Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seamless Digital Environment – Plan for Data Analytics Use Case Study

The U.S Department of Energy Light Water Reactor Sustainability (LWRS) Program initiated research in to what is needed in order to provide a roadmap or model for Nuclear Power Plants to reference when building an architecture that can support the growing data supply and demand flowing through their networks. The Digital Architecture project published report Digital Architecture Planning Model (Oxstrand et. al, 2016) discusses things to consider when building an architecture to support the increasing needs and demands of data throughout the plant. Once the plant is able to support the data demands it still needs to be able to provide the data in an easy, quick and reliable method. A common method is to create a “one stop shop” application that a user can go to get all the data they need. The creation of this leads to the need of creating a Seamless Digital Environment (SDE) to integrate all the “siloed” data. An SDE is the desired perception that should be presented to users by gathering the data from any data source (e.g., legacy applications and work management systems) without effort by the user. The goal for FY16 was to complete a feasibility study for data mining and analytics for employing information from computer-based procedures enabled technologies for use in developing improved business analytics. The research team collaborated with multiple organizations to identify use cases or scenarios, which could be beneficial to investigate in a feasibility study. Many interesting potential use cases were identified throughout the FY16 activity. Unfortunately, due to factors out of the research team’s control, none of the studies were initiated this year. However, the insights gained and the relationships built with both PVNGS and NextAxiom will be valuable when moving forward with future research. During the 2016 annual Nuclear Information Technology Strategic Leadership (NITSL) group meeting it was identified would be very beneficial to the industry to support a research effort focused on data analytics. It was suggested that the effort would develop and evaluate use cases for data mining and analytics for employing information from plant sensors and database for use in developing improved business analytics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A BI-LEVEL APPROACH TO FUTURE POWER SYSTEM CO-OPTIMIZATION WITH HIGH PENETRATION OF RENEWABLE ENERGY AND RESPONSIVE DEMAND

Electricity generation accounts for nearly half of the total CO2 emissions in the United States. For this reason, the development and integration of renewable resources will play an essential role in achieving the societal objective of mitigating climate change through reduction of greenhouse gas emissions. In conjunction with the environmental benefits of renewable energy, the most common renewable sources, such as wind and solar, also increase the uncertainties surrounding generation in power systems, which adds significant challenges to the system operation and planning. The uncertainties and forecasting errors surrounding renewable generation are normally addressed through the use of reserves from traditional generators. At greater levels of renewable penetration, sufficient generator reserves may not be available or economically viable. In contrast, the promise of demand-side resources in this arena lies in the spatially widespread availability, rapid response potential, and lower cost of features that already exist in the system. However, the challenge of responsive demand arises from the need to understand, manage, and incentivize a very large number of resources to participate effectively in efficient operation of the complex power system. Since demand response comes from the distribution system, microgrids as the basic building blocks of future distribution systems will be a critical environment for the study of demand response. To support integration of microgrids with flexible loads in future power systems, the operational mode of power systems will need to evolve. Therefore, it is going to be critical to have new and efficient co-optimization methods for coordination of the various power market participants and the scheduling of resources in the power systems of the future. Motivated by the rapid increase in renewable penetration, the need for effective demand response programs, and a changing system structure, this dissertation seeks to define a new strategy that supports co-optimization of various participants in power systems with emphasis on high renewable penetration and demand response. This strategy has three components; 1) an exploration of the capabilities of different types of demand response programs in a microgrid, 2) development and implementation of a bi-level framework for co-optimization of the main grid with high renewable penetration and a microgrid with demand response capabilities, and 3) expansion of the bi-level framework from a microgrid to a general distribution system to explore the advantages of the bi-level co-optimization approach over the traditional optimization approach. Conclusions of this work illustrate that the stochastic rolling horizon approach could effectively manage the operation of a microgrid with various demand response programs. In addition, the bi-level approach is a promising co-optimization framework for the transmission and distribution levels that could increase system renewable penetration and reduce operation costs. Compared to the traditional framework, the bi-level framework yields more equitable cost sharing patterns among the market participants as well as better support for the power system evolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilization of Used Nuclear Fuel in a Potential Future US Fuel Cycle Scenario - 13499

