Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANDERSON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Terahertz Second-Harmonic Generation from Lightwave Acceleration of Symmetry-Breaking Nonlinear Supercurrents

We report terahertz (THz) light-induced second harmonic generation, in superconductors with inversion symmetry that forbid even-order nonlinearities. The THz second harmonic emission vanishes above the superconductor critical temperature and arises from precession of twisted Anderson pseudospins at a multicycle, THz driving frequency that is not allowed by equilibrium symmetry. We explain the microscopic physics by a dynamical symmetry breaking principle at sub-THz-cycle by using quantum kinetic modeling of the interplay between strong THz-lightwave nonlinearity and pulse propagation. In this work, the resulting nonzero integrated pulse area inside the superconductor leads to light-induced nonlinear supercurrents due to subcycle Cooper pair acceleration, in contrast to dc-biased superconductors, which can be controlled by the band structure and THz driving field below the superconducting gap.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flat Bands in Magic-Angle Bilayer Photonic Crystals at Small Twists

The new physics of magic-angle twisted bilayer graphene (TBG) motivated extensive studies of flat bands hosted by moiré superlattices in van der Waals structures, inspiring the investigations into their photonic counterparts with potential applications including Bose-Einstein condensation. However, correlation between photonic flat bands and bilayer photonic moiré systems remains unexplored, impeding further development of moiré photonics. In this work, we formulate a coupled-mode theory for low-angle twisted bilayer honeycomb photonic crystals as a close analogy of TBG, discovering magic-angle photonic flat bands with a non-Anderson-type localization. Moreover, the interlayer separation constitutes a convenient degree of freedom in tuning photonic moiré bands without high pressure. Furthermore, a phase diagram is constructed to correlate the twist angle and separation dependencies to the photonic magic angles. Our findings reveal a salient correspondence between fermionic and bosonic moiré systems and pave the avenue toward novel applications through advanced photonic band or state engineering.

36 MATERIALS SCIENCE↗

Fixed Depth Hamiltonian Simulation via Cartan Decomposition

Simulating quantum dynamics on classical computers is challenging for large systems due to the significant memory requirements. Simulation on quantum computers is a promising alternative, but fully optimizing quantum circuits to minimize limited quantum resources remains an open problem. In this study, we tackle this problem by presenting a constructive algorithm, based on Cartan decomposition of the Lie algebra generated by the Hamiltonian, which generates quantum circuits with time-independent depth. We highlight our algorithm for special classes of models, including Anderson localization in one-dimensional transverse field $\mathrm{XY}$ model, where $\mathscr{O}$(n 2 )-gate circuits naturally emerge. Compared to product formulas with significantly larger gate counts, our algorithm drastically improves simulation precision. In addition to providing exact circuits for a broad set of spin and fermionic models, our algorithm provides broad analytic and numerical insight into optimal Hamiltonian simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emergent Glassy Behavior in a Kagome Rydberg Atom Array

Here, we present large-scale quantum Monte Carlo simulation results on a realistic Hamiltonian of kagome-lattice Rydberg atom arrays. Although the system has no intrinsic disorder, intriguingly, our analyses of static and dynamic properties on large system sizes reveal emergent glassy behavior in a region of parameter space located between two valence bond solid phases. The extent of this glassy region is demarcated using the Edwards-Anderson order parameter, and its phase transitions to the two proximate valence bond solids—as well as the crossover towards a trivial paramagnetic phase—are identified. We demonstrate the intrinsically slow (imaginary) time dynamics deep inside the glassy phase and discuss experimental considerations for detecting such a quantum disordered phase with numerous nearly degenerate local minima. Our proposal paves a new route to the study of real-time glassy phenomena and highlights the potential for quantum simulation of a distinct phase of quantum matter beyond solids and liquids in current-generation Rydberg platforms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Kondo Lattice Model of Magic-Angle Twisted-Bilayer Graphene: Hund’s Rule, Local-Moment Fluctuations, and Low-Energy Effective Theory

