work are outlined.

36 MATERIALS SCIENCE↗

Room temperature plasma-etching and surface passivation of far-ultraviolet Al mirrors using electron beam generated plasmas

The development of optical systems operating in the far ultraviolet range (FUV, λ=100-200 nm) is limited by the efficiency of passivated aluminum (Al) mirrors. Although it is presently possible to obtain high-reflectivity FUV mirrors through physical vapor deposition, the process involves deposition with substrates at high temperatures, which is technically challenging for large optical elements. A novel passivation procedure for bare Al mirrors is reported. The treatment consisted of using a low-temperature electron-beam generated plasma produced in a gas mixture of Ar and SF6 to etch away the native oxide layer from the Al film, while simultaneously promoting the generation of a thin aluminum tri-fluoride (AlF3) layer on the Al surface. In the first section we analyze the effect of varying both ion energy and SF6 concentration on the FUV reflectance, thickness, composition, and surface morphology of the resulting AlF3 protective layers. In the second section, the reflectivity of samples is optimized at selected important FUV wavelengths for astronomical observations. Notably, samples attained state-of-the-art reflectances of 75% at 108.5 nm (He Lyman γ), 91% at 121.6 nm (H Lyman α), 90% at 130.4 nm (OI), and of 95% at 155.0 nm (C IV). The stability over time of these passivated mirrors is also investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic structure calculation of vanadium-and scandium-based endohedral fullerenes VSc 2 N@C 2 n (2 n = 70, 76, 78, 80)

We present candidate structures for the most stable isomers for the VSc 2 N@C 70 , VSc 2 N@C 76 , VSc 2 N@C 78 , and VSc 2 N@C 80 using a systematic procedure that involves all possible isomers of the host fullerene cages. Subsequently, a detailed investigation of structural and electronic properties of the lowest energy isomers is performed using density functional theory in combination with large polarized Gaussian basis sets. The search correctly identifies the experimentally observed VSc 2 N@C 80 isomer as the most stable structure. The structural analysis shows that onlyVSc 2 N@C 70 has a non-IPR cage among the four endohedral fullerenes. Respectively, VSc 2 N@C 70 and VSc 2 N@C 76 have nearly degenerate spin states with total spin S=0 and S=1. All the lowest energy cages are energetically stable and show significant electron accepting capacity comparable to C 60 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ controlled heteroepitaxy of single-domain GaP on As-modified Si(100)

Metalorganic vapor phase epitaxy of III-V compounds commonly involves arsenic. We study the formation of atomically well-ordered, As-modified Si(100) surfaces and subsequent growth of GaP/Si(100) quasisubstrates in situ with reflection anisotropy spectroscopy. Surface symmetry and chemical composition are measured by low energy electron diffraction and X-ray photoelectron spectroscopy, respectively. A two-step annealing procedure of initially monohydride-terminated, (1 × 2) reconstructed Si(100) in As leads to a predominantly (1 × 2) reconstructed surface. GaP nucleation succeeds analogously to As-free systems and epilayers free of antiphase disorder may be grown subsequently. The GaP sublattice orientation, however, is inverted with respect to GaP growth on monohydride-terminated Si(100)

36 MATERIALS SCIENCE↗

Equivalent electron fluence for space qualification of shallow junction heteroface GaAs solar cells

It is desirable to perform qualification tests prior to deployment of solar cells in space power applications. Such test procedures are complicated by the complex mixture of differing radiation components in space which are difficult to simulate in ground test facilities. Although it has been shown that an equivalent electron fluence ratio cannot be uniquely defined for monoenergetic proton exposure of GaAs shallow junction cells, an equivalent electron fluence test can be defined for common spectral components of protons found in space. Equivalent electron fluence levels for the geosynchronous environment are presented.

