Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX

We describe the upgrade of the neutron resonance spin-echo setup at the cold neutron triple-axis spectrometer FLEXX at the BER II neutron source at the Helmholtz-Zentrum Berlin. The parameters of redesigned key components are discussed, including the radio frequency (RF) spin-flip coils, the magnetic shield, and the zero field coupling coils. The RF-flippers with larger beam windows allow for an improved neutron flux transfer from the source to the sample and further to the analyzer. The larger beam cross sections permit higher coil inclination angles and enable measurements on dispersive excitations with a larger slope of the dispersion. Due to the compact design of the spin-echo units in combination with the increased coil tilt angles, the accessible momentum-range in the Larmor diffraction mode is substantially enlarged. In combination with the redesigned components of the FLEXX spectrometer, including the guide, the S-bender polarizer, the double focusing monochromator, and a Heusler crystal analyzer, the count rate increased by a factor of 15.5, and the neutron beam polarization is enhanced. The improved performance extends the range of feasible experiments, both for inelastic scattering on excitation lifetimes in single crystals, and for high-resolution Larmor diffraction. The experimental characterization of the instrument components demonstrates the reliable performance of the new neutron resonance spin-echo option, now available for the scientific community at FLEXX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of laser entrance hole foil thickness on MagLIF-relevant laser preheat

The magnetized liner inertial fusion (MagLIF) scheme relies on coupling laser energy into an underdense fuel raising the fuel adiabat at the start of the implosion. To deposit energy into the fuel, the laser must first penetrate a laser entrance hole (LEH) foil which can be a significant energy sink and introduce mix. In this paper, we report on experiments investigating laser energy coupling into MagLIF-relevant gas cell targets with LEH foil thicknesses varying from 0.5 μm to 3 μm. Two-dimensional (2D) axisymmetric simulations match the experimental results well for 0.5 μm and 1 μm thick LEH foils but exhibit whole-beam self-focusing and excessive penetration of the laser into the gas for 2 μm and 3 μm thick LEH foils. Additionally, better agreement for the 2 μm-thick foil is found when using a different thermal conductivity model in 2D simulations, while only 3D Cartesian simulations come close to matching the 3 μm-thick foil experiments. The study suggests that simulations may over-predict the tendency for the laser to self-focus during MagLIF preheat when thicker LEH foils are used. This effect is pronounced with 2D simulations where the azimuthally symmetric density channel effectively self-focuses the rays that are forced to traverse the center of the plasma. The extra degree of freedom in 3D simulations significantly reduces this effect. The experiments and simulations also suggest that, in this study, the amount of energy coupled into the gas is highly correlated with the laser propagation length regardless of the LEH foil thickness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the Jefferson Lab 12 GeV Experimental Program in Halls A,B, and C

The 11 GeV beam energy available in experimental Halls A, B, and C as part of the Jefferson Lab 12 GeV Upgrade, combined with the new equipment in those halls will provide a rich and diverse physics program. This program includes inclusive measurements used to constrain polarized and unpolarized quark distributions in nucleons, exclusive reactions to access nucleon and meson form factors and GPDs, semi-inclusive measurements aimed at constraining TMDs, as well as measurements from nuclei to provide further insight into the origins of Short Range Correlations and the EMC Effect. The experimental equipment was designed with the above program in mind and the three halls provide complementary capabilities. Magnetic focusing spectrometers in Hall C (the new SHMS and existing HMS) will provide precision separated and unseparated cross section measurements and ratios. The new large acceptance CLAS12 spectrometer in Hall B enables measurements over broad regions of phase space. In Hall A, the new SBS spectrometer, used in conjunction with the existing HRS or Big Bite spectrometers will provide access to very large Q2 and allow for measurements requiring both high luminosity and large acceptance. This talk will give an overview of the upcoming experimental program in Halls A,B, and C, in particular highlighting synergies between the hall programs, which will allow Jefferson Lab to maximize the science output its 12 GeV program.

