Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Industrial Assessment Center – integration of education and practice. Final progress report

The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturing and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years.

42 ENGINEERING↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

FutureGen: Pathway to Near-Zero Emissions and Sustainable Energy

This presentation will highlight the U.S. Department of Energy’s (DOE) FutureGen project - a $1 billion government-industry partnership to design, build, and operate a near-zero emissions coal-fueled power plant. The lead organization for the FutureGen initiative is the National Energy Technology Laboratory (NETL), a multi-purpose laboratory operated by the U.S. DOE’s Office of Fossil Energy. NETL has a mission to conduct R&D from fundamental science to technology demonstration for resolving the environmental, supply, and reliability constraints of producing and using fossil energy resources. The commercial-scale FutureGen R&D facility is a pathway toward future fossil-energy power plants that will produce hydrogen and electricity while nearly eliminating emissions, including carbon dioxide. The 275-megawatt FutureGen plant will initiate operations around 2012 and employ advanced coal gasification technology integrated with combined cycle electricity generation, hydrogen production, and carbon capture and sequestration. Low carbon emissions would be achieved by integrating CO2 capture and sequestration operations with the power plant.

01 COAL, LIGNITE, AND PEAT↗

Combining NASA Earth Observations and Commercial Smallsat Data to Inform Localized Decision Making

NASA's Earth Science Division's DEVELOP Program builds capacity in individuals and partner organizations to research the feasibility of using Earth observations for informed environmental decision making. Employing an internship-like model, DEVELOP conducts 10-week long feasibility studies that are focused on decision-making organizations' environmental concerns. These projects use the vantage point of space to address environmental issues across a broad set of themes, including agricultural monitoring, disaster risk and resilience planning, water resource and coastal management, wildfire cartography, health & air quality, and urban development. Following the establishment of NASA's Commercial Smallsat Data Acquisition (CSDA) Program, DEVELOP began adding commercial smallsat data into a subset of its feasibility projects. This presentation will highlight the program's use of CSDA data and its integration with NASA Earth observing fleet data, showcase example use cases, speak to challenges faced by the DEVELOP team in using CSDA data, and the broad array of thematic and topical applications created by DEVELOP teams.

Lisa Tanh↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Multi-Modal Wireless Sensor Platform for Smart Buildings

Buildings consume 73% of the energy produced in the United States [1, 2]. Advanced sensors, controls, and communications have the potential to reduce the energy consumption of buildings by 20–40% [3, 4]. Currently, installation and wiring costs for sensors are quite high, making it cost-prohibitive for building managers to deploy large quantities of advanced sensors [5]. Wireless sensors have recently been deployed in buildings to provide the information necessary for optimal control of heating, ventilation, and air-conditioning and lighting systems [6, 7]. Wireless sensors have the unique advantage of being suitable for easily retrofitting existing buildings at a minimal labor cost, and the flexibility to be placed at optimal, observable locations. However, current commercially available wireless sensors are still very expensive ($150–300/node). Thus, revolutionary technological improvements in wireless sensors are required to promote inherently low-cost manufacturing for building applications to successfully exploit the energy efficiency opportunities in buildings.In this report, we present the efforts carried out at Oak Ridge National Laboratory and Molex Inc. toward exploring the design, implementation, and performance evaluation of low-cost, self-powered wireless sensors—including temperature, relative humidity, occupancy, and indoor air quality sensors—to enable advanced control applications that reduce energy consumption in buildings. Our focus is to demonstrate a novel multifunctional sensor platform that will evolve with advances in materials technology, low-cost printing techniques, nano-antennas, and co-integration of monitoring, control, and communication circuitry. We also present a low-power and bandwidth-efficient wireless communication technology that can be driven by energy harvesting in self-powered wireless sensors. It is based on code-phase-shift keying (CPSK) spread-spectrum signaling that improves both transmitter range and power consumption. The objective is to minimize the number of components within the wireless transceiver and reduce power consumption to allow sensor networks powered by energy harvesting, thus eliminating the expense and effort of periodically replacing the sensor batteries. Current state-of-the-art radio technologies have demonstrated 25–30 mA current consumption for the transmitter. Our prototype demonstrations lowered the consumption to 4 mA using spread-spectrum-based CPSK so that solar cells can be used with indoor lighting to recharge a battery indefinitely. Therefore, the system can run with no attention or maintenance for the life of the components, which is expected to be 20 years. The developed technology has the potential to generate fully printable wireless sensors with costs on the order of $1–10/node.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aging of Limestones and Silane–Siloxane-Based Protective Hydrophobics: The Impact of Heating–Cooling and Freeze–Thaw Cycles

