Application of a pore-scale reactive transport model to a natural analog for reaction-induced pore alterations.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.
Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.
Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning “on” and “off” of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.
Stomatal closure is a pervasive response among trees exposed to flooded soil. We tested whether this response is caused by reduced hydraulic conductance in the soil-to-leaf hydraulic continuum (k total ), and particularly by reduced root hydraulic conductance (k root ), which has been widely hypothesized. We tracked stomatal conductance at the leaf level (g s ) and canopy scale (G s ) along with physiological conditions in two temperate tree species, Magnolia grandiflora and Quercus virginiana, that were subjected to flood and control conditions in a greenhouse experiment. Flooding reduced g s , G s , k root and k total . Path analysis showed strong support for direct effects of k total on g s and for flood duration on k total , but not k root on k total . A process-based model that accounted for the k total reduction predicted the timeseries of G s in flood and control treatment trees reasonably well (predicted versus observed G s R 2 = 0.80 and 0.51 for M. grandiflora and Q. virginiana, respectively). However, accounting only for k root reduction in flooded trees was insufficient for predicting observed G s reduction. Together, these results suggest that hydraulic constraints were not limited to roots and highlight the need to account for flooding effects on k total when projecting forest ecosystem function using process-based models.
Chemical and metallurgical operations involving plutonium and other nuclear materials account for most activities performed at the LANL's Plutonium Facility (PF-4). Here, the presence of large quantities of fissile materials in numerous forms at PF-4 makes it necessary to maintain an active criticality safety program. The LANL Nuclear Criticality Safety (NCS) Program provides guidance to enable efficient operations while ensuring prevention of criticality accidents in the handling, storing, processing and transportation of fissionable material at PF-4. In order to achieve and sustain lower criticality safety control infraction (CSCI) rates, PF-4 operations are continuously improved, through the use of Lean Manufacturing and Six Sigma (LSS) business practices. Employing LSS, statistically significant variations (trends) can be identified in PF-4 CSCI reports. In this study, trends have been identified in the NCS Program using the NCS Database. An output metric has been developed that measures ADPSM Management progress toward meeting its NCS objectives and goals. Using a Pareto Chart, the primary CSCI attributes have been determined in order of those requiring the most management support. Data generated from analysis of CSCI data help identify and reduce number of corresponding attributes. In-field monitoring of CSCI's contribute to an organization's scientific and technological excellence by providing information that can be used to improve criticality safety operation safety. This increases technical knowledge and augments operational safety.
This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.
By constructing a Luenberger-type asymptotic observer, a method of finding the control function, that ensures the translation of a class of nonlinear stationary control systems of ordinary differential equations from the initial state to a given final state taking into account the actual measured values, was developed. A constructive criterion guaranteeing the existence of solution of this problem was found. An algorithm is proposed for constructing a control function that transfer wide class of nonlinear systems of ordinary differential equations from an initial state to an fixed state. The algorithm is convenient for numerical implementation. A constructive condition is obtained for which this transfer is possible.
radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.
This report from Idaho National Laboratory (INL) summarizes the key modeling and simulation activities conducted under the Department of Energy (DOE) Molten Salt Reactor (MSR) Campaign during the Fiscal Year 2023 (FY23). The focus of the work was to leverage state-of-the-art modeling capabilities from the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) codes to enable novel multiphysics and multiscale modeling and simulation of MSRs. Through collaboration with NEAMS code developers, advanced multiphysics analysis capabilities for MSR systems were demonstrated by coupling depletion, thermal-hydraulics, and thermochemistry into an innovative framework for chemical species transport in MSRs. As a result, the framework can track nuclides throughout their lifetimes in the core, from production (depletion) to advection throughout the salt volume (thermal-hydraulics) and off-gassing or precipitation outside of the salt (thermochemistry). This work supports the near-term deployment of MSRs by integrating the synergistic efforts between the DOE’s MSR Campaign and NEAMS program. The resulting framework will help better connect system design modelers with experimentalists to better understand and predict complex physical behaviors in MSRs. Researchers and MSR developers alike can now leverage these new modeling and simulation capabilities to perform novel analyses with applications including: • MSR dynamics during normal operational transients and accident scenarios • Off-gas system design and performance for fuel cycle and depletion analysis • Corrosion and active chemistry control for reactor component health and lifetime determination • Source term, decay heat and activity determination in accident scenarios • Special nuclear material accountancy and chemical forensic analysis for safeguards • Digital twin development of experiments and experimental reactor demonstrations • Measurement requirements for instrumentation and control design • Uncertainty and sensitivity analysis of missing data to inform future experimental data collection.
