Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The relation of motion sickness to the spatial-temporal properties of velocity storage

Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.

NASA Discipline Neuroscience↗

Cross-axis adaptation of torsional components in the yaw-axis vestibulo-ocular reflex

The three pairs of semicircular canals within the labyrinth are not perfectly aligned with the pulling directions of the six extraocular muscles. Therefore, for a given head movement, the vestibulo-ocular reflex (VOR) depends upon central neural mechanisms that couple the canals to the muscles with the appropriate functional gains in order to generate a response that rotates the eye the correct amount and around the correct axis. A consequence of these neural connections is a cross-axis adaptive capability, which can be stimulated experimentally when head rotation is around one axis and visual motion about another. From this visual-vestibular conflict the brain infers that the slow-phase eye movement is rotating around the wrong axis. We explored the capability of human cross-axis adaptation, using a short-term training paradigm, to determine if torsional eye movements could be elicited by yaw (horizontal) head rotation (where torsion is normally inappropriate). We applied yaw sinusoidal head rotation (+/-10 degrees, 0.33 Hz) and measured eye movement responses in the dark, and before and after adaptation. The adaptation paradigm lasted 45-60 min, and consisted of the identical head motion, coupled with a moving visual scene that required one of several types of eye movements: (1) torsion alone (-Roll); (2) horizontal/torsional, head right/CW torsion (Yaw-Roll); (3) horizontal/torsional, head right/CCW torsion (Yaw+Roll); (4) horizontal, vertical, torsional combined (Yaw+Pitch-Roll); and (5) horizontal and vertical together (Yaw+Pitch). The largest and most significant changes in torsional amplitude occurred in the Yaw-Roll and Yaw+Roll conditions. We conclude that short-term, cross-axis adaptation of torsion is possible but constrained by the complexity of the adaptation task: smaller torsional components are produced if more than one cross-coupling component is required. In contrast, vertical cross-axis components can be easily trained to occur with yaw head movements.

Non-NASA Center↗

The human vestibulo-ocular reflex during linear locomotion

During locomotion, there is a translation and compensatory rotation of the head in both the vertical and horizontal planes. During moderate to fast walking (100 m/min), vertical head translation occurs at the frequency of stepping (2 Hz) and generates peak linear acceleration of 0.37 g. Lateral head translation occurs at the stride frequency (1 Hz) and generates peak linear acceleration of 0.1 g. Peak head pitch and yaw angular velocities are approximately 17 degrees/s. The frequency and magnitude of these head movements are within the operational range of both the linear and angular vestibulo-ocular reflex (IVOR and aVOR). Vertical eye movements undergo a phase reversal from near to far targets. When viewing a far (>1 m) target, vertical eye velocity is typical of an aVOR response; that is, it is compensatory for head pitch. At close viewing distances (<1 m), vertical eye velocity is in phase with head pitch and is compensatory for vertical head translation, suggesting that the IVOR predominantly generates the eye movement response. Horizontal head movements during locomotion occur at the stride frequency of 1 Hz, where the IVOR gain is low. Horizontal eye movements are compensatory for head yaw at all viewing distances and are likely generated by the aVOR.

NASA Discipline Neuroscience↗

Primate translational vestibuloocular reflexes. I. High-frequency dynamics and three-dimensional properties during lateral motion

The dynamics and three-dimensional (3-D) properties of the primate translational vestibuloocular reflex (trVOR) for high-frequency (4-12 Hz, +/-0.3-0.4 g) lateral motion were investigated during near-target viewing at center and eccentric targets. Horizontal response gains increased with frequency and depended on target eccentricity. The larger the horizontal and vertical target eccentricity, the steeper the dependence of horizontal response gain on frequency. In addition to horizontal eye movements, robust torsional response components also were present at all frequencies. During center-target fixation, torsional response phase was opposite (anticompensatory) to that expected for an "apparent" tilt response. Instead torsional response components depended systematically on vertical-target eccentricity, increasing in amplitude when looking down and reversing phase when looking up. As a result the trVOR eye velocity vector systematically tilted away from a purely horizontal direction, through an angle that increased with vertical eccentricity with a slope of approximately 0.7. This systematic dependence of torsional eye velocity tilt on vertical eye position suggests that the trVOR might follow the 3-D kinematic requirements that have been shown to govern visually guided eye movements and near-target fixation.

