Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Detection And Discrimination Of Pure Gases And Binary Mixtures Using A Single Microcantilever

A new method for detecting and discriminating pure gases and binary mixtures has been investigated. This approach combines two distinct physical mechanisms within a single piezoresistive microcantilever: heat dissipation and resonant damping in the viscous regime. An experimental study of the heat dissipation mechanism indicates that the sensor response is directly correlated to the thermal conductivity of the gaseous analyte. A theoretical data set of resonant damping was generated corresponding to the gas mixtures examined in the thermal response experiments. The combination of the thermal and resonant response data yields more distinct analyte signatures that cannot otherwise be obtained from the detection modes individually.

47 OTHER INSTRUMENTATION↗

Background discrimination for neutrinoless double beta decay in liquid xenon using Cherenkov light

Neutrinoless double beta decays in liquid xenon produce a significant amount of Cherenkov light, with a photon number and angular distribution that distinguishes these events from common backgrounds. A GEANT4 simulation was used to simulate Cherenkov photon production and measurement in a liquid xenon detector and a multilayer perceptron was used to analyze the resulting distributions to classify events based on their Cherenkov photons. Our results show here that a modest improvement in the sensitivity of neutrinoless double beta decay searches is possible using this technique, but the kinematics of the neutrinoless double beta decay and electron scattering in liquid xenon substantially limit this approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Nuclear Explosion Discrimination Using a Convolutional Neural Network

Using P-wave seismograms, we trained a seismic source classifier using a Convolutional Neural Network. We trained for three classes: earthquake P-wave, underground nuclear explosion (UNE) P-wave, and noise. With the current absence of nuclear testing by countries that have signed the Comprehensive Test Ban Treaty, high quality seismic data from UNEs is limited. Even with limited training data, our model can accurately characterize most events recorded at regional and teleseismic distances, finding over 95% signals in the validation set. We applied the model on holdout datasets of the North Korean test explosions to evaluate the performance on unique region and station-source pairs, with promising results. Additionally, we tested on the Source Physics Experiment events to investigate the potential for chemical explosions to act as a surrogate for nuclear explosions. We anticipate that machine-learning models like our classifier system can have broad application for other seismic signals including volcanic and non-volcanic tremor, anomalous earthquakes, ice-quakes or landslide-quakes.

58 GEOSCIENCES↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Underwater unexploded ordnance discrimination based on intrinsic target polarizabilities – A case study

Seabed unexploded ordnance that resulted partly from the high failure rate among munitions from more than 80 years ago and from decades of military training and testing of weapons systems poses an increasing concern all around the world. Although existing magnetic systems can detect clusters of debris, they are not able to tell whether a munition is still intact requiring special removal (e.g. in situ detonation) or is harmless scrap metal. The marine environment poses unique challenges, and transferring knowledge and approaches from land to a marine environment has not been easy and straightforward. On land, the background soil conductivity is much lower than the conductivity of the unexploded ordnance and the electromagnetic response of a target is essentially the same as that in free space. For those frequencies required for target characterization in the marine environment, the seawater response must be accounted for and removed from the measurements. The system developed for this study uses fields from three orthogonal transmitters to illuminate the target and four three-component receivers to measure the signal arranged in a configuration that inherently cancels the system's response due to the enclosing seawater, the sea–bottom interface and the air–sea interface for shallow deployments. The system was tested as a cued system on land and underwater in San Francisco Bay – it was mounted on a simple platform on top of a support structure that extended 1 m below and allowed the diver to place metal objects to a specific location even in low-visibility conditions. The measurements were stable and repeatable. Furthermore, target responses estimated from marine measurements matched those from land acquisition, confirming that the seawater and air–sea interface responses were removed successfully. Thirty-six channels of normalized induction responses were used for the classification, which was done by estimating the target principal dipole polarizabilities. Our results demonstrated that the system can resolve the intrinsic polarizabilities of the target, with clear distinctions between those of symmetric intact unexploded ordnance and irregular scrap metal. The prototype system was able to classify an object based on its size, shape and metal content and correctly estimate its location and orientation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Systematic Discrimination of Advanced Hydrogen Production Technologies

The U.S. Department of Energy, in concert with industry, is developing a high-temperature gas-cooled reactor at the Idaho National Laboratory (INL) to demonstrate high temperature heat applications to produce hydrogen and electricity or to support other industrial applications. A key part of this program is the production of hydrogen from water that would significantly reduce carbon emissions compared to current production using natural gas. In 2009 the INL led the methodical evaluation of promising advanced hydrogen production technologies in order to focus future resources on the most viable processes. This paper describes how the evaluation process was systematically planned and executed. As a result, High-Temperature Steam Electrolysis was selected as the most viable near-term technology to deploy as a part of the Next Generation Nuclear Plant Project.

08 HYDROGEN↗

High-Throughput Biosensor Discriminates Between Different Algal H 2 -Photoproducing Strains

A number of species of microalgae and cyanobacteria photosynthetically produce H 2 gas by coupling water oxidation with the reduction of protons to molecular hydrogen, generating renewable energy from sunlight and water. Photosynthetic H 2 production, however, is transitory, and there is considerable interest in increasing and extending it for commercial applications. Here we report a Petri-plate version of our previous, microplate-based assay that detects photosynthetic H 2 production by algae. The assay consists of an agar overlay of H 2 -sensing Rhodobacter capsulatus bacteria carrying a green fluorescent protein that responds to H 2 produced by single algal colonies in the bottom agar layer. The assay distinguishes between algal strains that photoproduce H 2 at different levels under high light intensities, and it does so in a simple, inexpensive, and high-throughput manner. The assay will be useful for screening both natural populations and mutant libraries for strains having increased H 2 production, and useful for identifying various genetic factors that physiologically or genetically alter algal hydrogen production.

