Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D INTEGRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Overview of Heatshield for Extreme Entry Environment Technology (HEEET) Engineering Test Unit (ETU) Manufacturing and Integration

The Heatshield for Extreme Entry Environment Technology (HEEET) projects objective is to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations such as Venus and Saturn. A key aspect of the project has been the development of the manufacturing and integration processes/procedures necessary to build a heat shield utilizing the HEEET 3D-woven material. This has culminated in the building of a 1meter diameter Engineering Test Unit (ETU) representative of what would be used for a Saturn probe. This presentation will provide an overview of the manufacturing and integration processes utilized to build the ETU, with a focus on the seam design. The seam design represented the most challenging aspect of the HEEET development, given the aerothermal and structural requirements it needs to meet.

Thermal Protection System↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Efficient lattice QCD computation of radiative-leptonic-decay form factors at multiple positive and negative photon virtualities

In previous work [D. Giusti, Methods for high-precision determinations of radiative-leptonic decay form factors using lattice QCD, Phys. Rev. D 107, 074507 (2023)], we showed that form factors for radiative leptonic decays of pseudoscalar mesons can be determined efficiently and with high precision from lattice QCD using the “three-dimensional (3D) method,” in which three-point functions are computed for all values of the current insertion time and the time integral is performed at the data-analysis stage. Here, we demonstrate another benefit of the 3D method: the form factors can be extracted for any number of nonzero photon virtualities from the same three-point functions at no extra cost. We present results for the $D_s → ℓνγ*$ vector form factor as a function of photon energy and photon virtuality, for both positive and negative virtuality, for a single ensemble with 340 MeV pion mass and 0.11 fm lattice spacing. In our analysis, we separately consider the two different time orderings and the different quark flavors in the electromagnetic current. We discuss in detail the behavior of the unwanted exponentials contributing to the three-point functions, as well as the choice of fit models and fit ranges used to remove them for various values of the virtuality. While positive photon virtuality is relevant for decays to multiple charged leptons, negative photon virtuality suppresses soft contributions and is of interest in QCD-factorization studies of the form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel methodology for 3D deformable dosimetry

Purpose: Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. Methods: A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. Results: Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all three dimensions occurring as a result of the change in shape of the target between irradiations, even for a relatively simple deformation. Discrepancies of up to 30% of the maximum dose were evident from dose difference maps for three orthogonal planes taken through the isocenter of a stereotactic field. Conclusions: This paper describes the first use of a tissue-equivalent, 3D dose-integrating deformable phantom that yields integrated or redistributed dosimetric information. The proposed methodology readily yields three-dimensional (3D) dosimetric data from radiation delivery to the DEFGEL phantom in deformed and undeformed states. The impacts of deformation on dose distributions were readily seen in the isodose contours and line profiles from the three arrangements. It is demonstrated that the system is potentially capable of reproducibly emulating the physical deformation of an organ, and therefore can be used to evaluate absorbed doses to deformable targets and organs at risk in three dimensions and to validate deformation algorithms applied to dose distributions.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-C-17A-12: Integrated CBCT and Optical Tomography System On-Board a Small Animal Radiation Research Platform (SARRP)

Purpose: We present a newly developed on-board optical tomography system for SARRP. Innovative features include the compact design and fast acquisition optical method to perform 3D soft tissue radiation guidance. Because of the on-board feature and the combination of the CBCT, diffusive optical tomography (DOT), bioluminescence and fluorescence tomography (BLT and FT), this integrated system is expected to provide more accurate soft tissue guidance than an off-line system as well as highly sensitive functional imaging in preclinical research. Methods: Images are acquired in the order of CBCT, DOT and then BLT/FT, where the SARRP CBCT and DOT are used to provide the anatomical and optical properties information to enhance the subsequent BLT/FT optical reconstruction. The SARRP stage is redesigned to include 9 imbedded optical fibers in contact with the animal's skin. These fibers, connected to a white light lamp or laser, serve as the light sources for the DOT or FT, respectively. A CCD camera with f/1.4 lens and multi-spectral filter set is used as the optical detector and is mounted on a portable cart ready to dock into the SARRP. No radiation is delivered during optical image acquisition. A 3-way mirror system capable of 180 degree rotation around the animal reflects the optical signal to the camera at multiple projection angles. A special black-painted dome covers the stage and provides the light shielding. Results: Spontaneous metastatic bioluminescent liver and lung tumor models will be used to validate the 3D BLT reconstruction. To demonstrate the capability of our FT system, GastroSense750 fluorescence agent will be used to imaging the mouse stomach and intestinal region in 3D. Conclusion: We expect that this integrated CBCT and optical tomography on-board a SARRP will present new research opportunities for pre-clinical radiation research. Supported by NCI RO1-CA 158100.

