Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablatives Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Postflight aerothermodynamic analysis of Pegasus(tm) using computational fluid dynamic techniques

The objective was to validate the computational capability of the NASA Ames Navier-Stokes code, F3D, for flows at high Mach numbers using comparison flight test data from the Pegasus (tm) air launched, winged space booster. Comparisons were made with temperature and heat fluxes estimated from measurements on the wing surfaces and wing-fuselage fairings. Tests were conducted for solution convergence, sensitivity to grid density, and effects of distributing grid points to provide high density near temperature and heat flux sensors. The measured temperatures were from sensors embedded in the ablating thermal protection system. Surface heat fluxes were from plugs fabricated of highly insulative, nonablating material, and mounted level with the surface of the surrounding ablative material. As a preflight design tool, the F3D code produces accurate predictions of heat transfer and other aerodynamic properties, and it can provide detailed data for assessment of boundary layer separation, shock waves, and vortex formation. As a postflight analysis tool, the code provides a way to clarify and interpret the measured results.

Kuhn, Gary D.↗

Real Gas/Blunt Cone

In this chapter recent activity in real-gas database definition and code validation will be summarized. In the Phase I report of the Working Group (WG) 181, aerothermodynamic problems were classified, for purpose of discussion, into seven types: aerodynamic parameters, viscous/shock interaction, boundary-layer transition, forebody-heating/heat-transfer, radiation and ablation, lee and base-region flow, and low-density flow. Several of these problem types were the subject of various chapters of the Phase 1 report describing real-gas effects and ground test facility issues. In this chapter some background and objectives outlined in the real-Gas effects Chapter V of the Phase 1 report will be reviewed. The results of the blunt cone test campaign developed under the auspices of the WG18 activity to study real-gas phenomena will be summarized, including the experimental and computational programs, issues and questions, and recommendations. Further, recent progress in other real-gas areas beyond the blunt cone test campaign will be discussed. Finally, a summary in which the present status of our understanding of real-gas issues will be presented.

George S. Delwert↗

Ares: A Coupling Methodology for Ablation Modeling

To enable modeling of complex and coupled ablation problems, a multi-physics framework is developed. A methodology for modeling shape change in coupled systems is presented. The approach taken to model gas-surface interactions and translate coupled surface phenomena to physically meaningful boundary conditions in the distinct solvers is discussed. Particular emphasis is placed on the nature of coupled boundary conditions pertaining to surface energy and mass balances as well as surface chemistry modeling. The developed methodology is used to simulate a shear test in arc-jet conditions in order to assess the validity of the coupled approach as well as the implementation of the relevant physical processes.

EDL↗

Treatment of Metastatic Lymph Nodes in the Neck from Papillary Thyroid Carcinoma with Percutaneous Laser Ablation

PurposeTo assess the effectiveness of percutaneous laser ablation (PLA) of cervical lymph node metastases from papillary thyroid carcinoma.Materials and Methods24 patients (62.3 ± 13.2 year; range 32–80) previously treated with thyroidectomy, neck dissection, and radioiodine ablation underwent ultrasound-guided PLA of 46 {sup 18}FDG-PET/CT—positive metachronous nodal metastases. All patients were at high surgical risk or refused surgery and were unsuitable for additional radioiodine ablation. A 300 µm quartz fiber and a continuous-wave Nd-YAG laser operating at 1.064 mm were used. Technical success, rate of complications, rate of serological conversion, and local control at follow-up were derived. Fisher’s exact test and Mann–Whitney U test were used and Kaplan–Meier curve calculated.ResultsTechnical success was obtained in all 46 lymph nodes (100 %). There were no major complications. Thyroglobulin levels decreased from 8.40 ± 9.25 ng/ml before treatment to 2.73 ± 4.0 ng/ml after treatment (p = 0.011), with serological conversion in 11/24 (45.8 %) patients. Overall, local control was obtained in 40/46 (86.9 %) lymph nodes over 30 ± 11 month follow-up, with no residual disease seen at imaging in 19/24 (79.1 %) patients. Local control was achieved in 40/46 (86.9 %) lymph nodes at 1 year and in all of the 25 nodes (100 %) followed for 3 years. Estimated mean time to progression was 38.6 ± 2.7 m.ConclusionUltrasound-guided PLA is a feasible, safe, and effective therapy for the treatment of cervical lymph node metastases from papillary thyroid carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Testing of a Green-Propellant Micro-Hybrid Thruster with Electrostatic Ignition

