Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The double electrostatic ion ring experiment: A unique cryogenic electrostatic storage ring for merged ion-beams studies

We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate ''rings'' and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.

43 PARTICLE ACCELERATORS↗

Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

43 PARTICLE ACCELERATORS↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

A solid-state Marx generator driven Einzel lens chopper

A new type of pulse chopper called an Einzel lens chopper is described. An Einzel lens placed immediately after an electron cyclotron resonance ion source is driven by high-voltage pulses generated by a newly developed solid-state Marx generator. A rectangular negative barrier pulse-voltage is controlled in time, and the barrier pulse is turned on only when a beam pulse is required. The results of successful experiments are reported herein.

43 PARTICLE ACCELERATORS↗

Imaging single electrons to enable the generation of ultrashort beams for single-shot femtosecond relativistic electron diffraction

The generation and control of relativistic electron beams well suited for ultrafast electron diffraction application has rapidly advanced, greatly benefiting from the overlap in techniques and expertise with the accelerator community. However, imaging the diffracted MeV electrons with high detection efficiency has remained an under-explored area. In this paper, we report on a quantitative study of the imaging of MeV electrons using a detection system consisting of a phosphor screen, a lens-coupling optics, and a charge-coupled device camera. It is shown that every MeV electron in the beam yields a signal well above the camera noise. With this detection efficiency, only {approx}10{sup 5} electrons per pulse are needed to obtain a high quality single-shot diffraction pattern from a crystalline sample. We measured that such a low charge beam can be as short as 30 fs rms. Further, we discuss the possibility of compressing these electron beams to sub-5 fs rms bunch length by velocity bunching using a short high gradient rf accelerating structure scheduled to be installed next year at the UCLA Pegasus Laboratory. This opens the possibility of single-shot determinations of structural changes in many ultrafast physical processes like nonequilibrium phonon dynamics or relaxation pathways in systems with strong electron-phonon coupling.

43 PARTICLE ACCELERATORS↗

Extraction of the Compton Form Factor H from DVCS Measurements in the Quark Sector

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A, the beam spin asymmetries measured in Hall B at Jefferson Laboratory and beam charge, beam spin and target spin asymmetries measured by Hermes. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20-50 % uncertainty. We pay extra attention to the estimation of systematic errors on the extraction of H. We discuss our results and compare to other extractions as well as to the popular VGG model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of double spin asymmetry A{sub LT} in semi-inclusive pion electroproduction on a transversely polarized {sup 3}He target

The double spin asymmetry A{sub LT} for {sup 3}He was measured for the first time at Jefferson Lab Hall A in the semi-inclusive {sup 3}He{up_arrow}({sup {yields}e},{pi}{sup +/-}X reactions, using a 6 GeV polarized electron beam on a transversely polarized {sup 3}He target. The produced charged pions were detected in coincidence with the scattered electrons by the high-resolution spectrometer and the BigBite spectrometer, respectively. The kinematic coverage was focused on the valence quark region, x {approx} 0.13-0.41, Q{sup 2}{approx} 1.31-3.10 (GeV/c){sup 2}. When combined with the world data, this new data will provide constraints on the g{sub 1T}{sup q} distribution functions, which describe the longitudinal polarization of quarks in a transversely polarized nucleon. The status of the current analysis and the preliminary results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin physics with CLAS and CLAS12

An extensive experimental program to measure the spin structure of the nucleon has been conducted in Hall B at Jefferson Lab with the CEBAF Large Acceptance Spectrometer (CLAS) in the last decade. Using a longitudinally polarized beam scattering off longitudinally polarized NH{sub 3} and ND{sub 3} targets, inclusive Deep Inelastic Scattering (DIS), Semi-Inclusive DIS (SIDIS) and DVCS experiments were carried out that make a significant contributions to the existing data. The inclusive double spin asymmetry A{sub ||} was measured over a large range in Q{sup 2} and W, providing data of impressively high precision that give a better understanding of the structure of the nucleon in the DIS and the valence quarks regions. Using parameterizations A2 and F1 from world data, the virtual photon asymmetry A1 and the structure function g1 were extracted in a Q{sup 2} range from 0.05 to 5 GeV{sup 2} and a W range from 1.08 to 3.0 GeV. As a result of the extended kinematical range, first moments of structure functions were measured over a large range in Q{sup 2} and duality was tested. Furthermore, newly proposed experiments, using an upgraded accelerator at Jefferson Laboratory and an improved CLAS detector (CLAS12), are expected to increase the statistical precision of the current measurements and extend them to kinematic regions presently not accessible, such as high x. This will improve significantly our knowledge of the structure of the nucleon, including parton distribution functions, duality and higher twists contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration method of tilt and azimuth angles for alignment of TEM tomographic tilt series

