Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.

60 APPLIED LIFE SCIENCES↗

SU-F-J-212: Enabling Conventional Cone Beam CT with the Capability of Dual Energy Imaging Using a Simple Add-On Beam Modifier

Purpose: In searching for a robust, efficient and cost-effective dual energy cone beam CT (DECBCT) solution for various radiation oncology applications, in particularly for improved proton dose planning/replanning accuracy and DE-CBCT guided radiation therapy, we investigate a novel energy modulation scheme using a beam modifier placed between the source and patient and optimize its geometric configuration for routine clinical use. Methods: The study was performed using a Hitachi CBCT scanner and the tube voltage was set at 125 kVp. The higher energy beam was obtained by filtering the incident utilizing a beam modulation layer (material: copper, thickness: 1.8 mm). To avoid the need for double scans (one with and one without the energy modulator), the modulation layer was configured to cover only the half of the X-ray beam so that two sets of sinograms corresponding low and high energies were collected after a single gantry rotation of 360 deg. The average high energy and low energy HU numbers (HUhigh and HUlow) were derived for pixels in a defined region-of-interest, respectively. Results: The beam modifier increased the threshold of the energy spectrum from ∼20 keV up to ∼50 keV. Two complete sets of images were obtained with good alignment between the high energy and low-energy cases without any artifact observed (Fig. 2). The HUlow/HUhigh is ∼0/0 (water), ∼394/238 (brain), ∼1283/1085 (cortical bone) and ∼3000/1800 (titanium). Conclusion: The feasibility of the proposed DECT implementation using a beam modifier has been demonstrated. Compared to the existing DECT solutions, the proposed scheme is much more cost-effective and requires minimum hardware modification. The work lays foundation for us to study the quantification of HU values to derive material density images and atomic number (and electron density) of substances.

60 APPLIED LIFE SCIENCES↗

Short-Course Hypofractionated Radiation Therapy With Boost in Women With Stages 0 to IIIa Breast Cancer: A Phase 2 Trial

Purpose: Conventionally fractionated whole-breast irradiation (WBI) with a boost takes approximately 6 to 7 weeks. We evaluated a short course of hypofractionated (HF), accelerated WBI in which therapy was completed in 3 weeks inclusive of a sequential boost. Methods and Materials: We delivered a whole-breast dose of 36.63 Gy in 11 fractions of 3.33 Gy over 11 days, followed by a lumpectomy bed boost in 4 fractions of 3.33 Gy delivered once daily for a total of 15 treatment days. Acute toxicities were scored using Common Terminology Criteria for Adverse Events version 4. Late toxicities were scored using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scale. Cosmesis was scored using the Harvard Cosmesis Scale. Our primary endpoint was freedom from locoregional failure; we incorporated early stopping criteria based on predefined toxicity thresholds. Cosmesis was examined as a secondary endpoint. Results: We enrolled 83 women with stages 0 to IIIa breast cancer. After a median follow-up of 40 months, 2 cases of isolated ipsilateral breast tumor recurrence occurred (2 of 83; crude rate, 2.4%). Three-year estimated local recurrence-free survival was 95.9% (95% confidence interval [CI]: 87.8%-98.7%). The 3-year estimated distant recurrence-free survival was 97.3% (95% CI: 89.8%-99.3%). Three-year secondary malignancy-free survival was 94.3% (95% CI: 85.3%-97.8%). Twenty-nine patients (34%) had grade 2 acute toxicity, and 1 patient had a late grade 2 toxicity (fibrosis). One patient had acute grade 3 dermatitis, whereas 2 patients experienced grade 3 late skin toxicity. Ninety-four percent of evaluable patients had good or excellent cosmesis. Conclusions: Our phase 2 institutional study offers one of the shortest courses of HF therapy, delivered in 15 fractions inclusive of a sequential boost. We demonstrated expected low toxicity and high local control rates with good to excellent cosmetic outcomes. This fractionation scheme is feasible and well tolerated and offers women WBI in a highly convenient schedule.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Comparison of signal to noise ratios from spatial and frequency domain formulations of nonprewhitening model observers in digital mammography