To date, the US reactor fleet has generated approximately 68,000 MTHM of used nuclear fuel (UNF) and even with no new nuclear build in the US, this stockpile will continue to grow at approximately 2,000 MTHM per year for several more decades. In the absence of reprocessing and recycle, this UNF is a liability and needs to be dealt with accordingly. However, with the development of future fuel cycle and reactor technologies in the decades ahead, there is potential for UNF to be used effectively and efficiently within a future US nuclear reactor fleet. Based on the detailed expected operating lifetimes, the future UNF discharges from the existing reactor fleet have been calculated on a yearly basis. Assuming a given electricity demand growth in the US and a corresponding growth demand for nuclear energy via new nuclear build, the future discharges of UNF have also been calculated on a yearly basis. Using realistic assumptions about reprocessing technologies and timescales and which future fuels are likely to be reprocessed, the amount of plutonium that could be separated and stored for future reactor technologies has been determined. With fast reactors (FRs) unlikely to be commercially available until 2050, any new nuclear build prior to then is assumed to be a light water reactor (LWR). If the decision is made for the US to proceed with reprocessing by 2030, the analysis shows that the UNF from future fuels discharged from 2025 onwards from the new and existing fleet of LWRs is sufficient to fuel a realistic future demand from FRs. The UNF arising from the existing LWR fleet prior to 2025 can be disposed of directly with no adverse effect on the potential to deploy a FR fleet from 2050 onwards. Furthermore, only a proportion of the UNF is required to be reprocessed from the existing fleet after 2025. All of the analyses and conclusions are based on realistic deployment timescales for reprocessing and reactor deployment. The impact of the delay in recycling the UNF from the FRs due to time in the core, cooling time, reprocessing, and re-fabrication time is built into the analysis, along with impacts in delays and other key assumptions and sensitivities have been investigated. The results of this assessment highlight how the UNF from future reactors (LWRs and FRs) and the resulting fissile materials (U and Pu) from reprocessing can be effectively utilized, and show that the timings of future nuclear programs are key considerations (both for reactors and fuel cycle facilities). The analysis also highlights how the timings are relevant to managing the UNF and how such an analysis can therefore assist in informing the potential future R and D strategy and needs of the US fuel cycle programs and reactor technology. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The added economic and environmental value of plug-in electric vehicles connected to commercial building microgrids

Connection of electric storage technologies to smartgrids or microgrids will have substantial implications for building energy systems. In addition to potentially supplying ancillary services directly to the traditional centralized grid (or macrogrid), local storage will enable demand response. As an economically attractive option, mobile storage devices such as plug-in electric vehicles (EVs) are in direct competition with conventional stationary sources and storage at the building. In general, it is assumed that they can improve the financial as well as environmental attractiveness of renewable and fossil based on-site generation (e.g. PV, fuel cells, or microturbines operating with or without combined heat and power). Also, mobile storage can directly contribute to tariff driven demand response in commercial buildings. In order to examine the impact of mobile storage on building energy costs and carbon dioxide (CO2) emissions, a microgrid/distributed-energy-resources (DER) adoption problem is formulated as a mixed-integer linear program with minimization of annual building energy costs applying CO2 taxes/CO2 pricing schemes. The problem is solved for a representative office building in the San Francisco Bay Area in 2020. By using employees' EVs for energy management, the office building can arbitrage its costs. But since the car battery lifetime is reduced, a business model that also reimburses car owners for the degradation will be required. In general, the link between a microgrid and an electric vehicle can create a win-win situation, wherein the microgrid can reduce utility costs by load shifting while the electric vehicle owner receives revenue that partially offsets his/her expensive mobile storage investment. For the California office building with EVs connected under a business model that distributes benefits, it is found that the economic impact is very limited relative to the costs of mobile storage for the site analyzed, i.e. cost reductions from electric vehicle connections are modest. Nonetheless, this example shows that some economic benefit is created because of avoided demand charges and on-peak energy. The strategy adopted by the office building is to avoid these high on-peak costs by using energy from the mobile storage in the business hours. CO2 emission reduction strategy results indicate that EVs' contribution at the selected office building are minor.