08 HYDROGEN↗

Characterization of PuO 2 With Visible and UV Raman Spectroscopy: Discrimination Between the Bulk, Surface, and an Intermediate Disordered Layer

Raman spectroscopy is an ideal tool in the characterization of materials including PuO 2 . The wavelength-dependent absorptivity of the material defines the light penetration depth and the relative Raman scattering contribution from the bulk and the surface. Here, the surface contribution to the total Raman scattering was investigated for PuO 2 calcined at various temperatures and recorded with laser wavelengths of 355, 325, and 244 nm. These experiments provided the first glimpse of the wavelength-dependent disappearance and emergence of new phonons and electronic bands from the PuO 2 surface layers. The first indication of the wavelength transition in the Raman spectra was the loss of the 2LO2 (overtone, ~1155 cm -1 ) band and the weakening intensity of the Г 1 → Γ 5 electronic band (~2135 cm -1 ) with the 355-nm excitation laser. The Γ 5 electronic band was barely visible with the 244-nm excitation. The electronic band located at ~1050 cm -1 , corresponding to the Г 1 → Γ 4 electronic transition was observed to dramatically increase in intensity while the Г 1 → Γ 3 electronic band (2640 cm -1 ) sharpened as the UV wavelength was increased in energy from the near- to deep-UV (355–325–244 nm). The FWHM of the T 2g band was found to vary with calcination temperature (450°C and 900°C) with the 325-nm laser and the 244-nm laser. The T 2g band attributes, the strong emergence of the Г 1 → Γ 4 electronic band, and the disappearance of the 2LO2 overtone acquired with the 244-nm excitation for the different calcination temperatures suggest a shallow penetration depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Topological Approach for Motion Track Discrimination

Detecting small targets at range is difficult because there is not enough spatial information present in an image sub-region containing the target to use correlation-based methods to differentiate it from dynamic confusers present in the scene. Moreover, this lack of spatial information also disqualifies the use of most state-of-the-art deep learning image-based classifiers. Here, we use characteristics of target tracks extracted from video sequences as data from which to derive distinguishing topological features that help robustly differentiate targets of interest from confusers. In particular, we calculate persistent homology from time-delayed embeddings of dynamic statistics calculated from motion tracks extracted from a wide field-of-view video stream. In short, we use topological methods to extract features related to target motion dynamics that are useful for classification and disambiguation and show that small targets can be detected at range with high probability.

Emerson, Tegan H.↗

The discriminant power of bubble wall velocities: gravitational waves and electroweak baryogenesis

A precise determination of the bubble wall velocity v$_{w}$ is crucial for making accurate predictions of the baryon asymmetry and gravitational wave (GW) signals in models of electroweak baryogenesis (EWBG). Working in the local thermal equilibrium approximation, we exploit entropy conservation to present efficient algorithms for computing v$_{w}$, significantly streamlining the calculation. We then explore the parameter dependencies of v$_{w}$, focusing on two sample models capable of enabling a strong first-order electroweak phase transition: a ℤ$_{2}$-symmetric singlet extension of the SM, and a model for baryogenesis with CP violation in the dark sector. We study correlations among v$_{w}$ and the two common measures of phase transition strength, α$_{n}$ and v$_{n}$/T$_{n}$. Interestingly, we find a relatively model-insensitive relationship between v$_{n}$/T$_{n}$ and α$_{n}$. We also observe an upper bound on α$_{n}$ for the deflagration/hybrid wall profiles naturally compatible with EWBG, the exact value for which varies between models, significantly impacting the strength of the GW signals. In summary, our work provides a framework for exploring the feasibility of EWBG models in light of future GW signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discrimination of Medicine Radix Astragali from Different Geographic Origins Using Multiple Spectroscopies Combined with Data Fusion Methods

Raman spectra and ultraviolet–visible absorption spectra of four different geographic origins of Radix Astragali were collected. These data were analyzed using kernel principal component analysis combined with sparse representation classification. The results showed that the recognition rate reached 70.44% using Raman spectra for data input and 90.34% using ultraviolet–visible absorption spectra for data input. A new fusion method based on Raman combined with ultraviolet–visible data was investigated and the recognition rate was increased to 96.43%. The experimental results suggested that the proposed data fusion method effectively improved the utilization rate of the original data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Naked-Eye Visible and Fluorescence 'Turn-On' Probe for Acetylcholinesterase Assay and the Discrimination of Biothiols

We demonstrate the utility of 4-chloro-7-nitrobenzofurazan (NBD-Cl), a simple, low-cost probe, for colorimetrically and fluorescently detecting and differentiating similar thiol species, including cysteine, homocysteine, and glutathione, as well as for assaying acetylcholinesterase (AChE) activity. This assay is a potential tool for investigating thiol functions in disease and diagnosis, and for screening AChE inhibitors. We envision that this versatile probe, which is commercially available and inexpensive, will be useful for further elucidating the roles of thiols in biology and also shows applicability for analysis of AChE inhibitors in physiological samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