Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Investigation of a Contamination Film Formed by the Electron Beam Irradiation

In the study of materials on electron probe devices in the field of action of the electron beam, a contaminating hydrocarbon film is formed, which affects the experimental results. In this paper, we have studied the influence of a contamination film on carbon-film-coated dielectrics on the intensity of cathodoluminescence and characteristic X-ray lines. The absorption coefficient of the contamination film in the visible and UV ranges has been determined. Filming mechanisms at different parameters of the electron beam have been discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Acetonitrile Contamination on Long-Term Degradation of Proton Exchange Membrane Fuel Cells

A long-term contamination (for 1000 hrs) test is conducted under constant current operation with 5 ppm acetonitrile in the air stream, and the results are compared to those for a controlled blank single-cell test. The long-term effects of the contaminant on cell performance and the structure of the membrane electrodes assembly are identified by a series of analyses, including electrochemical impedance spectroscopy, cyclic voltammetry, ion chromatography, transmission electron microscopy and scanning electron microscopy. During the long-term test, the acetonitrile significantly decreases the cell performance for a 0.1-mg Pt cm -2 catalyst coated membrane. The acetonitrile contamination accelerates catalyst particle growth; however, interestingly, it inhibited membrane degradation. This result may provide a possible approach for improving fuel cell durability.

25 ENERGY STORAGE↗

Effect of dimethyl phthalate contamination on all-silica GLAD quarter-wave plate performances

Phthalate molecular contamination, identified in the Laser Mégajoule target chamber, can severely alter porous coatings' performance, such as glancing angle deposited quarter-wave plates (QWP). QWPs could potentially be used inside this chamber to smooth the intensity of the focal spots on the target. In this study, all-silica QWP coatings were contaminated with dimethyl phthalate. Transmission was lowered due to the absorption of phthalates, and a non-uniform retardance was induced, even after a two-month storage period in air following contamination. Infrared measurements confirmed the presence of bonds associated with phthalates within the coatings due to their sorption and only partial desorption.

Contamination↗

RCT: 2.05 Contamination Control, Course #8770

This report focuses on the detection and control of radioactive contamination, which are an integral part of an aggressive ALARA program and provide an indication of the effectiveness of engineering controls and proper work practices in preventing the release of radioactive material. Radioactive contamination, if undetected or not properly controlled, can be spread and contaminate areas, equipment, personnel, and the environment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of Nanoconfinement and Elevated Temperatures on Geocolloid-Facilitated Transport of Energy-related Contaminants

The main objective of this project is to obtain a better understanding of the transport behavior and interactions of geocolloids in the presence of energy- related contaminants under bulk and nanoconfined conditions. In that, we first established solid protocols to synthesize and fabricate numerous types of geocolloids with a. various sizes ranging from 40 – 800 nm and b. different hydrophile-lipophile balance (HLB) ratios in the range of 25:75 to 75:25. Direct force measurements with geocolloids having different degrees of surface coverages (i.e. HLB to realistically mimic adsorption of energy related contaminants) were conducted using the Surface Forces Apparatus (SFA) over a distance regime starting from 8μm all the way down to molecular contact. Repulsive forces were observed on approach starting from > 3μm, followed by an exponential increase of which magnitude appears to be larger than a decay length obtained from Derjaguin–Landau–Verwey–Overbeek (DLVO) theory in pure water. When the geocolloids were confined in salted water, the magnitude of onset of repulsion was varied as a function of salinity in solution, which can significantly alter a purely repulsive screened electrostatic (coulombic) interaction arising from, among geocolloids as well as between geocolloids and geosurfaces. The viscosity and flow characteristics of geocolloidal suspensions at different degrees of confinement were also investigated where we identified highly discontinuous rheological behaviors below a critical nanoconfinement level. We anticipate that the knowledge gained through this study will enable the scientists and researchers to better assess transport and fate behaviors of geocolloidal dispersions that can carry energy-related contaminants under realistically emulated geosystem.