Wilson, J. W.↗

Release of microorganisms from soil with respect to transmission electron microscopy viewing and plate counts

A study was conducted to obtain information concerning the fate of soil microorganisms during the procedures normally used in separating them from the soil in connection with various types of investigations. A silty clay loam (pH 6.0, moisture content 25%, organic content 3.5%) was used in the study. The results of the study indicate that many of the microbial cells naturally residing in soil remain attached to or, for some other reason, are not separated from the soil debris despite the use of various combinations of blending, sonication, and chemical dispersing agents. The method B used by Balkwill et al. (1975) provides a reasonable electron microscopy evaluation of the soil microflora.

Balkwill, D. L.↗

Control of the Lasing Slice by Transverse Mismatch in an X-Ray Free-Electron Laser

We demonstrated selective slice-dependent lasing by controlling the matching to the undulator of different slices within an electron bunch. The slice-dependent mismatch was realized through quadrupole wakefield generated in a corrugated structure. A deterministic procedure based on empirical beam transport and phase space information is used to match selected slices by turns to lase in the undulator while keeping all other slices from lasing, thus staying fresh. Measurements of time-resolved electron bunch energy loss by a transverse deflecting cavity confirmed the predicted behavior.

43 PARTICLE ACCELERATORS↗

Patterning approach for detecting defect in device manufacturing

Compact handheld devices which were a dream in the past are now a reality; this has been enabled by miniaturization of circuit architectures including power devices. Scaling down of the design feature sizes does come with a price with an increase in systematic defects during chip manufacturing. There are generally two methods of inline defect detection adopted to monitor the semiconductor device fabrication—optical inspection and electron beam inspection. The optical inspection uses ultra-violet and deep ultra-violet (UV/DUV) light to find patterning defects on the wafer. While the electron-beam inspection uses electron charge and discharge measurement to find electrical connection defects, both are a costly procedure in terms of resources and time. The physical limit of feature resolution of the optical source is now making the defect inspection job difficult in miniaturized application specific integrated circuit (ASIC). This study is designed to test the patterning optimization approach on both inspection platforms. Using hotspot analysis weak locations are identified in the full chip design, and then they are verified in the inline wafer inspection. The criterion for hot-spot determination is also discussed in this paper.

36 MATERIALS SCIENCE↗

Experimentally inferred thermal diffusivities in the edge pedestal between edge-localized modes in DIII-D

Using temperature and density profiles averaged over the same subinterval of several successive inter-edge-localized-mode (ELM) periods, the ion and electron thermal diffusivities in the edge pedestal were inferred between ELMs for two DIII-D [J. Luxon, Nucl. Fusion 42, 614 (2002)] discharges. The inference procedure took into account the effects of plasma reheating and density buildup between ELMs, radiation and atomic physics cooling, neutral beam heating and ion-electron equilibration, and recycling neutral and beam ionization particle sources in determining the conductive heat flux profiles used to infer the thermal diffusivities in the edge pedestal. Comparison of the inferred thermal diffusivities with theoretical formulas based on various transport mechanisms was inconclusive insofar as identifying likely transport mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full Inversion of Solar Relativistic Electron Events Measured by the Helios Spacecraft

The Parker Solar Probe and the incoming Solar Orbiter mission will provide measurements of solar energetic particle (SEP) events at close heliocentric distances from the Sun. Up to present, the largest data set of SEP events in the inner heliosphere are the observations by the two Helios spacecraft. Aims.We re-visit a sample of 15 solar relativistic electron events measured by the Helios mission with the goal of better characterizing the injection histories of solar energetic particles and their interplanetary transport conditions at heliocentric distances <1AU. Methods. The measurements provided by the E6 instrument on board Helios provide us with the electron directional distributionsin eight di erent sectors that we use to infer the detailed evolution of the electron pitch-angle distributions. The results of a Monte Carlo interplanetary transport model, combined with a full inversion procedure, were used to fit the observed directional intensities in the 300–800 keV nominal energy channel. Unlike previous studies, we have considered both the energy and angular responses of the detector. This method allowed us to infer the electron release time profile at the source and determine the electron interplanetary transport conditions. Results. We discuss the duration of the release time profiles and the values of the radial mean free path, and compare them with thevalues reported previously in the literature using earlier approaches. Five of the events show short injection histories (<30 min) at the Sun and ten events show long-lasting (>30 min) injections. The values of mean free path range from 0.02AU to 0.27AU.Conclusions. The inferred injection histories match with the radio and soft X-ray emissions found in literature.We find no dependence of the radial mean free path on the radial distance. In addition, we find no apparent relation between the strength of interplanetary scattering and the size of the solar particle release.

