Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Status of the RRR evaluations for 233,235 U and 239 Pu [Slides]

The presentation discusses the R -Matrix Analysis of 233 U, 235 U, and 239 Pu and how their interplay among PFNS, TNC, RRR, and neutron multiplicities has a significant impact on the benchmarks. The presentation also discusses the 233 U improved agreement on benchmarks, an additional investigation on the thickness of beryllium reflectors, work on URR (up to 40 keV) and/or extension of RRR (600 eV to 2 keV). Also discussed is how the 235 U progresses on understanding reactivity rates related to depletion calculations, improved agreement with measured (capture) data is quite insensitive to resolve the negative slope, and how the 239 Pu negative slope as a function of the temperature is not understood yet (bias over 2σ lower than measured).

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of 3D Simulation Capabilities within xRAGE using a Suite of Test Problems

This presentation describes a 3D verification and validation suite for xRAGE. Three verification test problems for hydrodynamics are presented: the Kidder ball problem, the Verney shell problem, and a 5-material compression problem. There is excellent agreement between 2D and 3D XRAGE simulation results for these problems, and between the xRAGE results and the benchmark solutions. In addition, two 3D ICF test problems are presented, based on an OMEGA direct drive capsule experiment, and on a NIF indirect drive capsule experiment. These two ICF test problems are used to evaluate two hydrodynamic methods within xRAGE. In addition to hydrodynamics the simulations also include three temperature plasma physics, thermal conduction and radiation diffusion. When simulating either capsule in 3D the newer unsplit hydrodynamic method in xRAGE produces more vorticity relative to the older default method. For the indirect drive capsule the 3D simulations are in reasonable agreement with the experimental values of ion temperature and neutron production. Unstable 3D vortex rings are present near the DT ice/carbon interface which enhance the confinement of the DT ice.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Nuclear Data Sensitivity Calculations by the MCNP PERT Card [Poster]

This work validates a method of estimating sensitivities that utilized the MCNP PERT card and tallies. The agreement of the PERT card and Brute Force results proves the validity of calculating nuclear data sensitivities by use of the MCNP PERT card, especially at higher energies. The overall agreement will be easier to understand once an uncertainty analysis is completed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the RRR evaluations for 233,235 U and 239 Pu [Slides]

The presentation discusses the R -Matrix Analysis of 233 U, 235 U, and 239 Pu and how their interplay among PFNS, TNC, RRR, and neutron multiplicities has a significant impact on benchmarks. The presentation also discusses the 233 U improved agreement on benchmarks, an additional investigation on the thickness of beryllium reflectors, work on URR (up to 40 keV) and/or extension of RRR (600 eV to 2 keV). Also discussed is how the 235 U progresses on understanding reactivity rates related to depletion calculations, improved agreement with measured (capture) data is quite insensitive to resolve the negative slope, and how the 239 Pu negative slope as a function of the temperature is not understood yet (bias over 2σ lower than measured).

07 ISOTOPE AND RADIATION SOURCES↗

National and Regional Initiatives to Promote Energy Efficiency and Renewable Energy Through State Energy Offices

