Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Polarization measurements as a probe of axion-photon coupling: A study of GRB 221009A

Axionlike particles (ALPs) can be produced in gamma ray bursts, altering the polarization of the electromagnetic emission in these events. For the first time, we derive bounds on the axion-photon coupling from polarization measurements of GRB 221009A, performing a full calculation of the Stokes parameters, as it is typically done in the astrophysics community. Within astrophysical uncertainties, our limits on the axion-photon coupling are competitive with complementary probes in the axion mass range 10 −9 eV ≲ 𝑚 𝑎 ≲ 10 −8 eV, further allowing to probe motivated parameter space of ALP dark matter.

axion-like particles↗

System and method for the direct calorimetric measurement of laser absorptivity of materials

A method and system for calorimetrically measuring the temperature-dependent absorptivity of a homogeneous material dimensioned to be thin and flat with a predetermined uniform thickness and a predetermined porosity. The system includes a material holder adapted to support and thermally isolate the material to be measured, an irradiation source adapted to uniformly irradiate the material with a beam of electromagnetic radiation, and an irradiation source controller adapted to control the irradiation source to uniformly heat the material during a heating period, followed by a cooling period when the material is not irradiated. A thermal sensor measures temperature of the material during the heating and cooling periods, and a computing system first calculates temperature-dependent convective and radiative thermal losses of the material based on the measured temperature of the material during the cooling period when beam intensity is zero, followed by calculation of the temperature-dependent absorptivity of the material based on the temperature-dependent convective and radiative thermal losses determined from the cooling period.

Rubenchik, Alexander↗

Singular charge density at the center of the pion?

We relate the three-dimensional infinite momentum frame spatial charge density of the pion to its electromagnetic form factor F{sub {pi}}(Q{sup 2}). Diverse treatments of the measured form factor data including phenomenological fits, nonrelativistic quark models, the application of perturbative quantum chromodynamics (QCD), QCD sum rules, holographic QCD, and the Nambu-Jona-Lasinio (NJL) model all lead to the result that the charge density at the center of the pion has a logarithmic divergence. Relativistic constituent quark models do not display this singularity. Future measurements planned for larger values of Q{sup 2} may determine whether or not a singularity actually occurs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the local measurement of electric currents and magnetic fields using Thomson scattering in Weibel-unstable plasmas

Here, we demonstrate the capability of the Thomson Scattering (TS) diagnostic to measure locally the microscopic electron and ion currents in counter-streaming plasmas unstable to the Weibel or current-filamentation instability. Synthetic TS spectra are calculated with particle distribution functions obtained from particle-in-cell simulations and used to accurately reproduce the simulated currents. We show that this technique allows accurate local measurements of the magnetic field, thus opening the way for the complete experimental characterization of the growth rate, saturation, and nonlinear dynamics of electromagnetic instabilities in plasmas. We illustrate the application of this diagnostic to experimental TS data, which yields local measurements of the magnetic field in Weibel-unstable plasmas and indicates that the magnetic energy density reaches ~1% of the kinetic energy density of the flows, in agreement with previous numerical studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Measurement of Drift-Alfvén Wave Polarization in Magnetically Confined Fusion Plasmas

Polarization of drift-Alfvén waves, defined as the ratio of electrostatic to electromagnetic fluctuations, has remained unmeasurable in fusion plasmas for decades, despite its pivotal role in understanding wave dynamics and their impact on plasmas. We report the first measurements of drift-Alfvén wave polarization in a hot, magnetically-confined plasma. Here, the breakthrough is enabled by a novel methodology developed from gyrokinetic theory, utilizing fluctuations of electron temperature and density. Analysis of data from the DIII-D tokamak reveals that the waves above the geodesic acoustic mode frequency exhibit dominant electromagnetic polarization, whereas lower frequency waves show a mix of electromagnetic and electrostatic polarization, indicating a strong coupling between shear Alfvén waves and drift-acoustic waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Spin Resonance Study of Fe3+ and Mn2+ Ions in 17-Year-Old Nuclear-Waste-Glass Simulants Containing PuO2 with Different Degrees of 238Pu Substitution