Pacheco, D.↗

Use of the drift-time method to measure the electron lifetime in long-drift-length CdZnTe detectors

The traditional method for electron lifetime measurements of CdZnTe (CZT) detectors relies on using the Hecht equation. The procedure involves measuring the dependence of the detector response on the applied bias to evaluate the μτ product, which in turn can be converted into the carrier lifetime. Despite general acceptance of this technique, which is very convenient for comparative testing of different CZT materials, the assumption of a constant electric field inside a detector is unjustified. In the Hecht equation, this assumption means that the drift time would be a linear function of the distance. This condition is not fulfilled in practice at low applied biases, where the Hecht equation is most sensitive to the μτ product. As a result, researchers usually take measurements at relatively high biases, which work well in the case of the low μτ-product material, <10 -3 cm 2 /V, but give significantly underestimated values for the case of high μτ-product crystals. In this paper, we applied the drift-time method to measure the electron lifetimes in long-drift-length (4 cm) standard-grade CZT detectors produced by the Redlen Technologies. We found that the electron μτ product of tested crystals is in the range 0.1–0.2 cm 2 /V, which is an order of the magnitude higher than any value previously reported for a CZT material. Finally, in comparison, using the Hecht equation fitting, we obtained μτ = 2.3 × 10 -2 cm 2 /V for a 2-mm thin planar detector fabricated from the same CZT material.

47 OTHER INSTRUMENTATION↗

Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe

This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.

36 MATERIALS SCIENCE↗

Overall Traveling-Wave-Tube Efficiency Improved By Optimized Multistage Depressed Collector Design

Depressed Collector Design The microwave traveling wave tube (TWT) is used widely for space communications and high-power airborne transmitting sources. One of the most important features in designing a TWT is overall efficiency. Yet, overall TWT efficiency is strongly dependent on the efficiency of the electron beam collector, particularly for high values of collector efficiency. For these reasons, the NASA Glenn Research Center developed an optimization algorithm based on simulated annealing to quickly design highly efficient multistage depressed collectors (MDC's). Simulated annealing is a strategy for solving highly nonlinear combinatorial optimization problems. Its major advantage over other methods is its ability to avoid becoming trapped in local minima. Simulated annealing is based on an analogy to statistical thermodynamics, specifically the physical process of annealing: heating a material to a temperature that permits many atomic rearrangements and then cooling it carefully and slowly, until it freezes into a strong, minimum-energy crystalline structure. This minimum energy crystal corresponds to the optimal solution of a mathematical optimization problem. The TWT used as a baseline for optimization was the 32-GHz, 10-W, helical TWT developed for the Cassini mission to Saturn. The method of collector analysis and design used was a 2-1/2-dimensional computational procedure that employs two types of codes, a large signal analysis code and an electron trajectory code. The large signal analysis code produces the spatial, energetic, and temporal distributions of the spent beam entering the MDC. An electron trajectory code uses the resultant data to perform the actual collector analysis. The MDC was optimized for maximum MDC efficiency and minimum final kinetic energy of all collected electrons (to reduce heat transfer). The preceding figure shows the geometric and electrical configuration of an optimized collector with an efficiency of 93.8 percent. The results show the improvement in collector efficiency from 89.7 to 93.8 percent, resulting in an increase of three overall efficiency points. In addition, the time to design a highly efficient MDC was reduced from a month to a few days. All work was done in-house at Glenn for the High Rate Data Delivery Program. Future plans include optimizing the MDC and TWT interaction circuit in tandem to further improve overall TWT efficiency.

Vaden, Karl R.↗