For this work, we apply a generalized Schrieffer-Wolff transformation to the extended Anderson-like topological heavy fermion (THF) model for the magic-angle (θ=1.05°) twisted bilayer graphene (MATBLG) [Phys. Rev. Lett. 129, 047601 (2022)], to obtain its Kondo lattice limit. In this limit localized $\mathcal{f}$ electrons on a triangular lattice interact with topological conduction $\mathcal{c}$ electrons. By solving the exact limit of the THF model, we show that the integer fillings ν=0, ±1, ±2 are controlled by the heavy $\mathcal{f}$ electrons, while ν=±3 is at the border of a phase transition between two $\mathcal{f}$-electron fillings. For ν=0, ±1, ±2, we then calculate the Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions between the $\mathcal{f}$ moments in the full model and analytically prove the SU(4) Hund’s rule for the ground state which maintains that two $\mathcal{f}$ electrons fill the same valley-spin flavor. Our (ferromagnetic interactions in the) spin model dramatically differ from the usual Heisenberg antiferromagnetic interactions expected at strong coupling. We show the ground state in some limits can be found exactly by employing a positive semidefinite “bond-operators” method. We then compute the excitation spectrum of the $\mathcal{f}$ moments in the ordered ground state, prove the stability of the ground state favored by RKKY interactions, and discuss the properties of the Goldstone modes, the (reason for the accidental) degeneracy of (some of) the excitation modes, and the physics of their phase stiffness. We develop a low-energy effective theory for the $\mathcal{f}$ moments and obtain analytic expressions for the dispersion of the collective modes. We discuss the relevance of our results to the spin-entropy experiments in TBG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BCS-BEC Crossover in a Random External Potential

We investigate the ground state properties of a disordered superfluid Fermi gas across the BCS-BEC (Bose-Einstein condensate) crossover. We show that, for weak disorder, both the depletion of the condensate fraction of pairs and the normal fluid density exhibit a nonmonotonic behavior as a function of the interaction parameter 1/k{sub F}a, reaching their minimum value near unitarity. We find that, moving away from the weak-coupling BCS regime, Anderson's theorem ceases to apply and the superfluid order parameter is more and more affected by the random potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First-principles calculation of spin-orbit torque in a Co/Pt bilayer

The angular dependence of spin-orbit torque in a disordered Co/Pt bilayer is calculated using a first-principles nonequilibrium Green's function formalism with an explicit supercell averaging over Anderson disorder. In addition to the usual dampinglike and fieldlike terms, the odd torque contains a sizable planar Hall-like term (m∙E)m × (z × m) whose contribution to current-induced damping is consistent with experimental observations. The dampinglike and planar Hall-like torquances depend weakly on disorder strength, while the fieldlike torquance declines with increasing disorder. The torques that contribute to damping are almost entirely due to spin-orbit coupling on the Pt atoms, but the fieldlike torque does not require it.

36 MATERIALS SCIENCE↗

Gutzwiller hybrid quantum-classical computing approach for correlated materials

Rapid progress in noisy intermediate-scale quantum (NISQ) computing technology has led to the development of novel resource-efficient hybrid quantum-classical algorithms, such as the variational quantum eigensolver (VQE), that can address open challenges in quantum chemistry, physics, and material science. Proof-of-principle quantum chemistry simulations for small molecules have been demonstrated on NISQ devices. While several approaches have been theoretically proposed for correlated materials, NISQ simulations of interacting periodic models on current quantum devices have not yet been demonstrated. Here, we develop a hybrid quantum-classical simulation framework for correlated electron systems based on the Gutzwiller variational embedding approach. We implement this framework on Rigetti quantum processing units (QPUs) and apply it to the periodic Anderson model, which describes a correlated heavy electron band hybridizing with noninteracting conduction electrons. Our simulation results quantitatively reproduce the known ground state quantum phase diagram including metallic, Kondo and Mott insulating phases. This is the first fully self-consistent hybrid quantum-classical simulation of an infinite correlated lattice model executed on QPUs, demonstrating that the Gutzwiller hybrid quantum-classical embedding framework is a powerful approach to simulate correlated materials on NISQ hardware. This benchmark study also puts forth a concrete pathway towards practical quantum advantage on NISQ devices.