Three samples of a model nuclear waste glass, DRG-P1, P2, and P3, were prepared at PNNL in 1982 with identical chemical compositions but were respectively batched with 0.0, 0.1, and 0.9 wt% of 238PuO2 (half life 87.8 years) partially replacing the 1.0 wt% 239PuO2 present in DRG-P1. In 1999, samples of these glasses were sent to the Naval Research Laboratory for electron spin resonance (ESR) measurements. No radiation-induced point defects were observed. Profound alpha decay-induced changes in the ESR spectra of the batched iron-group ions were found. The spectra recorded for DRG-P1 were shown by absolute spin counts to have ESR intensities equivalent to ~85% of the sum of the batched 8.28 mole% Fe3+ and 2.79 mole% Mn2+, assuming all of those ions to behave as paramagnetic S=5/2 states at room temperature. Separate experiments and calculations ruled out the possibility of precipitated magnetite-like precipitates comprising even so much as 0.01% of the total iron. A relatively weak ESR spectral feature observed at g=4.3 is the known signature of dilute Fe3+ in glasses. However, the strongest ESR signal was found to be characterized by a first-derivative zero crossing at g=2.06 and a peak-to-peak derivative linewidth of ~150 mT, which is virtually invariant in shape with both measurement temperature and alpha-decay dose. It was discovered that these broad line shapes could be accurately simulated as weighted sums of Lorentzian shape functions of differing widths but having the same g value. The absence of any measurable anisotropy in the broad line, coupled with the temperature invariance of its width, imply the existence of extremely strong exchange interactions within clusters of Fe3+, Fe2+, Mn2+, and Ni2+ ions characterized by extremely short-range magnetic order. The result is a speromagnetic system rather than exhibiting a distinct Néel temperature. The most evident ESR effect of 17 years of 238Pu decay is the (irreversible) lowering of the intensity of the "broad line" in rough proportion to the amount of 238Pu in the sample, with concomitant increases in the amplitude of the g=4.3 feature. It was additionally observed that cooling these glasses to successively lower temperatures gives rise to reversible lowering of the broad-line intensity and increasing of the strength of the g=4.3 feature when compared with theoretical expectation for non-interacting paramagnets. The truly remarkable observation that the broad lines could be simulated as weighted sums of pure Lorentzian functions of differing widths fortuitously opened the way for high precision measurements of the ESR intensities of experimental spectra that are far broader than the magnetic field range of the available laboratory electromagnets. The areas under the simulated absorption curves fitted to the experimental spectra in the manner described provided an empirical measure of the degrees to which the present model nuclear waste glasses had been affected by alpha-decay self irradiation. Specifically, the broad-line ESR integrated-intensity data as a function of 238Pu alphadecay dose (proportional to the 238Pu doping level in these fixed-time experiments) proved to be accurately fitted by a simple saturating exponential function asymptotic to zero for infinite-time self irradiation. This result promises a precise means of extrapolating thousands of years into the future the process of "super-vitrification" that results from the creation and rapid quenching of thermal spikes due to alpha decay in glasses immobilizing 239Pu and other actinide elements. In addition, because the ESR spectra of several very different candidate high-level nuclear waste (HLW) glass compositions containing even higher amounts of Fe2O3 are also shown here to be decomposable into sums of pure Lorentzians, the analytical method we describe should be applicable to these and many other HLW glasses containing both iron-group oxides and radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RF Reverb Chamber Radio Frequency Reverberation Chamber

Viewing an experiment in the radio frequency (RF) reverberation chamber, also known as a mode stirred chamber. The chamber is an isolated RF test chamber containing an irregularly shaped paddle capable of measuring a device’s radiated emissions, radiated immunity, shielding effectiveness, and antenna efficiency from 500MHz to 18GHz. The chamber is electromagnetically isolated from extremely low frequencies and is highly reverberant, which creates the fundamental wave chaotic properties required to make statistical measurements.

