At least 667 records · Page 37

Bayesian inference of electron density and ion temperature profiles from neutral beam and halo Balmer- α emission at Wendelstein 7-X

By employing Bayesian inference techniques, the full electron density profile from the plasma core to the edge of Wendelstein 7-X (W7-X) is inferred solely from neutral hydrogen beam and halo Balmer- α (H α ) emission data. The halo is a cloud of neutrals forming in the vicinity of the injected neutral beam due to multiple charge exchange reactions. W7-X is equipped with several neutral hydrogen beam heating sources and an H α spectroscopy system that views these sources from different angles and penetration depths in the plasma. As the beam and halo emission form complex spectra for each spatial point that are non-linearly dependent on the plasma density profile and other parameters, a complete model from the neutral beam injection and halo formation through to the spectroscopic measurements is required. The model is used here to infer electron density profiles for a range of common W7-X plasma scenarios. The inferred profiles show good agreement with profiles determined by the Thomson scattering and interferometry diagnostics across a broad range of absolute densities without any changes to the input or fitting parameters. The time evolution of the density profile in a discharge with continuous core density peaking is successfully reconstructed, demonstrating sufficient spatial resolution to infer strongly shaped profiles. Furthermore, it is shown as a proof of concept that the model is also able to infer the main ion temperature profile using the same data set.

forward modeling↗

Model test on underground coal gasification (UCG) with low-pressure fire seepage push-through. Part I: Test conditions and air fire seepage

The technology of a pushing-through gallery with oxygen-enriched fire-seepage combustion was studied during shaft-free UCG in this article, and the main experiment parameters were probed. The test results were analyzed in depth. The patterns of variation and development were pointed out for the fire source moving speed, temperature field, leakage rate, the expanding diameter for the gasification gallery, and blasting pressure. Test results showed that, with the increase in the wind-blasting volume, the moving velocity for the fire source speeded up, and the average temperature for the gallery continuously rose. Under the condition of oxygen-enriched air blasting, when O{sub 2} contents stood at 90%, the moving speed for the fire source was 4-5 times that of air blasting. In the push-through process, the average leakage rate for the blasting was 82.23%, with the average discharge volume of 3.43 m{sup 3}/h and average gallery diameter of 7.87 cm. With the proceeding of firepower seepage, the extent of dropping for the leakage rate increased rapidly, and the drop rate for the blasting pressure gradually heightened.

01 COAL, LIGNITE, AND PEAT↗

Venusian sinuous rilles

After a preliminary assessment of venusian channels, it now seems to be clear that the channels have distinctive classes, which imply a wide range of formation parameters and formation mechanisms. They include outflow channels mainly formed by mechanical erosion from very high discharge flow, and canali-type channels requiring either constructional process or mechanical erosion by rather exotic low-viscosity lava such as carbonatite or sulfur. Here we focus on venusian sinuous rilles. Venusian sinuous rilles are generally simple, and originate from a collapsed source. They are shallow and narrow downstream. The venusian sinuous rilles are distinct from canali-type channels, which exhibit almost constant morphologies throughout their entire length, and from outflow channels, which are characterized by wide anastomosing reaches. The lunar sinuous rilles could have been formed initially as constructional channels. However, incision was caused by the long flow duration and high temperatures of eruption, along with relatively large discharge rates, possibly assisted by a low viscosity of the channel-forming lava. Channel narrowing and levee formation suggest relatively fast cooling. The venusian channels could have had a similar sequence of formation including rapid cooling. Assuming the substrate is typical tholeiitic lava, the flowing lavas' temperatures have to be higher than the melting temperature of the substrate. The flow should have a low viscosity to cause turbulence and keep a high Reynolds number to sustain efficient thermal erosion. Determining eruption conditions also provide insights to estimate lava composition. Assuming a channel is formed mostly by thermal erosion, the channel's length and longitudinal profile are functions of lava properties. The depth profiles of the channel are measured by radar foreshortening methods and stereo images. Eruption conditions of channel forming lava can be estimated by the methods developed by Hulme.