Stones are traditionally used in construction and architectural applications as building elements due to their aesthetic and technical/structural performance. Like other environmental factors (rain, humidity, moisture, salt presence, biological activity, etc.), heating–cooling and freeze–thaw cycles significantly threaten the longevity of stone materials. Hence, considering the socio-economic and cultural value of stones, preventive actions such as hydrophobic coatings are applied to prevent or mitigate damage. The scope of this study is the performance assessment of limestones with different characteristics and the efficiency of various commercial silane/siloxane-based hydrophobic coatings when exposed to thermal variation and freeze–thaw. For that purpose, the standards EN 14066:2013 (determination of resistance to aging by thermal shock) and EN 12371:2010 (determination of frost resistance) were followed. Open porosity and static contact angles were estimated to assess the stone durability and water protection capabilities of the hydrophobics. Additionally, sound speed propagation velocity, quality of building material index, elastic modulus and flexural strength were measured to evaluate the variation of mechanical properties. Static contact angle revealed that the coatings maintained an efficient level of hydrophobicity even after thermal-shock and freeze–thaw weathering tests. The study also revealed a critical interaction between freeze–thaw cycles, hydrophobic coatings and structural integrity of the stones, mostly on more porous ones. When they are subjected to harsh environmental conditions, untreated porous limestones keep structural cohesion, allowing for the natural absorption and release of water during freezing and thawing. On the contrary, when limestones are treated, the hydrophobic coatings can moderately obstruct the water release due to the partial saturation of the porous framework by the products. It also probably resulted from the different mechanical behavior between the inner matrix and layer of stone coated, resulting in a premature breakout and mechanical damage of the stone.

Lisci, Carla (ORCID:000000032179130X)↗

Mark I Silicon Carbide Integrated Circuit Test Oven Assembly and Programming Guide

This report provides a parts list, with assembly and programming instructions for building firstgeneration (Mark I) compact test ovens; this oven design is customized for prolonged functional electrical testing of prototype silicon carbide (SiC) devices at temperatures up to 500 °C (932 °F). The general approach of using multiple compact ovens to perform long-term, high-temperature electronics testing efficiently is described in a conference paper (Izadnegahdar, Alain, et al.: Alternative Setup for LongDuration Low-Duty-Cycle 600 °C Ambient Testing of SiC Integrated Circuits. International Microelectronics Assembly and Packaging Society (iMAPS) HiTECH 2021 Technology Crossover Extravaganza, 2021), available at https://ntrs.nasa.gov/citations/20210011676. The new Mark I oven design described here offers several significant improvements over the compact oven described in that paper. For example, it is constructed from commercial off-the-shelf (COTS) components and requires minimal assembly. Much of the work involves drilling holes in the two aluminum project boxes, which contain the control electronics and the oven itself. The cost of components is less than $200 (USD) per oven, which makes constructing multiple ovens affordable. In addition, the two-box design separates the high-temperature heater from the electronics, which keeps the electronics cool, prolonging the lifetime of these components.

high temperature↗

Integration of the White Sands Complex into a Wide Area Network

The NASA White Sands Complex (WSC) satellite communications facility consists of two main ground stations, an auxiliary ground station, a technical support facility, and a power plant building located on White Sands Missile Range. When constructed, terrestrial communication access to these facilities was limited to copper telephone circuits. There was no local or wide area communications network capability. This project incorporated a baseband local area network (LAN) topology at WSC and connected it to NASA's wide area network using the Program Support Communications Network-Internet (PSCN-I). A campus-style LAN is configured in conformance with the International Standards Organization (ISO) Open Systems Interconnect (ISO) model. Ethernet provides the physical and data link layers. Transmission Control Protocol and Internet Protocol (TCP/IP) are used for the network and transport layers. The session, presentation, and application layers employ commercial software packages. Copper-based Ethernet collision domains are constructed in each of the primary facilities and these are interconnected by routers over optical fiber links. The network and each of its collision domains are shown to meet IEEE technical configuration guidelines. The optical fiber links are analyzed for the optical power budget and bandwidth allocation and are found to provide sufficient margin for this application. Personal computers and work stations attached to the LAN communicate with and apply a wide variety of local and remote administrative software tools. The Internet connection provides wide area network (WAN) electronic access to other NASA centers and the world wide web (WWW). The WSC network reduces and simplifies the administrative workload while providing enhanced and advanced inter-communications capabilities among White Sands Complex departments and with other NASA centers.

