Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The GATE Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.

60 APPLIED LIFE SCIENCES↗

Streamlined Monte Carlo simulation of environmental gamma-ray backgrounds for radiation detector sensitivity comparisons

In a recent effort to compare the detection sensitivity of a variety of gamma radiation detectors applied to in-situ and lightly shielded field laboratory scenarios, the authors found that a lack of “apples-to-apples” background measurements with the different detectors presented significant challenges in the detection sensitivity calculations. To overcome this hurdle, Monte Carlo modeling of the terrestrial environmental gamma radiation and experimental measurements were undertaken. Inspired by the work of Vojtyla to reduce the computing burden of modeling bremsstrahlung emitted from the surface of lead, a related approach was taken to define a gamma-ray surface source that would adequately represent the emission of natural gamma-rays from the earth’s surface. This work will present the definition of a surface source that is based on the potassium, uranium, and thorium content of a local soil, and provide a comparison to experimental in-situ gamma measurements.

Keillor, Martin E.↗

Monte Carlo Analysis of Coolant Stream Impurity Gamma Emissions in Gas-Cooled Fast Reactors

It is well established that a rapid increase in the concentration of fission products in the reactor coolant stream can serve as an early indication of fuel failure. We use Monte Carlo simulations to investigate the feasibility of using several gamma detectors as diagnostic equipment to monitor the presence of major fission product isotopes in high-temperature gas-cooled reactor (HTGR) coolant streams for early detection of fuel failure and therefore the prevention of fuel failure conditions. Herein we model the response of high-purity germanium (HPGe), CdZnTe, NaI(Tl), and LaBr 3 (Ce) detectors of typical commercial sizes to the gamma emissions from nuclides expected to be found within the coolant stream of the Versatile Test Reactor (VTR) under development by the U.S. Department of Energy. The results indicate that for the 233- and 250-keV gamma rays from 133 Xe and 135 Xe, respectively, the 3σ detection criterion is met in under 1 min using a single HPGe detector. Changes in other spectral lines associated with Xe nuclides are detected within 1 h regardless of the choice of detector.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DUNE: Michel Electron Selection with SPINE

This poster details the evaluation of a Michel electron selection algorithm centered on the neural network-based software SPINE (Scalable Particle Imageing with Neural Embeddings). The algorithm was developed and calibrated using simulated data from the SBND (Short-Baseline Neutrino Detector) experiment before being applied to simulated data from DUNE (Deep Underground Neutrino Experiment).

Wilson, Dante [U. Colorado, Boulder]↗

Software Trigger Algorithms to Search for Magnetic Monopoles with the NO$\nu$A Far Detector

The NOvA far detector, due to its surface proximity, large size, good timing resolution, large energy dynamic range, and continuous readout, is sensitive to the detection of magnetic monopoles over a large range of velocities and masses. In order to record candidate magnetic monopole events with high efficiency we have designed a software-based trigger to make decisions based on the data recorded by the detector. The decisions must be fast, have high efficiency, and a large rejection factor for the over 100,000 cosmic rays that course through the detector every second. In this paper we briefly describe the simulation of magnetic monopoles, including the detector response, and then discuss the algorithms applied to identify magnetic monopole candidates. We also present the results of trigger efficiency and purity tests using simulated samples of magnetic monopoles with overlaid cosmic backgrounds and electronic noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACHILLES-GENIE Interface for Neutrino Simulations, ADRIANO2 Tile Prototype for High-Granularity Dual-Readout Calorimetry

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.]↗

Optimization using pathwise algorithmic derivatives of electromagnetic shower simulations

Among the well-known methods to approximate derivatives of expectancies computed by Monte-Carlo simulations, averages of pathwise derivatives are often the easiest one to apply. Computing them via algorithmic differentiation typically does not require major manual analysis and rewriting of the code, even for very complex programs like simulations of particle-detector interactions in high-energy physics. However, the pathwise derivative estimator can be biased if there are discontinuities in the program, which may diminish its value for applications. This work integrates algorithmic differentiation into the electromagnetic shower simulation code HepEmShow based on G4HepEm, allowing us to study how well pathwise derivatives approximate derivatives of energy depositions in a sampling calorimeter with respect to parameters of the beam and geometry. We found that when multiple scattering is disabled in the simulation, means of pathwise derivatives converge quickly to their expected values, and these are close to the actual derivatives of the energy deposition. Additionally, we demonstrate the applicability of this novel gradient estimator for stochastic gradient-based optimization in a model example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of the Neutrino-4 experiment

Monte Carlo simulation of the two-section reactor antineutrino detector of the Neutrino-4 experiment is carried out. The scintillation-type detector is based on the inverse beta-decay reaction. The antineutrino is recorded by two successive signals from the positron and the neutron. The simulation of the detector sections and the active shielding is performed. As a result of the simulation, the distributions of photomultiplier signals from the positron and the neutron are obtained. The efficiency of the detector depending on the signal recording thresholds is calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DetSuM: Detector Surrogate Model for LArTPC

In large neutrino experiments such as the Deep Underground Neutrino Experiment (DUNE), estimating detector response uncertainties typically requires simulation samples that consume substantial computing resources and time. To mitigate this challenge, we present DetSuM, an uncertainty-aware surrogate model designed to capture the detector response variations with reduced computing load compared to full simulations. This poster describes the construction and evaluation of DetSuM using simulation and reconstruction datasets in a rare-event search at DUNE. We assess DetSuM's ability to predict key detector-response variations and their associated uncertainties, discuss current limitations, and outline improvements to extend its validity in systematics studies of DUNE physics.

Li, Aobo [UC, San Diego]↗

Simulation of the reconstruction of distorted digital data

Results of simulation runs obtained while varying detector sampling rates and threshold levels for a 20,000 foot equalized cable and a bit rate of 1 Mbs are given. The simulation techniques appear useful for preliminary design of detector levels and sampling rates and for analyzing sensitivity of detector performance as system transfer function parameters are varied.

Zobrist, G. W.↗

Imaging Calorimeter for ACCESS Simulations with GEANT/FLUKA

Imaging Calorimeter for ACCESS (ICA) is a candidate of the calorimeter for the NASA's ACCESS program. The ICA studies the origin and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays in the energy up to 10(exp 16) eV. For the past year, Monte Carlo simulation study for the ICA has been conducted to predict the detector performance and to design the system for match the scientific objectives. Simulation results show that the detector response resembles a Gaussian distribution and the energy resolution with ICA can be achieved about 40%. In addition, simulations of the detector's response to an assumed bent power law spectra in the region where the knee occurs have been conducted and clearly show that this detector can provide sufficiently accurate estimates of the spectral parameters that are a science goal of ACCESS.

Lee, Jeongin↗

1 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_eta0_b0

Particle gun for detector studies: A particle gun for single pions and deutrons. The eta and phi is set to 0. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. The momenta and the particle ID is given in the file name. The full Geant simulation is performed assuming no magnetic field (B=0). The sample is designed for timing studies. Each file has 50k events (only 1 TeV sample will have 10k events). Comment on full simulation: While the baseline detector is SiFcc-7, the B-field for rfull009 tag was set to 0. The sample was designed for calorimeter studies, and we expect that the charged particles entering the calorimeter have exactly eta=phi=0. The sample is designed for timing studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