Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗

Planetary Instrument Definition and Development Program (PIDDP). Instrument for future planetary flight missions: A visible-infrared imaging spectrometer for planetary missions

The objective of this project is to develop and prove a small, light-weight, efficient imaging spectrometer design to cover the VIS/NIR spectral range for applications particularly but not exclusively to NASA inner solar system space missions. A design and a brassboard prototype will be developed and tested. Progress over the first year of this project includes design specification, optical design layout, grating specifications, infrared detector selection, and mechanical design. Mechanical and grating manufacturing drawings were begun. We developed an agreement in principle to cooperate with the German space group, DLR, to apply some of their electronics microminiaturization technology to this imaging spectrometer project, mostly or entirely at their expense. Funds from NASA for the second year of this effort have been received and the effort is on track. Release of funds for the third year of this award will be requested later this year in order to accelerate this work and bring it to a conclusion in time for new NASA missions considerations as well as to make effective use of the DLR contributions.

Mccord, Thomas B.↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scanning imaging absorption spectrometer for atmospheric chartography

The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY is an instrument which measures backscattered, reflected, and transmitted light from the earth's atmosphere and surface. SCIAMACHY has eight spectral channels which observe simultaneously the spectral region between 240 and 1700 nm and selected windows between 1940 and 2400 nm. Each spectral channel contains a grating and linear diode array detector. SCIAMACHY observes the atmosphere in nadir, limb, and solar and lunar occultation viewing geometries.

Burrows, John P.↗

The Active Sun Telescope Array

The concept of the Active Sun Telescope Array (ASTA) designed as a part of the NASA Orbiting Solar Laboratory is described together with the details of the ASTA instrument package. The ASTA, which will investigate the phenomenology of the solar chromosphere and the corona, consists of six EUV/XUV solar telescopes designed to provide wide field solar images in narrow wavelength bands, high-resolution spectroheliograms, and line profiles of the solar plasma in the temperature range from 10,000 K to 30,000 K. The detectors used in the ASTA are of the multianode multichannel array photon-counting array detector type.

Walker, Arthur B. C., Jr.↗

A Pair Production Telescope for Medium-Energy Gamma-Ray Polarimetry

We describe the science motivation and development of a pair production telescope for medium-energy (approximately 5-200 Mega electron Volts) gamma-ray polarimetry. Our instrument concept, the Advanced Energetic Pair Telescope (AdEPT), takes advantage of the Three-Dimensional Track Imager, a low-density gaseous time projection chamber, to achieve angular resolution within a factor of two of the pair production kinematics limit (approximately 0.6 deg at 70 Mega electron Volts), continuum sensitivity comparable with the Fermi-LAT front detector (is less than 3 x 10(exp -6) Mega electron Volts per square centimeter per second at 70 Mega electron Volts), and minimum detectable polarization less than 10% for a 10 milliCrab source in 10(exp 6) s.

Gamma rays↗

Measurement Approach and Design of the CubeSat Infrared Atmospheric Sounder (CIRAS)

The CubeSat Infrared Atmospheric Sounder (CIRAS) will measure upwelling infrared radiation of the Earth in the MWIR region of the spectrum from space on a CubeSat. The observed radiances can be assimilated into weather forecast models and be used to retrieve lower tropospheric temperature and water vapor for climate studies. Multiple units can be flown to improve temporal coverage or in formation to provide new data products including 3D motion vector winds. CIRAS incorporates key new instrument technologies including a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The detectors are hybridized to a commercial ROIC and commercial camera electronics. The second key technology is an MWIR Grating Spectrometer (MGS) designed to provide imaging spectroscopy for atmospheric sounding in a CubeSat volume. The MGS has no moving parts and includes an immersion grating to reduce the volume and reduce distortion. The third key technology is an infrared blackbody fabricated with black silicon to have very high emissivity in a flat plate construction. JPL will also develop the mechanical, electronic and thermal subsystems for CIRAS, while the spacecraft will be a commercially available CubeSat. The integrated system will be a complete 6U CubeSat capable of measuring temperature and water vapor profiles with good lower tropospheric sensitivity. The CIRAS is the first step towards the development of an Earth Observation Nanosatellite Infrared (EON-IR) capable of meeting the replacement needs of the CrIS on JPSS.