NASA Discipline Neuroscience↗

Dynamic properties of the human vestibulo-ocular reflex during head rotations in roll

We investigated the dynamic properties of the human vestibulo-ocular reflex (VOR) during roll head rotations in three human subjects using the magnetic search coil technique. In the first of two experiments, we quantify the behavior of the ocular motor plant in the torsional plane. The subject's eye was mechanically displaced into intorsion, extorsion or abduction, and the dynamic course of return of the eye to its resting position was measured. The mean predominant time constants of return were 210 msec from intorsion, 83 msec from extorsion, and 217 msec from abduction, although there was considerable variability of results from different trials and subjects. In the second experiment, we quantify the efficacy of velocity-to-position integration of the vestibular signal. Position-step stimuli were used to test the torsional or horizontal VOR, being applied with subjects heads erect or supine. After a torsional position-step, the eye drifted back to its resting position, but after a horizontal position-step the eye held its new horizontal position. To interpret these responses we used a simple model of the VOR with parameters of the ocular motor plant set to values determined during Exp 1. The time constant of the velocity-to-position neural integrator was smaller (typically 2 sec) in the torsional plane than in the horizontal plane (> 20 sec). No disconjugacy of torsional eye movements was observed. Thus, the dynamic properties of the VOR in roll differ significantly from those of the VOR in yaw, reflecting different visual demands placed on this reflex in these two planes.

NASA Discipline Neuroscience↗

System identification of perilymphatic fistula in an animal model

An acute animal model has been developed in the chinchilla for the study of perilymphatic fistulas. Micropunctures were made in three sites to simulate bony, round window, and oval window fistulas. The eye movements in response to pressure applied to the external auditory canal were recorded after micropuncture induction and in preoperative controls. The main pressure stimulus was a pseudorandom binary sequence (PRBS) that rapidly changed between plus and minus 200 mm of water. The PRBS stimulus, with its wide frequency bandwidth, produced responses clearly above the preoperative baseline in 78 percent of the runs. The response was better between 0.5 and 3.3 Hz than it was below 0.5 Hz. The direction of horizontal eye movement was toward the side of the fistula with positive pressure applied in 92 percent of the runs. Vertical eye movements were also observed. The ratio of vertical eye displacement to horizontal eye displacement depended upon the site of the micropuncture induction. Thus, such a ratio measurement may be clinically useful in the noninvasive localization of perilymphatic fistulas in humans.

Non-NASA Center↗

Ocular examination for trauma; clinical ultrasound aboard the International Space Station

BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

Clinical Trial↗

Irradiation of rainbow trout at early life stages results in a proteomic legacy in adult gills. Part A; proteomic responses in the irradiated fish and in non-irradiated bystander fish

Highlights: • The effects of early life irradiation on the trout gill proteome was investigated. • The bystander effect proteomic responses in non-irradiated fish were investigated. • Proteomic responses of embryonic irradiation were anti-tumorigenic or anti-oxidant. • Proteomic responses of larval or first feeder irradiation were “dual function”. • Bystander effect proteomic responses were anti-tumorigenic or protective. Exposure to a single 0.5 Gy X-ray dose of eggs at 48 h after fertilisation (48 h egg), eyed eggs, yolk sac larvae (YSL) and first feeders induces a legacy effect in adult rainbow trout. This includes the transmission of a bystander effect to non-irradiated adult trout which had swam with the irradiated fish. The aim of this study was to investigate this legacy by analysing the gill proteome of these irradiated and bystander fish. Irradiation at all of the early life stages resulted in changes to proteins which play a key role in development but are also known to be anti-tumorigenic and anti-oxidant: upregulation of haemoglobin subunit beta (48 h egg), haemoglobin, serum albumin 1 precursor (eyed eggs), clathrin heavy chain 1 isoform X10 (eyed eggs and first feeders), and actin-related protein 2/3 complex subunit 4 (first feeders), downregulation of pyruvate dehydrogenase, histone 1 (48 h egg), triosephosphate isomerase (TPI), collagen alpha-1(1) chain like proteins (YSL), pyruvate kinase PKM-like protein (YSL and first feeders), ubiquitin-40S ribosomal proteins S27 and eukaryotic translation initiation factor 4 A isoform 1B (first feeders). However irradiation of YSL and first feeders (post hatching early life stages) also induced proteomic changes which have a complex relationship with tumorigenesis or cancer progression; downregulation of alpha-1-antiprotease-like protein precursor, vigilin isoform X2 and nucleoside diphosphate kinase (YSL) and upregulation of hyperosmotic glycine rich protein (first feeders). In bystander fish some proteomic changes were similar to those induced by irradiation: upregulation of haemoglobin subunit beta (48 h egg), haemoglobin (eyed eggs), actin-related protein 2/3 complex subunit 4, hyperosmotic glycine rich protein (first feeders), and downregulation of alpha-1-antiprotease-like protein, vigilin isoform X2, nucleoside diphosphate kinase (YSL), pyruvate kinase PKM-like protein and ubiquitin-40S ribosomal protein S27a-like (first feeders). Other proteomic changes were unique to bystander fish; downregulation of TPI, ubiquitin-40S ribosomal protein S2 (eyed egg), cofilin-2, cold-inducible RNA-binding protein B-like isoform X3 (YSL) and superoxide dismutase (first feeder), and upregulation of haemoglobin subunit alpha, collagen 1a1 precursor, apolipoprotein A-1-1 and A-1–2 precursor (first feeders). These bystander effect proteomic changes have been shown to be overwhelmingly anti-tumorigenic or protective of the fish gill.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Metallurgical characterization of brass objects from the Akko 1 shipwreck, Israel

