Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Next-generation anion exchange membrane water electrolyzers operating for commercially relevant lifetimes

Alkaline anion exchange membrane (AEM) water electrolysis has gained increasing attention due to its potential to achieve low-cost, high performance hydrogen production. However, most existing membranes are not durable in industrial settings. In this work, we demonstrate good performance relative to industrial parameters using Sustainion® anion exchange membranes. Long-duration tests showed stable performance of 1 A/cm 2 at 1.85 V with a degradation rate of less than 1 μV/h over 10,000 h. The projected lifetime is thus over 20 years. Daily on/off cycling performance over the course of 30 years was simulated experimentally through accelerated voltage shock tests, resulting in a performance loss of only 0.15 μV/cycle over 11,000 cycles. As shown through impact and crossover testing, an improvement in performance is achieved by the addition of zirconia to the polymer matrix and mechanically reinforcing the membrane.

08 HYDROGEN↗

ECCI analysis of shear accommodations at grain boundaries in commercially pure alpha titanium

This study uses a novel approach that couples electron channeling contrast imaging (ECCI) with controlled removal of surface material to investigate the slip system/grain boundary interactions by assessing the geometry of slip planes and grain boundaries as a function of depth. The comparison of spacing, relative distributions, and correlations of slip bands across grain boundaries reveals surface biasing on the slip band behavior in the grain boundary region. Furthermore, using analysis of the compatibility factor m’, the Schmid factor of each slip system, and the angles θ between slip planes, a more comprehensive understanding of the details of the mechanisms of strain transfer and heterogeneous deformation is developed. In general, the misalignment of primary slip systems on the grain boundary planes necessitates the activation of secondary accommodating slip systems close to the grain boundary area that are better aligned (higher m’ and lower θ) with respect to the incoming slip system across the grain boundary. Such systems have the same Burgers vector as the primary slip systems within the respective grains, but are typically on low mobility slip planes.

59 BASIC BIOLOGICAL SCIENCES↗

Overcharge-to-thermal-runaway behavior and safety assessment of commercial lithium-ion cells with different cathode materials: A comparison study

In this paper, overcharge behaviors and thermal runaway (TR) features of large format lithium-ion (Li-ion) cells with different cathode materials (LiFePO 4 (LFP), Li[Ni 1/3 Co 1/3 Mn 1/3 ]O 2 (NCM111), Li[Ni 0.6 Co 0.2 Mn 0.2 ]O 2 (NCM622) and Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 (NCM811)) were investigated. The results showed that, under the same overcharge condition, the TR of LFP Li-ion cell occurred earlier compared with the NCM Li-ion cells, indicating its poor overcharge tolerance and high TR risk. However, when TR occurred, LFP Li-ion cell exhibited lower maximum temperature and mild TR response. All NCM Li-ion cells caught fire or exploded during TR, while the LFP Li-ion cell only released a large amount of smoke without fire. According to the overcharge behaviors and TR features, a safety assessment score system was proposed to evaluate the safety of the cells. In short, NCM Li-ion cells have better performance in energy density and overcharge tolerance (or low TR risk), while LFP Li-ion cell showed less severe response to overcharging (or less TR hazards). For NCM Li-ion cells, as the ratio of nickel in cathode material increases, the thermal stability of the cathode materials becomes poorer, and the TR hazards increase. Such a comparison study on large format Li-ion cells with different cathode materials can provide deeper insights into the overcharge behaviors and TR features, and provide guidance for engineers to reasonably choose battery materials in automotive applications.

25 ENERGY STORAGE↗

Identifying microstructures susceptible to pulverization in commercially irradiated high burnup UO2 under LOCA conditions

High burnup fuel fragmentation (HBFF) has been a concern in the nuclear industry for many years. When UO2 reaches and exceeds pellet average burnups around 55 GWd/tU, microstructural changes in the fuel pellet begin to occur that render the pellet susceptible to fine fragmentation under loss-of-coolant accident (LOCA) conditions. During a LOCA event, the cladding balloons and bursts, potentially releasing part of these fine fuel fragments into the reactor pressure vessel. This process is known as fuel fragmentation, relocation, and dispersal (FFRD). Presently, the US nuclear industry is developing a safety basis for FFRD with the goal of increasing burnups and pressurized water reactor cycle lengths. Increased cycle lengths would push the burnup limits of the fuel rods past the known threshold for HBFF susceptibility. In this work, the microstructural impact on HBFF was investigated by comparing the microstructures of as-irradiated rod segments to their post-LOCA tested counterparts. This investigation found that varied operational histories result in different microstructural evolutions across the pellet radius, which impacts the fragmentation behavior and radial location of the fragmentation. It is noted that regions with a high bubble density and a high density of grain boundaries fragment under LOCA-relevant conditions. In addition to the fragmentation that has been previously reported at the periphery of the fuel, fragmentation was also noted in the dark zone toward the fuel center. Analysis of the power histories of the fuel samples suggests that the dark zone forms in the central regions of the pellet between temperatures of approximately 740 and 960 °C.

McKinney, Casey [ORNL] (ORCID:0000000335383614)↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