47 OTHER INSTRUMENTATION↗

Overview of Hall D Complex

Hall D is a new experimental hall at Jefferson Lab, designed for experiments with a photon beam. The primary motivation for Hall D is the GlueX experiment [1,2], dedicated to meson spectroscopy. The Hall D complex consists of: An electron beam line used to extract the 5.5-pass electrons from the accelerator into the Tagger Hall. The designed beam energy is E e = 12 GeV;The Tagger Hall, where the electron beam passes through a thin radiator (~0.01% R.L.) and is deflected into the beam dump. The electrons that lost >30% of their energy in the radiator are detected with scintillator hodoscopes providing a ~0.1% energy resolution for the tagged photons. Aligned diamond radiators allow to produce linearly polarized photons via the Coherent Bremsstrahlung. The beam dump is limited to 60 kW (5 µA at 12 GeV); The Collimator Cave contains a collimator for the photon beam and dipole magnets downstream in order to remove charged particles. The 3.4 mm diameter collimator, located about 75 m downstream of the radiator, selects the central cone of the photon beam increasing its average linear polarization, up to ~40%in the coherent peak at 9 GeV; Hall D contains several elements of the photon beam line, and themain spectrometer. A Pair Spectrometer consists of a thin converter, a dipole magnet, and a two-arm detector used to measure the energy spectrum of the photon beam. The main spectrometer is based on a 2-T superconducting solenoid, 4 m long and 1.85 m bore diameter. The liquid hydrogen target is located in the front part the solenoid. The charged tracks are detected with a set of drift chambers; photons are detected with two electromagnetic calorimeters. There are also scintillator hodoscopes for triggering and time-of-flight measurements. The spectrometer is nearly hermetic in an angular range of 1° < θ < 120 •. The momentum resolution is σ p /p ~ 1 ₋ ₋3% depending on the polar angle θ. The energy resolution of the electromagnetic calorimeters is about 7% at 1 GeV.

Chudakov, Eugene A.↗

Level-1 Trigger and DAQ system of the GlueX experiment

The goal of the GlueX detector at Jefferson Lab is to study fundamental questions of the quantum chromodynamics, i.e., the nature of confinement of gluons and quarks. The detector's design is optimized to measure the spectrum of exotic mesons that are expected to be produced in interactions of 8.4 - 9.0 GeV linearly polarized photons with a liquid hydrogen target. The GlueX trigger and DAQ electronics is based on pipelined TDC boards and FADC boards running at a 250 MHz clock. The trigger logic is implemented on special purpose programmable electronics boards with Field-Programmable Gate Array chips. Two types of boards are used: Crate Trigger Processors and Global Trigger Processors. All trigger electronics is hosted in VXS crates. The Level-1 trigger should reduce the 200 MHz electromagnetic rate and the 400 kHz hadronic rate to 200 kHz total rate. The trigger algorithm makes use of a measurement of the energy deposition in two electromagnetic calorimeters and hit counts in the start counter, the time-of-flight detector, and the tagger hodoscopes. We will present the trigger and DAQ design of the GlueX experiment and describe the Level-1 trigger algorithm in detail..

Somov, Alexander↗

Level-1 Trigger and DAQ system of the GlueX experiment

he goal of the GlueX detector at Jefferson Lab is to study fundamental questions of the quantum chromodynamics, i.e., the nature of confinement of gluons and quarks. The detector's design is optimized to measure the spectrum of exotic mesons that are expected to be produced in interactions of 8.4 - 9.0 GeV linearly polarized photons with a liquid hydrogen target. The GlueX trigger and DAQ electronics is based on pipelined TDC boards and FADC boards running at a 250 MHz clock. The trigger logic is implemented on special purpose programmable electronics boards with Field-Programmable Gate Array chips. Two types of boards are used: Crate Trigger Processors and Global Trigger Processors. All trigger electronics is hosted in VXS crates. The Level-1 trigger should reduce the 200 MHz electromagnetic rate and the 400 kHz hadronic rate to 200 kHz total rate. The trigger algorithm makes use of a measurement of the energy deposition in two electromagnetic calorimeters and hit counts in

08 HYDROGEN↗

Minimizers with discontinuous velocities for the electromagnetic variational method

