Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Micro-beam bending of FCC bicrystals: A comparison between defect dynamics simulations and experiments

To understand the role of the grain boundary (GB) in plasticity at small scale, a concurrently coupled mesoscale plasticity model was developed to simulate micro-bending of bicrystalline micron-sized beams. By coupling dislocation dynamics (DD) with a finite element model (FEM), a novel defect dynamics model provides the means to investigate intricate interactions between dislocations and GBs under various loading conditions. Our simulations of micro-bending agree well with corresponding micro-bending experiments, and they show that mechanical response of bicrystals could have not only hardening but also softening depending on the characters of the GB. In addition, changing the location of the GB in the microbeams results in different mechanical responses; GBs located at the neutral plane show softening compared to single crystals, while inclined GBs located halfway along the length of the beam show little effect. In conclusion, simulation results could provide a clear picture on detailed dislocation-GB interactions, and quantitative resolved shear stress analysis supplemented by dislocation density distribution is used to analyze the mechanical response of bicrystalline samples.

36 MATERIALS SCIENCE↗

Segmentation method comparison for residual fiber length measurement across tiled microscopy images

Fiber length distribution (FLD), in part, governs mechanical properties in discontinuous fiber composites, yet manual measurement methods limit the high-throughput characterization needed for materials design optimization. This study compares deep learning segmentation approaches for automated FLD measurement in large-field microscopy, evaluating how method choice affects the microstructural descriptors used in structure-property-processing relationships. A critical challenge is that high-resolution microscopy images (10,000×10,000 pixels) must be tiled for deep learning analysis, fragmenting fibers at boundaries. We demonstrate that segmentation method proves crucial for measurement accuracy. For example, instance segmentation with Slicing Aided Hyper Inference (SAHI) preserves individual fiber integrity across tiles while semantic segmentation prioritizes speed. Comparing against manual measurement of extracted carbon fibers, YOLOv11-SAHI matched manual ground truth (238 μm weighted mean) with 40x speedup (4.5 vs 167 minutes per image). U-Net provides rapid quantification although it is at the cost of reduced accuracy due only reliably measuring stand-alone fibers. Our comparative analysis reveals that instance segmentation with SAHI better preserves length measurements while semantic segmentation prioritizes speed, providing empirical guidance for method selection. The characterization provides essential inputs for mechanical property prediction models and inverse design workflows, accelerating composite materials development cycles.

Additive manufacturing↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and biodistribution studies of 77 As-labeled trithiol RM2 bioconjugates for prostate cancer: Comparison of [ 77 As]As-trithiol-Ser-Ser-RM2 vs. [ 77 As]As-trithiol-Glu-Ser-RM2

Recent progress with the production of 72 As (2.49 Mev β + max (64%), 3.33 Mev β + max (16%), 834 keV (81%), t 1/2 : 26 h) and 77 As (0.683 Mev β- max (97%), 239 keV (1.59%), t 1/2 : 38.8 h) has facilitated their evaluation as a potential “theranostic pair” for PET imaging and radiotherapy. Our 3 rd generation trithiol chelate with two carboxylic acid groups was further developed as a bifunctional chelate for radioarsenic. The As complex with the trithiol chelate was synthesized and characterized. No carrier added (nca) [ 77 As][H 2 AsO 4 - ] was used for radiolabeling studies. Here, the trithiol chelate was conjugated to the RM2 peptide (DPhe-Gln-Trp-Ala-VaI-Gly-His-Sta-Leu-NH 2 ) via solid phase peptide synthesis with two different linkers, Ser-Ser and Glu-Ser. The trithiol chelate and its RM2 bioconjugates were radiolabeled with nca 77 As, and the RM2 bioconjugates were compared in initial biodistribution studies. The As diacid trithiol complex was characterized by 1 H NMR, 13 C NMR and HR-ESI-MS. The trithiol-RM2 precursor and As trithiol bioconjugates were characterized by HR-ESI-MS and/or LC-ESI-MS. Radiolabeling of the RM2 bioconjugates with 77 As resulted in over 85% radiochemical yield for [ 77 As]As-trithiol-Ser-Ser-RM2 ([ 77 As]8) and 90% for [ 77 As]As-trithiol-Glu-Ser-RM2 ([ 77 As]9). Both radiotracers demonstrated excellent in vitro stability (≥ 90% remaining intact through 24 h in PBS buffer) and were more hydrophilic than previous analogues based on log D 7.4 values. Biodistribution results of the two radiotracers in healthy CF-1 male mice demonstrated blockable pancreatic uptake at 1 h (82% for ([ 77 As]8 and 78% for [ 77 As]9) indicating specific gastrin-releasing peptide receptor (GRPR) uptake. The primary route of excretion was through the gastrointestinal system for both radiotracers. A new trithiol chelate with improved hydrophilicity was successfully conjugated to the RM2 peptide via two linkers, and high radiolabeling yield with nca 77 As was achieved. In vivo biodistribution studies with both radiotracers demonstrated blockable pancreatic uptake suggestive of specific receptor uptake.

07 ISOTOPE AND RADIATION SOURCES↗