The National Association of State Energy Officials (NASEO) worked with the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE), Weatherization and Intergovernmental Programs Office (WIP) over a ten year period to provide technical assistance, research and analyses, and enhanced coordination between DOE and the State and Territory Energy Offices. Over the life of the agreement, NASEO worked with WIP and the states to provide statewide strategic energy plan analyses and recommendations, including customized technical assistance to the states; peer to peer financing assistance via NASEO’s Financing Committee and supporting activities; training on core energy policies and programs, including dialogues and resources to support energy-air coordination, a training for new State Energy Office Directors, peer to peer exchange via a rural energy taskforce, and support to states to enhance buildings efficiency, home energy labeling, and technology deployment opportunities; support for State Energy Program metrics; and regional coordination via regional coordinators and peer exchange opportunities both in-person and online. Over the life of the project, the position and role of State Energy Offices within state government has changed, with now 80 percent of State Energy Office Directors serving as their Governor’s energy advisor, or reporting directly to their Governor’s energy advisor. This shift in stature has made it ever more crucial for State Energy Offices to receive timely and relevant technical assistance across a range of energy issue areas. NASEO, in collaboration with WIP, was able to deliver this technical assistance, and energy efficiency and renewable energy deployment has accelerated across the country. The State Energy Office Directors and their staff continue to engage in NASEO’s Committees – many of which were supported through this agreement – and have provided formal and informal feedback on the value of the programs supported through this award (e.g., reporting via survey increased understanding of their roles and technical assistance offerings provided by WIP and NASEO following the New Director Trainings). Moreover, resources developed through this award (e.g., Comprehensive State Energy Planning Guidelines, State Energy Loan Fund Database, Rural Data Resources for State Energy Planning and Programs, The Value of Adding home Energy Score to Low-Income Energy Efficiency Programs, etc.) have been cited by states as instrumental to their understanding of specific energy issue areas and in many cases led directly to enhanced program design within a state (e.g. Iowa citing their review of NASEO’s Comprehensive State Energy Planning Guidelines as a necessary first step in their planning process, later following may of the steps outlined in the guidelines). The priorities of the states and federal government have evolved over the last decade, with an increasing focus on climate mitigation and adaptation, equity impacts and considerations, energy security and resilience, and enhanced energy efficiency and renewable energy technology deployment, but the roots of these new priorities are based in the state and federal policies and programs, and research and analyses, that were supported in part through this award and other complementary initiatives. NASEO looks forward to continuing to support the states, and collaborate and coordinate with DOE, as we build on this important foundation in the years ahead.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Finding of Effect, And Mitigation Documentation for Building 23-620, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15283), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-620 was built in 1968 as office space for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons. In the 1990s, it became a maintenance facility for Reynolds Electrical & Engineering Company (REECo), and eventually, it became the Real Estate Services building in 2004. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-620 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-620 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation Report: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-620 (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) in the Mercury Historic District (MHD, SHPO Resource No. D230). This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2023 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2022, there were 374 hybrid plants (>1 MW) operating across the United States (+25% compared to the end of 2021), totaling nearly 41 GW of generating capacity (+15%) and 5.4 GW/15.2 GWh of energy storage (+69%/+88%). PV+storage plants are by far the most common, dominating in terms of plant number (213), storage capacity (4.0 GW/12.5 GWh), storage:generator capacity ratio (49%), and storage duration (3.1 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was another strong year for PV+storage hybrids in particular: 59 of the 62 hybrids added in 2022 were PV+storage. As of the end of 2022, there was roughly as much storage capacity operating within PV+storage hybrid plants as in standalone storage plants (~4 GW each). In storage energy terms, however, PV+storage edged out standalone storage by ~2 GWh (12.5 GWh vs. 10.4 GWh, respectively). -Interconnection queue data show continued strong developer interest in hybridization. At the close of 2022, there were 51% more hybrid plants—representing 59% more generating capacity—in interconnection queues across the United States than there were at the end of 2021. Solar dominates these proposed plants as well: at the close of 2022, there were 457 GW of solar capacity proposed as a hybrid (representing ~48% of all solar capacity in the queues), most typically pairing PV with battery storage. At the same time, there were 24 GW of wind capacity proposed as a hybrid (representing ~8% of all wind capacity in the queues), again most-often pairing wind with storage. Meanwhile, more than half of all storage in the queues is estimated to be part of a hybrid plant. While many of the plants proposed in the queues will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable, particularly in certain regions. For example, in CAISO, 97% of all solar capacity and 45% of all wind capacity in the queues is proposed as a hybrid. -The report also surveys power purchase agreement (PPA) price data from a sample of operating and proposed PV+storage plants. Though PV+storage PPA prices have fallen over time, “levelized storage adders” have recently increased somewhat to ~$\$ $7000/MW-month, ~$\$ $60/MWh-stored (assuming one full cycle per day), or ~$\$ $15/MWh-PV. Some of the recent price increase could simply reflect a trend towards higher battery:PV capacity ratios over time, which increases costs, all else being equal. The well-publicized impact of inflationary and supply chain pressures on battery prices is no doubt a contributor as well.

