Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BNL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

(g-2){sub {mu}} and {Delta}{alpha}: recent developments and status report

We briefly review the Standard Model prediction of g-2 and confront it with the formidably accurate measurement from BNL. The focus is on recent improvements of the hadronic vacuum polarisation contributions. We also calculate the running QED coupling at the scale of the Z boson mass, {alpha}(M{sub Z}{sup 2}), an important ingredient in electroweak precision fits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

J/{psi} Production with NRQCD: HERA, Tevatron, RHIC and LHC

We report on our recent calculation of the inclusive direct photo- and hadroproduction of the J/{psi} meson at next-to-leading order within the factorization formalism of nonrelativistic QCD. We fit the color-octet (CO) long-distance matrix elements <O{sup J}/{psi}(1S{sub 0}{sup [8]})>, <O{sup J}/{psi}(3S{sub 1}{sup [8]})> and <O{sup J}/{psi}(3P{sub 0}{sup [8]})> to the transverse momentum (p{sub T}) distributions measured by CDF at Fermilab Tevatron and by H1 at DESY HERA and show that they also successfully describe the p{sub T} distributions from PHENIX at BNL RHIC and CMS at the CERN LHC as well as the photon-proton c.m. energy and (with worse agreement) the inelasticity distributions from H1. In all experiments, the CO processes are shown to be indispensable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radio-Purification of Neodymium Chloride

Organometallic liquid scintillator becomes one of the man detection mediums for neutrino experiment. Liquid-liquid extraction is the method of choice for loading metallic ions of interest into the organic solvents at BNL. High purity of all starting materials is essential for the optimization of synthesis. A newly developed 'self-scavenging' technique was applied to purify undesired radioisotopes from the starting metal compound and found to effectively remove thorium and such containments from the neodymium chloride for SNO+.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

N-{Delta} weak transition

A short review of the Rein-Sehgal and isobar models is presented. The attention is focused on the nucleon-{Delta}(1232) weak transition form-factors. The results of the recent re-analyses of the ANL and BNL bubble chamber neutrino-deuteron scattering data are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical study of self modulation instability of 1 nC electron bunch at ATF

The development of self-modulation instability (SMI) is investigated numerically for the 1 nC electron bunch available at Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL). Possible experiment based on the simulation results is proposed. All the simulations are performed with the 2D-cylindrically symmetric particle-in-cell code.

43 PARTICLE ACCELERATORS↗

Numerical simulation of ion charge breeding in electron beam ion source

The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results of radial profiles and velocity space distributions of the trapped ions are presented.

43 PARTICLE ACCELERATORS↗

Recent progress and tests of radiation resistant impregnation materials for Nb{sub 3}Sn coils

Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb{sub 3}Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of “ten stacks” of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy.

43 PARTICLE ACCELERATORS↗

Characterizations of MCP performance in the hard x-ray range (6–25 keV)

MCP detector performance at hard x-ray energies from 6 to 25 keV was recently investigated using NSLS beamline X15A at BNL. Measurements were made with an NSTec Gen-II (H-CA-65) framing camera, based on a Photonis MCP with ∼10 μm in diameter pores, ∼12 μm center-center spacing, an L/D ratio of 46, and a bias angle of 8°. The MCP characterizations were focused on (1) energy and angle dependent sensitivity, (2) energy and angle dependent spatial resolution, (3) energy dependent gain performance, and (4) energy dependent dynamic range. These measurement corroborated simulation results using a Monte Carlo model that included hard x-ray interactions and the subsequent electron cascade in the MCP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High performance charge breeder for HIE-ISOLDE and TSR@ISOLDE applications

We report on the development of the HEC{sup 2} (High Energy Compression and Current) charge breeder, a possible high performance successor to REXEBIS at ISOLDE. The new breeder would match the performance of the HIE-ISOLDE linac upgrade and make full use of the possible installation of a storage ring at ISOLDE (the TSR@ISOLDE initiative [1]). Dictated by ion beam acceptance and capacity requirements, the breeder features a 2–3.5 A electron beam. In many cases very high charge states, including bare ions up to Z=70 and Li/Na-like up to Z=92 could be requested for experiments in the storage ring, therefore, electron beam energies up to 150 keV are required. The electron-beam current density needed for producing ions with such high charge states at an injection rate into TSR of 0.5–1 Hz is between 10 and 20 kA/cm{sup 2}, which agrees with the current density needed to produce A/q<4.5 ions for the HIE-ISOLDE linac with a maximum repetition rate of 100 Hz. The first operation of a prototype electron gun with a pulsed electron beam of 1.5 A and 30 keV was demonstrated in a joint experiment with BNL [2]. In addition, we report on further development aiming to achieve CW operation of an electron beam having a geometrical transverse ion-acceptance matching the injection of 1{sup +} ions (11.5 μm), and an emittance/energy spread of the extracted ion beam matching the downstream mass separator and RFQ (0.08 μm normalized / ± 1%)

43 PARTICLE ACCELERATORS↗

Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

43 PARTICLE ACCELERATORS↗

Plasma sputtering robotic device for in-situ thick coatings of long, small diameter vacuum tubes