Purpose: Image quality indices based upon model observers are promising alternatives to laborious human readings of contrast-detail images. This is especially appealing in digital mammography as limiting values for contrast thresholds determine, according to some international protocols, the acceptability of these systems in the radiological practice. The objective of the present study was to compare the signal to noise ratios (SNR) obtained with two nonprewhitening matched filter model observer approaches, one in the spatial domain and the other in the frequency domain, and with both of them worked out for disks as present in the CDMAM phantom. Methods: The analysis was performed using images acquired with the Siemens Novation and Inspiration digital mammography systems. The spatial domain formulation uses a series of high dose CDMAM images as the signal and a routine exposure of two flood images to calculate the covariance matrix. The frequency domain approach uses the mathematical description of a disk and modulation transfer function (MTF) and noise power spectrum (NPS) calculated from images. Results: For both systems most of the SNR values calculated in the frequency domain were in very good agreement with the SNR values calculated in the spatial domain. Both the formulations in the frequency domain and in the spatial domain show a linear relationship between SNR and the diameter of the CDMAM discs. Conclusions: The results suggest that both formulations of the model observer lead to very similar figures of merit. This is a step forward in the adoption of figures of merit based on NPS and MTF for the acceptance testing of mammography systems.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

A common fluence threshold for first positive and second positive phototropism in Arabidopsis thaliana

The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 x 10(-5) to 6.5 x 10(-3) micromoles per square meter per second. The threshold values in the fluence rate-response curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system.

NASA Discipline Number 29-20↗

Initiation stress threshold irradiation assisted stress corrosion cracking criterion assessment for core internals in PWR environment

Irradiation assisted stress corrosion cracking (IASCC) is a problem of growing importance in pressurized water reactors (PWR). An understanding of the mechanism(s) of IASCC is required in order to provide guidance for the development of mitigation strategies. One of the principal reasons why the IASCC mechanism(s) has been so difficult to understand is the inseparability of the different IASCC potential contributors evolutions due to neutron irradiation. The potential contributors to IASCC in PWR primary water are: (i) radiation induced segregation (RIS) at grain boundaries, (ii) radiation induced microstructure (formation and growth of dislocations loops, voids, bubbles, phases), (iii) localized deformation under loading, (iv) irradiation creep and transmutations. While the development of some of the contributors (RIS, microstructure) with increasing doses are at least qualitatively well understood, the role of these changes on IASCC remains unclear. Parallel to fundamental understanding developments relative to IASCC, well controlled laboratory tests on neutron irradiated stainless steels are needed to assess the main mechanisms and also to establish an engineering criterion relative to the initiation of fracture due to IASCC. First part of this study describes the methodology carried out at CEA in order to provide more experimental data from constant load tests dedicated to the study of initiation of SCC on neutron irradiated stainless steel. A description of the autoclave recirculation loop dedicated to SCC tests on neutron irradiated materials is then given. This autoclave recirculation loop has been started on July 2010 with the first SCC test on an irradiated stainless steel (grade 316) performed at CEA. The main steps of the interrupted SCC tests are then described. Second part of this paper reports the partial results of the first test performed on a highly neutron irradiated material. (authors)

36 MATERIALS SCIENCE↗

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗

Monte Carlo electron-photon transport using GPUs as an accelerator: Results for a water-aluminum-water phantom

An electron-photon coupled Monte Carlo code ARCHER - Accelerated Radiation-transport Computations in Heterogeneous Environments - is being developed at Rensselaer Polytechnic Institute as a software test bed for emerging heterogeneous high performance computers that utilize accelerators such as GPUs. In this paper, the preliminary results of code development and testing are presented. The electron transport in media was modeled using the class-II condensed history method. The electron energy considered ranges from a few hundred keV to 30 MeV. Moller scattering and bremsstrahlung processes above a preset energy were explicitly modeled. Energy loss below that threshold was accounted for using the Continuously Slowing Down Approximation (CSDA). Photon transport was dealt with using the delta tracking method. Photoelectric effect, Compton scattering and pair production were modeled. Voxelised geometry was supported. A serial ARHCHER-CPU was first written in C++. The code was then ported to the GPU platform using CUDA C. The hardware involved a desktop PC with an Intel Xeon X5660 CPU and six NVIDIA Tesla M2090 GPUs. ARHCHER was tested for a case of 20 MeV electron beam incident perpendicularly on a water-aluminum-water phantom. The depth and lateral dose profiles were found to agree with results obtained from well tested MC codes. Using six GPU cards, 6x10{sup 6} histories of electrons were simulated within 2 seconds. In comparison, the same case running the EGSnrc and MCNPX codes required 1645 seconds and 9213 seconds, respectively, on a CPU with a single core used. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation damages the silicates present in polyphasic mineral aggregates causing concrete’s degradation

While many U.S. nuclear power plants have submitted Subsequent License Renewal Application to operate beyond 60 years, others are already considering Operations Beyond Eighty years. In such cases, concrete biological shields are exposed to neutron and gamma radiation exceeding prescribed thresholds. Radiation-induced volumetric expansion (RIVE), extensively studied in single crystals, may also contribute to the degradation of polycrystalline aggregates. Since minerals differ in atomic structure and chemistry, radiation can affect them in distinct ways. This study examines quartzite, marble, and limestone to evaluate how irradiation affects their physical attributes and chemical reactivity. Results show crystalline silicates experience significant RIVE damage and enhanced reactivity in alkaline solutions compared to non-irradiated phases. Enhanced intra- and inter-granular dissolution could compromise aggregate integrity. An empirical correlation links silicate dissolution rate to atomic constraints (density, rigidity) and radiation dose, providing a predictive framework for estimating changes in silicate aggregate properties within radiation-exposed concrete.