The electromagnetic two-body problem has neutral differential delay equations of motion that, for generic boundary data, can have solutions with discontinuous derivatives. If one wants to use these neutral differential delay equations with arbitrary boundary data, solutions with discontinuous derivatives must be expected and allowed. Surprisingly, Wheeler-Feynman electrodynamics has a boundary value variational method for which minimizer trajectories with discontinuous derivatives are also expected, as we show here. The variational method defines continuous trajectories with piecewise defined velocities and accelerations, and electromagnetic fields defined by the Euler-Lagrange equations on trajectory points. Here we use the piecewise defined minimizers with the Lienard-Wierchert formulas to define generalized electromagnetic fields almost everywhere (but on sets of points of zero measure where the advanced/retarded velocities and/or accelerations are discontinuous). Along with this generalization we formulate the generalized absorber hypothesis that the far fields vanish asymptotically almost everywhere and show that localized orbits with far fields vanishing almost everywhere must have discontinuous velocities on sewing chains of breaking points. We give the general solution for localized orbits with vanishing far fields by solving a (linear) neutral differential delay equation for these far fields. We discuss the physics of orbits with discontinuous derivatives stressing the differences to the variational methods of classical mechanics and the existence of a spinorial four-current associated with the generalized variational electrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microstructural Characterization of Al 4 C 3 in Aluminum-Graphite Composite Prepared by Electron-Beam Melting

We prepared graphite infused aluminum composites by electron-beam vacuum melting and electromagnetic stirring with 0% and 4wt% graphite addition. Bulk density of 2.69 g/cm 3 was measured for samples with 0% graphite addition (AlCv0) and 2.66 g/cm 3 for samples with 4 wt% graphite addition (AlCv4). Both are >99% of their theoretical values. X-ray diffraction indicated that AlCv0 is phase pure, while the AlCv4 sample is a composite consisting of aluminum, Al 4 C 3 , and graphite. Electron microscopy and energy dispersive X-ray spectroscopy revealed pockets of carbon rich phase of 10 to 50 μm in sizes dispersed in the Al matrix in AlCv4. Scanning transmission electron microscopy (STEM) showed that Al 4 C 3 crystallites of 1-2 μm sizes that are mostly located near the outer shell of the pockets of carbon rich phase and with undissolved graphite at the center. Thermal conductivity of 107.8 W/m·K was measured for the AlCv4 and 226.7 W/m·K for the AlCv0. Our work demonstrated the feasibility of producing pore-free high density graphite infused aluminum composite materials by electron-beam melting and electromagnetic stirring in vacuum.

36 MATERIALS SCIENCE↗

Measurement of the anomalous precession frequency in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low energy observable that can be both measured and computed with high precision, therefore it can provide an important test of the Standard Model and it is a sensitive probe for new physics. In particular, any discrepancy between the experimental value and the theoretical prediction can be due to Beyond Standard Model physics contribution. The E989 Muon $g-2$ Experiment at Fermilab aims to measure $a_\mu$ with a precision of 140 parts per billion, four time more precisely than the previous experiment at Brookhaven National Laboratory (BNL). E989 seeks to either resolve or confirm the observed discrepancy of $3.7\sigma$ between the Standard Model value and the experimental one. The $a_\mu$ measurement requires a precise determination of both the muon spin anomalous precession frequency and the average magnetic field seen by the muons as they circulate in a storage ring. The anomalous precession frequency measurement is b ased on the time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters placed around the inner circumference of the ring, while the magnetic field is constantly monitored by NMR probes. Last spring, E989 has published a new measurement of $a_\mu$ from the 2018 data-taking campaign, confirming the previous BNL value with comparable precision, bringing the discrepancy with the theoretical value to $4.2\sigma$. The candidate worked on the measurement of the anomalous precession frequency and on the estimate of the related systematic uncertainties of the 2018 data, giving an important contribution to the data analysis. The result presented in chapters 4 and 5 of this dissertation was included, among three other analyses, to determine the estimate of the anomalous magnetic moment by the Muon g-2 experiment. This work will present the anomalous precession frequency analysis technique and its result, the related systematics and finally the latest $a_\mu$ result.

Sorbara, Matteo↗

Plasmonic coupling of SiO{sub 2}-Ag 'post-cap' nanostructures and silver film for surface enhanced Raman scattering

We demonstrate a surface enhanced Raman scattering (SERS) substrate consisting of SiO{sub 2}-Ag''post-cap'' nanostructures with an underlying silver film fabricated by the glancing angle deposition technique. Electromagnetic simulations predict that SERS enhancement is strongly polarization-dependent, consistent with experimental measurements. Optimized coupling between Ag cap nanoparticles and the underlying silver film can be achieved by controlling the thickness of SiO{sub 2} post sandwiched between them to significantly enhance local electric-field intensity and to increase the density of electromagnetic hot spots. A maximum SERS enhancement factor of 2.38x10{sup 9} within the hot spot region is demonstrated, providing sufficient sensitivity for many important applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