A novel robotic plasma magnetron mole with a 50 cm long cathode was designed, fabricated, and operated. The reason for this endeavor is to alleviate the problems of unacceptable resistive heating of stainless steel vacuum tubes in the BNL Relativistic Heavy Ion Collider (RHIC). The magnetron mole was successfully operated to copper coat an assembly containing a full-size, stainless steel, cold bore, RHIC magnet tubing connected to two types of RHIC bellows, to which two additional pipes made of RHIC tubing were connected. To increase the cathode lifetime, a movable magnet package was developed, and the thickest possible cathode was made, with a rather challenging target to substrate (de facto anode) distance of less than 1.5 cm. Achieving reliable steady state magnetron discharges at such a short cathode to anode gap was rather challenging, when compared to commercial coating equipment, where the target to substrate distance is 10's cm; 6.3 cm is the lowest experimental target to substrate distance found in the literature. Additionally, the magnetron developed during this project provides unique omni-directional uniform coating. The magnetron is mounted on a carriage with spring loaded wheels that successfully crossed bellows and adjusted for variations in vacuum tube diameter, while keeping the magnetron centered. Electrical power and cooling water were fed through a cable bundle. The umbilical cabling system is driven by a motorized spool. Excellent coating adhesion was achieved. Measurements indicated that well-scrubbed copper coating reduced secondary electron yield to 1, i.e., the problem of electron clouds can be eliminated. Room temperature RF resistivity measurement indicated that a 10 μm copper coated stainless steel RHIC tube has a conductivity close to that of pure copper tubing. Excellent coating adhesion was achieved. The device details and experimental results are described.

36 MATERIALS SCIENCE↗

Consistent analysis of neutral- and charged-current (anti)neutrino scattering off carbon

Good understanding of the cross sections for (anti)neutrino scattering off nuclear targets in the few-GeV energy region is a prerequisite for the correct interpretation of results of ongoing and planned oscillation experiments. To clarify a possible source of disagreement between recent measurements of the cross sections on carbon, we analyze the available data within an approach based on the realistic spectral function of carbon, treating neutral-current elastic (NCE) and charged-current quasielastic (CCQE) processes on equal footing. We show that the axial mass from the shape analysis of the MiniBooNE data is in good agreement with the results reported by the BNL E734 and NOMAD Collaborations. However, the combined analysis of the NCE and CCQE data does not seem to support the contribution of multinucleon final states being large enough to explain the normalization of the MiniBooNE-reported cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calcium and lithium ion production for laser ion source

Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest experiences and future plans on NSLS-II insertion devices

National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

43 PARTICLE ACCELERATORS↗

Gold Nanoparticles Enhance the Radiation Therapy of a Murine Squamous Cell Carcinoma

The purpose of this study is to test the hypothesis that gold nanoparticle (AuNP, nanogold)-enhanced radiation therapy (nanogold radiation therapy, NRT) is efficacious when treating the radiation resistant and highly aggressive mouse head and neck squamous cell carcinoma model, SCCVII, and to identify parameters influencing the efficacy of NRT. Subcutaneous (sc) SCCVII leg tumors in mice were irradiated with x-rays at the Brookhaven National Laboratory (BNL) National Synchrotron Light Source (NSLS) with and without prior intravenous (iv) administration of AuNPs. Variables studied included radiation dose, beam energy, temporal fractionation and hyperthermia. AuNP-mediated NRT was shown to be effective for the sc SCCVII model. AuNPs were more effective at 42 Gy than at 30 Gy (both at 68 keV median beam energy) compared to controls without gold. Similarly, at 157 keV median beam energy, 50.6 Gy NRT was more effective than 44 Gy NRT. At the same radiation dose (42 Gy), 68 keV was more effective than 157 keV. Hyperthermia and radiation therapy (RT) were synergistic and AuNPs enhanced this synergy, thereby further reducing TCD50 s (tumor control dose 50%) and increasing long-term survivals. It is concluded that gold nanoparticles enhance the radiation therapy of a radioresistant mouse squamous cell carcinoma. The data show that radiation dose, energy and hyperthermia influence efficacy and better define the potential utility of gold nanoparticles for cancer x-ray therapy.

43 PARTICLE ACCELERATORS↗

Exploring the initial state in relativistic heavy ion collisions

While the most spectacular effects seen in relativistic heavy ion collisions are attributed to the formation of a strongly interacting, hot and dense medium (final state), there is a rapidly growing consensus that the initial state of the incoming relativistic nuclei is in part responsible for the observed phenomena. The initial state is best studied in d+Au collisions where only cold nuclear matter is present and probed by a single proton or neutron. Based on the latest results from the PHENIX experiment at RHIC (BNL) from the high statistics d+Au data at {radical}s{sub NN} = 200 GeV (2008) we will review the nuclear modification factors at forward rapidities as well as the status of central-forward and forward-forward correlations which provide an important test of gluon saturation in the Au nucleus at low momentum fraction x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal observables for the chiral magnetic effect from machine learning

The detection of the chiral magnetic effect (CME) in relativistic heavy-ion collisions remains challenging due to substantial background contributions that obscure the expected signal. In this Letter, we present a novel machine learning approach for constructing optimized observables that significantly enhance CME detection capabilities. By parametrizing generic observables constructed from flow harmonics and optimizing them to maximize the signal-to-background ratio, we systematically develop CME-sensitive measures that outperform conventional methods. Using simulated data from the anomalous viscous fluid dynamics framework, our machine learning observables demonstrate up to 90% higher sensitivity to CME signals compared to traditional 𝛾 and 𝛿 correlators, while maintaining minimal background contamination. The constructed observables provide physical insight into optimal CME detection strategies and offer a promising path forward for experimental searches of the CME at the BNL Relativistic Heavy Ion Collider and the CERN Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