36 MATERIALS SCIENCE↗

Error mitigation in variational quantum eigensolvers using tailored probabilistic machine learning

Quantum computing technology has the potential to revolutionize the simulation of materials and molecules in the near future. A primary challenge in achieving near-term quantum advantage is effectively mitigating the noise effects inherent in current quantum processing units (QPUs). This challenge is also decisive in the context of quantum-classical hybrid schemes employing variational quantum eigensolvers (VQEs) that have attracted significant interest in recent years. In this paper, we present a method that employs parametric Gaussian process regression (GPR) within an active learning framework to mitigate noise in quantum computations, focusing on VQEs. Our approach, grounded in probabilistic machine learning, exploits a custom prior based on the VQE ansatz to capture the underlying correlations between VQE outputs for different variational parameters, thereby enhancing both accuracy and efficiency. We demonstrate the effectiveness of our method on a two-site Anderson impurity model and a eight-site Heisenberg model, using the IBM open-source quantum computing framework, Qiskit, showcasing substantial improvements in the accuracy of VQE outputs while reducing the number of direct QPU energy evaluations. This paper contributes to the ongoing efforts in quantum-error mitigation and optimization, bringing us a step closer to realizing the potential of quantum computing in quantum matter simulations. Published by the American Physical Society 2024

97 MATHEMATICS AND COMPUTING↗

Evidence of surface paramagnetism in niobium and consequences for the superconducting cavity surface impedance.

The presence of magnetic impurities in native niobium oxides have been confirmed by Point contact spectroscopy (PCT), SQUID magnetometry and Electron paramagnetic resonance (EPR). All niobium (Nb) samples displayed a small impurity contribution to the magnetic susceptibility at low temperatures which exhibited Curie-Weiss behavior, indicative of weakly coupled localized paramagnetic moments. By examining Nb samples with widely varying surface-to-volume ratios (rods, foils, wires, powders) it was found that the impurity contribution is correlated with surface area. Tunneling measurements which use the native oxide layers as barriers exhibit a zero-bias conductance peak which splits in a magnetic field >; 4T, consistent with the Appelbaum-Anderson model for spin flip tunneling. Viewed together the experiments strongly suggest that the native oxides of Nb are intrinsically defective, and consistently exhibit localized paramagnetic moments caused by oxygen vacancies in Nb{sub 2}O{sub 5}. The computation of the surface impedance (R{sub s}) in presence of magnetic impurities in the Shiba approximation reveals the saturation at low temperature of R{sub s}, suggesting that magnetic impurities are responsible for the so-called residual resistance. These properties may have an impact on Nb based superconducting devices and shine a new light on the origin of the paramagnetic Meissner effect (PME).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerated Deterministic Phonon Transport With Consistent Material Temperature and Intensities

Abstract We present a method for deterministically solving the frequency and temperature dependent phonon radiative transport (PRT) equation in the single-mode relaxation time (SMRT) approximation in the self-adjoint angular flux (SAAF) form. To handle the nonlinear coupling between the phonon intensities and the material temperature, we apply a linearization approach that is similar to one in thermal radiative transport. This procedure leads to the PRT equation with pseudo-scattering. The method presented includes acceleration of both the inner pseudo-scattering source iterations and outer temperature iteration with a gray diffusion synthetic acceleration (DSA) and Anderson acceleration, respectively. We use the finite-element method to discretize the PRT equation in space and the method of discrete ordinates (SN) for angular discretization. The proposed method is verified by a gray method of manufactured solutions problem and demonstrated on a problem using temperature and direction dependent multigroup data from lithium aluminate (LiAlO2). The iterative performance of the acceleration method in each test is then compared to the unaccelerated method.

Engineering↗

Variation in band offsets at ZnO/Sn:In2O3 (ITO) heterojunctions measured by x-ray photoelectron spectroscopy

Rational design and optimization of efficient photovoltaics requires fundamental knowledge of both the materials properties of the individual components and the conduction and valence band alignments at the materials interfaces. Efficient collection of electrons photogenerated in the absorber material requires a small or zero conduction band offset at both the absorber/n-type semiconductor and the n-type semiconductor/electrode interfaces. Negative conduction band offsets result in an energy barrier to electron injection, while large positive conduction band offsets (a “cliff” arrangement) result in too much energy lost during injection. However, it is difficult to predict heterojunction band offsets from bulk materials properties. Experimental band alignments of semiconductor heterojunctions rarely conform to the Anderson model,1 which assumes the band alignments are determined solely by differences in the electron affinity of the two semiconductors. Chemical bonds at the heterojunction interface give rise to an interfacial dipole which influences the interfacial band alignment. Thus, the complex interplay between electron affinity differences, Fermi level matching, interface-induced gap states, and band bending determine heterojunction band alignments.2-5 Band alignments can also be modified by doping, point defects, or control of non-stoichiometry at the interface; since these parameters can be affected by processing conditions, they offer a mechanism to modify the band alignments of a given heterojunction system.