Komatsu, G.↗

Characterization of Tank 11H Samples from Tank Closure Cesium Removal 1A (TCCR 1A) Batch 1

Savannah River Mission Completion (SRMC) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. The TCCR 1A unit processes dissolved salt fed from Tank 10H through a series of ion exchange columns containing crystalline silicotitanate (CST, IONSIV TM R9120-B, 30x60) and the effluent is then discharged to Tank 11H. In support of the TCCR 1A program, SRNL analyzed samples taken from Tank 11H (without tank mixing) before, during, and at the completion of TCCR 1A Batch 1 processing. Tank 11H serves as the receipt tank for the filtered and cesium removed product from the TCCR 1A system. Processing of Batch 1 commenced on January 13, 2022 and completed on February 17, 2022, after processing approximately 70,100 gallons. A pre-production sample was collected from the heel remaining in Tank 11H just before Batch 1 processing began. In addition, five interim surface samples were collected from Tank 11H during processing, and both a surface and a variable depth sample (VDS, ~7” from tank bottom) were collected just after processing completed. Analysis of all samples included density and gamma spectroscopy, in addition to a more comprehensive suite of analytes for the pre- and post-production samples. The density of the pre-production sample was the highest of all samples measured and was then observed to decrease for the first two interim samples, followed by becoming fairly consistent for the remainder of the samples (~1.3 g/mL). The density of 1.3 g/mL is similar to the density measured for one of the three Tank 10H qualification samples (HTF-10-21-126). The 137 Cs activity was found to decrease as additional decontaminated effluent from the TCCR columns was added to Tank 11H during processing; however, an increase in activity was observed during periods of no processing which can be attributed to leaching of 137 Cs from the known solids in Tank 11H. The Cs isotope concentrations in the Tank 11H postproduction surface sample were determined to be 99.7-99.8% lower than the concentrations measured in the Tank 10H feed as measured by mass spectrometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Edge radial electric field structure and its connections to H-mode confinement in Alcator C-Mod plasmas

High-resolution charge-exchange recombination spectroscopic measurements of B{sup 5+} ions have enabled the first spatially resolved calculations of the radial electric field (E{sub r}) in the Alcator C-Mod pedestal region [E. S. Marmar, Fusion Sci. Technol. 51, 261 (2006)]. These observations offer new challenges for theory and simulation and provide for important comparisons with other devices. Qualitatively, the field structure observed on C-Mod is similar to that on other tokamaks. However, the narrow high-confinement mode (H-mode) E{sub r} well widths (5 mm) observed on C-Mod suggest a scaling with machine size, while the observed depths (up to 300 kV/m) are unprecedented. Due to the strong ion-electron thermal coupling in the C-Mod pedestal, it is possible to infer information about the main ion population in this region. The results indicate that in H-mode the main ion pressure gradient is the dominant contributor to the E{sub r} well and that the main ions have significant edge flow. C-Mod H-mode data show a clear correlation between deeper E{sub r} wells, higher confinement plasmas, and higher electron temperature pedestal heights. However, improved L-mode (I-mode) plasmas exhibit energy confinement equivalent to that observed in similar H-mode discharges, but with significantly shallower E{sub r} wells. I-mode plasmas are characterized by H-mode-like energy barriers, but with L-mode-like particle barriers. The decoupling of energy and particle barrier formation makes the I-mode an interesting regime for fusion research and provides for a low collisionality pedestal without edge localized modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sources of methane to an Arctic lake in Alaska: An isotopic investigation

Sources of dissolved methane (CH 4 ) at Toolik Lake, Alaska, include both diffusion from lake sediments and groundwater entering the lake from its perimeter. Here we use hydrogen and oxygen isotopes in water (H 2 O), carbon and hydrogen isotopes in CH 4 , and carbon isotopes in dissolved inorganic carbon (DIC) to calculate the relative importance of lake sediment and groundwater discharge as sources of dissolved CH 4 to Toolik Lake. We also resolve the relative importance of the source contribution spatially within the lake and determine the processes controlling CH 4 concentrations in groundwater surrounding the lake. Our findings, from a mixing model based on isotopes in CH 4 , suggest that groundwater is a more important source of CH 4 at the perimeter of the lake where the water-to-air flux is high. In addition, we find on the local scale that high groundwater methane concentrations may be better linked to areas around the lake where rain is the dominant source of water to the active layer, indicating that changes in precipitation and active layer thaw depth will impact methane concentrations in the active layer and, ultimately, the groundwater associated flux to Toolik Lake.

