Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Sensor Networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

650 records · Page 37

Land-Use and Land-Cover Change around Mobile Bay, Alabama from 1974-2008

This document summarizes the major findings of a Gulf of Mexico Application Pilot project led by NASA Stennis Space Center (SSC) in conjunction with a regional collaboration network of the Gulf of Mexico Alliance (GOMA). NASA researchers processed and analyzed multi-temporal Landsat data to assess land-use and land-cover (LULC) changes in the coastal counties of Mobile and Baldwin, AL between 1974 and 2008. Our goal was to create satellite-based LULC data products using methods that could be transferable to other coastal areas of concern within the Gulf of Mexico. The Mobile Bay National Estuary Program (MBNEP) is the primary end-user, however, several other state and local groups may benefit from the project s data products that will be available through NOAA-NCDDC s Regional Ecosystem Data Management program. Mobile Bay is a critical ecologic and economic region in the Gulf of Mexico and to the entire country. Mobile Bay was designated as an estuary of national significance in 1996. This estuary receives the fourth largest freshwater inflow in the United States. It provides vital nursery habitat for commercially and recreationally important fish species. It has exceptional aquatic and terrestrial bio-diversity, however, its estuary health is influenced by changing LULC patterns, such as urbanization. Mobile and Baldwin counties have experienced a population growth of 1.1% and 20.5% from 2000-2006. Urban expansion and population growth are likely to accelerate with the construction and operation of the ThyssenKrupp steel mill in the northeast portion of Mobile County. Land-use and land-cover change can negatively impact Gulf coast water quality and ecological resources. The conversion of forest to urban cover types impacts the carbon cycle and increases the freshwater and sediment in coastal waters. Increased freshwater runoff decreases salinity and increases the turbidity of coastal waters, thus impacting the growth potential of submerged aquatic vegetation (SAV), which is critical nursing ground for many Gulf fish species. A survey of Mobile Bay SAV showed widespread decreases since the 1940s. Prior to our project, coastal environmental managers in Baldwin and Mobile counties needed more understanding of the historical LULC for properly assessing the impacts of urbanization. In particular, more information on the location and extent of changing urbanization LULC patterns was needed to aid LULC planning and to assess predictions of future LULC patterns. Our products will assist the coastal environmental managers and land-use planners in making better community growth planning decisions. Our project also will help to establish a historical baseline of LULC distributions, which is a fundamental need in any stewardship plan. The primary research objective of our project was to produce historic and current geospatial LULC change products across a 34-year time frame. A multi-decadal coastal LULC change product was the major project deliverable. The geographic extent and nature of change was quantified and assessed for the upland herbaceous, barren, open water, urban, upland forest, woody wetland, and non-woody wetlanddominated land cover types. We focused on regional analyses of decadal-scale urban expansion and watershed-scaled analyses of LULC change for multiple areas of concern to the Mobile Bay NEP (Figure A). We used the following dates to derive LULC classification products from Landsat data: 1974, 1979, 1984, 1988, 1991, 1996, 2001, 2005, and 2008. We assessed the accuracy of our products using randomly sampled locations and digital geospatial reference data including field survey data, high resolution orthorectified aerial photography, high resolution multispectral and panchromatic satellite data displays (from QuickBird and Corona sensors), digital elevation model data, and National Wetlands Inventory wetland cover type data. NOAA s Coastal Change Assessment Program s (C-CAP) and National Land Cover Database (NLCD) procts were used for qualitative comparison in assessing map accuracy. We calculated an average overall classification accuracy of 87% with similar overall accuracies for the older (MSS) and newer (TM and ETM) Landsat LULC products.

Ellis, Jean↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