Bouissonnié, Arnaud [Univ. of California, Los Ange↗

Application of multi-criteria decision analysis techniques and decision support framework for informing select agent designation for agricultural animal pathogens

The United States Department of Agriculture (USDA), Division of Agricultural Select Agents and Toxins (DASAT) established a list of biological agents and toxins (Select Agent List) that potentially threaten agricultural health and safety, the procedures governing the transfer of those agents, and training requirements for entities working with them. Every 2 years the USDA DASAT reviews the Select Agent List, using subject matter experts (SMEs) to perform an assessment and rank the agents. To assist the USDA DASAT biennial review process, we explored the applicability of multi-criteria decision analysis (MCDA) techniques and a Decision Support Framework (DSF) in a logic tree format to identify pathogens for consideration as select agents, applying the approach broadly to include non-select agents to evaluate its robustness and generality. We conducted a literature review of 41 pathogens against 21 criteria for assessing agricultural threat, economic impact, and bioterrorism risk and documented the findings to support this assessment. The most prominent data gaps were those for aerosol stability and animal infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. The MCDA analysis supported the intuitive sense that select agents should rank high on the relative risk scale when considering agricultural health consequences of a bioterrorism attack. However, comparing select agents with non-select agents indicated that there was not a clean break in scores to suggest thresholds for designating select agents, requiring subject matter expertise collectively to establish which analytical results were in good agreement to support the intended purpose in designating select agents. The DSF utilized a logic tree approach to identify pathogens that are of sufficiently low concern that they can be ruled out from consideration as a select agent. In contrast to the MCDA approach, the DSF rules out a pathogen if it fails to meet even one criteria threshold. Both the MCDA and DSF approaches arrived at similar conclusions, suggesting the value of employing the two analytical approaches to add robustness for decision making.

60 APPLIED LIFE SCIENCES↗

Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42-216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy. The application of this method to IORT lead to identify three safety measures for risk mitigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A summary of the results from the DOE advanced gas reactor (AGR) fuel development and qualification program

Modular high temperature gas-cooled reactor (HTGR) designs were developed to provide natural safety, which prevents core damage under all licensing basis events. The principle that guides their design concepts is to passively maintain core temperatures below fission product release thresholds under all accident scenarios. The required level of fuel performance and fission product retention reduces the radioactive source term by many orders of magnitude relative to source terms for other reactor types and allows a graded approach to emergency planning and the potential elimination of the need for evacuation and sheltering beyond a small exclusion area. Achieving this level, however, is predicated on exceptionally high coated-particle fuel fabrication quality and excellent performance under normal operation and accident conditions. The design goal of modular HTGRs is to meet the Environmental Protection Agency (EPA) Protective Action Guides (PAGs) for offsite dose at the Exclusion Area Boundary (EAB). To achieve this, the reactor design concepts require a level of fuel integrity that is far better than that achieved for all prior U.S.-manufactured tristructural isotropic (TRISO) coated particle fuel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Total Ionizing Dose Effects in MOS Oxides and Devices

The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.

Oldham, Timothy R.↗

Highly Accelerated Irradiation in 5 Fractions (HAI-5): Feasibility in Elderly Women With Early or Locally Advanced Breast Cancer