03 NATURAL GAS↗

Effects of Cone Penetrometer Testing on Shallow Hydrogeology at a Contaminated Site

Penetration testing is a popular and instantaneous technique for subsurface mapping, contaminant tracking, and the determination of soil characteristics. While the small footprint and reproducibility of cone penetrometer testing makes it an ideal method for in-situ subsurface investigations at contaminated sites, the effects to local shallow groundwater wells and measurable influence on monitoring networks common at contaminated sites is unknown. Physical and geochemical parameters associated with cone penetrometer testing were measured from a transect of shallow groundwater monitoring wells adjacent to penetrometer testing. For wells screened above the depth of cone refusal, the physical advancement and retraction of the cone had a significant effect ( p < 0.01) on water level for several pushes within 10 meters of a monitoring well, and a measured increase in specific conductivity. No effect on geochemistry or water level was observed in continuous monitoring data from wells screened below the depth of cone refusal, but variability in specific conductivity from these wells during penetration testing was only a fraction of the natural variation measured during precipitation events. Continuous measurements of specific conductivity and water level demonstrated that the effects of penetration testing have limited spatial and temporal distributions with a null effect post-testing.

54 ENVIRONMENTAL SCIENCES↗

Observation of Potential Contaminants in Processed Biomass Using Fourier Transform Infrared Spectroscopy

With rapidly increased interests in biomass, diverse chemical and biological processes have been applied for biomass utilization. Fourier transform infrared (FTIR) analysis has been used for characterizing different types of biomass and their products, including natural and processed biomass. During biomass treatments, some solvents and/or catalysts can be retained and contaminate biomass. In addition, contaminants can be generated by the decomposition of biomass components. Herein, we report FTIR analyses of a series of contaminants, such as various solvents, chemicals, enzymes, and possibly formed degradation by-products in the biomass conversion process along with poplar biomass. This information helps to prevent misunderstanding the FTIR analysis results of the processed biomass.

09 BIOMASS FUELS↗

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Quantifying Moss Response to Metal Contaminant Exposure Using Laser-Induced Fluorescence

Tracing sources of contamination, including potentially toxic elements (PTEs), has historically been achieved through sampling and analysis of soil or biota, which are labor-intensive, costly, and destructive methods. Thus, availability of a non-destructive in situ remote sensing method for monitoring metals deposited in biota is of great interest. Laser-induced fluorescence (LIF) is an emerging spectroscopic and imaging technique that documents changes in molecular energy level in plants as a biological response to metal contamination. For a proof-of-concept study and preliminary experiment, moss was selected for experimentation due to its long history of use in tracing atmospheric deposition of PTEs. Consecutive treatments of copper chloride (CuCl2) were administered to three moss samples, simulating wet deposition every 48 h over 10 days until reaching cumulative Cu concentrations of 2.690 to 8.075 μmol/cm2. While these Cu amounts are above environmentally relevant concentrations, they allowed the best conditions for testing and fine tuning of the imaging and data processing protocols presented in this paper. Moss fluorescence was induced using both 532 nm green and 355 nm UV lasers. A CMOS camera captured images of the LIF response, and red–green–blue (RGB) decimal code values were extracted for each pixel in the images, and pixel densities of color channels from treated and untreated moss samples were compared. Results show a shift towards lower color decimal codes corresponding to increased Cu concentration. We developed and contrasted multiple quantitative analyses of color distributions and demonstrated that LIF shows great promise for remote sensing of Cu accumulation in moss at μmol/cm2 levels. Though currently, the method would be limited to highly toxic sites, it illustrates the possibility and provides a framework for development of higher-sensitivity methods to detect nmol/cm2 that are viable for urban contamination level monitoring.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Cassini Camera Contamination Anomaly: Experiences and Lessons Learned

