Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Evaluation of Fieldbus and OPC for Advanced Life Support

FOUNDATION(Tm) Fieldbus and OP(TM) (OLE(TM)for Process Control) technologies were integrated into an existing control system for a crop growth chamber at NASA Ames Research Center. FOUNDATION(TM) Fieldbus is a digital, bi-directional, multi-drop, serial communications network which functions essentially as a LAN for sensors. FOUNDATION(TM) Fieldbus is heterarchical, with publishers and subscribers of data performing complex control functions at low levels without centralized control and its associated overhead. OPC(TM) is a set of interfaces which replace proprietary drivers with a transparent means of exchanging data between the fieldbus and applications. The objectives were: (1) to integrate FOUNDATION(TM) Fieldbus into existing ALS hardware and determine its overall effectiveness and reliability and, (2) to quantify any savings produced by using fieldbus and OPC technologies. We encountered several problems with the FOUNDATION(TM) Fieldbus hardware chosen. Our hardware exposed 100 data for each channel of the fieldbus. The fieldbus configurator software used to program the fieldbus was simply not adequate. The fieldbus was also not inherently reliable. It lost its settings twice during our tests for unknown reasons. OPC also had issues. It did not function at all as supplied, requiring substitution of some of its components with those from other vendors. It would stop working after a fixed period of time. Certain database calls eventually lock the machine. Overall, we would not recommend FOUNDATION(TM) Fieldbus: it was too difficult to implement with little overall added value. It also seems unlikely that FOUNDATION(TM) Fieldbus will gain sufficient penetration into the laboratory instrument market to ever be cost effective for the ALS community. OPC had good reliability and performance once a stable installation was achieved. It allowed a rapid change to an alternative software strategy when our first strategy failed. It is a cost effective solution to distributed control systems development.

Boulanger, Richard P.↗

System Miniaturization Via Heterogeneous Integration of Electronic Devices for Deep Space Missions

The scientific devices designed for each of the Outer Planets Program Focuses will likely be groundbreaking not only with respect to their scientific role but also regarding the electronics required to perform such investigations. In the past, the performance of packaged electronics was limited by the components themselves, with minimal influence of the packaging technology. The rapid development of integrated circuit technology, however, has drastically increased the importance of packaging technology in the ultimate performance of devices. If not carefully considered in the overall design, the packaging may become the limiting factor in the operation of the system. Although industry is responsible for several significant accomplishments in the field of electronics packaging, deep space/outer planet missions must take into account additional requirements such as extremely low temperatures, high radiation levels, hermetic sealing, and severe size and weight limitations. Therefore, the present investigation has been designed to meet the needs of NASA's sensor intensive outer planets program by combining (using flip chip technology) an array of devices (including analog, digital, power volt-age, passives, and MEMS) into a miniaturized heterogeneous system and utilizing optical buses to enable autonomy. Additional information is contained in the original extended abstract.

DelCastillo, L.↗

Mosad and Stream Vision For A Telerobotic, Flying Camera System

Two full custom camera systems using the Multiplexed OverSample Analog to Digital (MOSAD) conversion technology for visible light sensing were built and demonstrated. They include a photo gate sensor and a photo diode sensor. The system includes the camera assembly, driver interface assembly, a frame stabler board with integrated decimeter and Windows 2000 compatible software for real time image display. An array size of 320X240 with 16 micron pixel pitch was developed for compatibility with 0.3 inch CCTV optics. With 1.2 micron technology, a 73% fill factor was achieved. Noise measurements indicated 9 to 11 bits operating with 13.7 bits best case. Power measured under 10 milliwatts at 400 samples per second. Nonuniformity variation was below noise floor. Pictures were taken with different cameras during the characterization study to demonstrate the operable range. The successful conclusion of this program demonstrates the utility of the MOSAD for NASA missions, providing superior performance over CMOS and lower cost and power consumption over CCD. The MOSAD approach also provides a path to radiation hardening for space based applications.

Mandl, William↗

Dynamic Optical Filtration

A dynamic optical filtration system and method effectively blocks bright light sources without impairing view of the remainder of the scene. A sensor measures light intensity and position so that selected cells of a shading matrix may interrupt the view of the bright light source by a receptor. A beamsplitter may be used so that the sensor may be located away from the receptor. The shading matrix may also be replaced by a digital micromirror device, which selectively sends image data to the receptor.

