Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

Calaway, Michael J.↗

Modeling Contamination Migration on the Chandra X-ray Observatory II

During its first 14 years of operation, the cold (about ‐60degC) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X‐ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low‐energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition may have changed, perhaps partially related to changes in the operating temperature of the ACIS housing. This evolution of the accumulation of the molecular contamination has motivated further analysis of contamination migration on the Chandra X‐ray Observatory, particularly within and near the ACIS cavity. To this end, the current study employs a higher‐fidelity geometric model of the ACIS cavity, detailed thermal modeling based upon monitored temperature data, and an accordingly refined model of the molecular transport.

O'Dell, Stephen L.↗

Modeling Contamination Migration on the Chandra X-ray Observatory II

During its first 14 years of operation, the cold (about ‐60degC) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X‐ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low‐energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition may have changed, perhaps partially related to changes in the operating temperature of the ACIS housing. This evolution of the accumulation of the molecular contamination has motivated further analysis of contamination migration on the Chandra X‐ray Observatory, particularly within and near the ACIS cavity. To this end, the current study employs a higher‐fidelity geometric model of the ACIS cavity, detailed thermal modeling based upon monitored temperature data, and an accordingly refined model of the molecular transport.

O'Dell, Steve↗

ISS External Contamination Environment for Space Science Utilization

(1) The International Space Station is the largest and most complex on-orbit platform for space science utilization in low Earth orbit, (2) Multiple sites for external payloads, with exposure to the associated natural and induced environments, are available to support a variety of space science utilization objectives, (3) Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle, and (4)The ISS has been designed, built and integrated with strict contamination requirements to provide low levels of induced contamination on external payload assets.

Soares, Carlos↗

Development, Implementation, and Pilot Evaluation of a Model-Driven Envelope Protection System to Mitigate the Hazard of In-Flight Ice Contamination on a Twin-Engine Commuter Aircraft

Fatal loss-of-control accidents have been directly related to in-flight airframe icing. The prototype system presented in this report directly addresses the need for real-time onboard envelope protection in icing conditions. The combination of prior information and real-time aerodynamic parameter estimations are shown to provide sufficient information for determining safe limits of the flight envelope during inflight icing encounters. The Icing Contamination Envelope Protection (ICEPro) system was designed and implemented to identify degradations in airplane performance and flying qualities resulting from ice contamination and provide safe flight-envelope cues to the pilot. The utility of the ICEPro system for mitigating a potentially hazardous icing condition was evaluated by 29 pilots using the NASA Ice Contamination Effects Flight Training Device. Results showed that real time assessment cues were effective in reducing the number of potentially hazardous upset events and in lessening exposure to loss of control following an incipient upset condition. Pilot workload with the added ICEPro displays was not measurably affected, but pilot opinion surveys showed that real time cueing greatly improved their awareness of a hazardous aircraft state. The performance of ICEPro system was further evaluated by various levels of sensor noise and atmospheric turbulence.

simulation training↗

Effects of Contamination and Cleaning on Parachute Structural Textile Elements

Throughout their lifecycle, parachute textiles come into contact with various other substances. This contact may occur during manufacturing and repair, storage and transportation, packing, or actual use. While this interaction does not always result in negative repercussions, it may cause a loss in material strength. This paper examines the strength degradation due to several contaminants as well as the effects of cleaning agents on common parachute materials. Materials tested were: Kevlar cord and webbing, Nylon broadcloth and webbing, and Vectran cord; all of these constitute the major structural elements for CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module. Contaminants tested were: sewing machine oil, dried stamping ink, dirt, basting glue, Sergene, and rust. Recommendations for cleaning (or not cleaning) these materials with respect to each of the contaminants are given in this paper, as well as recommendations for future tests.

Mollmann, Catherine↗

The James Webb Space Telescope: Contamination Control and Materials

The James Webb Space Telescope (JWST), expected to launch in 2018 or early 2019, will be the premier observatory for astronomers worldwide. It is optimized for infrared wavelengths and observation from up to 1 million miles from Earth. JWST includes an Integrated Science Instrument Module (ISIM) containing the four main instruments used to observe deep space: Near-Infrared Camera (NIRCam), Near-Infrared Spectrograph (NIRSpec), Mid-Infrared Instrument (MIRI), and Fine Guidance Sensor/Near InfraRed Imager and Slitless Spectrograph (FGS/NIRISS). JWST is extremely sensitive to contamination directly resulting in degradation in performance of the telescope. Contamination control has been an essential focus of this mission since the beginning of this observatory. A particular challenge has been contamination challenges in vacuum chamber operations.