54 ENVIRONMENTAL SCIENCES↗

Effective Electrochemical Charge Storage in the High-Lithium Compound Li8ZrO6

Li8ZrO6 is a pseudolamellar compound with high lithium content. Even though it is intrinsically a poor conductor and does not contain a transition metal with easily variable oxidation states, a new synthetic approach to preparing it in nanocomposite form with intimate contact to a conductive carbon by mechanical delamination enabled galvanostatic cycling of coin half-cells containing Li8ZrO6/C as the cathode and Li-metal as the anode at 221 mAh/g (which corresponds to extracting 2 Li per formula unit) over at least 140 cycles. With a higher capacity limit, a discharge capacity of 331 mAh/g (which corresponds to extracting 3 Li per formula unit) was maintained over 15–20 cycles. Ex-situ and operando X-ray diffraction (XRD) studies of galvanostatically cycled cells showed that at these levels of charge, delithiation follows a reversible, topotactic path with only small distortions around Zr atoms. During this process, crystalline grain sizes decrease continuously, shortening diffusion lengths within grains but increasing the number of grain boundaries and electrode/electrolyte interfaces. Charge storage in Li8ZrO6 appears to involve partial oxidation of oxygen atoms and production of small-polaron holes, as supported by XRD, X-ray photoelectron spectroscopy, and pair-distribution function studies and predicted by quantum mechanical calculations. At higher depths of charge, delithiation results in amorphization of the active electrode material. The charge storage mechanism in Li8ZrO6 is unusual among lithium-ion battery electrode materials and involves a combination of mechanisms that resemble intercalation and conversion reactions. With further refinement, Li8ZrO6/C based materials open up opportunities to develop new cathode materials for lithium-ion batteries that may improve on currently existing capacity barriers.

Li diffusion↗

Validation of Carbon Flux and Related Products for SIMBIOS: The CARIACO Continental Margin Time Series and the Orinoco River Plume

Between 1997 and 2000, this Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) investigation collected bio-optical measurements in the Southeastern Caribbean Sea and the tropical western Atlantic to help understand the color of coastal and continental shelf waters. Specifically, bio-optical data were collected to complement an oceanographic time series maintained within the Cariaco Basin, a site affected by seasonal coastal upwelling. Bio-optical data were also collected within the plume of the Orinoco River during seasonal extremes in discharge. This program focused on providing data to the Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) and SIMBIOS Projects for validating SeaWiFS products. The data are unique in that they provide a substantial number of observations on repeated seasonal cycles for the SeaWIFS Bio-Optical Archive and Storage System (SeaBASS) bio-optical database. An important aspect of this SIMBIOS investigation was a focus on proper interpretation of ocean color remote sensing data from coastal and continental shelf environments. With this goal in mind, ocean color satellite data from a variety and locations and from different satellite sensors were examined to understand spatial and temporal variability in pigment concentrations, and also to conduct an in-depth study of current atmospheric correction and bio-optical algorithms.

Muller-Karger, Frank↗

Soil Interim Measures Implementation Report Q6 Radar Station – Solid Waste Management Unit 112 Locations of Concern 3 and 10 Kennedy Space Center, Florida

This report presents a summary of the soil interim measures (IM) implementation activities that occurred from January 23 through June 6, 2023, at the Q6 Radar Station (Q6RS) Solid Waste Management Unit (SWMU) 112, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at 10 Q6RS Locations of Concern (LOCs), identified during a SWMU assessment in 2013 (NASA 2013). Since the SWMU assessment, further confirmatory sampling and assessment was conducted for each LOC, and based on the data collected during these assessments, it was determined that Resource Conservation and Recovery Act Facility Investigation to further evaluate soil and groundwater was to be conducted at two LOCs: LOC 1 – Former Underground Storage Tanks (groundwater) and LOC 3 – Radar Antenna Refurbishment Area (soil). The LOC 1 groundwater assessment is ongoing, and the results will be presented under a separate cover. It was also determined that soil IM would be completed at two of the LOCs, LOC 3 and LOC 10 – Compressor Building Condensate Discharge. A Soil IM Work Plan was prepared and submitted in October 2021 (NASA 2021). The plan proposed excavation and disposal of barium and copper impacted soil in the LOC 3 and 10 areas. This report presents a summary and results of the soil IM implementation activities conducted at LOCs 3 and 10. The site contaminates of concern for this soil IM are barium and copper. The activities presented in this report includes soil IM implementation and groundwater sampling. From January 23 through March 24, 2023, AECOM Technical Services, Inc. (AECOM) field personnel conducted IM implementation activities in the LOC 3 and 10 areas. As presented in the IM Work Plan, shallow soils, impacted with metals, were excavated to a depth of 2 feet below land surface in the central area of the site around the radar antenna and associated equipment. AECOM personnel excavated 77.43 tons of soil using hand tools and, when able, heavy equipment. The soils were placed into lined roll-off containers, which were covered and transported under manifest to the Cedar Trail Landfill in Bartow, Florida. The site was restored to original condition using certified clean backfill material (sand), with filter fabric, and gravel. Areas outside of the excavation were restored with grass seed. On June 6, 2023, AECOM field personnel conducted groundwater sampling activities within the soil IM excavation area. AECOM personnel collected one groundwater sample from monitoring well Q6RS-MW0003. The sample was submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 6020B for metals (barium and copper). Barium and copper were detected at 18 micrograms per liter (µg/L) and 14 µg/L, respectively, and were below the State of Florida Groundwater Cleanup Target Levels (GCTLs) for barium at 2,000 µg/L and copper at 1,000 µg/L.