We discuss the contamination 'Haze' anomaly for the Cassini Narrow Angle Camera (NAC), one of two optical telescopes that comprise the Imaging Science Subsystem (ISS). Cassini is a Saturn Orbiter with a 4-year nominal mission. The incident occurred in 2001, five months after Jupiter encounter during the Cruise phase and ironically at the resumption of planned maintenance decontamination cycles. The degraded optical performance was first identified by the Instrument Operations Team with the first ISS Saturn imaging six weeks later. A distinct haze of varying size from image to image marred the images of Saturn. A photometric star calibration of the Pleiades, 4 days after the incident, showed stars with halos. Analysis showed that while the halo's intensity was only 1 - 2% of the intensity of the central peak of a star, the halo contained 30 - 70% of its integrated flux. This condition would impact science return. In a review of our experiences, we examine the contamination control plan, discuss the analysis of the limited data available and describe the one-year campaign to remove the haze from the camera. After several long conservative heating activities and interim analysis of their results, the contamination problem as measured by the camera's point spread function was essentially back to preanomaly size and at a point where there would be more risk to continue. We stress the importance of the flexibility of operations and instrument design, the need to do early infight instrument calibration and continual monitoring of instrument performance.

Cassini↗

The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

molecular contamination↗

Trace Contaminant Control During the International Space Station's On-Orbit Assembly and Outfitting

During the International Space Station’s (ISS’s) on-orbit assembly and outfitting, a series of engineering analyses was conducted to evaluate how effective the passive trace contaminant control (TCC) methods were relative to providing adequate operational margin for the active TCC equipment’s capabilities aboard the ISS. These analyses were based on habitable module and cargo vehicle offgassing test results. The offgassing test for the fully assembled module or cargo vehicle is an important preflight spacecraft evaluation method that has been used successfully during all crewed spacecraft programs to provide insight into how effectively the passive contamination control methods limit the equipment offgassing component of the overall trace contaminant generation load. The progression of TCC assessments beginning in 1998 with the ISS’s first habitable element launch and continuing through the final pressurized element’s arrival in 2010 are presented. Early cargo vehicle flight assessments between 2008 and 2011 are also presented as well as a discussion on predictive methods for assessing cargo via a purely analytical technique.

Contamination control↗

Study of Fallout Metrics for Contamination Analysis

A challenge present in assessing contamination accumulation on many missions is predicting fallout during ground processing given the multiple and various orientations possible for surfaces such as optics and instruments. The best practice assumption has been to quantify particle build up on vertical surfaces as approximately 1/10 that of horizontal surfaces. This fractional relation is important when considering contamination allocations necessary to meet cleanliness requirements since spacecraft can be in many orientations during integration and testing. There is insufficient data to provide confidence in the 1/10 approximation, yet its use can have a significant effect on mission end of life contamination level predictions, leading to expenditures of precious resources to meet mission requirements. A study was conducted to compare and analyze the fallout in horizontal and vertical orientations. Silicon wafers were deployed in four different facilities. Data sets from a long term deployment of wafers were analyzed from a cleanroom facility housing integration of the James Webb Space Telescope (JWST) as well as from a shorter term deployment of wafers in three cleanroom facilities at Goddard Space Flight Center with lower activity. There are many variables influencing the relationship between fallout on vertical and horizontal wafers, including wafer position with respect to air flow, air changes in the facility, duration of exposure, and activity workload. The goal of this continuing study is to develop a tool to inform particulate accumulation predictions for future projects.

Contamination↗

Automated Classification of Transient Contamination in Stationary Acoustic Data

An automated procedure for the classification of transient contamination of stationary acoustic data is proposed and analyzed. The procedure requires the assumption that the stationary acoustic data of interest can be modeled as a band-limited, Gaussian random process. It also requires that the transient contamination be of higher variance than the acoustic data of interest. When these assumptions are satisfied, it is a blind separation procedure, aside from the initial input specifying how to subdivide the time series of interest. No a priori threshold criterion is required. Simulation results show that for a sufficient number of blocks, the method performs well, as long as the occasional false positive or false negative is acceptable. The effectiveness of the procedure is demonstrated with an application to experimental wind tunnel acoustic test data which are contaminated by hydrodynamic gusts.