James Webb Space Telescop↗

Ammonia Stability in a Simulated Trace Contaminant Rich Cabin Environment

The off-gassing of ammonia from hardware and metabolic sources presents a unique challenge to trace contaminant control system design, driving process flowrates to meet crewed air quality requirements. Accurately simulating representative trace contaminant cabin loads during ground testing is necessary to validate component design as well as understand potential contaminant propagation across life-support system process interface boundaries. This effort is complicated by the observed temporal concentration instability of gaseous ammonia in ground test chambers. To this end, ammonia concentration decay rates were characterized under controlled environmental conditions to better understand underlying phenomena and quantify incidental mass losses. The suspected chemical interaction between ammonia and trace acetaldehyde was investigated and its effect on species quantification was examined by both gas chromatography-mass spectrometry and Fourier-transform infrared spectroscopy. Recommendations for ground test procedures were made in order to best compensate for undesirable ammonia mass losses and mitigate test artifacts.

Kayatin, Matthew J.↗

Contamination Control in Our Solar UV Sounding Rocket Projects: CLASP/CLASP2

In the CLASP / CLASP2 experiments, the contamination control was conducted mainly for the purpose of preventing molecular contamination. In particular, the organic contamination was successfully prevented. However, in the CLASP observation, the Lyα intensity decreased due to water molecules. Thus, we obtained the importance to evaluate the influence of molecules that can be easily removed and to quantitatively evaluate the vent path during the flight.

Kano, Ryouhei↗

Spacecraft Contamination Control Challenges for Space Missions with Organic Compound Detection Capabilities and for Potential Sample Return

Contamination control is critical to missions with organic compound detection capabilities, and for missions targeting acquisition of samples for potential return to Earth. Significant challenges are being addressed in the design of current flight projects and conceptual mission studies at JPL. These challenges extend to both orbiting spacecraft, as well as landed missions, for future missions to Mars and Europa, and potential missions to Titan and Enceladus. Contamination control during all phases of a mission, from preliminary design through operation, is fundamental to ensure that organic compounds of terrestrial origin are controlled to ensure successful completion of science objectives. This presentation summarizes contamination control challenges specific to landed missions (which include sample acquisition, encapsulation, caching, potential sample return, and UV instruments), and orbiting missions (modeling interactions between the spacecraft, and local exospheres and plumes).

Soares, Carlos↗

Automated Classification of Transient Contamination in Stationary Acoustic Data

An automated procedure for the classification of transient contamination of stationary acoustic data is proposed and analyzed. The procedure requires the assumption that the stationary acoustic data of interest can be modeled as a band-limited, Gaussian random process. It also requires that the transient contamination be of higher variance than the acoustic data of interest. When these assumptions are satisfied, it is a blind separation procedure, aside from the initial input specifying how to subdivide the time series of interest. No a priori threshold criterion is required. Simulation results show that for a sufficient number of blocks, the method performs well, as long as the occasional false positive or false negative is acceptable. The effectiveness of the procedure is demonstrated with an application to experimental wind tunnel acoustic test data which are contaminated by hydrodynamic gusts.

Bahr, Christopher J.↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, aLIBS system was designed and assembled at the NASA Langley Research Center (LaRC) to enable detection of ultra low concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization ofCFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity

Rodolfo I. Ledesma↗

Solar Contamination in Extreme-precision Radial-velocity Measurements: Deleterious Effects and Prospects for Mitigation

Solar contamination, due to moonlight and atmospheric scattering of sunlight, can cause systematic errors in stellar radial velocity (RV) measurements that significantly detract from the ~10 cm/s sensitivity required for the detection and characterization of terrestrial exoplanets in or near habitable zones of Sun-like stars. The addition of low-level spectral contamination at variable effective velocity offsets introduces systematic noise when measuring velocities using classical mask-based or template-based cross-correlation techniques. Here we present simulations estimating the range of RV measurement error induced by uncorrected scattered sunlight contamination. We explore potential correction techniques, using both simultaneous spectrometer sky fibers and broadband imaging via coherent fiber imaging bundles, that could reliably reduce this source of error to below the photon-noise limit of typical stellar observations. We discuss the limitations of these simulations, the underlying assumptions, and mitigation mechanisms. We also present and discuss the components designed and built into the NEID (NN-EXPLORE Exoplanet Investigations with Doppler spectroscopy) precision RV instrument for the WIYN 3.5m telescope, to serve as an ongoing resource for the community to explore and evaluate correction techniques. We emphasize that while “bright time” has been traditionally adequate for RV science, the goal of 10 cm/s precision on the most interesting exoplanetary systems may necessitate access to darker skies for these next generation instruments.