Chadwick Sloan Lee↗

A Proposal for an Integrated Geophysical Strategy to "Follow the Water" on Mars

The search for subsurface water has become a primary focus of Mars exploration. Its abundance and distribution (both as ground ice and groundwater) have important implications for understanding the geologic, hydrologic, and climatic evolution of the planet; the potential origin and continued survival of life; and the accessibility of a critical in situ resource for sustaining future human explorers. For these reasons, a principal goal of the Mars science, astrobiology, and the HEDS programs is to determine the 3-D distribution and state of subsurface H2O, at a resolution sufficient to permit reaching any desired volatile target by drilling. The three targets most often discussed are: groundwater, massive deposits of near-surface ground ice (associated with the ponded discharge of the outflow channels or the relic of a former ocean), and ice-saturated frozen ground. Based on the present best estimates of mean annual surface temperature, crustal thermal conductivity, geothermal heat flow, and groundwater freezing temperature, the mean thickness of frozen ground on Mars is expected to vary from approx. = 2.5 - 5 km at the equator to approx. = 6.5 - 13 km at the poles. However, natural variations in both crustal heat flow and thermal conductivity are likely to result in significant local departures from these predicted values. The recent discovery of "young" fluvial-like features, emanating from the slopes of local scarps, raises the possibility that liquid water may also exist episodically at shallow (approx. = 100 - 500 m) depth; however, the true nature and absolute age of these features remains highly uncertain. Although the belief that Mars is water-rich is supported by a wide variety geologic evidence, our ignorance about the heterogeneous nature and thermal evolution of the planet's crust effectively precludes geomorphic or theoretical attempts to quantitatively assess the current geographic and subsurface vertical distribution of ground ice and groundwater . For this reason, any exploration activity (such as drilling) whose success is contingent on the presence of subsurface water, must be preceded by a comprehensive high-resolution geophysical survey capable of assessing whether local reservoirs of water and ice actually exist. Terrestrial experience has demonstrated that the accurate identification of such targets is likely to require the application of multiple geophysical techniques. In this abstract we propose an integrated strategy for the geophysical exploration of Mars that we believe represents the fastest, most cost-effect, and technically capable approach to identifying the state and distribution of subsurface water. Additional information is contained in the original extended abstract.

Clifford, S. M.↗

Factors influencing charge capacity of vanadium pentoxide thin films during lithium ion intercalation/deintercalation cycles

The intercalation of vanadium pentoxide by lithium ions leads to a change in optical properties, a process that is of value in thin-film electrochromic devices. In this study, films of V{sub 2}O{sub 5}, deposited on indium tin oxide (ITO) glass coupons by a sol-gel process, were challenged by increasing numbers of charge-discharge cycles ranging from 72 to 589 full cycles. The samples were characterized by x-ray photoelectron spectroscopy (XPS) and then examined in the deintercalated state by time-of-flight secondary ion mass spectroscopy (SIMS). XPS enabled measurement of the thickness and composition of the solid-electrolyte interface and provided evidence of the residual V{sup 4+} concentration within the top few nanometers of the surface. The SIMS profile gave direct information on the thickness of the films and on the thickness loss caused by rinsing the samples after the electrochemical exposure. Determination, by SIMS, of the concentration of lithium ions has enabled a correction to be made for the amount of inactive material within the electrochemically active region of the film. The SIMS depth profiles for lithium in the four samples are similar, with a marked buildup of Li at the interface with the ITO. This interphase zone had a thickness of {approx}27 nm and was electrochemically inactive, enabling a further correction to be made. Thus, by means of the XPS and the SIMS results the chemistry and thickness of the films could be fully characterized. The remaining inconsistency between capacity (between 35% and 100% of the anticipated charge) and number of cycles is ascribed to edge effects arising from the method used for production of the coupons.