The Akko 1 shipwreck was a small Egyptian armed vessel or auxiliary naval brig built in the eastern Mediterranean at the beginning of the 19th century. During the underwater excavations, about 230 brass hook-and-eye closures were found, mainly in the bow area. In addition, 158 brass cases were found, mainly between midships and the aft extremity of the shipwreck. Metallurgical non-destructive and destructive characterizations of selected items were performed, including radiographic testing, XRF, lead isotope analysis, optical microscopy, SEM–EDS and microhardness tests. The hook-and-eye closures and the cases were both found to be made of binary copper–zinc alloy (about 30 wt.% zinc). While the brass cases were made from rolled sheets, hand-made using simple tools, and joined by tin–lead soldering material, the brass hook-and-eye closures were hand-made from drawn brass wire, and manufactured from commercial drawn brass bars by a cold-working process. The lead isotope analyses suggest different provenances of the raw materials used for making the brass objects, thus the different origins of the ores may hint that the brass wire and sheet were imported to the workshops in which the objects were manufactured. - Highlights: • Brass cases and hook-and-eye closures were retrieved from the Akko 1 shipwreck. • Both types of objects were made of binary copper–zinc alloy (about 30 wt.% zinc). • The cases were hand-made from rolled sheets and joined by tin–lead soldering. • Hook-and-eye closures were made from drawn brass wire manufactured by cold-working. • Lead isotope analyses suggest that the origins of the raw material were diverse.

36 MATERIALS SCIENCE↗

Daylight-Mediated, Passive, and Sustained Release of the Glaucoma Drug Timolol from a Contact Lens

Timolol, a potent inhibitor of β-adrenergic receptors (βARs), is a first-line drug for decreasing the intraocular pressure (IOP) of patients with glaucoma. Timolol is administered using 0.5% eye-drop solutions at >3 × 10 7 times the inhibitory concentration ( k i ) for βARs. This high dose is wasteful and triggers off-target effects that increase medication noncompliance. Here, we introduce contact lenses that release timolol to the eye throughout the day during passive exposures to natural daylight at a more therapeutically relevant concentration (>3000 k i ). Timolol is coupled to the polymer of the contact lens via a photocleavable caged cross-linker and is released exclusively to the surrounding fluid after the 400-430 nm mediated cleavage of the cross-linking group. Studies conducted in a preclinical mouse model of glaucoma show photoreleased timolol is effective as authentic timolol in reducing IOP. Our studies highlight several advantages of daylight-mediated release of timolol from lenses compared to eye-drops. First, fitted contact lenses exposed to natural daylight release sufficient timolol to sustain the inhibition of βARs over a 10 h period. Second, the contact lenses inhibit βARs in the eye using only 5.7% of the timolol within a single eye-drop. Third, the lenses allow the patient to passively control the amount of timolol released from the lens-for example, early morning exposure to outdoor sunlight would release enough timolol to maximally reduce the IOP, whereas subsequent periodic exposures to indoor daylight would release sufficient timolol to overcome the effects of its spontaneous dissociation from βARs. Fourth, our lenses are disposable, designed for single day use, and manufactured at a low cost.