Gaskell, David↗

Topological Hall Effect Anisotropy in Kagome Bilayer Metal Fe 3 Sn 2

Kagome lattice materials attract growing interest for their topological properties and flat-bands in electronic structure. We present comprehensive study on the anisotropy and out-of-plane electric transport in Fe 3 Sn 2 , a metal with bilayer of Fe kagome planes and with massive Dirac fermions that features high-temperature non-collinear magnetic structure and magnetic skyrmions. For the electrical current path along the c-axis, in micron-size crystals, we found a large topological Hall effect (THE) over a wide temperature range down to spin-glass state. Twofold and fourfold angular magnetoresistance are observed for different magnetic phases, reflecting the competition of magnetic interactions and magnetic anisotropy in kagome lattice that preserve robust topological Hall effect for inter kagomebilayer currents. This information provides new insight into the anisotropy in Fe 3 Sn 2 , of interest in skyrmionicbubble application-related micron-size devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Newly designed double surface bimorph mirror for BL-15A of the photon factory

BL-15A is a new x-ray undulator beamline at the Photon Factory. It will be dedicated to two independent research activities, simultaneous XAFS/XRF/XRD experiments, and SAXS/WAXS/GI-SAXS studies. In order to supply a choice of micro-focus, low-divergence and collimated beams, a double surface bimorph mirror was recently developed. To achieve further mirror surface optimization, the pencil beam scanning method was applied for “in-situ” beam inspection and the Inverse Matrix method was used for determination of optimal voltages on the piezoelectric actuators. The corrected beam profiles at every focal spot gave good agreement with the theoretical values and the resultant beam performance is promising for both techniques. Quick and stable switching between highly focused and intense collimated beams was established using this new mirror with the simple motorized stages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NOvA Experiment

The NOνA experiment aims to study the mixing behavior of neutrinos and will attempt to resolve the neutrino mass hierarchy. The experiment will rely on data collected at two detectors, one near Fermilab\'s NuMI (Neutrinos at the Main Injector) target and one 810 km north at Ash River, MN. The detectors are 14 mrad off the beam axis, which results in an almost monoenergetic beam of 2 GeV neutrinos. The construction of the far detector started early this year, the instrumentation will commence this fall, and we hope to take our first data in the beginning of next year. In this talk I will focus on the exciting possibilities of our detector in light of recent neutrino results and will discuss our plans to measure the neutrino mixing angle θ13 as well as to attempt to resolve the neutrino mass hierarchy and to understand the effects of the CP violating phase angle δ. I will also survey the rich physics program provided by our 14 kT fully active far detector, such as searches for magnetic monopoles and detection of supernovaneutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Nb3Sn Cavity Performance Using Centrifugal Barrel Polishing

Nb3Sn superconducting radiofrequency (SRF) cavities have been an ongoing research topic for many years motivated by the potential for higher accelerating gradients and quality factors compared to niobium SRF cavities. The highest performing Nb3Sn cavities are manufactured using tin vapor-diffusion coating, which creates a Nb3Sn film with a surface roughness of around 100-200 nm. This is thought to be one of the limiting factors for the accelerating gradient of Nb3Sn cavities due to enhancement of magnetic field near sharp surface features. To smooth Nb3Sn SRF cavities, we have developed a mechanical polishing procedure which uses centrifugal barrel polishing to smooth the surface followed by a secondary tin coating step to repair the surface. We show that the accelerating field of a Nb3Sn SRF cavity is improved by applying this procedure. We also investigate the quench mechanism of the polished cavity by utilizing temperature mapping to measure which regions of the cavity e xperience heating during RF operation. We then cut samples from these regions and analyze the film microstructure and chemical composition in 3D using EDS and EBSD measurements together with a focused ion-beam (FIB) tomography technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polar Plasma Wave Investigation Data Analysis in the Extended Mission

The low latitude boundary layer (LLBL) is a region where solar wind momentum and energy is transferred to the magnetosphere. Enhanced "broadband" electric plasma waves from less than 5 Hz to l0(exp 5) Hz and magnetic waves from less than 5 Hz to the electron cyclotron frequency are characteristic of the LLBL. Analyses of Polar plasma waves show that these "broadband" waves are actually discrete electrostatic and electromagnetic modes as well as solitary bipolar pulses (electron holes). It is noted that all wave modes can be generated by approx. 100 eV to approx. 10 keV auroral electrons and protons. We will review wave-particle interactions, with focus on cross- diffusion rates and the contributions of such interactions toward the formation of the boundary layer. In summary, we will present a scenario where the global solar wind-magnetosphere interaction is responsible for the auroral zone particle beams, and hence for the generation of plasma waves and the formation of the boundary layer. It is speculated that all planetary magnetospheres will have boundary layers and they will be characterized by similar currents and plasma wave modes.