36 MATERIALS SCIENCE↗

The Greening of a Plutonium Facility through Personnel Safety, Operational Efficiency, and Infrastructure Improvements - 12108

Chemical and metallurgical operations involving plutonium and other hazardous materials account for most activities performed at the Los Alamos National Laboratory's Plutonium Facility (TA-55). Engineered barriers provide the most effective protection from hazardous materials. These safety features serve to protect workers and provide defense in depth against the hazards associated with operations. Although not designed to specifically meet environmental requirements the safety-based design does meet or exceed the requirements of the environmental regulations enacted during and since its construction. TA-55's Waste Services Group supports this safety methodology by ensuring safe, efficient and compliant management of all radioactive and hazardous wastes generated at the TA-55. A key function of this group is the implementation of measures that lower the overall risk of radiological and hazardous material operations. Processes and procedures that reduce waste generation compared to current, prevalent processes or procedures used for the same purpose are identified. Some of these 'Best Practices' include implementation of a chemical control system, elimination of aerosol cans, reduction in hazardous waste, implementation of zero liquid discharge, and the re-cyclization of nitric acid. P2/WMin opportunities have been implemented in the areas of personnel and facility attributes, environmental compliance, energy conservation, and green focused infrastructure expansion with the overall objective of minimizing raw material and energy consumption and waste generation. This increases technical knowledge and augments operational safety. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Integrated Hydrological Model for Long-Term Monitoring in Tims Branch Watershed, SC - 19435

The Tims Branch watershed in Savannah River Site (SRS), South Carolina is a small-scale watershed that has been impacted by contaminated runoff and discharge wastewater from nuclear research facilities located within the watershed over the past century. Innovative remediation technologies, such as tin injection and pump and treat, have been implemented to remove heavy metals and volatile organic compounds (VOCs) from the watershed. Today, the Tims Branch watershed serves as a test-bed for monitoring the performance of remediation activities. This study describes the development of the two-dimensional integrated surface water/groundwater model for Tims Branch watershed to assess the impact of cleanup activities on hydrological processes in this watershed. This model will serve as a tool to simulate the effect of climatic events on overland flow distribution and further on will be used to assess contaminant transport. This paper illustrates the application of the developed model for simulation of overland flow depth and velocity in Tims Branch watershed and streamflow in A-014 outfall tributary. The watershed includes the second order Tims Branch stream, several outfalls, and a network of tributaries. Simulation of non-calibrated overland flow was conducted for the years 2016 using available stream flow data within the watershed. Recent flow data from a newly deployed stage gauge was also used to assess the model results. The results show the model ability to simulate overland flow and stream flow and can be used as a tool to represent the hydrological conditions in the Tims Branch watershed. The results of this model simulation will be further used to develop contaminant transport model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle-in-cell Monte Carlo-collision modeling of non-ideal effects in wave-heated dense microplasmas

A computational model for non-ideal plasma effects during the time evolution of a second-stage laser-heated discharge at high pressures is presented. The model extends a classical one-dimensional particle-in-cell Monte Carlo-collision (PIC-MCC) approach coupled with Maxwell's equations for the laser-heating process of a xenon plasma at 300 K temperature and 10–100 bar pressure. Plasma non-ideality resulting from Coulomb coupling at high plasma densities is manifested as a depression in the effective ionization potential of atoms and enhanced collision cross sections. These non-ideal effects are represented using the Ecker–Kröll model in the context of the PIC-MCC approach. We find that full ionization of the plasma is obtained on the picosecond timescale, starting from the skin layer and quickly expanding throughout the domain through an anomalous extension of the skin depth. More critically, we show that the inclusion of the non-ideal plasma effects results in more rapid ionization compared to an ideal plasma, especially at higher pressures. The ionization delay reduction is of the order of a fraction of a picosecond, corresponding to a 16% decrease at 100 bar. As the amplitude of the wave field is lowered, the ionization rate is lowered, making the plasma non-ideality effects more prominent.

