Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Analysis of Wake VAS Benefits Using ACES Build 3.2.1: VAMS Type 1 Assessment

The FAA and NASA are currently engaged in a Wake Turbulence Research Program to revise wake turbulence separation standards, procedures, and criteria to increase airport capacity while maintaining or increasing safety. The research program is divided into three phases: Phase I near term procedural enhancements; Phase II wind dependent Wake Vortex Advisory System (WakeVAS) Concepts of Operations (ConOps); and Phase III farther term ConOps based on wake prediction and sensing. The Phase III Wake VAS ConOps is one element of the Virtual Airspace Modelling and Simulation (VAMS) program blended concepts for enhancing the total system wide capacity of the National Airspace System (NAS). This report contains a VAMS Program Type 1 (stand-alone) assessment of the expected capacity benefits of Wake VAS at the 35 FAA Benchmark Airports and determines the consequent reduction in delay using the Airspace Concepts Evaluation System (ACES) Build 3.2.1 simulator.

Smith, Jeremy C.↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Implementing Nationally Determined Contributions: Building Energy Policies in India’s Mitigation Strategy

The Nationally Determined Contributions (NDCs) are allowing countries to examine options for reducing emissions through a range of domestic policies. Here we use the Global Change Assessment Model to demonstrate the potential impacts of energy policies and discuss strategies to implement India’s NDC with a focus on the buildings sector. Buildings are the largest end-use sector globally, and building energy consumption is expected to increase as income grows in developing countries. We find that implementing a range of energy efficiency policies robustly can reduce total Indian building energy use by 22% and lower total Indian carbon dioxide emissions by 9% in 2050 compared to the business as usual scenario. Among various policies, energy codes for new buildings can result in the most significant savings. For all energy efficiency policies, well-coordinated, consistent implementation is critical, which requires coordination across different departments and agencies, improving capacity of stakeholders, and developing appropriate institutions to facilitate policy implementation. Renewable energy deployment can also reduce carbon emissions from buildings, and incentives in the short term are important to ensuring strong market uptake. Effective development and implementation of building energy policies could help avoid lock-in of carbon-intensive infrastructure, while improving living standards and generating health benefits.

Yu, Sha↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Polyurethanes Based on Unmodified and Refined Technical Lignins: Correlation between Molecular Structure and Material Properties

The structural complexity and robust intermolecular interactions have challenged the incorporation of technical lignin into value-added polymeric materials for decades. To study the correlation between lignin molecular structure and material properties of lignin-based polyurethanes, we applied co-solvent enhanced lignocellulosic fractionation pretreatment followed by sequential precipitation to produce three distinct lignin preparations with narrowly distributed (molecular weight dispersity <2) and comparatively low molecular weight (<1500 g/mol) from poplar biomass. Structural characterization indicated that these lignin preparations differed in average molecular chain length and stiffness as well as hydroxyl group distribution. Secondary hydroxyl group providers such as aliphatic diols and polyethers were incorporated as building blocks into the lignin-based polyurethanes to provide additional hydrogen capacity to improve the dispersion of lignin in the polyurethane network. The selected aliphatic diols and polyethers interacted with lignin molecules at different levels of strength depending on their molecular structure, and their impacts were ultimately reflected in the mechanical and thermal properties of the resulting lignin-based polyurethanes. The copolymerization of technical lignin with tailored structure and secondary hydroxyl providers could provide new strategies in formulating lignin-based/containing polyurethanes for various functional applications.

36 MATERIALS SCIENCE↗

Lone-Electron-Pair Micelles Strengthen Bond Anharmonicity in MnPb16Sb14S38 Complex Sulfosalt Leading to Ultra-Low Thermal Conductivity

Designing crystalline solids in which intrinsic extremely low lattice thermal conductivity mainly arises from its unique bonding nature rather than structure complexity and/or atomic disorder could promote thermal energy manipulation and utilization for applications ranging from thermoelectric energy conversion to thermal barrier coatings. Here, we report an extremely low lattice thermal conductivity of ~0.34 W m-1 K-1 at 300 K in the new complex sulfosalt MnPb16Sb14S38. We attribute the ultra-low lattice thermal conductivity to a synergistic combination of scattering mechanisms involving (1) strong bond anharmonicity in various structural building units, owing to the presence of stereoactive lone-electron-pair (LEP) micelles, and (2) phonon scattering at the interfaces between building units of increasing size and complexity. Remarkably, low-temperature heat capacity measurement revealed a Cp value of 0.206 J g-1 K-1 at T > 300 K, which is 22% lower than the Dulong-Petit value (0.274 J g-1 K-1). Further analysis of the Cp data and sound velocity (ν = 1834 m/s) measurement yielded Debye temperature values of 161 K and 187 K, respectively. Here, the resulting Grüneisen parameter, γ = 1.65, further supports strong bond anharmonicity as the dominant mechanism responsible for the observed extremely low lattice thermal conductivity.