Energy efficiency serves as an essential part of demand-side solutions to address the challenges of energy security and carbon emission, and ensure a reliable, affordable and sustainable energy system. In this paper, a behind-the-meter transactive market is proposed for the home energy management system to achieve energy reduction by coordinating home appliances through market bidding and clearing. The proposed approach can achieve the optimal coordination by taking into account the home owner's preferences of energy reduction over different appliances. Thermostatically controlled loads (TCLs) including air conditioner and water heater are considered as the example to illustrate the controller design. The proposed controllers for TCLs can translate the trade-off between energy saving and temperature discomfort into the bidding information. The simulation results demonstrate the effectiveness of the proposed behind-the-meter transactive design for energy efficiency.
The feedback control of resistive wall modes (RWMs) in Keda Torus eXperiment (KTX) (Liu et al., Plasma Phys. Controlled Fusion 56, 094009 (2014)) is investigated by simulation. A linear model is built to describe the growth of the unstable modes in the absence of feedback and the resulting mode suppression due to feedback, given the typical reversed field pinch plasma equilibrium. The layout of KTX with two shell structures (the vacuum vessel and the stabilizing shell) is taken into account. The feedback performance is explored both in the scheme of “clean mode control” (Zanca et al., Nucl. Fusion 47, 1425 (2007)) and “raw mode control.” The discrete time control model with specific characteristic times will mimic the real feedback control action and lead to the favored control cycle. Moreover, the conceptual design of feedback control system is also presented, targeting on both RWMs and tearing modes.
The modern Mississippi River (M.R.) Delta is plumbed by the Mississippi and Atchafalaya rivers, setting water and sediment dispersal pathways for Earth’s fifth-largest river system. The Atchafalaya River’s (A.R.) partial annexation of discharge from the M.R., particularly between 1926 and 1950, prompted warnings of a rapid river avulsion and the construction of the Old River Control Structure to regulate flow. Natural and anthropogenic causes of this discharge annexation are difficult to disentangle. Here, we develop and validate a hydrodynamic model of flow partitioning through the historic channel network. We then isolate how several key changes to the system affected discharge partitioning and stage at the A.R.-M.R. diversion. Simulations show that erosion of the upper A.R. can account for 73% of the water discharge increase. Dredging in the lower A.R. between 1932 and 1950 can account for 35% of the water discharge increase, and was also an important control on shear stress distribution. The lower M.R. was slightly erosional during this period, and therefore hindered the A.R. discharge increase. Significant lacustrine delta deposition in A.R. had little effect on partitioning. These findings highlight the importance of A.R. enlargement processes on avulsion dynamics at this site. Given the essential nature of this river junction to the society, transportation, and commerce of the United States, improved attribution of discharge increases may lead to future management strategies that are broadly impactful.
One of several challenges that wave energy technologies face is their inability to generate electricity cost-competitively with other grid-scale energy generation sources. Several studies have identified two approaches to lower the levelised cost of electricity: reduce the cost over the device's lifetime or increase its overall electrical energy production. Several advanced control strategies have been developed to address the latter. However, only a few take into account the overall efficiency of the power take-off (PTO) system, and none of them solve the optimisation problem that arises at each sampling time on real-time. In this paper, a detailed Nonlinear model predictive control (NMPC) approach based on the real-time iteration (RTI) scheme is presented, and the controller performance is evaluated using a time-domain hydrodynamics model (WEC-Sim). The proposed control law incorporates the PTO system's efficiency in a control law to maximise the energy extracted. The study also revealed that RTI-NMPC clearly outperforms a simple resistive controller.
One of several challenges that wave energy technologies face is their inability to generate electricity cost-competitively with other grid-scale energy generation sources. Several studies have identified two approaches to lower the levelised cost of electricity: reduce the cost over the device's lifetime or increase its overall electrical energy production. Several advanced control strategies have been developed to address the latter. However, only a few take into account the overall efficiency of the power take-off (PTO) system, and none of them solve the optimisation problem that arises at each sampling time on real-time. In this paper, a detailed Nonlinear model predictive control (NMPC) approach based on the real-time iteration (RTI) scheme is presented, and the controller performance is evaluated using a time-domain hydrodynamics model (WEC-Sim). The proposed control law incorporates the PTO system's efficiency in a control law to maximise the energy extracted. The study also revealed that RTI-NMPC clearly outperforms a simple resistive controller.