Pagano, Thomas S.↗

Infrared technology XVII; Proceedings of the Meeting, San Diego, CA, July 22-26, 1991

Recent advances in IR technologies and their application to all types of IR systems are reported focusing on the JPL Space Infrared Telescope Facility (SIRTF), JPL instruments and systems for observation of earth and the atmosphere, staring arrays and thermal imaging, ten-year updates of IR techniques, infrared in the USSR, simulation and testing, focal-plane and optical technologies, and military and scientific applications. Particular attention is given to SIRTF stray light analysis, SIRTF focal-plane technologies, long-wave IR detectors based on III-V materials, IR lidars for atmospheric remote sensing, a firefly system concept, a high-fill-factor monolithic IR image sensor, atmospheric laser-transmission tables simply generated, ORION semiconductor optical detectors, postprocessing of thermograms in IR nondestructive testing, evaluation of the IR signature of dynamic air targets, the current status of InGaAs detector arrays for 1-3 microns, a dual-band optical system for IR multicolor signal processing, and blackbody radiators for field calibration.

Andresen, Bjorn F.↗

Diurnal Lightning Distributions as Observed by the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS)

Data obtained from the OTD (April 1995 to March 2000) and LIS (December 1997 to December 2005) satellites (70 and 35 degree inclination low earth orbits, respectively) are used to statistically determine the number of flashes in the diurnal cycle both as a function of local and universal time. Also included are global flash density maps. The data are further subdivided by season, continental versus oceanic, night time versus day time, northern versus southern hemisphere, and other regions of interest. The data include corrections for detection efficiency and instrument view time. The data are compared with both the "Carnegie Curve" and the diurnal global thunderstorm contributions from thunderday statistics from different continents, and are found to agree closely in phase and amplitude with the global thunderday statistics. The analysis also indicates that the southern hemisphere spring (September to November) has larger amplitude than the southern hemisphere fall (March to May). This may be due to differences in the contribution from the Brazilian rain forest during these periods. In general, as highlighted by a difference analysis, more lightning is observed in local springtime than the fall for continental locations, while oceanic regions display an opposite effect. For some areas of the world, the peak of diurnal curve appears to be shifted to later in the evening.

Bailey, Jeff C.↗

Flight Integral Field Spectrograph (IFS) Optical Design for WFIRST Coronagraphic Exoplanet Demonstration

Based on the experience from Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST, we have moved to the flight instrument design phase. The specifications for flight IFS have similarities and differences from the prototype. This paper starts with the science and system requirement, discusses a number of critical trade-offs: such as IFS type selection, lenslet array shape and layout versus detector pixel accuracy, how to accommodate the larger Field Of View (FOV) and wider wavelength band for a potential add-on StarShade occulter. Finally, the traditional geometric optical design is also investigated and traded: reflective versus refractive, telecentric versus non-telecentric relay. The relay before the lenslet array controls the chief angle distribution on the lenslet array. Our previous paper has addressed how the relay design combined with lenslet arraypinhole mask can further compress the residual star light and increase the contrast. Finally, a complete phase A IFS optical design is presented.

Integral Field spectrograph↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Artificial Intelligence for imaging Cherenkov detectors at the EIC

Abstract Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in the hadron endcap, a Detector for Internally Reflected Cherenkov (DIRC) light in the barrel, and a modular RICH (mRICH) in the electron endcap. These detectors involve optical processes with many photons that need to be tracked through complex surfaces at the simulation level, while for reconstruction they rely on pattern recognition of ring images. This proceeding summarizes ongoing efforts and possible applications of AI for imaging Cherenkov detectors at EIC. In particular we will provide the example of the dRICH for the AI-assisted design and of the DIRC for simulation and particle identification from complex patterns and discuss possible advantages of using AI.

Instruments & Instrumentation↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Lockheed diode array magnetograph

A new magnetograph using a solid state monolithic linear silicon diode array has been constructed at Lockheed Solar Observatory. This magnetograph uses a digital image processor, and makes data available both in digital and analog form. The diode array detector is capable of a signal-to-noise ratio of 2000:1 or better when cooled to a temperature of -40 deg centigrade. Thus, intensity differences of the order of one part in a thousand may easily be detected without signal averaging. This instrument may be considered a prototype for an instrument using a two-dimensional array. The magnetograph is now fully operational, and is being used to produce data for statistical studies of solar magnetic field diffusion.

Smithson, R. C.↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