60 APPLIED LIFE SCIENCES↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Impact of Corneal Refraction and Iris Tissue Non-planarity on Iris Recognition

Assumptions regarding eye morphology are implicit in iris recognition algorithms. The cornea is assumed to have little to no effect on the view of the iris texture when the eye gaze is non-frontal, the iris is assumed flat, and the eye is assumed to be imaged via an orthographic projection. If these assumptions hold, affine transformations may be used to rectify non-frontally posed images to a frontal view and the rubber sheet model may be accurately used to normalize the iris annulus to a rectangular image. This work examines how iris recognition performance degrades when the first two assumptions are violated. Using a computer renderable eye model, a data set is created varying the presence of the cornea and a parameterized non-planarity of the iris shape across a large range of eye gaze angles. Matching scores are created using a commercial matcher. Thus, when comparing the relative impact of each assumption violation, it is observed that iris non-planarity presents a more significant problem than corneal refractive distortion with regard to iris recognition accuracy in non-frontal images.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Laser Incident Lessons Learned and Action List

On Thursday November 19, 2015, LANL postdoc received an eye injury from a reflected, nonvisible laser beam (Class 4, pulsed, wavelength 800 nanometer). The setup is configured to split the laser output into two work areas in which qualified operators conduct research experiments. During this incident, the laser output beam was being projected to both experimental work areas, although only one experimental area was actively being used. The second laser beam directed to the second work area was blocked by an inappropriate device (Plexiglas, reflective, non-normal incidence) that reflected substantial portion of the beam toward the first setup. In preparation for the measurements, worker stepped on the stepstool and decided to remove the laser goggles to better see the micrometer readings which were difficult to see due to insufficient lighting. Immediately, he noticed a flash of light in his eye. The operator quickly replaced the laser eye-wear and then, using an infrared viewer, located a stray laser beam being reflected from the plexiglas beam block. The operator did not think he had sustained any injury and continued working. Later that day, however, he noticed a blurry spot in the vision of his left eye. He notified his supervisor on Friday morning, November 20, 2015, and was taken by CINT management to Sandia National Laboratories (SNL) medical facility for evaluation. SNL Medical did not find any abnormalities, but referred the operator to a local ophthalmologist for further evaluation. Further evaluations by the ophthalmologist on November 21 and November 23 identified a small spot of inflammation near the fovea on the retina in his left eye. The ophthalmologist stated that this spot would most likely heal on its own and that the blurry spot on the operator's vision would go away. A follow-up visit was scheduled. The employee was released back to work without restrictions.

99 GENERAL AND MISCELLANEOUS↗

Experimental study of visual accommodation

A summary report of a research effort related to the human visual accommodation system is presented. A theoretical study of the accommodation system was made. Subsequent effort was aimed at the development of specialized instrumentation for experiments designed to lead to understanding the nature of the control system in human accommodation. The necessary instrumentation consisted primarily of: (1) an automatic optometer to measure the state of eye focus, (2) a focus stimulator device to control the apparent optical distance to any target, and (3) a two-dimensional eye tracker. The concepts and designs of the first two instruments have been published in the open literature, but this report contains the first detailed treatment of the Purkinje eye tracker developed under this program. The report also discusses an accommodation lag model to explain the ability of the eye to apparently know the polarity of focus error even though the blur on the retina is to a first-approximation an even function. The interaction of the accommodation and eye movement systems is also discussed, as is the ability to train the visual accommodation system to a surprisingly responsive condition in only a few hours of training.

Cornsweet, T. N.↗

Vestibular function in the space environment

The present work presents new results about the interdependence of optical illusory sensations and eye movements in man. To establish to what degree certain illusions previously obtained during centrifugation and parabolic flight can be explained by eye movements and by neuronal integration in the brain, real eye movements were measured as they occurred in the dark without optical fixation, during rectilinear accelerations on the ground, and during weightlessness in parabolic flight. Results provide valuable insight into normal vestibular function as well as resolution of within-the-eye and behind-the-eye contributions to the above illusions.

Von Baumgarten, R. J.↗

Intra-ocular pressure normalization technique and equipment

A method and apparatus for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval is presented. This allows maintenance of normal intraocular pressure during glaucoma surgery. According to the invention, a pressure regulator of the spring biased diaphragm type is provided with additional bias by a column of liquid. The height of the column of liquid is selected such that the pressure at a hypodermic needle connected to the output of the pressure regulator is equal to the measured pressure of the eye. The hypodermic needle can then be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle. Alternately, a second hypodermic needle may be inserted into the eye to provide a controlled leak off path for excessive pressure and clouded fluid from the anterior chamber.

Mcgannon, W. J.↗