36 MATERIALS SCIENCE↗

Light Water Reactor Sustainability Program: Technical and Economic Considerations for Uprate of Existing Nuclear Reactors with Cogeneration

The United States nuclear reactor fleet consists of 63 pressurized water reactors and 31 boiling water reactors and is a pivotal component in the nation's energy infrastructure, supplying approximately 97 GW e of clean power. With the country's commitment to decarbonization by 2050, these reactors are not only instrumental in decarbonizing the electricity grid but also play a critical role in decarbonizing industrial processes, producing clean fuels, and scaling up CO 2 removal. This report delves into the potential for power uprates in the existing fleet to contribute to these decarbonization efforts, focusing on the expansion of capacity for applications such as hydrogen production and carbon capture and sequestration. Building on previous research, the report explores regional market demands for hydrogen, oxygen, and carbon dioxide, financial implications of oxygen and CO 2 sales from high-temperature steam electrolysis systems, and the potential for direct air capture systems paired with uprated nuclear plants.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid Planning for Building Electrification: A Report by the Energy Systems Integration Group’s Grid Planning for Building Electrification Task Force

The increased electrification of buildings across the United States is being driven by technical advancements, cost reductions for some building technologies, consumer preferences, and policy goals for decarbonization. However, the effects of this load growth on the electric distribution system are often only a minor consideration in policymaking and long-term planning studies. The long lead time and useful life of power system equipment means that the decisions taken today are expected to support our society well into the 2060s and beyond. Distribution planning stakeholders can take steps today to establish a grid foundation that captures the new challenges presented by building electrification. This report focuses on building electrification for the residential and commercial sectors, focusing most heavily on space heating, as this end use stands to most strongly impact demand.1 Across all end uses, building electrification could require somewhere between 10% and 70% more electricity generation capacity than exists today depending on technology adoption and energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FIRST STEPS INTO AN ENERGY EFFECIENT FUTURE

Red Lake Band of Chippewa Indians proposes to develop a more sustainable, affordable and autonomous energy future for Tribal Members. The Band will develop the capacity to conduct energy audits, to implement energy efficiency measures in tribal homes, and to build more energy efficient housing. This will be done by providing direct classroom and on the job training for Tribal members to conduct the energy audits and the installation of insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strain Monitoring of Flexible Structures

One of the biggest challenges facing NASA's deep space exploration goals is structural mass. A long duration transit vehicle on a journey to Mars, for example, requires a large internal volume for cargo, supplies and crew support. As with all space structures, a large pressure vessel is not enough. The vehicle also requires thermal, micro-meteoroid, and radiation protection, a navigation and control system, a propulsion system, and a power system, etc. As vehicles get larger, their associated systems also get larger and more complex. These vehicles require larger lift capacities and force the mission to become extremely costly. In order to build large volume habitable vehicles, with only minimal increases in launch volume and mass, NASA is developing lightweight structures. Lightweight structures are made from non-metallic materials including graphite composites and high strength fabrics and could provide similar or better structural capability than metals, but with significant launch volume and mass savings. Fabric structures specifically, have been worked by NASA off and on since its inception, but most notably in the 1990's with the TransHAB program. These TransHAB developed structures use a layered material approach to form a pressure vessel with integrated thermal and micro-meteoroid and orbital debris (MMOD) protection. The flexible fabrics allow the vessel to be packed in a small volume during launch and expand into a much larger volume once in orbit. NASA and Bigelow Aerospace recently installed the first human-rated inflatable module on the International Space Station (ISS), known as the Bigelow Expandable Activity Module (BEAM) in May of 2016. The module provides a similar internal volume to that of an Orbital ATK Cygnus cargo vehicle, but with a 77% launch volume savings. As lightweight structures are developed, testing methods are vital to understanding their behavior and validating analytical models. Common techniques can be applied to fabric materials, such as tensile testing, fatigue testing, and shear testing, but common measurement techniques cannot be used on fabric. Measuring strain in a material and during a test is a critical parameter for an engineer to monitor the structure during the test and correlate to an analytical model. The ability to measure strain in fabric structures is a challenge for NASA. Foil strain gauges, for example, are commonplace on metallic structures testing, but are extremely difficult to interface with a fabric substrate. New strain measuring techniques need to be developed for use with fabric structures. This paper investigates options for measuring strain in fabric structures for both ground testing and in-space structural health monitoring. It evaluates current commercially available options and outlines development work underway to build custom measurement solutions for NASA's fabric structures.