Gurnett, Donald A.↗

Polar Plasma Wave Investigation Data Analysis in the Extended Mission

The low latitude boundary layer (LLBL) is a region where solar wind momentum and energy is transferred to the magnetosphere. Enhanced "broadband" electric plasma waves from less than 5 Hz to 10(exp 5) Hz and magnetic waves from less than 5 Hz to the electron cyclotron frequency are characteristic of the LLBL. Analyses of Polar plasma waves show that these "broadband" waves are actually discrete electrostatic and electromagnetic modes as well as solitary bipolar pulses (electron holes). It is noted that all wave modes can be generated by approx. 100 eV to approx. 10 keV auroral electrons and protons. We will review wave-particle interactions, with focus on cross-diffusion rates and the contributions of such interactions toward the formation of the boundary layer. In summary, we will present a scenario where the global solar wind-magnetosphere interaction is responsible for the auroral zone particle beams, and hence for the generation of plasma waves and the formation of the boundary layer. It is speculated that all planetary magnetospheres will have boundary layers and they will be characterized by similar currents and plasma wave modes.

Gurnett, Donald A.↗

EPU correction scheme study at the CLS

The Canadian Light Source (CLS) Quantum Materials Spectroscopy Center (QMSC) beamline will employ a novel double period (55 mm, 180 mm) elliptically polarizing undulator (EPU) to produce photons of arbitrary polarization in the soft X-ray regime. The long period and high field of the 180 mm period EPU will have a strong dynamic focusing effect on the storage ring electron beam. We have considered two partial correction schemes, a 4 m long planar array of BESSY-II style current strips, and soft iron L-shims. In this paper we briefly consider the implementation of these correction schemes.

43 PARTICLE ACCELERATORS↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that slow physiological motion can exceed acceptable therapeutic margins. In the animal experiment, motion tracking revealed an initial shift of up to 4 mm during the first 10 min and a subsequent continuous shift of ∼2 mm/h until the end of the intervention. This leads to a continuously increasing mismatch of the initial shot planning, the thermal dose measurements, and the true underlying anatomy. The estimated displacements allowed correcting the planned sonication cell cluster positions to the true target position, as well as the thermal dose estimates during the entire intervention and to correct the nonperfused volume measurement. A spatial coherence of all three is particularly important to assure a confluent ablation volume and to prevent remaining islets of viable malignant tissue. Conclusions: This study proposes a motion correction strategy for displacements resulting from slowly varying physiological motion that might occur during a MR-guided HIFU intervention. The authors have shown that such drifts can lead to a misalignment between interventional planning, energy delivery, and therapeutic validation. The presented volunteer study and in vivo experiment demonstrate both the relevance of the problem for HIFU therapies and the compatibility of the proposed motion compensation framework with the workflow of a HIFU intervention under clinical conditions.

60 APPLIED LIFE SCIENCES↗

First-principles approach to the dynamic magnetoelectric couplings for the non-reciprocal directional dichroism in BiFeO 3

Due to the complicated magnetic and crystallographic structures of BiFeO 3 , its magnetoelectric (ME) couplings and microscopic model Hamiltonian remain poorly understood. By employing a firstprinciples approach, we uncover all possibleMEcouplings associated with the spin-current (SC) and exchange-striction (ES) polarizations, and construct an appropriate Hamiltonian for the long-range spin-cycloid in BiFeO 3 . First-principles calculations are used to understand the microscopic origins of theMEcouplings.Wefind that inversion symmetries broken by ferroelectric and antiferroelectric distortions induce the SC and the ES polarizations, which cooperatively produce the dynamicME effects in BiFeO 3 . A model motivated by first principles reproduces the absorption difference of counter-propagating light beams called non-reciprocal directional dichroism. The current paper focuses on the spin-driven (SD) polarizations produced by a dynamic electric field, i.e. the dynamic MEcouplings. Due to the inertial properties of Fe, the dynamic SD polarizations differ significantly from the static SD polarizations. Our systematic approach can be generally applied to any multiferroic material, laying the foundation for revealing hiddenMEcouplings on the atomic scale and for exploiting opticalMEeffects in the next generation of technological devices such as optical diodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Shot-to-shot reproducibility of a self-magnetically insulated ion diode