25 ENERGY STORAGE↗

Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services

Demand response and energy storage play a profound role in the smart grid. The focus of this paper is to evaluate benefits of coordination of flexible loads and energy storage for power grid and end user services. We present a Generalized Battery Model (GBM) to describe the flexibility of building loads and energy storage. A Model Predictive Control (MPC) approach is proposed to characterize the GBM parameters (power and energy limits) for flexible building loads. Moreover, we develop optimal coordination algorithms for them to provide ancillary and end user services such as energy arbitrage, frequency regulation, spinning reserve, as well as energy and demand charge reduction. Several case studies have been performed to demonstrate the efficacy of the GBM and coordination algorithms, and evaluate the benefits of using their flexibility to provide grid and end user services. We show that optimal coordination yields significant cost saving and revenue. Moreover, the best option for grid services is to provide energy arbitrage and frequency regulation, because spinning reserve cannot compete with regulation service. Furthermore, when coordinating flexible loads with energy storage to provide end user services, it is recommended to consider both the time-of-use (TOU) price and demand charge rather than the TOU price only in order to flat the aggregate power profile.

Hao, He↗

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility system and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their collective cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and the resulting utility system impacts, are not well understood. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics (e.g., presence of controls, building type, and targeted end use) in the context of different system conditions (e.g., peak demand, load-building periods during high renewable generation output). Ultimately, the framework defines EE and DR interactions not only by the change in discretionary load (i.e., DR potential) but also by the change in likelihood of participation in EE and DR programs—as well as the change in system need for, and the overall availability of, EE and DR resources. The framework is intended to improve the integration of EE and DR in utility operational and planning activities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of long-term climate change on global building energy expenditures

This paper explores potential future implications of climate change on building energy expenditures around the globe. Increasing expenditures result from increased electricity use for cooling, and are offset to varying degrees, depending on the region, by decreased energy consumption for heating. The analysis is conducted using a model of the global buildings sector within the GCAM integrated assessment model. The integrated assessment framework is valuable because it represents socioeconomic and energy system changes that will be important for understanding building energy expenditures in the future. Results indicate that changes in net expenditures are not uniform across the globe. Net expenditures decrease in some regions, such as Canada and Russia, where heating demands currently dominate, and increase the most in areas with less demand for space heating and greater demand for space cooling. We explain these results in terms of the basic drivers that link building energy expenditures to regional climate.

Climate change impacts↗

Model-free Control of Building HVAC Systems to Accommodate Solar Photovoltaic Energy

With the increasing demand for energy in day-today life, the need for integrating renewable energy is growing. In this paper, we take a step in addressing the issue by employing solar photovoltaic (PV) energy to maintain indoor temperatures in buildings. The objective we aim to meet is to use as much of the generated PV energy as possible while maintaining the indoor comfort temperatures. We set this objective in order to reduce wastage of renewable energy and cut down the need for storage devices. We formulate a thermal model of the building HVAC system and employ the model-free control (MFC) technique to achieve the defined objective. Although recently introduced, MFC has shown promising results in various domains and it is more appealing due to its light computational complexity. Furthermore, we analyze the relationship between the generated PV energy and the total energy consumption of the buildings. The results show that the aforementioned relationship is linear in nature as the number of buildings increases.