Litteken, Douglas A.↗

Validation of Fitness for Duty Standards Using Pre- and Post-Flight Capsule Egress and Suited Functional Performance Tasks in Simulated Reduced Gravity (Pilot Egress Fitness)

As NASA prepares for exploration missions, it will be critical to understand and build upon known crew capabilities. Specifically, we need to know the functional capacities of crew at different stages of a mission and characterize these profiles so that the appropriate vehicle requirements and mission concepts of operations (ConOps) can be developed. One of the most complex phases of any missions is when there is a transition between gravity environments. For instance, both physiological adaptation to microgravity and subsequent re-entry into a gravity environment result in reduced functional capacity, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk tasks may have to be performed soon after gravity transitions: •Unassisted capsule egress task after return to Earth •Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study has been broken down into two phases. A pilot phase to assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing and the full Egress Fitness study, which will be part of the CIPHER complement. This study uses a functional task approach to characterize performance of these high-risk tasks in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and mobility to be able to complete the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth based emergency egress out of a functional capsule mockup, and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing can occur almost anytime pre-flight, but post-flight scheduling is much more critical with the capsule egress test occurring 1-4 hours after landing and the planetary EVA approximately 18-36 hours after landing. Data collected for both tasks includes task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed baseline pre-flight testing on 3 astronaut subjects. Post-flight testing of the first two subjects will be completed in November 2021 and the final subject around March 2022. Results and lessons learned from this pilot study will inform the full Egress Fitness study, which will incorporate additional pre-flight sessions, longer EVA tasks, and post-flight testing on R+1, 4, and 7 to characterize the timeframe of recovery

J R Norcross↗

Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements.

ARBI↗

Utility-Scale Solar: Empirical Trends in Project Technology, Cost, Performance, and PPA Pricing in the United States – 2018 Edition