As early as 1937 German scientists at Peenemunde experimented with highly unstable fuel blends of nitrous oxide (N2O) and ethanol. These early tests mostly resulted in explosions and destroyed rocket engines. More recently several companies have developed experimental nitrous oxide fuel blends (NOFB) with Isp exceeding 300 sec. Although NOFBx has recently been cleared for tests on the International Space Station, this propellant remains highly experimental and has not been cleared for commercial transport by the US DOT. Recent work by Karabeyoglu et al. has raised concerns about the safety risks of mixing hydrocarbons with N2O. Liquid oxidizer/fuel blends are highly explosive and require extreme care in transport and servicing. By adding small amounts of a liquid organic fuel such as alcohol or a hydrocarbon, the odds of an explosive decomposition event are significantly increased.iv The proposed solution mitigates the explosion hazards of NOFB by separating the oxidizer from the hydrocarbon fuel formed as of a small cylindrical section of ABS thermoplastic. As N2O vapor flows across the grain segment, current enters a 1000 VDC high-tension lead in the ABS fuel grain and produces an inductive spark that vaporizes a small amount of the material. The ablated fuel vapor plus residual energy from the spark seed a localized exothermic N2O dissociation that produces sufficient heat to initiate combustion. The process is also effective when gaseous oxygen is used. A low TRL (2-3) prototype demonstrating the feasibility of controlled hydrocarbon-seeding was recently tested at Utah State University.v The unit features a miniature 2.5 cm ABS fuel grain fabricated using a Stratasys Dimension 3-D printer. The 9-N thruster was pulse-fired up to 27 consecutive times on a single ABS grain segment. Ignition was achieved by as little as 12-15 Joules energy input. This value is contrasted with the typical 30-minute pre-heat requirement for the ECAPS LMP-103S ADN-based monopropellant, requiring an energy input of 14,850 Joules for catalytic dissociation. The hydrocarbon-seeded micro-hybrid was also adapted as a non-pyrotechnic ignitor for a 900 N (200-lbf) thrust hybrid motor. The motor was successfully ignited 4 consecutive times with no hardware swaps or propellant additions. The amount of ABS seed material that can be fit into the injector cap is the only limit to the number of available repeat firings. This series of tests marks the first time a hybrid motor was ever ignited by other than a solid-propellant pyrotechnic charge or bi-propellant flame ignitor. Nitrous oxide hybrid motors are typically difficult to ignite and usually require multiple solid-propellant charges to initiate combustion, so this nonpyrotechnic ignition is a significant accomplishment. The controlled hydrocarbon-seeding approach is fundamentally different from all other green propellant solutions offered by the aerospace industry. Although the proposed system is more correctly a hybrid technology; the system retains all the simple features of a monopropellant design. To date no optimization study has been performed to identify the best grain geometry for electrostatic ignition. Fortunately, because the grain segments are fabricated using rapid-prototyping technology, changing the grain geometry is as simple as modifying the 3-D printer CAD-file. Vacuum Isp exceeding 270 seconds has been demonstrated (Ref v), a value significantly higher than those offered by competing green monopropellant options. The propellants of choice, N2O/GOX and ABS are 100% non-toxic, non-explosive, and environmentally benign. Because the inert oxidizer and fuel components are mixed only within the combustion chamber, the system retains the inherent safety of a hybrid rocket and can be piggy-backed as a secondary payload with no overall mission risk increase to the primary payload, an excellent characteristic for secondary launch systems.