25 ENERGY STORAGE↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technologist in Residence for Advanced Manufacturing and Materials in Unconventional Oil and Gas Equipment and Infrastructure

The DOE Technologist in Residence (TIR) program pairs a senior technical staff member from a National Laboratory (Lab Technologist), and a senior technical staff member(s) from a clean energy manufacturing company or consortium of companies (Industry Technologist). Each technologist may represent single or multiple national laboratories, or single or multiple companies. These pairs of Lab and industry technologists work together for a period of 18 to 24 months to accomplish several goals: 1) Identify the participating company’s (or companies’) technical priorities and challenges, and the resources and capabilities in DOE’s National Laboratories that may be highly suitable to address them; 2) Propose collaborative R&D efforts to develop science-based solutions to the company’s (or companies’) most strategic scientific, technological, and business issues; and 3) Develop a general framework agreement and begin developing specific scopes of work for the proposed collaborative R&D efforts. The proposed R&D will then take place outside of the program and will not use TIR program funds. Oak Ridge National Laboratory (ORNL) and Pioneer Natural Resources were awarded a TIR project by DOE in late 2016 and the CRADA component of the project was initiated in 2017. This report describes work performed under the CRADA agreement between 2017 and 2020.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Finding of Adverse Effect and Proposed Mitigation for the Demolition of Building 23-530, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-530 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15270), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-530, a dormitory called Freedom Hall, was constructed in Mercury in 1982 and served as a support facility for nuclear testing for the last decade of the Cold War. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Building 23-530 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-530 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-530 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-530 (Nevada State Historic Preservation Office [SHPO] Resource No. B15270) in the Mercury Historic District (MHD, SHPO Resource No. D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The dormitory is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Finding of No Adverse Effect for the Façade Alteration of Building 23-117, Administration Building, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to update the façade of Building 23-117 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15256), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is to incorporate Building 23-117 into the new Mercury campus in accordance with the master plan for the modernization of Mercury. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-117 was built in 1982 as the architect-engineer Administration Building1 for Holmes & Narver, a government contractor who helped design and engineer the town of Mercury and other areas on the NNSS from its inception until the termination of their contract in 1990. The building continued to be used by subsequent government contractors and is currently still in use by MSTS. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-117 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and is subject to the stipulations of the Mercury PA. The NNSA/NFO requested that Desert Research Institute (DRI), cultural resource subject matter experts, analyze the effects of the proposed project on historic properties in the Area of Potential Effect (APE) and make a recommended finding for the undertaking in accordance with Section 106 of the NHPA and the Mercury PA. The purpose of this letter report is to submit documentation related to the mitigation of the façade alteration of Building 23-117 (Nevada State Historic Preservation Office [SHPO] Resource No. B15256) in the Mercury Historic District (MHD, SHPO Resource No. D230). This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of BISON's Transient Fission Gas Release Model on High-Burnup UO 2 MiniFuel

BISON's fission gas release (FGR) model has been evaluated and tested over several hypothetical thermal transient cases at high burnup and validated against FGR experimental data from an annealing test at high burnup. Diffusion-controlled FGR is accounted for in the model by including several physical mechanisms such as the diffusion of fission gas to grain faces, grain boundary sweeping, grain growth, and intergranular bubble growth. Under temperature variations, FGR is increased due to the development of micro-cracks at grain faces. This existing transient capability, however, was developed based on transient fuel behavior during power ramps and the associated micro-cracking process. Nevertheless, a fraction of the FGR during temperature transients such as LOCA can ensue from different mechanisms (in particular, fuel fragmentation) and present an important dependency on local burnup and high burnup structure formation. It follows that the performance and necessary developments of the existing BISON fission gas model for the analysis of LOCA-type transients need to be investigated through a systematic assessment study. Such a study is performed in this work. The model shows an overall good qualitative agreement with experimental observations on FGR during annealing tests with different temperature conditions. It also accounts well for microstructural effects on FGR. When quantitatively compared to FGR data from previously irradiated 103 MWd/kgU UO 2 discs under thermal annealing, the model shows a less satisfactory agreement with the experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hybrid Interior-Point/Active-Set SCOPF Algorithms Exploiting Power System Characteristics

These protected data were produced under agreement no. with the U.S. Department of Energy and may not be published, disseminated, or disclosed to others outside the Government until 5 years after development of information under this agreement, unless express written authorization is obtained from the recipient. Upon expiration of the period of protection set forth in this Notice, the Government shall have unlimited rights in this data. This Notice shall be marked on any reproduction of this data, in whole or in part.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiation Safety Information Computational Center (RSICC) [Slides]

This presentation touches on the Radiation Safety Information Computational Center (RSICC). This Lecture provides general mission, statistics, and strategies. A general background is provided of the tool. Licensee agreements and export control agreements are discussed. The presentation finishes with a look at the most in demand and requested software packages.

97 MATHEMATICS AND COMPUTING↗