The utility-scale solar sector has led the overall U.S. solar market in terms of installed capacity since 2012. In 2017, the utility-scale sector accounted for nearly 60% of all new solar capacity, and is expected to maintain its market-leading position for at least another six years. Two-thirds of all states, representing all regions of the country, are now home to one or more utility-scale solar projects. This report—the sixth in an ongoing annual series—provides in-depth data-driven analysis of the utility-scale solar project fleet in the United States. Drawing on empirical project-level data from a wide range of sources, this report analyzes technology trends, installed project prices, operating costs, capacity factors, power purchase agreement ("PPA") prices, the levelized cost of solar energy (LCOE), and the market value of solar. Given its current preeminence in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are also presented where appropriate. Highlights from this year's edition include: -Installation and Technology Trends: The use of solar trackers dominated 2017 installations with nearly 80% of all new capacity. In a reflection of the ongoing geographic expansion of the market beyond California and the high-insolation Southwest, the median insolation level at newly built project sites declined again in 2017. While new fixed-tilt projects are now seen predominantly in less-sunny regions, tracking projects are increasingly pushing into these same regions. The median inverter loading ratio grew to 1.32 in 2017, allowing the inverters to operate closer to full capacity for a greater percentage of the day. -Installed Prices: Median installed PV project prices have steadily fallen by two-thirds since the 2007-2009 period, to $2.0/WAC (or $1.6/WDC) for projects completed in 2017. The lowest 20th percentile of projects within our 2017 sample were priced at or below $1.8/WAC, with the lowest-priced projects around $0.9/WAC. Overall price dispersion across the entire sample has decreased steadily every year since 2013; similarly, price variation across regions decreased in 2017. -Operation and Maintenance ("O&M") Costs: PV O&M costs were in the neighborhood of $16/kWAC-year, or $8/MWh, in 2017. These numbers include only those costs incurred to directly operate and maintain the generating plant. -Capacity Factors: The cumulative net AC capacity factors of individual projects vary widely, from 14.3% to 35.2%, with a sample median of 26.3%. This project-level variation is based on a number of factors, including the strength of the solar resource at the project site, whether the array is mounted at a fixed tilt or on a tracking mechanism, the inverter loading ratio, degradation, and curtailment. Changes in at least the first three of these factors drove mean capacity factors higher from 2010-vintage to 2013-vintage projects, where they've remained fairly steady among more-recent project vintages as an ongoing increase in the prevalence of tracking has been offset by a build-out of lower resource sites. -PPA Prices and LCOE: Driven by lower installed project prices and improving capacity factors, levelized PPA prices for utility-scale PV have fallen dramatically over time, by $20-$30/MWh per year on average from 2006 through 2012, with a smaller price decline of ~$10/MWh per year evident from 2013 through 2016. Most recent PPAs in our sample—including many outside of California and the Southwest—are priced at or below $40/MWh levelized (in real 2017 dollars), with a few priced as aggressively as ~$20/MWh. The median LCOE among operational PV projects in our sample has followed PPA prices lower, suggesting a relatively competitive market for PPAs. -Solar's Wholesale Energy Market Value: Falling PPA prices have been offset to some degree by a decline in the wholesale energy market value of solar within higher-penetration markets like California, where solar earned just 79% of the average price across all hours within CAISO's real-time wholesale energy market in 2017 (down from 125% back in 2012). In other markets with less solar penetration, however, solar's hourly generation profile still earns more than the average wholesale price (e.g., 127% in ERCOT, 112% in PJM). -Solar+Storage: Adding battery storage is one way to at least partially restore the value of solar, and three recent PV+storage PPAs in Nevada (each using 4-hour batteries sized at 25% of PV nameplate capacity) suggest that the incremental PPA price adder for storage has fallen to ~$5/MWh, down from ~$15/MWh just a year ago for a similarly configured project. As PV plus battery storage becomes more cost-effective, a number of developers are regularly offering it as a viable upgrade to standalone PV. At the end of 2017, there were at least 188.5 GW of utility-scale solar power capacity within the interconnection queues across the nation. The 2017 growth within these queues is widely distributed across all regions of the country, but is most pronounced in the up-and-coming Midwest region, which accounts for 27% of the 99.2 GW of new queue capacity. The widening geographic distribution is as clear of a sign as any that the utility-scale market is maturing and expanding outside of its traditional high-insolation comfort zones.

14 SOLAR ENERGY↗

Cold Climate Heat Pumps Using Tandem Compressors

In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

Shen, Bo↗

Demonstration of Wide Area Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles - 16508

Researchers at the U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the 'Wide-Area Urban Radiological Contaminant, Mitigation, and Clean-Up Technology Demonstration' in Columbus, Ohio on June 22-25, 2015. EPA's National Homeland Security Research Center (NHSRC) demonstrated five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) on an urban building. Decontamination technologies were applied to remove the contaminants from the building's surfaces by physical, chemical, or other methods, which in practice could reduce radiation exposure level. In addition, NHSRC teamed with the Department of Homeland Security (DHS) to demonstrate several radiological contaminant mitigation technologies including building and vehicle wash technologies, as well as several approaches to contain wash water and radioactive particles. 'Radiological contaminant mitigation' technologies are measures taken to reduce adverse impacts of radiological contamination on people and the environment, and facilitate such purposes as restoration of first responder services and critical infrastructure. Radiological contaminant mitigation technologies are designed for containing and removing radiological contamination on the surface in the first hours or days following a radiological event (early phase response). Such technologies include 'radiological particle containment', which is design to prevent the spread of particles which might result from vehicle or foot traffic. Radiological particle containment technologies are applicable for early phase response to contain the radionuclides and to reduce radiation dose to responders and the public. Mitigation also includes 'gross decontamination' technologies, which perform a type of decontamination that is conducted with the goal of reducing contamination levels. This reduction may not meet final cleanup levels, but may be useful to mitigate some public hazard or contain contamination. The purpose of the demonstrations was to educate potential end-users and stakeholders of this technology about a 'Toolbox of Options' for radiological decontamination, as well as radiological contaminant mitigation. Both demonstrations were conducted using a 75-year old brick building and the surrounding area (including parking lots) in Columbus, OH. No radioactive contaminants were applied during either demonstration, as the objective was to duplicate and implement realistic operational conditions for these technologies. Surrogate contaminants such as particle tracers were used in several demonstrations. The decontamination technologies were used in a scaled-up setting with application to the building. Contaminant mitigation technologies were demonstrated on the building as well as on vehicles. Example technology application techniques/accessories included an articulating boom lift, repelling boatswain chair, stand-alone surface material structures, high-volume foam applicators, fire truck foam applicator, a vehicle wash tent for vehicles, particle tracers to simulate radiological contaminants, and high- and low-technology liquid containment approaches. Results and stakeholder observations from the demonstration are now publically in a report entitled 'Technical Report for the Demonstration of Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles' available at http://www.epa.gov/hsresearch Example information that was obtained included decontamination rate, contaminant mitigation and containment capacity, user friendliness of each technology, the required utilities (electric, water, etc.) for each technology, skill of worker required, and the cost. The condition (color, texture, integrity, etc.) of each building material present on the structure along with all structural components such as gutters, windows, doors, etc. were carefully examined and documented. All demonstrations were open to individuals, organizations, and local, state, federal, tribal, and international governments who may be involved with implementing or planning radiological incident response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