Solmaz, Evrim (ORCID:0000000211830881)↗

Injected mass deposition thresholds for lithium granule instigated triggering of edge localized modes on EAST

The ability of an injected lithium granule to promptly trigger an edge localized mode (ELM) has been established in multiple experiments. By horizontally injecting granules ranging in diameter from 200 microns to 1mm in diameter into the low field side of EAST H-mode discharges we have determined that granules with diameter > 600 microns are successful in triggering ELMs more than 95% of the time. Granules were radially injected from the outer midplane with velocities ~ 80 m/s into EAST upper-single null discharges with an ITER like tungsten monoblock divertor. ELM triggering was a prompt response to granule injection, and for granules of a sufficient size there was no evidence of a "trigger lag" phenomenon as observed in full metal machines. We also demonstrated that the triggering efficiency decreased with granule size during dynamic size scans. These granules were individually tracked throughout their injection cycle in order to determine their efficacy at triggering an ELM. Furthermore, by simulating the granule injection with an experimentally benchmarked neutral gas shielding (NGS) model, the ablatant mass deposition required to promptly trigger an ELM is calculated and the fractional mass deposition is determined. Simulated 900 micron granules capable of triggering an ELM show a peaked mass deposition of 3.9 x 10 17 atoms per mm of penetration at a depth of approximately 5 cm past the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bedrock weathering rates, reactive nitrogen influxes and effluxes, and nitrous oxide emissions rates from the Pumphouse Hillslope, East River Watershed, Colorado

Atmospheric nitrous oxide contributes directly to global warming, yet models of the nitrogen cycle do not account for bedrock, the largest pool of terrestrial nitrogen, as a source of nitrous oxide. Although it is known that release rates of nitrogen from bedrock are large, there is an incomplete understanding of the connection between bedrock-hosted nitrogen and atmospheric nitrous oxide. Here, we quantify nitrogen fluxes and mass balances at a hillslope underlain by marine shale. We found that at this site bedrock weathering contributes 78% of the subsurface reactive nitrogen, while atmospheric sources (commonly regarded as the sole sources of reactive nitrogen in pristine environments) account for only the remaining 22%. About 56% of the total subsurface reactive nitrogen denitrifies, including 14% emitted as nitrous oxide. The remaining reactive nitrogen discharges in porewaters to a floodplain where additional denitrification likely occurs. We also found that the release of bedrock nitrogen occurs primarily within the zone of the seasonally fluctuating water table and suggest that the accumulation of nitrate in the vadoes zone, often attributed to fertilization and soil leaching, may also include contributions from weathered nitrogen-rich bedrock. Our hillslope study suggests that under oxygenated and moisture-rich conditions, weathering of deep, nitrogen-rich bedrock makes an important contribution to the nitrogen cycle. The data files are in Excel, which can be accessed using Microsoft Office, and consist of many data sets from the Pumphouse Hillslope PLM (Pumphouse Lower Montane) 1, 2, 3, and 4. They include soil to rock (0-10 meters) solid phase minerals and elements compositions; time- and depth-resolved pore-water chemistry and pore-gas compositions; time- and depth-resolved water table depths and water fluxes; subsurface weathering rates; nitrogen influxes and effluxes and mass balance. The attached paper is in a Word document, which can be accessed using Microsoft Office, and in pdf format.

54 ENVIRONMENTAL SCIENCES↗

Floodplain statement of findings for corrective actions in Potrillo Canyon technical area-36, Los Alamos National Laboratory, Los Alamos, New Mexico

In 2014, baseline storm water monitoring samples for Potrillo Canyon Sample Management Area at Los Alamos National Laboratory (LANL) exceeded the National Pollutant Discharge Elimination System Individual Permit No. NM0030759 target action level (TAL) of 15 picocuries per liter (pCi/L) for gross-alpha radioactivity (393 pCi/L) and a TAL of 30 pCi/L for radium-226 and radium-228 (95.9 pCi/L). Consequently, erosion control measures within the management area are proposed to minimize sediment migration, a corrective action under the permit that is a requirement of the New Mexico Environment Department consent decree and a good management practice to limit off-site sediment migration. The area proposed for erosion controls consists of portions of Technical Area 36 that were used as firing sites primarily involving high explosives (HE) and metal (e.g., depleted uranium, lead, copper, aluminum, and steel), small-explosives experiments and burn pits (burn pits were used for burning and disposal of test debris). In addition, underground explosive tests at an approximate depth of 100 feet were also conducted. These watershed-based storm water controls will focus on addressing erosion occurring within the floodplain through mitigating and reducing both current and future channelization and head cutting.