binary classification↗

Propulsive Trajectory Optimization to Minimize Surface Contamination

Descent retroburns using hydrazine thrusters will generate contaminants in their exhaust that can alter underlying samples, such as water-rich surfaces coinciding with possible life signatures or other science measurements of interest. We present an optimization technique that aims to autonomously minimize contamination during surface approach and landing for propulsive vehicles. In addition to short-range hoppers, the optimization technique is also fully applicable to traditional orbit-to-surface landers. This study addresses scenarios where surface alterations from propulsion events are counterproductive or hazardous to the mission objectives. This is of interest for landers (whether human or robotic), that may rely on pristine soils collected in the immediate vicinity of landing sites to accomplish science investigations, mining, or In Situ Resource Utilization (ISRU) surface operations. Such missions are averse to various surface-plume interactions such as thermal scoring, physical agitation, and contamination. The capability can be applied with minimal impact to the baseline concept.

Plume↗

Environmental Testing of Contamination Sensitive Instruments and Optics in Non-Cleanliness Controlled Facilities

The James Webb Space Telescope (JWST) Optical Telescope Element + Integrated Science Instrument Module (OTIS) went through environmental testing at the Goddard Space Flight Center. The vibration and acoustic tests occurred outside of cleanrooms. These areas are typically around ISO Class 8, far out of specifications for JWST. Through collaboration between the OTIS Mechanical and Contamination Engineering teams, a portable clean enclosure was designed, built, and verified to prevent contamination of the sensitive OTIS assembly. This manuscript describes the process of designing and building this enclosure, including materials selection and High Efficiency Particle Air (HEPA) filtration. This enclosure also provided environmental control with a portable air conditioning unit to control the relative humidity level enabling personnel to work within it. The manuscript emphasizes working in a systematic order to maintain cleanliness and integrity. “Clean as you go” during construction was a top priority to ensure that this critical Ground Support Equipment (GSE) was acceptable. The process of installing the walls and then sealing their internal and external surfaces with approved films was critical to maintaining OTIS integrity. This proved important because OTIS was in the enclosure for months longer than originally planned. This manuscript concludes by reviewing the process used to verify that the OTIS clean enclosure could achieve acceptable contamination level fallout accumulation for use during the vibration and acoustic testing and then verifying that the predicted performance was achieved after testing was complete.

Contamination Control, James Webb Space Telescope,↗

NASA Engineering and Safety Center Technical Bulletin No. 22-08; Contaminant Reduction in High Purity Hydrazine

Hydrazine and its derivatives are used ubiquitously in liquid propulsion systems. In smaller thruster systems, contaminant build up has historically caused flow decay and consequently performance losses. Many of these contaminants are not controlled by the current revision of MIL-PRF-26536 [1], the High Purity Hydrazine (HPH) procurement specification, yet have been observed to be present in HPH at variable concentration and, often exceed potentially problematic levels for small thrusters. This technical bulletin outlines recent work aimed at identifying appropriate separation processes to remove specific target elemental and carbonaceous contamination in HPH.

Technical Bulletin No. 22-08↗

3D Time-Lapse Geophysical Imaging Evaluation of Contaminant Migration at the Hanford BY Cribs Site

Changes in bulk electrical conductivity are governed in large part by two diagnostic parameters concerning the state of vadose zone contamination: saturation and pore fluid conductivity. As a robust, remote, non-invasive, three-dimensional, and scalable imaging tool, time-lapse electrical resistivity tomography (ERT) can provide extensive diagnostic information concerning vadose zone contaminant distribution and migration by imaging changes in bulk electrical conductivity. We demonstrate long-term surface ERT monitoring of a ~70-m-thick contaminated vadose zone to investigate whether rising groundwater nitrate levels are caused by unanticipated vadose zone flux. A three-dimensional time-lapse image spanning 10 years (2007-2017) reveals the impacts of meteoric surface infiltration events, but ultimately supports the adequacy of current conceptual understanding by indicating that rising nitrate levels are not sourced in the vadose zone.

resisitivity, geophysics, contamination, monitorin↗