Arpita Roy↗

Removing Contamination from Genesis Sapphire Collectors by Polishing

The Genesis Solar Wind Sample Re-turn Mission used a variety of materials as solar wind (SW) collectors. “Sapphire”, which is single crystal corundum, was ~6.7% of the collector material flown. But, a much higher percentage of Genesis sapphire collectors (SAP) survived the crash of the sample-return capsule as SAP is chemically inert, physically tough, and hard (MOHS 9, by definition). In fact, 39 sapphire fragments of bulk SW collector having areas ≥60 sq mm are available in JSC’s Genesis online catalog, whereas only 1 similarly sized silicon fragment is available (accessed 1/1/2020). In spite of the ease of accessing larger fragments, sapphire has not been popular among Genesis re-searchers because it is an electrical insulator (making SIMS more difficult) and its chemical inertness, high melting point and high hardness precludes the use of many mass-spectroscopic techniques. Recently, as alternative techniques for measuring Genesis samples are developed (e.g., synchrotron TXRF, INAA, laser ablation mass spectroscopy), more researchers are choosing to analyze sapphire. Thus, a number of researchers are actively studying how to best remove contamination from the Genesis sapphire surfaces. This report extends the task in Schmeling et al. that used polishing compounds to remove contamination from Genesis sapphire and focuses on contaminants (welded silicon, aluminum) that current chemical methods find recalcitrant.

M. Schmeling↗

Forward Contamination of Ocean Worlds: A Stakeholder Conversation

A fundamental requirement for space missions designed to touch “potential habitats” is the single number 10−4, the allowable probability of a single Earth organism contaminating the potential habitat. Many aspects of a mission that affect its complexity and cost – hardware design and manufacture, assembly and test, and mission operations – are driven by this value, so it is important, on the threshold of an era of exploring ocean worlds, to have confidence in it. Yet despite its long pedigree and occasional reviews, we find that the current requirement lacks programmatically defensible justification. At issue are three weaknesses: 1) microbial biology, in particular the science of extremophiles, is a rapidly changing field; 2) forward contamination is both a scientific and an ethical issue, yet no ethics-based conversation is apparent within policy-setting circles; 3) because of these two factors, policy-setting cannot be static. We review the history of the requirement; how the evolving understanding of biology could drive it up or down; how the forward-contamination hazard relates to risk-management practice and to the ethics profession; and how a contemporary stakeholder conversation could adapt lessons already learned by other fields.

Waltemathe, Michael↗

Spacecraft Contamination Control Challenges for Space Missions with Organic Compound Detection Capabilities and for Potential Sample Return

Spacecraft contamination control is critical to space exploration missions with organic compound detection capabilities, and also for missions targeting acquisition of samples for potential return to Earth. Significant challenges are being addressed and resolved in the design of current flight projects and conceptual mission studies at JPL. These challenges extend to both orbiting spacecraft, as well as landed missions, for future missions to Mars and Europa, and potential missions to Titan and Enceladus. Contamination control during all phases of a mission, from preliminary design through operation, is fundamental to ensure that organic compounds of terrestrial origin are controlled to ensure successful completion of science objectives. This paper examines contamination control challenges specific to landed missions (which include sample acquisition, encapsulation, caching, potential sample return, and UV instruments), and orbiting missions (modeling interactions between the spacecraft and local exospheres and plumes).

Sylvia, Margarite↗

Mars 2020 sample caching system contamination: how to clean hardware and keep it clean

The Mars 2020 Rover will have the capability to collect and cache samples for potential Mars sample return. Specifically, the sample caching system (SCS) is designed for coring Mars samples and acquiring regolith samples as well as handling, sealing and caching on Mars. As the potential first Martian samples that could be returned to Earth, assuring low levels of terrestrial contamination is of the utmost concern. In developing the SCS, the project prioritizes limiting sample contamination in organic, inorganic and biological areas. The focus of this paper is on the strategies being implemented to clean the assemble the sampling hardware to meet and maintain stringent contamination requirements.

Rainen, Richard↗