Telsang, Bhagyashri↗

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

Intelligent Buildings of the Future: Cyberaware, Deep Learning Powered, and Human Interacting

This study discuss, intelligent buildings are quickly becoming cohesive and integral entities of cyber-physical ecosystems. Modern buildings adapt to internal and external elements and thrive on ever increasing data sources such as ubiquitous smart devices and sensors while mimicking various approaches previously known in software, hardware, and bio inspired systems. This article provides an overview of intelligent buildings of the future from a range of perspectives. First, a brief overview of prospects of U.S. and world energy consumption, concepts of smart buildings as integral entities of smart grids is presented. This is followed by a discussion of the role of connectivity and interoperability as well as current issues and solutions in the areas of security, resilience, and humans in realm of intelligent buildings. The article dives into detail about the intelligence aspect of intelligent buildings of the future. The learning and predictive Artificial Intelligence (AI) techniques behind many of the concepts of intelligent buildings are reviewed, including the latest techniques such as deep learning. As a concrete application of AI in the realm of intelligent buildings, prediction of energy consumption/load/demand, which is a much researched application of AI in the realm of intelligent buildings, is elaborated. The discussion is focused on most recent advancements of AI based demand prediction and the overview consists of existing research and a case study conducted by the authors for deep learning based demand prediction. Then, the article discusses the role of humans in intelligent buildings. Different types of human-building interactions are identified. Further, the article presents how each type of human-building interaction can benefit the overall control of intelligent buildings. The section is concluded by elaborating a case study conducted by the authors to achieve effective and efficient human-building interaction. The article is concluded with compilation of future insights based on latest technological advancements in U.S. industry and government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Personal thermal management using portable thermoelectrics for potential building energy saving

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 degrees C (70 degrees F) and 23.9 degrees C (75 degrees F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pueblo of Laguna Village Community Solar

The project was to install approximately 11.44 kilowatts (kW) rooftop solar photovoltaic (PV) system on the Mesita Village Community Center, an approximately 9.24 kW rooftop solar PV system on the Paguate Village Community Center, an approximately 21.56 kW rooftop solar PV system on the Paraje Village Community Center, and an approximately 11.00 kW rooftop solar PV system on the Seama Community Center, for a total of about 53.24 kW on four village community centers. The systems were expected to generate approximately 93,329 kWh annually. Installing solar PV systems on the four village community centers would have helped achieve the Pueblo of Laguna’s six energy objectives: community development (decreased utility bills, funds for other needs), economic development (training and participation in the renewable energy economy), energy reliability (future storage), community resilience (alternative sources), relationship to people and the natural world (reducing fossil fuel use), and energy sovereignty (Pueblo decision-making). Installing solar PV systems would have also met specific project goals to offset not less than 85% of each selected building’s annual electricity use, ranging from 87% to 103% of demand; save a minimum of 70% of the cost of utility bills per year for each building, ranging from 75% to 77% percent (including service charges); and would have had payback periods shorter than the estimated useful life of the project

14 SOLAR ENERGY↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Solar heating for a restaurant--North Little Rock, Arkansas

Hot water consumption of large building affects solar-energy system design. Continual demand for hot water at restaurant makes storage less important than at other sites. Storage capacity of system installed in December 1979 equals estimated daily hot-water requirement. Report describes equipment specifications and modifications to existing building heating and hot water systems.

Source record↗

Improving Characterization of Miscellaneous Energy Loads in Energy Demand Models

Miscellaneous energy loads (MELs) comprise a significant and growing portion of total building energy consumption. However relatively little is known about the products that make up MELs end uses, and MELs are modeled with less granularity than major end uses in energy demand models such as the U.S. Department of Energy’s Scout energy efficiency impact analysis tool or the U.S. Energy Information Administration’s National Energy Modeling System (NEMS). This paper identifies differences in the way MELs versus major building end uses are modeled, and then reviews potential sources of MELs baseline technology data that could be used to improve their characterization in energy demand models. Case studies of dry distribution transformers, hot water circulation pumps, and Japanese-style automatic bidets are presented to compare and contrast the level of baseline data available for different end uses. We show that there is potential to use data from energy conservation standards and other sources to significantly improve representation of some MELs in energy demand models, while other emerging MELs require further data collection before they can be modeled precisely.

Miscellaneous Electric Loads, MELs, Models, Nation↗