Boucher, Phillip Larry↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

SU-F-T-155: Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy

Purpose: Compare proton pencil beam scanning dose measurements to GATE/GEANT4 (GMC) and RayStation™ Monte Carlo (RMC) simulations. Methods: Proton pencil beam models of the IBA gantry at the Seattle Proton Therapy Center were developed in the GMC code system and a research build of the RMC. For RMC, a preliminary beam model that does not account for upstream halo was used. Depth dose and lateral profiles are compared for the RMC, GMC and a RayStation™ pencil beam dose (RPB) model for three spread out Bragg peaks (SOBPs) in homogenous water phantom. SOBP comparisons were also made among the three models for a phantom with a (i) 2 cm bone and a (ii) 0.5 cm titanium insert. Results: Measurements and GMC estimates of R80 range agree to within 1 mm, and the mean point-to-point dose difference is within 1.2% for all integrated depth dose (IDD) profiles. The dose differences at the peak are 1 to 2%. All of the simulated spot sigmas are within 0.15 mm of the measured values. For the three SOBPs considered, the maximum R80 deviation from measurement for GMC was −0.35 mm, RMC 0.5 mm, and RPB −0.1 mm. The minimum gamma pass using the 3%/3mm criterion for all the profiles was 94%. The dose comparison for heterogeneous inserts in low dose gradient regions showed dose differences greater than 10% at the distal edge of interface between RPB and GMC. The RMC showed improvement and agreed with GMC to within 7%. Conclusion: The RPB dosimetry show clinically significant differences (> 10%) from GMC and RMC estimates. The RMC algorithm is superior to the RPB dosimetry in heterogeneous media. We suspect modelling of the beam’s halo may be responsible for a portion of the remaining discrepancy and that RayStation will reduce this discrepancy as they finalize the release. Erik Traneus is employed as a Research Scientist at RaySearch Laboratories. The research build of the RayStation TPS used in the study was made available to the SCCA free of charge. RaySearch did not provide any monetary support other than a license to use the research build of the TPS.

60 APPLIED LIFE SCIENCES↗

UNDERSTANDING FLOW OF ENERGY IN BUILDINGS USING MODAL ANALYSIS METHODOLOGY

It is widely understood that energy storage is the key to integrating variable generators into the grid. It has been proposed that the thermal mass of buildings could be used as a distributed energy storage solution and several researchers are making headway in this problem. However, the inability to easily determine the magnitude of the building’s effective thermal mass, and how the heating ventilation and air conditioning (HVAC) system exchanges thermal energy with it, is a significant challenge to designing systems which utilize this storage mechanism. In this paper we adapt modal analysis methods used in mechanical structures to identify the primary modes of energy transfer among thermal masses in a building. The paper describes the technique using data from an idealized building model. The approach is successfully applied to actual temperature data from a commercial building in downtown Boise, Idaho.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imprinted Micelle Integration into a Commercial Platform (Progress Report)

PNNL has successfully integrated a commercial aerosol detector and the imprinted micelle technology. The integrated systems have been shown to have a limit of detection between 33-47 particles with several options for data analysis presented that vary on computational requirements. It is possible to integrate these systems and receive response data on the second time scale. While more work is needed, these technologies are compatible, which opens up a large field of air sampling looking for specific contaminates.

36 MATERIALS SCIENCE↗

FY-09 Summary Report to the Office of Petroleum Reserves on the Western Energy Corridor Initiative Activities and Accomplishments

