Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance

PurposeTo compare technical success, clinical success, complications, radiation dose, and total room utilization time for osteoid osteoma thermal (radiofrequency or microwave) ablation using cone-beam computed tomography (CBCT) with two-axis fluoroscopic navigational overlay versus conventional computed tomography (CT) guidance.Materials and MethodsA retrospective review was performed to identify all osteoid osteoma ablations performed over a 5.5-year period at a single tertiary care pediatric hospital. Twenty-five ablations (15 radiofrequency and 10 microwave) in 23 patients undergoing fluoroscopic CBCT-guided osteoid osteoma ablation were compared to 35 ablations (35 radiofrequency) in 32 patients undergoing ablation via conventional CT guidance. Dose area product and dose length product were recorded for CBCT and conventional CT, respectively, and converted to effective doses. Technical success, clinical success (cessation of pain and medication use 1 month after ablation), complications, radiation dose, and total room utilization time were compared.ResultsAll procedures were technically successful. Twenty-two of 25 (88.0%) CBCT and 31 of 35 (88.6%) conventional CT-guided ablations achieved immediate clinical success. There were two minor complications in each group and no major complications. Mean effective radiation dose was significantly lower for CBCT compared to CT guidance (0.12 vs. 0.39 mSv, p = 0.02). Mean total room utilization time for CBCT was longer (133.5 vs. 97.5 min, p = 0.0001).ConclusionsFluoroscopic CBCT guidance for percutaneous osteoid osteoma ablation yields similar technical and clinical success, reduced radiation dose, and increased total room utilization time compared to conventional CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement

PurposeThe aim of this study was to evaluate the feasibility of cone-beam computed tomography (CBCT)-based real-time 3-D guidance of TIPSS placement and its positioning compared to standard guiding methods.Materials and MethodsIn a prospective, randomized, consecutive study design from 2015 to 2017, we included 21 patients in the CBCT guided group and 15 patients in the ultrasound (US) guided group. The prospective groups were compared in terms of success rate of intervention, portal vein puncture/procedure time, number of puncture attempts and applied dose. We furthermore retrospectively analyzed the last 23 consecutive cases with fluoroscopic guided portal vein puncture in terms of success rate, procedure time and applied dose, as it has been the standard method before US guidance.ResultsThe median number of puncture attempts (CBCT: n = 2, US: n = 4, p = 0.249) and the mean puncture time (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were not significantly different. There were furthermore no significant differences in the mean time needed for the total TIPSS procedure (CBCT: 115 ± 52 min, US: 112 ± 41 min, fluoroscopy: 110 ± 33 min, p = 0.996). The mean applied dose of the complete procedure also showed no statistically significant differences (CBCT: 563 ± 289 Gy·cm{sup 2}, US: 322 ± 186 Gy·cm{sup 2}, fluoroscopy: 469 ± 352 Gy·cm{sup 2}, p = 0.069). There were no image guidance related complications.ConclusionReal-time 3-D needle guidance based on CBCT is feasible for TIPSS placement. In terms of puncture attempts, duration and dose, CBCT guidance was not inferior to the control groups and may be a valuable support for interventionists in TIPSS procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel CT to Cone-Beam CT Registration Method Enables Immediate Real-Time Intraprocedural Three-Dimensional Assessment of Ablative Treatments of Liver Malignancies