Whitmore, Stephen A.↗

Development of the Algol III solid rocket motor for SCOUT.

The design and performance of a motor developed for the first stage of the NASA SCOUT-D and E launch vehicles are discussed. The motor delivers a 30% higher total impulse and a 35 to 45% higher payload mass capability than its predecessor, the Algol IIB. The motor is 45 in. in diameter, has a length-to-diameter ratio of 8:1 and delivers an average 100,000-lb thrust for an action time of 72 sec. The motor design features a very high volumetrically loaded internal-burning charge of 17% aluminized polybutadiene propellant, a plasma-welded and heat-treated steel alloy case, and an all-ablative plastic nose liner enclosed in a steel shell. The only significant development problem was the grain design tailoring to account for erosive burning effects which occurred in the high-subsonic-Mach-number port. The tests performed on the motor are described.

Felix, B. R.↗

Ablation of ATJ Graphite at High Temperatures

Results of an extensive experimental program on the ablation of ATJ graphite in air at surface pressures of 0.3 to 4.4 atm and surface temperatures of 2570 to 4030 K are presented. The measured mass-loss rates are correlated with surface temperature, pressure, and effective nose radius. The results are compared with several equilibrium thermochemical ablation theories which differ basically in the chemical species that are considered and in the thermodynamic properties assigned to these species. All the theories predict about the same mass-loss rate in the diffusion-controlled oxidation regime and are in good agreement with the experimental results. At higher temperatures, however, the experimental and theoretical results do not agree. At temperatures above 3700 K, the experimental mass-loss rate becomes independent of pressure and an exponential function of temperature. A comparison of the high-temperature results with the theories indicates that all the theories, except the one based on the thermodynamic properties from the JANAF tables, are invalid because they overpredict the mass-loss rate. On the other hand, the theory based on the JANAF properties underpredicts the measured mass-loss rate by a factor of three at 4000 K. At least a portion of this difference between experiment and theory is attributed to particulate mass loss which is visually observed.

Thermochemical ablation↗

Orion Heat Shield Manufacturing Producibility Improvements for the EM-1 Flight Test Program

This paper describes how the Orion program is incorporating improvements in the heat shield design and manufacturing processes reducing programmatic risk and ensuring crew safety in support of NASA’s Exploration Missions. The Orion program successfully completed the EFT-1 flight test in 2014 and is currently developing the EM-1 spacecraft to meet the test objectives of an orbital mission to the moon and return to earth in 2019. Lessons learned from the EFT-1 manufacturing and flight test experience are being incorporated into a wide variety of vehicle systems and manufacturing processes to reduce risk to the Orion missions and flight crew. A critical contributor to crew safety is the heat shield that protects the crew capsule during re-entry through the earth’s atmosphere for return from deep space. The first flight test vehicle, EFT-1, was manufactured and tested in the Neil Armstrong Operations and Checkout (O&C) facility at KSC to demonstrate early risk reduction including the functionality of the Thermal Protection Systems (TPS) for capsule safe return to earth. The approach for the EFT-1 heat shield utilized a low risk approach using Apollo heritage design and manufacturing processes using an Avcoat TPS ablator with a honeycomb substrate to provide a one piece heat shield to meet the mission re-entry heating environments. The manufacturing processes used honeycomb cell injection guns which were redeveloped from the Apollo Lunar Program processes to build the EFT-1 heat shield. The completed heat shield was transported across the country by aircraft to the O&C at KSC for installation onto the capsule. The EFT-1 heat shield successfully performed its mission and experienced ~80% of the re-entry velocity (50% heating rate) for a lunar return for an Exploration Mission. The second flight test vehicle is the EM-1 mission which will have additional flight systems installed to fly to the moon and return. Heat shield design and producibility improvements have been incorporated in the EM-1 vehicle to meet deep space mission and programmatic requirements. The design continues to use the Avcoat material, but in a “block” configuration to enable improvements in the application processes as well as additional improvements in the carrier structure design and manufacturing operations. Incorporating flight test results and producibility improvements from EFT-1 for the heat shield system design and processes have improved the thermal protection capability, improved the producibility, and cost for EM-1 flight test.