NEW Fe IX LINE IDENTIFICATIONS USING SOLAR AND HELIOSPHERIC OBSERVATORY/SOLAR ULTRAVIOLET MEASUREMENT OF EMITTED RADIATION AND HINODE/EIS JOINT OBSERVATIONS OF THE QUIET SUN

In this work, we study joint observations of Hinode/EUV Imaging Spectrometer (EIS) and Solar and Heliospheric Observatory/Solar Ultraviolet Measurement of Emitted Radiation of Fe IX lines emitted by the same level of the high energy configuration 3s {sup 2}3p {sup 5}4p. The intensity ratios of these lines are dependent on atomic physics parameters only and not on the physical parameters of the emitting plasma, so that they are excellent tools to verify the relative intensity calibration of high-resolution spectrometers that work in the 170-200 A and 700-850 A wavelength ranges. We carry out extensive atomic physics calculations to improve the accuracy of the predicted intensity ratio, and compare the results with simultaneous EIS-SUMER observations of an off-disk quiet Sun region. We were able to identify two ultraviolet lines in the SUMER spectrum that are emitted by the same level that emits one bright line in the EIS wavelength range. Comparison between predicted and measured intensity ratios, wavelengths and energy separation of Fe IX levels confirms the identifications we make. Blending and calibration uncertainties are discussed. The results of this work are important for cross-calibrating EIS and SUMER, as well as future instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

$\overline{\Sigma }^{\pm }$ production in $\text {pp}$ and $\text {p}{-}\text{Pb}$ collisions at $\sqrt{s_{\textrm{NN}}} = 5.02$ TeV with ALICE

The transverse momentum spectra and integrated yields of anti-$Σ$ hyperons ($\overline{\Sigma}^{\pm}$) have been measured in and collisions at $\sqrt{s_{\textrm{NN}}} = 5.02$ TeV with the ALICE experiment. Measurements are performed via the newly accessed decay channel $\overline{\Sigma}^{\pm}$ → $\bar{\textrm{n}}π^±$. A new method of antineutron reconstruction with the PHOS electromagnetic spectrometer is developed and applied to this analysis. The p T spectra of $\overline{\Sigma}^{\pm}$ are measured in the range 0.5 < p T < 3 GeV/c and compared to predictions of the PYTHIA 8, DPMJET, PHOJET, EPOS LHC and EPOS4 models. The EPOS LHC and EPOS4 models provide the best descriptions of the measured spectra both in pp and p-Pb collisions, while models which do not account for multiparton interactions provide a considerably worse description at high p T . The total yields of $\overline{\Sigma }^{\pm }$ in both pp and p-Pb collisions are compared to predictions of the Thermal-FIST model and dynamical models PYTHIA 8, DPMJET, PHOJET, EPOS LHC and EPOS4. All models reproduce the total yields in both colliding systems within uncertainties. The nuclear modification factors R pPb for both $\overline{\Sigma}^{+}$ and $\overline{\Sigma}^{-}$ are evaluated and compared to those of protons, $Λ$ and $Ξ$ hyperons, and predictions of EPOS LHC and EPOS4 models. No deviations of R pPb for $\overline{\Sigma}^{\pm}$ from the model predictions or measurements for other hadrons are found within uncertainties.

Abualrob, I. J. [University of Houston] (ORCID:000↗

Beam-Helicity Asymmetries in Double-Pion Photoproduction off the Proton

Beam-helicity asymmetries have been measured at the MAMI accelerator in Mainz in the three isospin channels gamma-vectorp->pi{sup +}pi{sup 0}n, gamma-vectorp->pi{sup 0}pi{sup 0}p, and gamma-vectorp->pi{sup +}pi{sup -}p. The circularly polarized photons, produced from bremsstrahlung of longitudinally polarized electrons, were tagged with the Glasgow magnetic spectrometer. Charged pions and the decay photons of pi{sup 0} mesons were detected in a 4pi electromagnetic calorimeter which combined the Crystal Ball detector with the TAPS detector. The precisely measured asymmetries are very sensitive to details of the production processes and are thus key observables in the modeling of the reaction dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