To meet its programmatic obligations under the Energy Policy Act of 2005, the Office of Naval Petroleum and Shale Oil Reserves (NPSOR) has initiated the Western Energy Corridor Initiative (WECI). The WECI will implement the Unconventional Strategic Fuels Task Force recommendations for accelerating and promoting the development of domestic unconventional fuels to help meet the nations’ energy needs. The mission of the WECI is to bolster America’s future fuel security by facilitating socially and environmentally responsible development of unconventional fuels resources in the Western Energy Corridor, using sound engineering principles and science-based methods to define and assess benefits, impacts, uncertainties, and mitigation options and to resolve impediments. The Task Force proposed a three-year program in its commercialization plan. The work described herein represents work performed by Idaho National Laboratory (INL) in support of the DOE’s WECI. This effort represents an interim phase of work, designed to initiate only select portions of the initiative, limited by available funding resources within NPOSR. Specifically, the work presented here addresses what was accomplished in FY-09 with the remaining carryover (~$420K) from NPOSR FY-08 funds. It was the intent of the NPOSR program to seek additional funding for full implementation of the full scope of work; however, the original tasks were reduced in scope, terminated, or eliminated (as noted below). An effort is ongoing to obtain funding to continue the tasks initiated under this project. This study will focus on the integrated development of multiple energy resources in a carbon-neutral and environmentally acceptable manner. Emphasis will be placed on analyses of the interrelationships of various energy-resource development plans and the infrastructure, employment, training, fiscal, and economic demands placed on the region as a result of various development scenarios. The interactions at build-out during the design, permitting, and construction of individual and multiple energy developments are not fully considered at the local, state, regional, or national levels. The net impacts to the Western Energy Corridor cannot be understood and the design optimized under the current approach. A regional development plan is needed to model cumulative impacts, determine the carrying capacity of the basin, and provide valuable technically based information to both skeptics and advocates. The INL scope of work for FY-09 involved six tasks: 1. Evaluation of the ASPEN Code as a dynamic systems model for application and use under the WECI and communications with Alberta Oil Sands Research Institutions as an “analog” resource development in the Western Energy Corridor 2. Application of the Aspen Plus computer model to several oil shale processes to consider energy balances and inputs and outputs (e.g. water consumption, CO2 production, etc.) 3. Development of a regulatory roadmap for oil shale developments 4. Defining of the physiographic extent of the natural resource reserves that comprise the Western Energy Corridor 5. A review of the Unconventional Fuels Task Force Report to Congress for ideas, concepts and recommendations that crosscutting plans 6. Program development with stakeholders, including industry, academics, state and federal agencies, and non government organizations. This task also includes project management, strategic development and reporting.

04 OIL SHALES AND TAR SANDS↗

Development, analysis, and evaluation of a commercial software framework for the study of Extremely Low Probability of Rupture (xLPR) events at nuclear power plants.

Sandia National Laboratories (SNL) participated in a Pilot Study to examine the process and requirements to create a software system to assess the extremely low probability of pipe rupture (xLPR) in nuclear power plants. This project was tasked to develop a prototype xLPR model leveraging existing fracture mechanics models and codes coupled with a commercial software framework to determine the framework, model, and architecture requirements appropriate for building a modular-based code. The xLPR pilot study was conducted to demonstrate the feasibility of the proposed developmental process and framework for a probabilistic code to address degradation mechanisms in piping system safety assessments. The pilot study includes a demonstration problem to assess the probability of rupture of DM pressurizer surge nozzle welds degraded by primary water stress-corrosion cracking (PWSCC). The pilot study was designed to define and develop the framework and model; then construct a prototype software system based on the proposed model. The second phase of the project will be a longer term program and code development effort focusing on the generic, primary piping integrity issues (xLPR code). The results and recommendations presented in this report will be used to help the U.S. Nuclear Regulatory Commission (NRC) define the requirements for the longer term program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Authentication Vulnerability Assessment of Connected Lighting Systems

Emerging connected lighting systems (CLS) that incorporate distributed intelligence, network interfaces, and sensors can become data-collection platforms that enable a wide range of valuable new capabilities as well as greater energy savings in buildings and cities. However, CLS technology is currently at an early stage of development, and its increased connectivity introduces cybersecurity risks that are new to the lighting industry and that must be addressed for successful integration with other systems. While a number of existing frameworks, guidelines, and tests for evaluating cybersecurity vulnerability may apply to CLS in whole or in part, there is currently no mandatory requirement for cybersecurity testing or certification. The lighting industry, including technology developers and specification organizations, is currently evaluating the suitability of existing frameworks and guidelines for CLS. To support these efforts, Pacific Northwest National Laboratory (PNNL) is conducting a series of studies intended to educate lighting industry stakeholders on specific cybersecurity practices and characterize their implementation in commercially available CLS with varying system architectures, network-communication technologies, and degrees of maturity. This study demonstrates that tests for authentication vulnerabilities can be developed with objective pass/fail criteria, therby facilitating comparisons between CLS. Based on the limited results of this study, it appears that the CLS that are being brought to market have varying levels of authentication vulnerability. It is hoped that these evaluations will support and perhaps accelerate industry discussions on the risks of specific security vulnerabilities, what vulnerabilities should be addressed by in-development of future lighting-specific best practices, and whether any such practices should be included in voluntary lighting standards.

42 ENGINEERING↗