AimTo evaluate a novel contrast-enhanced cone-beam computed tomography (CE-CBCT) registration method for accurate immediate assessment of ablation outcomes.Materials and MethodsContrast-enhanced computed tomography (CECT) was registered with CE-CBCT by applying semiautomatic landmark registration followed by automatic affine and non-rigid registration to correct for respiratory phase differences and liver deformation. This scheme was retrospectively applied to 30 patients who underwent 38 percutaneous microwave liver ablations. Three datasets were obtained for each case: (1) conventional CECT scans 24 h before ablation, (2) intraprocedural CE-CBCT scans, and (3) CECT scans 24 h post-ablation. Using a five-point scale, two experienced radiologists qualitatively assessed registration quality, equivalence of CE-CBCT assessment of ablation outcome to 24 h post-ablation CECT, and perceived increase of confidence using the fusion method to CBCT alone. Additionally, residual post-ablation tumor volumes were measured at both CE-CBCT and 24 h CECT and compared to the pre-CECT.ResultsRegistration quality was high for both radiologists (R1: 4.3 ± 0.6, R2: 4.4 ± 0.5; p = 0.87). Comparisons between the registration of pre-ablation CECT with CE-CBCT versus post-ablation CECT regarding the position of the ablated area to the treated target (R1: 4.4 ± 0.6, R2: 4.6 ± 0.4) and treatment outcome (R1: 4.5 ± 0.5, R2: 4.6 ± 0.4) were equivalent (p > 0.35). Increased confidence was noted when using fusion (R1: 4.6 ± 0.4, R2: 4.6 ± 0.4; p = 0.84). Moreover, in 6 ablations (15.8%) the intraprocedural registered CBCT showed residual tumor precisely where identified on the 24 h post-ablation CECT.ConclusionsCombined CE-CBCT holds the potential to change the current workflow of mini-invasive cancer local treatments. Given earlier visual identification of residual tumor post-ablation, this includes potentially eliminating the need for some additional treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure During Transarterial Chemoembolization: Angio-CT Versus Cone-Beam CT

Introduction: Cone-beam computed tomography (CBCT) has been developed to improve reliability of many interventional radiology (IR) procedures performed with Angio system, such as transarterial chemoembolization (TACE). Angio-CT has emerged as a new imaging technology that combines a CT scanner with an Angio system in the same IR suite. The purpose of our study was to compare Angio system with CBCT capability and Angio-CT in terms of patient radiation exposure during TACE procedures. Materials and Methods: Consecutive TACE procedures performed between January 2016 and September 2017 with the two imaging modalities (Artis Zeego defining the CBCT group and Infinix-i 4D-CT defining the Angio-CT group) were reviewed. TACE and patient’s characteristics and patient radiation exposure parameters were collected. Dose-area products (DAP) and dose-length products (DLP) were converted into effective doses (ED) using conversion factors. Accuracy of tumor targeting and response was retrospectively assessed. Results: A total of 114 TACE procedures in 96 patients were included with 57 procedures in each group. The total ED in the Angio-CT group was 2.5 times lower than that in the CBCT group (median 15.4 vs. 39.2 mSv, p < 0.001). Both 2D ED and 3D ED were lower in the Angio-CT group than in the CBCT group (5.1 vs. 20 mSv, p < 0.001, and 7.4 vs. 17.9 mSv, p < 0.001, respectively). There was no significant difference neither in terms of classes of tumor targeting (p = 0.509) nor in terms of classes of tumor response (p = 0.070) between both groups. Conclusion: Angio-CT provides significant decrease in patient effective dose during TACE procedures compared to Angio system with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The CST: Its Achievements and Its Connection to the Light Cone

since its inception in 1969, I have reviewed applications of the Covariant Spectator Theory (CST). The applications I discuss here include calculations of NN scattering, 3N bound states, electro- magnetic form factors of few-nucleon systems, and the recent successes in describing the dynamical generation of quark mass and the meson spectrum using a chirially invariant quark-antiquark interaction that includes confinement. Furthermore I will discuss the common origin of the Light Cone technique and the CST, which dates back to the 1970's.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Embedding and partial resolution of complex cones over Fano threefolds

This work deals with the study of embeddings of toric Calabi–Yau fourfolds which are complex cones over the smooth Fano threefolds. In particular, we focus on finding various embeddings of Fano threefolds inside other Fano threefolds and study the partial resolution of the latter in hope to find new toric dualities. We find many diagrams possible for many of these Fano threefolds, but unfortunately, none of them are consistent quiver theories. We also obtain a quiver Chern–Simons theory which matches a theory known to the literature, thus providing an alternate method of obtaining it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of three-dimensional retinal organoids expressing rhodopsin and S- and M-cone opsins from mouse stem cells

Highlights: • Modified SFEBq culture enabled the visualization of each photoreceptor subtype. • 9-cis retinoic acid (9cRA) promoted rod photoreceptor development in the 3D retina. • 3D retinas could be maintained for a longer period by 1% FBS supplementation. Three-dimensional retinal organoids can be differentiated from embryonic stem cells/induced pluripotent stem cells (ES/iPS cells) under defined medium conditions. We modified the serum-free floating culture of embryoid body-like aggregates with quick reaggregation (SFEBq) culture procedure to obtain retinal organoids expressing more rod photoreceptors and S- and M-cone opsins.