Producibility↗

Effect of macular ablation on frequency and latency of motion-induced emesis in the squirrel monkey

Three previously motion-emetic sensitive squirrel monkeys were rendered refractory to a standard motion-emetic regimen by a two-stage utriculosacculectomy procedure which preserved the cristae ampullares of semicircular canals. Three nonoperated control squirrel monkeys tested on the same motion-emetic regimen time schedule as the operated animals remained motion-emetic sensitive with regard to incidence, frequency, and latency of motion-induced emetic responses. Following a sham surgical procedure (stapedectomy) performed on two of the latter animals and one additional new animal, the emetic incidence decreased from 100 to 89 percent, but the frequency and latency were not altered significantly.

Brizzee, Kenneth R.↗

Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089{+-}0.0003 ppm/ deg. C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80 deg. C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver

Purpose: Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). Methods: A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. Results: The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. Conclusions: Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer’s specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.

60 APPLIED LIFE SCIENCES↗

A Relief Zone Architecture for Enhanced Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature cell failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) are prepared with ultra-thin (= 15 micrometer-thick) polymer electrolyte membranes (PEMs). These high-performance PEMs are susceptible to mechanical degradation from stress concentrations arising from component and device-level integration. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating excess and non-uniform compression across the active area. Relief zones, created through the ablation of carbonaceous diffusion material achieves a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. This concept was demonstrated using fuel cells as a case study. Accelerated stress test (AST) validations yielded a 6-fold improvement for MEAs prepared with relief zones (i.e., lifetime approximately 1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.

14 SOLAR ENERGY↗

Solid-propellant motors for high-incremental-velocity low-acceleration maneuvers in space

The applicability of solid-propellant rockets into a regime of high-performance long-burning tasks beyond the capability of existing motors is discussed. Successful static test firings have demonstrated the feasibility of: (1) utilizing fully case-bonded end-burning propellant charges without mechanical stress relief; (2) using an all-carbon radiative nozzle markedly lighter than the flight-weight ablative nozzle it replaces, and (3) producing low spacecraft acceleration rates during the thrust transient through a controlled-flow igniter that promotes operation below the previous combustion limit.

Shafer, J. I.↗

Experimental studies of radiative base heating of a Jovian entry model

A scale model of the Jovian entry vehicle of 6.4 cm diameter is tested in an electric-arc-driven shock tube while a sphere model of 5 cm diameter is tested in a combustion-driven shock tube and an electric-arc-driven shock tunnel. The radiative heat-transfer rate and pressure on the front and the base regions are measured in the absence of ablation with sensors imbedded in the models in a stream consisting of 10% hydrogen in a bath of either neon or argon. The measured radiative heat-transfer rates and pressures are up to about 22 kW/sq cm and 12 atm, respectively, at the front stagnation point. The ratio of the base-to-stagnation-point radiative heat-transfer rates is found to be about 1/4 for the sphere at Mach 1.8, about 1/30 for the sphere at Mach 4.8, and about 1/6 for the scale model at Mach 1.7. When the effects of model geometry and Mach number are accounted for, the present experimental results agree well with the theoretical prediction of Park.