36 MATERIALS SCIENCE↗

Terahertz lightwave control of non-equilibrium phases and collective modes in multi-band superconductors

A gauge-invariant density matrix approach is presented to describe the non-equilibrium dynamics of multiband superconductors after photo-excitation. The derived gauge-invariant Bloch equations extend the Anderson pseudo-spin precession model by fully incorporating the center-of-mass motion of Cooper pairs. We also describe lightwave propagation effects inside a superconducting film by including the self-consistent interaction of the photo-excited superconducting system with the propagating electromagnetic field inside the superconductor using Maxwell's equations.

Mootz, Martin↗

Initial beam size study for passive scatter proton therapy. I. Monte Carlo verification

The purpose of this work was to provide an initial validation of a Monte Carlo (MC) model of the passive scattering treatment nozzle at University of Texas M. D. Anderson Cancer Center Proton Therapy Center. The MC model included a detailed definition of each beam-modifying element in the nozzle, and calculations accounted for interactions of the beam with the rotating modulator wheel used to create the spread out Bragg peak. In this work we show comparisons of calculated dose and fluence profiles with measured data from the nozzle for the 250 and 180 MeV beam energies used for patient treatments. Agreement to within 1.5 mm of measured data was observed for all MC calculations. The high level of agreement between the measurements and the MC model for the two beam energies studied provides validation for use of the model in a study of the dosimetric effects of the proton beam size and shape at the nozzle entrance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams

Purpose: Optically stimulated luminescent detectors (OSLDs) have a number of advantages in radiation dosimetry making them excellent dosimeters for quality assurance and patient dose verification. Although the dosimeters have been investigated in several modalities, relatively little work has been done in examining the dosimeters for use in clinical proton beams. This study examined a number of characteristics of the response of the dosimeters in the spread-out Bragg peak (SOBP) region of clinical proton beams. Methods: Optically stimulated luminescence (OSL) dosimeters from Landauer, Inc., specifically the nanoDot dosimeter, were investigated. These dosimeters were placed in a special phantom with a recess to fit the dosimeters without an air gap. Beams with nominal energies of 160, 200, and 250 MeV were used in the passively-scattered proton beam at the MD Anderson Cancer Center Proton Therapy Center. Dosimetric properties including linearity, field size dependence, energy dependence, residual signal as a function of cumulative dose, and postirradiation fading were investigated by taking measurements at the center of SOBPs. Results: The dosimeters showed 1% supralinearity at 200 cGy and 5% supralinearity at 1000 cGy. No noticeable field size dependence of the detector was found for field sizes from 2 x 2 cm{sup 2} to 18 x 18 cm{sup 2}. Residual signal as a function of cumulative dose showed a small increase for measurements up to 1000 cGy. Readout signal depletion of the dosimeters after consecutive readings showed a slightly larger depletion in protons for doses up to 500 cGy but not by a clinically significant amount. Within the center of various SOBP widths and proton energies the variation in response was less than 2%. An average beam quality factor of 1.089 with experimental standard deviation of 0.007 was determined and applied to the data such that the results were within 1.2% of ion chamber data. Conclusions: The nanoDot OSL dosimeter characteristics were studied in the SOBP region of clinical proton beams. To achieve accurate dosimetric readings, corrections to the dosimeter response were applied. Corrections tended to be minimal or broadly consistent. The nanoDot OSLD was found to be an acceptable dosimeter for measurement in the SOBP region for a range of clinical proton beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine

Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, −0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for distance-to-agreement.Conclusions: The authors found HPlusQA to be reasonably effective (79%± 10%) in determining when the comparison between measured dose planes and the dose planes calculated by the Eclipse treatment planning system had exceeded the acceptable tolerance levels. When used as described in this study, HPlusQA can reduce the need for patient specific quality assurance measurements by 64%. The authors believe that the use of HPlusQA as a dose calculation second check can increase the efficiency and effectiveness of the QA process.

61 RADIATION PROTECTION AND DOSIMETRY↗