Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY CONSERVATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since 2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL) conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State. This report describes the analysis methodology, explains detailed specifications of the EEMs, and summarizes the results of individual EEMs and EEM bundles by building type and climate zone. As shown in Figure ES.1, significant energy saving could be achieved by adopting the NYStretch-Energy Code 2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DSN energy data base preliminary design

The design and implementation of a computerized data base created to support the DSN Energy Conservation Project with data relating to energy use at Goldstone Deep Space Communications Complex are described. The results of development work to date, are presented along with work currently in progress or in the planning stage.

Cole, E. R.↗

High-Temperature, Wirebondless, Ultracompact Wide Bandgap Power Semiconductor Modules

Silicon carbide (SiC) and other wide bandgap semiconductors offer great promise of high power rating, high operating temperature, simple thermal management, and ultrahigh power density for both space and commercial power electronic systems. However, this great potential is seriously limited by the lack of reliable high-temperature device packaging technology. This Phase II project developed an ultracompact hybrid power module packaging technology based on the use of double lead frames and direct lead frame-to-chip transient liquid phase (TLP) bonding that allows device operation up to 450 degC. The new power module will have a very small form factor with 3-5X reduction in size and weight from the prior art, and it will be capable of operating from 450 degC to -125 degC. This technology will have a profound impact on power electronics and energy conversion technologies and help to conserve energy and the environment as well as reduce the nation's dependence on fossil fuels.

Elmes, John↗

Numerical Modeling of Boiling in a Heated Tube

This paper presents numerical models of boiling in a heated tube using the Generalized Fluid System Simulation Program (GFSSP), a finite-volume-based general-purpose flow network code developed at NASA/Marshall Space Flight Center. The heated tube is discretized into a one-dimensional array of nodes and branches to represent the flow of liquid and vapor in a tube with a prescribed pressure differential. The solid wall is also discretized into solid nodes and conductors to allow for heat transfer between the wall and the fluid. The conservation equations of mass, momentum, and energy of the fluid are solved simultaneously with the energy conservation equation for the solid wall. Two experimental configurations of fluid flowing in a vertical tube have been simulated, one with water and the other with liquid hydrogen. This paper compares experimental data with numerical predictions based on four different published correlations for boiling heat transfer coefficients. Three of these correlations are applicable to the saturated vertical flow conditions of the experiments. One of them is applicable to film boiling and has been used for the liquid hydrogen experiment, which was in film boiling regime. For the case of boiling water, the predictions of wall temperatures using the boiling heat transfer correlations agreed well with the experimental results. However, in the case of boiling hydrogen larger discrepancies were observed between the experimental data and numerical predictions.

Majumdar, Alok↗

Existing Whole-House Solutions Case Study: Community-Scale Energy Modeling - Southeastern United States

Community-scale energy modeling and testing are useful for determining energy conservation measures that will effectively reduce energy use. To that end, IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all-electric, production-built homes was modeled. The homes were in two communities: one built in the 1970s and the other in the mid-2000s.

ASHRAE GUIDELINE 14↗

Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes

This study used EnergyPlus to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate; the study confirmed that supplemental dehumidification should be provided to maintain space relative humidity below 60% in a hot-humid climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Evaluating Cost-effectiveness of Commercial Energy Code Changes

This document lays out the U.S. Department of Energy’s (DOE’s) method for evaluating the cost-effectiveness of energy code proposals and editions. The evaluation is applied to provisions or editions of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 90.1 and the International Energy Conservation Code (IECC). The method follows standard life-cycle cost (LCC) economic analysis procedures. Cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes, 2) evaluating the incremental and replacement costs related to the changes, and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of Existing OpenStudio Measures: Reviews, Interviews, and Future Developments