Purpose: To investigate, in a prospective phase 1 to 2 trial, the safety and feasibility of delivering external beam radiation therapy in 5 fractions to the breast or thoracic wall, including boost and/or lymph nodes if needed, to women aged ≥65 years with breast cancer. Methods and Materials: Ninety-five patients aged ≥65 years, referred for adjuvant radiation therapy, were treated in 5 fractions over 12 days with a total dose of 28.5 Gy/5.7 Gy to the breast or thoracic wall and, if indicated, 27 Gy/5.4 Gy to the lymph node regions and 32.5 Gy/6.5 Gy to 34.5 Gy/6.9 Gy to the tumor bed. The primary endpoint was clinically relevant dermatitis (grade ≥2). Results: Mean follow-up time was 5.6 months, and mean age was 73.6 years. Clinically relevant dermatitis was observed in 11.6% of patients and only occurred in breast irradiation with boost (17.5% grade 2-3 vs 0% in the no-boost group). Although doses were high, treatment delivery with intensity modulated radiation therapy was swift, except for complex treatments, including lymph nodes for which single-arc volumetric modulated arc therapy was needed to reduce beam-on time. Conclusion: Accelerated radiation therapy in 5 fractions was technically feasible and resulted in low acute toxicity. Clinically relevant erythema was only observed in patients receiving a boost, but still at an acceptable rate. Although the follow-up is still short, the results on acute toxicity after accelerated radiation therapy were encouraging. A 5-fraction schedule is well tolerated in the elderly and may lower the threshold for radiation therapy in this population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polycyclic aromatic hydrocarbons and cannabinoids in secondhand cannabis smoke

The legalization of cannabis is exposing more people to secondhand smoke (SHS) generated during cannabis use. Given the serious health effects caused by tobacco SHS, there is a need to assess the potential health effects of exposure to cannabis SHS. As a step toward this, we measured the concentrations of cannabinoids, nicotine and polycyclic aromatic hydrocarbons (PAHs) in air samples collected in public places where cannabis was being consumed. These were compared with concentrations in exhaled aerosols from cannabis smoking and vaping, and in tobacco SHS. Tetrahydrocannabinol concentrations were 22 to 255 µg/m 3 in field samples, below the threshold for psychoactive effects. Nicotine concentrations in field samples did not exceed 1 µg/m 3 . The total PAH concentrations in field samples were from 3.2 to 80.5 ng/m 3 , depending on location type. By contrast, PAH levels averaged 72 ng/m 3 in tobacco SHS and 220 ng/m 3 in the more concentrated, exhaled cannabis aerosols. A total of 22 different PAHs were identified in field samples of cannabis aerosols, from which benz[a]anthracene (B[a]A) was present in the highest concentrations. The PAH profile of cannabis aerosols was different from that of tobacco SHS. A preliminary cancer risk evaluation showed that the dose associated with inhalation of cannabis SHS during an 8-h work shift exceeded the California No Significant Risk Level for B[a]A at all venues where cannabis was consumed primarily via smoking. In summary, the consumption of cannabis, by smoking and by vaporizing, can create aerosols that contain carcinogenic PAHs. Thus breathing secondhand cannabis aerosols increases exposure to carcinogens.

Aerosol↗

Predictors of Grade 3 or Higher Late Bowel Toxicity in Patients Undergoing Pelvic Radiation for Cervical Cancer: Results From a Prospective Study

Purpose: The present study investigates relationship between dose–volume parameters and severe bowel toxicity after postoperative radiation treatment (PORT) for cervical cancer. Methods and Materials: From June 2010 to December 2012, a total of 71 patients undergoing PORT were included. Small bowel (SB) and large bowel (LB) loops were contoured 2 cm above the target volume. The volume of SB and LB that received 15 Gy, 30 Gy, and 40 Gy was calculated (V15 SB, V15 LB, V30 SB, V30 LB, V40 SB, V 40 LB). On follow-up, bowel toxicity was scored using Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. A reciever operating characteristic (ROC) curve identified volume thresholds that predicted for grade 3 or higher toxicity with highest specificity. All data was dichotomized across these identified cut-off values. Univariate and multivariate analysis was performed using SPSS, version 15. Results: The median patient age was 47 years (range, 35-65 years). Of the 71 patients, 46 received image-guided intensity modulated radiation therapy, and 25 received conformal radiation (50 Gy in 25 fractions for 5 weeks). Overall, 63 of 71 patients received concurrent chemotherapy. On a median follow-up of 18 months (range, 8-29 months), grade 2 or higher bowel toxicity was seen in 22 of 71 patients (30.9%) and grade 3 or higher bowel toxicity was seen in 9 patients (12.6%). On univariate analysis, V15 SB <275 cc (P=.01), V30 SB <190 cc (P=.02), V40 SB <150 cc (P=.01), and V15 LB <250 cc (P=.03), and V40 LB <90 cc (P=.04) predicted for absence of grade 3 or higher toxicity. No other patient- or treatment-related factors were statistically significant. On multivariate analysis, only V15 SB (P=.002) and V15 LB (P=.03) were statistically significant. Conclusions: V 15 Gy SB and LB are independent predictors of late grade 3 or higher toxicity. Restricting V15 SB and V15 LB to <275 cc and <250 cc can reduce grade 3 or higher toxicity to less than 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