Jean-Loup Chretien↗

March 2003 EOS Aqua AMSR-E Arctic Sea Ice Field Campaign

An overview of the March 2003 coordinated sea ice field campaign in the Alaskan Arctic is presented with reference to the papers in this special section. This campaign is part of the program to validate the Aqua Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E) sea ice products. Standard AMSR-E sea ice products include sea ice concentration, sea ice temperature, and snow depth on sea ice. The validation program consists of three elements, namely: 1) satellite data comparisons; 2) coordinated satellite/aircraft surface measurements; and 3) modeling and sensitivity analyses. Landsat-7 and RADARSAT observations were used in comparative studies with the retrieved AMSR-E sea ice concentrations. The aircraft sensors provided high-resolution microwave imagery of the surface, atmospheric profiles of temperature and humidity, and digital records of sea ice conditions. When combined with in situ measurements, aircraft data were used to validate the AMSR-E sea ice temperature and snow-depth products. The modeling studies helped interpret the field-data comparisons, provided insight on the limitations of the AMSR-E sea ice algorithms, and suggested potential improvements to the AMSR-E retrieval algorithms.

Cavalieri, Donald J.↗

Dynamic optical filtration

A dynamic optical filtration system and method effectively blocks bright light sources without impairing view of the remainder of the scene. A sensor measures light intensity and position so that selected cells of a shading matrix may interrupt the view of the bright light source by a receptor. A beamsplitter may be used so that the sensor may be located away from the receptor. The shading matrix may also be replaced by a digital micromirror device, which selectively sends image data to the receptor.

Chretien, Jean-Loup↗

A light intensity function suitable for multimode fiber-optic sensors

Intensity distribution functions on the image plane are derived under the assumption that a multimode optic fiber is illuminated by a light source which can be approximated by infinite uniangular beams carrying equal power. The application of the theory to a Lambertian source is discussed. Experimental results, based on the observation of the light intensity distribution imaged on an opaque screen and collected by a digital camera, are presented. The theoretical and experimental data are compared to verify that the intensity function is an accurate model for describing the realistic approach to sensor design. The limitations of the uniangular and uniform intensity distribution models are discussed on the basis of theoretical and experimental results.

He, Gang↗

Determination of the inflight OTF of orbital earth resources sensors

There are no author-identified significant results in this report. A technique has been investigated that is particularly applicable to evaluation of earth-orbiting multispectral sensors. In all programs employing such sensors, simultaneous underflight photography from aircraft is made during passes of the spacecraft. To evaluate the spacecraft imagery, the two sets of photographs are scanned and digitized with a microdensitometer. The data are then Fourier analyzed, and the spatial frequency spectra is calculated. The spatial frequencies in the underflight trace are scaled to those in the spacecraft trace, and the ratio of the spectra gives the in-flight optical transfer function (OTF) for the orbiting sensor. The method has been applied to an Apollo 9 frame and the sensor OTF has been calculated. The results are good enough to encourage use of the technique and to indicate the accuracies required of the various measurements involved in determining in-flight sensor OTF by this method. A technique for determining correct scan registration and scaling between the two sets of imagery and a promising approach to noise reduction, in the form of weighted averaging of OTF's, are discussed.

Slater, P. N.↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=about 15 orbits/day].

NEAR IR IMAGERY↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Ultra Low Power Imaging Systems Using CMOS Image Sensor Technology

The need for miniaturization in advanced science sensor systems has led to the development of a new image sensor technology, the active pixel image sensor (APS). The development of CMOS APS technology allows the integration of timing and control electronics, imaging detector arrays, signal chains and analog-to-digital conversion on a single integrated circuit. The impact on the imaging system is to reduce power by approximately 1000x over existing systems - from tens of watts to tens of milliwatts.

imaging↗

Guidance and navigation for automatic landing, rollout, and turnoff using MLS and magnetic cable sensors

This paper describes the navigation and guidance system developed for the TCV B-737, a Langley Field NASA research aircraft, and presents the results of an evaluation during final approach, landing, rollout and turnoff obtained through a nonlinear digital simulation. A Kalman filter (implemented in square root form) and a third order complementary filter were developed and compared for navigation. The Microwave Landing Systems (MLS) is used for all phases of the flight for navigation and guidance. In addition, for rollout and turnoff, a three coil sensor which detects the magnetic field induced by a buried wire in the runway (magnetic leader cable) is used. The outputs of the sensor are processed into measurements of position and heading deviation from the wire. The results show the concept to be both feasible and practical for commercial type aircraft terminal area control.