OpenStudio Measure development is continuously in progress and greatly propelled by the collaborative efforts within the building energy modeling community. To ensure the widespread adoption and benefit of OpenStudio Measures, developers must understand the current status of Measure development and the needs of OpenStudio Measure users. The first step involves a comprehensive review of existing content to prevent redundancy and gain insights into how OpenStudio Measures are used in the building energy modeling community. This knowledge can then be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users can be leveraged to shape future Measures. Numerous OpenStudio Measures have been created and shared on the Building Component Library (BCL). The BCL is an open-source repository housing various OpenStudio-related resources, including building component blocks, descriptive metadata, and Measures describing modifications to building energy models. The OpenStudio Measures in BCL encompass a wide range of energy conservation Measures from basic lighting power reduction to complex HVAC model transformation. They also enable users to generate customized reports and facilitate the integration of energy simulation with other analytical processes. This report presents review of 272 currently available OpenStudio Measures in BCL. The OpenStudio Measures were reviewed by category and subcategory. These Measures are summarized by their functionalities and keywords. To gain insights into how OpenStudio Measures are used in building energy modeling community, interviews were conducted. A total of 12 interview responses were collected from 6 individuals in the industry and 6 individuals in academia. The knowledge acquired from reviewing the existing Measures and interview results will be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users will be leveraged to shape future Measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of the Residential Provisions of the 2015 IECC

This analysis focuses on one- and two-family dwellings, townhomes, and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). PNNL evaluated the cost-effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2015 edition of the IECC, hereafter referred to as the 2015 IECC, compared to those in the 2012 and 2009 IECC. The current analysis builds on the PNNL technical report titled 2015 IECC: Energy Savings Analysis (Mendon et al. 2015) which identified the prescriptive and mandatory changes introduced by the 2015 IECC compared to the 2012 IECC and determined their energy savings impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy metabolism in Desulfovibrio vulgaris Hildenborough: insights from transcriptome analysis

Sulphate-reducing bacteria are important players in the global sulphur and carbon cycles, with considerable economical and ecological impact. However, the process of sulphate respiration is still incompletely understood. Several mechanisms of energy conservation have been proposed, but it is unclear how the different strategies contribute to the overall process. In order to obtain a deeper insight into the energy metabolism of sulphate-reducers whole-genome microarrays were used to compare the transcriptional response of Desulfovibrio vulgaris Hildenborough grown with hydrogen/sulphate, pyruvate/sulphate, pyruvate with limiting sulphate, and lactate/thiosulphate, relative to growth in lactate/sulphate. Growth with hydrogen/sulphate showed the largest number of differentially expressed genes and the largest changes in transcript levels. In this condition the most up-regulated energy metabolism genes were those coding for the periplasmic [NiFeSe]hydrogenase, followed by the Ech hydrogenase. The results also provide evidence for the involvement of formate cycling and the recently proposed ethanol pathway during growth in hydrogen. The pathway involving CO cycling is relevant during growth on lactate and pyruvate, but not during growth in hydrogen as the most down-regulated genes were those coding for the CO-induced hydrogenase. Growth on lactate/thiosulphate reveals a down-regulation of several energymetabolism genes similar to what was observed in the presence of nitrite. This study identifies the role of several proteins involved in the energy metabolism of D. vulgaris and highlights several novel genes related to this process, revealing a more complex bioenergetic metabolism than previously considered.

59 BASIC BIOLOGICAL SCIENCES↗

Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut (Fact Sheet)

By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Enabled Building Energy Savings (D-E BES)

Building sector energy consumption represents a significant fraction of the overall energy consumption in urban communities. While there has been increasing focus on the development of smart environments to support energy savings in urban commercial buildings, the development of smart environments for the residential sector has been less common. Instead, urban residential energy-saving efforts have focused on improving a building's physical infrastructure, introducing energy-saving appliances, and motivating residents to adopt energy conservation practices. Herein this paper illustrates that creating an affinity between a building resident's thermal preferences and a building apartment's unregulated thermal environment represents an alternative means of generating an energy-efficient environment for multi-family, residential buildings. Two years of 15-min interval summer data, obtained from smart cyber-physical systems installed in 310 apartments across two New York City buildings, is used to develop data-enabled (D-E) models of resident thermal preference and unregulated apartment temperatures. Both of these models use a linear mixed-effects approach. The alignment of optimal resident-apartment pairs is then formulated as an integer-programming problem to explore the building energy saving (BES) potential associated with minimizing the difference between unregulated apartment temperature and the residents' thermal preference based on summer cooling loads. The work shows that the energy saving potential vary with a building's physical characteristics as well as the variation in residents' thermal preferences. The work further demonstrates that both the unregulated temperature and the resident's preferred temperature in a given apartment are not only affected by outside temperature and external relative humidity, but also strongly affected by the apartment's geographic orientation. For the specific buildings considered, up to 28% cooling energy saving is possible with full alignment. The paper provides all building monitoring data as an open source data set.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for large-scale relativistic simulations in the characteristic approach