This paper describes the calibration method of the tilt and azimuth angles of specimen using a digital protractor and a laser autocollimator for alignment of electron tomography. It also suggests an easy method to check whether the specimen is tilted by 180.0 deg., and whether the azimuth angle is 0.0 deg.; the method involves the use of two images of a rod-shaped specimen collected before and after a 180.0 deg. The method is based on the assumption that these images are symmetric about the tilt axis when the azimuth angle is 0.0 deg. In addition, we used an experiment to demonstrate the effect of the incorrect angles on reconstructed images and simulated the image quality against distance away from tilt axis.

43 PARTICLE ACCELERATORS↗

Optimizing the front end test stand high performance H{sup -} ion source at RAL

The aim of the front end test stand project is to demonstrate that chopped low energy H{sup -} beams of high quality can be produced. The beam line currently consists of the ion source, a 3 solenoid low energy beam transport and a suite of diagnostics. A brief status report of the radio frequency quadrupole is given. This paper details the work to optimize the ion source performance. A new high power pulsed discharge power supply with greater reliability has been developed to allow long term, stable operation at 50 Hz with a 60 A, 2.2 ms discharge pulse and up to 100 A at 1.2 ms. The existing extraction power supply has been modified to operate up to 22 kV. Results from optical spectroscopy measurements and their application to source optimization are summarized. Source emittances and beam currents of 60 mA are reported.

43 PARTICLE ACCELERATORS↗

Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

43 PARTICLE ACCELERATORS↗

Measuring the NuMI Beam Flux for MINERvA

MINERvA is employing multiple tools to understand its neutrino beam flux. We utilize external hadron production data, but we also depend heavily on in situ techniques in which we reduce our hadron production uncertainties by tuning our Monte Carlo to both MINERvA detector data and muon monitor data.

43 PARTICLE ACCELERATORS↗

The second generation Singapore high resolution proton beam writing facility

A new proton beam focusing facility, designed for proton beam writing (PBW) applications has been tested. PBW allows for proximity free structuring of high aspect ratio, high-density 3D nanostructures. The new facility is designed around OM52 compact quadrupole lenses capable of operating in a variety of high demagnification configurations. Performance tests show that proton beams can be focused down to 19.0 x 29.9 nm{sup 2} and single line scans show a beam width of 12.6 nm. The ultimate goal of sub 10 nm structuring with MeV protons will be discussed.

43 PARTICLE ACCELERATORS↗

X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source

X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron sources to non-coherent conventional x-ray tube sources. Here, we present the first installation of a three grating x-ray interferometer at a low-coherence wiggler source at the beamline W2 (HARWI II) operated by the Helmholtz-Zentrum Geesthacht at the second-generation synchrotron storage ring DORIS (DESY, Hamburg, Germany). Using this type of the wiggler insertion device with a millimeter-sized source allows monochromatic phase-contrast imaging of centimeter sized objects with high photon flux. Thus, biological and materials-science imaging applications can highly profit from this imaging modality. The specially designed grating interferometer currently works in the photon energy range from 22 to 30 keV, and the range will be increased by using adapted x-ray optical gratings. Our results of an energy-dependent visibility measurement in comparison to corresponding simulations demonstrate the performance of the new setup.

43 PARTICLE ACCELERATORS↗

Development of an Accelerator Mass Spectrometer based on a Cyclotron

An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

43 PARTICLE ACCELERATORS↗

Light ion source for proton/deuteron production at CEA Saclay for the Spiral2 project

The production of rare radioactive ion beam (RIB) far from the valley of stability is one of the final purposes of the Spiral2 facility in Caen. The RIB will be produced by impinging a deuteron beam onto a carbon sample to produce a high neutron flux, which will interact with a uranium target. The primary deuteron beam is produced by an ion source based on ECR plasma generation. The deuteron source and the low energy beam transport (LEBT) has been assembled and tested at CEA Saclay. Diagnostics from other laboratories were implemented on the LEBT in order to characterize the deuteron beam produced and compare it to the initial simulations. The ion source has been based on a SILHI-type source, which has demonstrated good performances in pulsed and continuous mode, and also a very good reliability on long term operation. The 5 mA of deuteron beam required at the RFQ entrance is extracted from the plasma source at the energy of 40 kV. After a brief description of the experimental set-up, this article reports on the first beam characterization experiments.

43 PARTICLE ACCELERATORS↗

Ion optics of RHIC electron beam ion source

RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