Pines, S.↗

Method and apparatus for holographic processing

A method and apparatus for holographically processing optical signals in a fiber-optic sensor system. In the present invention, holographic processors are utilized in various combinations with light sources, fiber-optic transmission means, sensors and detectors to provide low cost, compact, sensitive and accurate sensor systems. By means of the holographic processors of the present invention, the aforementioned sensor systems are used to monitor such physical parameters as temperature, pressure, flow-rate, and the like, and to provide output signal indications thereof that are compatible with digital receiving stations and immune to electro-magnetic interference, hazardous atmosphere, and the inimical effects of inadvertent intensity variation due to equipment vibration and the like. In one typical embodiment, a pair of holographic processors are employed in a color multiplex-demultiplex sensor system in which a first holographic processor is employed to color multiplex a sensor signal and a second holographic processor is employed to decode the color-multiplexed signal into a binary pattern that is then transmitted onto a set of photodetectors. In each of the embodiments of the invention disclosed, a unique geometrical orientation of a hologram is utilized to minimize spurious signal interference that would otherwise hamper or totally preclude the holographic processing.

Quick, William H.↗

Electronic simulation of a barometric pressure sensor for the meteorological monitor assembly

An analysis of the electronic simulation of barometric pressure used to self-test the counter electronics of the digital barometer is presented. The barometer is part of the Meteorological Monitor Assembly that supports navigation in deep space communication. The theory of operation of the digital barometer, the design details, and the verification procedure used with the barometric pressure simulator are presented.

Guiar, C. N.↗

Change of Exposure Time Mid-test in High Temperature DIC Measurement

Performing digital image correlation (DIC) at extreme temperatures has been greatly challenging due to the radiation which saturates the camera sensor. At such high temperatures, the light intensity emitted from an object is occasionally so powerful that the acquired images are overwhelmingly saturated. This induces data loss, potentially ruining the test, thus requiring the user to restart the test. For this reason, selection of an appropriate camera sensitivity plays a crucial role prior to beginning the test. Exposure time is a factor contributing to camera sensitivity and it is the easiest setting to manipulate during the test since it introduces minimal errors when comparing to other factors, especially in quasi-static tests. This paper examines the influence of changing exposure time mid-test on DIC measurement uncertainty. The investigation was conducted by rigid body motion experiments at room temperature and 1600 ◦C, respectively. Thereby, some recommendations are given to help DIC users assess their images at room temperature to extrapolate the exposure at extreme temperatures along with accompanying solutions to salvage data at high temperature.

Digital Image Correlation↗

Crop classification with a Landsat/radar sensor combination

A combined Landsat/radar approach to classification of remotely sensed data, with emphasis on crops, was undertaken. Radar data were obtained by microwave radar spectrometers over fields near Eudora, Kansas and Landsat image data were obtained for the same test site. After Landsat digital images were registered and test-cells extracted, a comparable set of radar image pixels were simulated to match the Landsat pixels. The combined data set is then used for classification, and the results are examined with the best combination of sensor variables identified. Finally, the usefulness of radar in a simulated cloud-cover situation is demonstrated. The major conclusion derived from this study is that the combination of radar/optical sensors is superior to either one alone.

Li, R. Y.↗

Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

The function of the infrared gas transducer used during extravehicular activity (EVA) in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires highly accurate CO2 sensing technology with performance beyond that presently in use on the International Space Station extravehicular mobility unit (EMU). Further, that accuracy needs to be provided over the full operating pressure range of the suit (3 to 25 psia). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode (LD) sensor based on infrared absorption spectroscopy is being developed for this purpose by Vista Photonics, Inc. Version 1.0 prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The prototypes were upgraded with more sophisticated communications and faster response times to version 2.0 and delivered to JSC in July 2012. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with an field-programmable gate array microcontroller architecture. Based on the results of the iterative instrument development, further prototype development and testing of instruments were performed leveraging the lessons learned where feasible. The present development extends and upgrades the earlier hardware for the advanced PLSS 2.5 prototypes for testing at JSC. The prototypes provide significantly enhanced accuracy for water vapor measurement and eliminate wavelength drift affecting the earlier versions. Various improvements to the electronics and gas sampling are currently being advanced including the companion development of engineering development units that will ultimately be capable of radiation tolerance. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

Wood, William R.↗