We present a new computational framework (LEO) that enables us to carry out the very first large-scale, high-resolution computations in the context of the characteristic approach in numerical relativity. At the analytic level, our approach is based on a new implementation of the eth formalism, using a nonstandard representation of the spin-raising and spin-lowering angular operators in terms of nonconformal coordinates on the sphere; we couple this formalism to a partially first-order reduction (in the angular variables) of the Einstein equations. The numerical implementation of our approach supplies the basic building blocks for a highly parallel, easily extensible numerical code. We demonstrate the adaptability and excellent scaling of our numerical code by solving, within our numerical framework, for a scalar field minimally coupled to gravity (the Einstein-Klein-Gordon problem) in 3 dimensions. The nonlinear code is globally second-order convergent, and has been extensively tested using as a reference a calibrated code with the same initial and boundary data and radial marching algorithm. In this context, we show how accurately we can follow quasinormal mode ringing. In the linear regime, we show energy conservation for a number of initial data sets with varying angular structure. A striking result that arises in this context is the saturation of the flow of energy through the Schwarzschild radius. As a final calibration check, we perform a large simulation with resolution never achieved before.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits

Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pacific Northwest Smart Grid Demonstration Project Technology Performance Report Volume 1: Technology Performance

The Pacific Northwest Smart Grid Demonstration (PNWSGD), a $179 million project that was co-funded by the U.S. Department of Energy (DOE) in late 2009, was one of the largest and most comprehensive demonstrations of electricity grid modernization ever completed. The project was one of 16 regional smart grid demonstrations funded by the American Recovery and Reinvestment Act. It was the only demonstration that included multiple states and cooperation from multiple electric utilities, including rural electric co-ops, investor-owned, municipal, and other public utilities. No fewer than 55 unique instantiations of distinct smart grid systems were demonstrated at the projects’ sites. The local objectives for these systems included improved reliability, energy conservation, improved efficiency, and demand responsiveness. The demonstration developed and deployed an innovative transactive system, unique in the world, that coordinated many of the project’s distributed energy resources and demand-responsive components. With the transactive system, additional regional objectives were also addressed, including the mitigation of renewable energy intermittency and the flattening of system load. Using the transactive system, the project coordinated a regional response across the 11 utilities. This region-wide connection from the transmission system down to individual premises equipment was one of the major successes of the project. The project showed that this can be done and assets at the end points can respond dynamically on a wide scale. In principle, a transactive system of this type might eventually help coordinate electricity supply, transmission, distribution, and end uses by distributing mostly automated control responsibilities among the many distributed smart grid domain members and their smart devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation and the industry sector

The following six highly energy intensive industries were studied as targets of energy conservation opportunity: food and kindred products, paper and allied products, chemicals and allied products, petroleum and coal products, stone, glass and clay products, and primary manufacturing. After studying conservation actions within each industry the actions were grouped under three broad categories: increased combustion efficiency, process improvement, and good housekeeping. Some of the results were: (1) approximately 2.18 quads could be saved in 1980 and 2.57 quads in 1985 by installing cogenerative facilities in 50% of the industries, (2) regenerative air-preheaters could result in a 10-15% increase in furnace efficiency representing a 15-25% fuel savings (2.3 to 3.9 quads in 1980 and 2.7 to 4.5 quads in 1985), (3) several major industries have potential for energy savings by recycling-aluminum (0.2 quads), steel (1 quad), glass (0.006 quads), paper and cement (0.08 quads).

Source record↗