Shirai, H.↗

AV3V lesions attenuate the cardiovascular responses produced by blood-borne excitatory amino acid analogs

Systemic injections of the excitatory amino acid (EAA) analogs, kainic acid (KA) and N-methyl-D-aspartate (NMDA), produce a pressor response in conscious rats that is caused by a centrally mediated activation of sympathetic drive and the release of arginine vasopressin (AVP). This study tested the hypothesis that the tissue surrounding the anteroventral part of the third ventricle (AV3V) plays a role in the expression of the pressor responses produced by systemically injected EAA analogs. Specifically, we examined whether prior electrolytic ablation of the AV3V region would affect the pressor responses to KA and NMDA (1 mg/kg iv) in conscious rats. The KA-induced pressor response was smaller in AV3V-lesioned than in sham-lesioned rats (11 +/- 2 vs. 29 +/- 2 mmHg; P < 0.05). After ganglion blockade, KA produced a pressor response in sham-lesioned but not AV3V-lesioned rats (+27 +/- 3 vs. +1 +/- 2 mmHg; P < 0.05). The KA-induced pressor response in ganglion-blocked sham-lesioned rats was abolished by a vasopressin V1-receptor antagonist. Similar results were obtained with NMDA. The pressor response to AVP (10 ng/kg iv) was slightly smaller in AV3V-lesioned than in sham-lesioned ganglion-blocked rats (45 +/- 3 vs. 57 +/- 4 mmHg; P < 0.05). This study demonstrates that the pressor responses to systemically injected EAA analogs are smaller in AV3V-lesioned rats. The EAA analogs may produce pressor responses by stimulation of EAA receptors in the AV3V region, or the AV3V region may play an important role in the expression of these responses.

Non-NASA Center↗

Molecular Basis for Enhancement of the Meiotic DMCI Recombinase by RAD51AP1

Homologous recombination is needed for meiotic chromosome segregation, genome maintenance, and tumor suppression. RAD51AP1 (RAD51 Associated Protein 1) has been shown to interact with and enhance the recombinase activity of RAD51. Accordingly, genetic ablation of RAD51AP1 leads to enhanced sensitivity to and also chromosome aberrations upon DNA damage, demonstrating a role for RAD51AP1 in mitotic homologous recombination. Here we show physical association of RAD51AP1 with the meiosis-specific recombinase DMC1 and a stimulatory effect of RAD51AP1 on the DMC1-mediated D-loop reaction. Mechanistic studies have revealed that RAD51AP1 enhances the ability of the DMC1 presynaptic filament to capture the duplex DNA partner and to assemble the synaptic complex, in which the recombining DNA strands are homologously aligned. We also provide evidence that functional co-operation is dependent on complex formation between DMC1 and RAD51AP1, and that distinct epitopes in RAD51AP1 mediate interactions with RAD51 and DMC1. Finally, we show that RAD51AP1 is expressed in mouse testes, and that RAD51AP1 foci co-localize with a subset of DMC1 foci in spermatocytes. These results suggest that RAD51AP1 also serves an important role in meiotic homologous recombination.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Advanced Ablative Carbon Phenolic TPS for Future NASA Missions and Commercial Space

Phenolic Impregnated Carbon Ablator (PICA) is a low-density carbon phenolic ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flagship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars lander missions such as MSL and Mars 2020. Continued development of a mass efficient, compliant version of PICA that use a carbon felt as the substrate will be presented. The felt based versions of PICA known as Conformal PICA (C-PICA) is comparable in terms of peak heat-flux capabilities compared to standard PICA. Additionally, a novel all felt PICA-Flex offers further reductions in density, with higher thermal protection efficiency resulting in additional mass savings beyond C-PICA. Furthermore, the compliant nature of these materials allows for application without Strain Isolation Pad to a wide variety of substrates, making attractive for commercial low earth orbit missions as well as NASA’s aerocapture missions to Ice Giants. NASA is currently working with several commercial partners (Varda and Inversion Space) to Technology Transfer C/S-PICA variants for commercial LEO missions. Preliminary thermal and mechanical tests have been conducted comparing the performance of Conformal and Soft-PICA and PICA-Flex materials.

Flexible Ablative TPS↗