60 APPLIED LIFE SCIENCES↗

Measuring Interfractional and Intrafractional Motion With Cone Beam Computed Tomography and an Optical Localization System for Lower Extremity Soft Tissue Sarcoma Patients Treated With Preoperative Intensity-Modulated Radiation Therapy

Purpose: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system. Methods and Materials: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation. Results: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8{sup o} LR, 1.7{sup o} SI, and 0.7{sup o} AP and an SE SD of 1.1{sup o} LR, 1.3{sup o} SI, and 0.3{sup o} AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP. Conclusions: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assessment of Frameless Fractionated Stereotactic Radiotherapy Using Cone Beam Computed Tomography

Purpose: A quality assessment of intracranial stereotactic radiotherapy was performed using cone beam computed tomography (CBCT). Setup errors were analyzed for two groups of patients: (1) those who were positioned using a frameless SonArray (FSA) system and immobilized with a bite plate and thermoplastic (TP) mask (the bFSA group); and (2) those who were positioned by room laser and immobilized using a TP mask (the mLAS group). Methods and Materials: A quality assurance phantom was used to study the system differences between FSA and CBCT. The quality assessment was performed using an Elekta Synergy imager (XVI) (Elekta Oncology Systems, Norcross, GA) and an On-Board Imager (OBI) (Varian Medical Systems, Palo Alto, CA) for 25 patients. For the first three fractions, and weekly thereafter, the FSA system was used for patient positioning, after which CBCT was performed to obtain setup errors. Results: (1) Phantom tests: The mean differences in the isocenter displacements for the two systems was 1.2 {+-} 0.7 mm. No significant variances were seen between the XVI and OBI units (p{approx}0.208). (2)Patient tests: The mean of the displacements between FSA and CBCT were independent of the CBCT system used; mean setup errors for the bFSA group were smaller (1.2 mm) than those of the mLAS group (3.2 mm) (p < 0.005). For the mLAS patients, the 90th percentile and the maximum rotational displacements were 3{sup o} and 5{sup o}, respectively. A 4-mm drift in setup accuracy occurred over the treatment course for 1 bFSA patient. Conclusions: System differences of less than 1 mm between CBCT and FSA were seen. Error regression was observed for the bFSA patients, using CBCT (up to 4 mm) during the treatment course. For the mLAS group, daily CBCT imaging was needed to obtain acceptable setup accuracies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Online Correction via Cone-Beam CT-Based Image Guidance for Stereotactic Lung Radiotherapy

Purpose: To evaluate the dosimetric impact of online cone-beam computed tomography (CBCT) guided correction in lung stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty planning and 162 CBCT images from 20 patients undergoing lung SBRT were analyzed. The precorrection CBCT (CBCT after patient setup, no couch correction) was registered to planning CT using soft tissue; couch shift was applied, with a second CBCT for verification (postcorrection CBCT). Targets and normal structures were delineated on CBCTs: gross tumor volume (GTV), clinical target volume (CTV), cord, esophagus, lung, proximal bronchial tree, and aorta. Dose distributions on all organs manifested on each CBCT were compared with those planned on the CT. Results: Without CBCT guided target position correction, target dose reduced with respect to treatment plan. Mean and standard deviation of treatment dose discrepancy from the plan were -3.2% (4.9%), -2.1% (4.4%), -6.1% (10.7%), and -3.5% (7%) for GTV D{sub 99%}, GTV D{sub 95%}, CTV D{sub 99%}, and CTV D{sub 95%}, respectively. With CBCT correction, the results were -0.4% (2.6%), 0.1% (1.7%), -0.3% (4.2%), and 0.5% (3%). Mean and standard deviation of the difference in normal organ maximum dose were 2.2% (6.5%) before correction and 2.4% (5.9%) after correction for esophagus; 6.1% (14.1%) and 3.8% (8.1%) for cord; 3.1% (17.5%) and 6.2% (9.8%) for proximal bronchial tree; and 17.7% (19.5%) and 14.1% (17%) for aorta. Conclusion: Online CBCT guidance improves the accuracy of target dose delivery for lung SBRT. However, treatment dose to normal tissue can vary regardless of the correction. Normal tissues should be considered during target registration, according to target proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