54 ENVIRONMENTAL SCIENCES↗

Update on the aquifer/wetlands restoration project at Utica, Nebraska, with recommendations for remapping of the carbon tetrachloride contamination in groundwater.

In 1992-1993, Argonne National Laboratory investigated potential carbon tetrachloride contamination that might be linked to the former grain storage facility operated by the Commodity Credit Corporation (CCC) of the U.S. Department of Agriculture (USDA) at Utica, Nebraska. These initial studies identified carbon tetrachloride in a plume of contaminated groundwater, extending approximately 3,500 ft southeastward from the former CCC/USDA facility, within a shallow upper aquifer that had been used previously as a municipal water source by the town (Figure 1.1). A deeper aquifer used as the current municipal water source was found to be free of carbon tetrachloride contamination. Although the shallow aquifer was no longer being used as a source of drinking water at Utica, additional studies indicated that the carbon tetrachloride could pose an unacceptable health threat to potential future residents who might install private wells along the expected downgradient migration pathway of the plume. On the basis of these findings, corrective action was recommended to decrease the carbon tetrachloride concentrations in the upper aquifer to acceptable levels (Argonne 1993a,b, 1995). Initial discussions with the Utica village board indicated that any restoration strategies involving nonbeneficial discharge of treated groundwater in the immediate vicinity of Utica would be unacceptable to the town. To address this concern, the CCC/USDA and Argonne, in cooperation with multiple federal and state regulatory and environmental agencies (Table 1.1) proposed a treatment strategy for the Utica groundwater employing groundwater extraction coupled with the seasonal use of agricultural spray irrigation equipment to simultaneously (1) remove carbon tetrachloride from the groundwater (by volatilization to the atmosphere) and (2) discharge the treated groundwater to enhance the development of wetlands in the North Lake Basin Wildlife Management Area, just north of the town (Argonne 2000). To develop this treatment approach, additional groundwater sampling was conducted to update the distribution of carbon tetrachloride in groundwater identified in the preliminary studies in 1992-1993. In March 1998, detailed mapping of the carbon tetrachloride plume was performed by using the Argonne cone penetrometer (CPT) vehicle to collect groundwater samples for analyses for volatile organic compounds (VOCs) at 13 locations (PS01-PS09, PS12, PS16, PS17, PS19; Figure 1.2). The samples were collected in vertical profiles through the aquifer, at 10-ft intervals. The results of this 1998 study (Table 1.2) demonstrated that the three-dimensional distribution of carbon tetrachloride in the aquifer is complex, with multiple 'hot spots' occurring in the plume at various depths and distances along its length (Argonne 2000). In October 2002, the CCC/USDA requested that Argonne perform targeted groundwater sampling at Utica to document the migration of the carbon tetrachloride plume since the 1998 sampling event. In February 2003, vertical-profile groundwater sampling for VOCs analyses was conducted at 8 selected locations (PS01, PS04-PS07, PS12, PS19, PS20; Figure 1.2 and Table 1.3). The lateral and vertical configuration of the carbon tetrachloride plume, as identified in the 2003 study (Argonne 2003), is illustrated in Figures 1.3-1.7. On the basis of the 2003 groundwater sampling results, a remedial system employing four extraction wells (GWEX 1-GWEX 4), with groundwater treatment by spray irrigation and conventional air stripping, was implemented at Utica, with the concurrence of the CCC/USDA and the agencies identified in Table 1.1. The principal components of the Utica system (shown in Figure 1.8) are described briefly in Section 1.2. Operation of well GWEX4 and the associated air stripper began on October 29, 2004, and routine operation of wells GWEX1-GWEX3 and the spray irrigation treatment units began on November 22, 2004.

54 ENVIRONMENTAL SCIENCES↗