In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300-500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250-300 kV). The ion current density was 10-70 A/cm{sup 2} depending on the diode geometry. The beam was composed from carbon ions (80%-85%) and protons. It was found that shot to shot variation in the ion current density was about 35%-40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%-20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact scanning transmission x-ray microscope at the photon factory

We report the design and performance of a compact scanning transmission X-ray microscope developed at the Photon Factory. Piezo-driven linear stages are used as coarse stages of the microscope to realize excellent compactness, mobility, and vibrational and thermal stability. An X-ray beam with an intensity of ∼10{sup 7} photons/s was focused to a diameter of ∼40 nm at the sample. At the soft X-ray undulator beamline used with the microscope, a wide range of photon energies (250–1600 eV) is available. The microscope has been used to research energy materials and in environmental sciences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report: Nanoscale Dynamical Heterogeneity in Complex Magnetic Materials

A magnetic object can be demagnetized by dropping it on a hard surface, but what does ‘demagnetized’ actually mean? In 1919 Heinrich Barkhausen proved the existence of magnetic domains, which are regions of uniform magnetization that are much larger than atoms but much smaller than a macroscopic object. A material is fully magnetized when domain magnetizations are aligned, while it is demagnetized when the domain magnetizations are randomly oriented and the net magnetization is zero. The heterogeneity of a demagnetized object leads to interesting questions. Magnets are unstable when their poles align, and stable when their poles anti-align, so why is the magnetized state ever stable? What do domains look like? What is the structure of a domain wall? How does the magnetized state transform to the demagnetized state? How do domains appear and disappear? What are the statistical properties of domains and how do these vary as the domain pattern evolves? Some of these questions remain the focus of intense study nearly a century after Barkhausen’s discovery. For example, just a few years ago a new kind of magnetic texture called a skyrmion was discovered. A skyrmion is a magnetic domain that is a nanometer-scale, topologically protected vortex. ‘Topologically protected’ means that skyrmions are hard to destroy and so are stable for extended periods. Skyrmions are characterized by integral quantum numbers and are observed to move with little dissipation and so could store and process information with very low power input. Our research project uses soft x-rays, which offer very high magnetic contrast, to probe magnetic heterogeneity and to measure how it evolves in time under external influences. We will condition a soft x-ray beam so that the wave fronts will be coherent, that is, they will be smooth and well-defined. When coherent soft x-ray beam interacts with a magnetic material, the magnetic heterogeneity is imprinted onto the wave fronts and projected into a diffraction pattern. These patterns will be analyzed to understand the structure, motion, and statistical properties of magnetic textures and their boundaries. Over the period covered by this grant we will study a) the structure, phase behaviors, and motion of skyrmions in various thin film materials, and 2) the statistical properties of Barkhausen cascades, which are a key factor in how magnetization varies.

36 MATERIALS SCIENCE↗

Application of the Geant4 Simulation Toolkit to Medical Physics - Paper 65

We show how the Geant4 Simulation Toolkit, originally developed for High Energy Physics, has been applied to a wide variety of challenging applications in medical physics. As the authors are mainly responsible for providing assistance to Geant4 users in North America, they draw on examples from the North American experience, but the conclusions can be generalized to the Geant4 medical user community worldwide. Geant4 is already heavily used in all areas of medical physics, from external beam therapy to brachytherapy to interventional nuclear medicine and medical imaging. As the complexity of medical physics studies continues to increase, requiring greater accuracy of modeling, and an increase in 4D capabilities (component motion and time-varying electric and magnetic fields), Geant4 use will only expand. The openness of the HEP community (keeping Geant4 well supported, open and free) is greatly appreciated by the medical and aerospace communities. The democratic nature of Geant4's governance (that decision-making rests with a technical steering board elected by the collaborators) has given outside communities the confidence to invest their energies in Geant4 (shown them that it is worth the time investment to become expert users). Geant4's latest key area of focus, moving to multithreaded operation, is seen as a huge boon to the medical users (where precision simulations often require billions of primary particles). Another recent key area of Geant4, increasing automated systems for unit and end-to-end testing, is also seen as extremely valuable to these non-HEP communities. Innovations from HEP and aerospace will benefit medical applications, and vice versa. Geant4 can expect increasing resources to be provided by the medical physics community, pooling resources to the benefit of all users. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