In April 2009, President Obama revived nonproliferation and arms control efforts with a speech calling for the worldwide abolition of nuclear weapons. His speech correctly acknowledged the threat of nuclear terrorism and the vulnerabilities of the related unsecure nuclear materials. Unfortunately, the president did not mention and has not mentioned in any speech the threat posed by at-risk radiological materials. Nonproliferation efforts have a well documented history of focus on special nuclear materials (fissionable weapons usable materials or SNM), and other key materials (chemical and biological) and technologies for a Weapon of Mass Destruction (WMD). Such intense focus on WMD related materials/technologies is essential for international safety and security and merit continued attention and funding. However, the perception that radioactive sealed sources (sources) are of less concern than WMD is unfortunate. These perceptions are based solely on the potentially enormous and tragic consequences associated with their deliberate or accidental misuse and proliferation concerns. However, there is a documented history of overemphasis on the nuclear threat at the expense of ignoring the far more likely and also devastating chemical and biological threats. The radiological threat should not be minimized or excluded from policy discussions and decisions on these far ranging scopes of threat to the international community. Sources have a long history of use; and a wider distribution worldwide than fissile materials. Pair this with their broad ranges in isotopes/activities along with scant national and international attention and mechanisms for their safe and secure management and it is not difficult to envision a deadly threat. Arguments that minimize or divert attention away from sources may have the effect of distracting necessary policy attention on preventing/mitigating a radiological dispersal event. The terrorist attacks on 9/11 should be a clear reminder of the inherent danger of diminishing or dismissing lower-level threats in exchange for enhanced focus on high priority special nuclear materials with the basis for this emphasis being solely on the magnitude of the consequences of a single event. Mitigating all possible or likely terrorist attacks is impossible; however, weaponized sources, in the form of a radiological dispersal device, have been a declared target material of Al-Qaida. Eisenhower's Atoms for Peace initiative promoted the spread of the paradoxical beneficial yet destructive properties of the atom. Typically, the focus of nonproliferation efforts focuses on the fissile materials associated with Weapons of Mass Destruction, with less emphasis on radioactive materials that could be used for a Weapon of Mass Disruption. Most nonproliferation policy discussion involves securing or preventing the diversion of weapons grade fissile materials (uranium (U) with concentration of over 90% of the isotope {sup 235}U (HEU) and plutonium with more than 90% of the isotope {sup 239}Pu), with scant attention given to the threat posed by a prolific quantity of sources spread worldwide. Further acerbating the problem of inattention, it appears that the momentum of the continued evolution in the beneficial applications of sources will only increase in the near future. Several expert studies have demonstrated on the potentially devastating economic, psychological and public health impacts of terrorist use of a radiological dispersal or radiation emitting device (ROD/RED) in a metropolis. The development of such a weapon, from the acquisition of the radioactive material to the technical knowledge needed to fashion it into an ROD, is many orders of magnitude easier than diverting enough fissile material for and fabrication/acquisition of a nuclear weapon. Unlike nuclear weapons, worldwide, there are many well documented accounts of accidental and purposeful diversions of radioactive materials from regulatory control. As of the end of 2008, the International Atomic Energy Agency's (IAEA) Illicit Trafficking Database had logged 1562 incidents, of which only 18 include weapons grade nuclear materials. As much as 66% of the radioactive material involved in these incidents was not recovered. Since 2004, there has been a 75% increase in incidents of unrecoverable material, much of which is labeled dangerous with potential for deterministic health affects if misused. This makes clear that a black market of illicit trade in sources exists. The incidents reported to the IAEA's database rely only on voluntary state reporting; therefore, the number of lost or stolen sources is expected to be much higher.
Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.
With large-scale plans to integrate renewable generation driven mainly by state-level renewable portfolio requirements, more resources will be needed to compensate for the uncertainty and variability associated with intermittent generation resources. Distributed assets can be used to mitigate the concerns associated with renewable energy resources and to keep costs down. Under such conditions, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive but also technically difficult. It is therefore important to explore how a sufficient proportion of the loads could assume a routine role in primary frequency control to maintain the stability of the system at an acceptable cost. The main objective of this project is to develop a novel hierarchical distributed framework for frequency based load control. The framework involves two decision layers. The top decision layer determines the optimal gain for aggregated loads for each load bus. The gains are computed using decentralized robust control methods, and will be broadcast to the corresponding participating loads every control period. The second layer consists of a large number of heterogeneous devices, which switch probabilistically during contingencies so that aggregated power change matches the desired amount according to the most recently received gains. The simulation results show great potential to enable systematic design of demand-side primary frequency control with stability guarantees on the overall power system. The proposed design systematically accounts for the interactions between the total load response and bulk power system frequency dynamics. It also guarantees frequency stability under a wide range of time varying operating conditions. The local device-level load response rules fully respect the device constraints (such as temperature setpoint, compressor time delays of HVACs, or arrival and departure of the deferrable loads), which are crucial for implementing real load control programs. The promise of autonomous, Grid Friendly™ response by smart appliances in the form of under-frequency load shedding was demonstrated in the GridWise Olympic Peninsula Demonstration in 2006. Each controller monitored the power grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances responded reliably to each shallow under-frequency event, which was an average of one event per day and shed their loads for the durations of these events. Another objective of this project was to perform extensive simulation studies to investigate the impact of a population of Grid Friendly™ Appliances (GFAs) on the bulk power system frequency stability. The GFAs considered in this report are represented as demonstration units with water heaters individually modeled.