K-311-1/K-310-3 Purge Cascade Process Description, Oak Ridge Environmental Management Accelerated Cleanup Project, Oak Ridge, Tennessee

K-311-1 was constructed along with the rest of the K-25 Building in the 1943-1945 timeframe. K-311-1 was equipped with Size 3 converters and Size 38 Allis Chalmers{trademark} single-stage centrifugal compressors driven by 3600 rpm electric motors, and the unit operated as the 'bottom' unit flow-wise in K-25. The depleted flow from the bottom stage in K-311-1 passed through booster compressors and flowed to the K-601 Building where the depleted or 'tails' material was removed. In 1948, after the K-27 Building was completed, the decision was made to operate K-27 and K-25 in series rather than operate the two buildings as separate entities. To facilitate this operation, concrete bases were poured and two sets of booster compressors were installed in the extreme West end of the K-311-1 cell floor. These compressors were enclosed in heated housings and consisted of Size 38 compressors. One pair was to boost the 'B' flow between K-25 and K-27, and one pair was to boost the 'A' flow between the buildings. Each station operated with one compressor on-stream and the other in standby. (Reference 9) Each station also was equipped with a Size 2 after-cooler located in the discharge stream downstream of the junction of the onstream and standby compressors. Additional gaseous diffusion capacity was added at Oak Ridge as K-29, K-31, and K-33 were constructed and placed in service in the early 1950s. As a result of the additional process equipment added by these buildings, in-leakage of light gases to the cascade including light gases introduced into the cascade as a result of purging operations threatened to exceed the capacity of the existing K-312 Purge Cascade facilities in the K-25 Building. As a result, in 1954 K-311-1 was converted to a side purge cascade to remove light gases from the process gas stream as the stream entered K-25 from K-27. Low molecular weight gas in-leakage in K-33, K-31, K-29, and K-27 was removed by the K-311-1 Side Purge Facility and a relatively pure stream of UF6 then passed from K-311-1 into the upstream cells in K-25. In-leakage of light gases in the K-25 Building continued to be removed by the K-312 Purge Facilities. K-311-1 operated as a Side Purge Cascade from 1954 until the K-25 Building was shut down in 1964; at that time K-311-1 became the Oak Ridge Gaseous Diffusion Plant (ORGDP) Top (and only) Purge Cascade. The adjacent K-310-3 Unit was operated along with K-311-1 as the top purge cascade and K-310-2 was also operated at times to supplement cells in the K311-1/K-310-3 Purge Cascade. K-311-1 was shut down on February 14, 1977, after the newer, larger capacity K-402-9 Purge Cascade was placed in operation. K-310-3 continued to operate until the K-402-8 Coolant Removal Unit was placed in service, and K-310-3 was shut down on March 14, 1978. Since the K-311-1 and K-310-3 units continued to operate after K-25 shutdown, removal of equipment such as valves and piping for other projects did not occur in this area. As a result, these two units have not been exposed to atmospheric wet air over the years as much of the remainder of K-25 has been exposed. Any deposits or residual gases contained in K-311-1 or K-310-3 are not likely to be fully hydrolyzed.

54 ENVIRONMENTAL SCIENCES↗