60 APPLIED LIFE SCIENCES↗

Three-dimensional electron temperature measurement of inertial confinement fusion hotspots using x-ray emission tomography

Here we present a novel approach to reconstruct three-dimensional (3D) electron temperature distributions of inertially confined fusion plasma hotspots at the National Ignition Facility. Using very limited number of two-dimensional (2D) x-ray imaging lines of sight, we perform 3D reconstructions of x-ray emission distributions from different x-ray energy channels ranging from 20 to 30 keV. 2D time-integrated x-ray images are processed using the algebraic reconstruction technique to reconstruct a 3D hotspot x-ray emission distribution that is self-consistent with the input images. 3D electron temperatures are computed using the energy channel ratios. We demonstrate the high accuracy and applicability of this method with different complex hotspot geometries in both synthetic and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and electrical characterization of two-dimensional layered MoS{sub 2}/SiC heterojunctions

The growth and electrical characterization of the heterojunction formed between two-dimensional (2D) layered p-molybdenum disulfide (MoS{sub 2}) and nitrogen-doped 4H silicon carbide (SiC) are reported. The integration of 2D semiconductors with the conventional three-dimensional (3D) substrates could enable semiconductor heterostructures with unprecedented properties. In this work, direct growth of p-type MoS{sub 2} films on SiC was demonstrated using chemical vapor deposition, and the MoS{sub 2} films were found to be high quality based on x-ray diffraction and Raman spectra. The resulting heterojunction was found to display rectification and current-voltage characteristics consistent with a diode for which forward conduction in the low-bias region is dominated by multi-step recombination tunneling. Capacitance-voltage measurements were used to determine the built-in voltage for the p-MoS{sub 2}/n-SiC heterojunction diode, and we propose an energy band line up for the heterostructure based on these observations. The demonstration of heterogeneous material integration between MoS{sub 2} and SiC enables a promising new class of 2D/3D heterostructures.

36 MATERIALS SCIENCE↗

Computing Radiative Transfer in a 3D Medium

A package of software computes the time-dependent propagation of a narrow laser beam in an arbitrary three- dimensional (3D) medium with absorption and scattering, using the transient-discrete-ordinates method and a direct integration method. Unlike prior software that utilizes a Monte Carlo method, this software enables simulation at very small signal-to-noise ratios. The ability to simulate propagation of a narrow laser beam in a 3D medium is an improvement over other discrete-ordinate software. Unlike other direct-integration software, this software is not limited to simulation of propagation of thermal radiation with broad angular spread in three dimensions or of a laser pulse with narrow angular spread in two dimensions. Uses for this software include (1) computing scattering of a pulsed laser beam on a material having given elastic scattering and absorption profiles, and (2) evaluating concepts for laser-based instruments for sensing oceanic turbulence and related measurements of oceanic mixed-layer depths. With suitable augmentation, this software could be used to compute radiative transfer in ultrasound imaging in biological tissues, radiative transfer in the upper Earth crust for oil exploration, and propagation of laser pulses in telecommunication applications.

Von Allmen, Paul↗

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated three-dimensional photonic nanostructures for achieving near-unity solar absorption and superhydrophobicity

In this paper, we proposed and realized 3D photonic nanostructures consisting of ultra-thin graded index antireflective coatings (ARCs) and woodpile photonic crystals. The use of the integrated ARC and photonic crystal structure can achieve broadband, broad-angle near unity solar absorption. The amorphous silicon based photonic nanostructure experimentally shows an average absorption of ∼95% for λ = 400–620 nm over a wide angular acceptance of θ = 0°–60°. Theoretical studies show that a Gallium Arsenide (GaAs) based structure can achieve an average absorption of >95% for λ = 400–870 nm. Furthermore, the use of the slanted SiO{sub 2} nanorod ARC surface layer by glancing angle deposition exhibits Cassie-Baxter state wetting, and superhydrophobic surface is obtained with highest water contact angle θ{sub CB} ∼ 153°. These properties are fundamentally important for achieving maximum solar absorption and surface self-cleaning in thin film solar cell applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atmospheric and soil-gas monitoring for surface leakage at the San Juan Basin CO{sub 2} pilot test site at Pump Canyon New Mexico, using perfluorocarbon tracers, CO{sub 2} soil-gas flux and soil-gas hydrocarbons

Near-surface monitoring and subsurface characterization activities were undertaken in collaboration with the Southwest Regional Carbon Sequestration Partnership on their San Juan Basin coal-bed methane pilot test site near Navajo City, New Mexico. Nearly 18,407 short tons (1.670 × 107 kg) of CO{sub 2} were injected into 3 seams of the Fruitland coal between July 2008 and April 2009. Between September 18 and October 30, 2008, two additions of approximately 20 L each of perfluorocarbon (PFC) tracers were mixed with the CO{sub 2} at the injection wellhead. PFC tracers in soil-gas and in the atmosphere were monitored over a period of 2 years using a rectangular array of permanent installations. Additional monitors were placed near existing well bores and at other locations of potential leakage identified during the pre-injection site survey. Monitoring was conducted using sorbent containing tubes to collect any released PFC tracer from soil-gas or the atmosphere. Near-surface monitoring activities also included CO{sub 2} surface flux and carbon isotopes, soil-gas hydrocarbon levels, and electrical conductivity in the soil. The value of the PFC tracers was demonstrated when a significant leakage event was detected near an offset production well. Subsurface characterization activities, including 3D seismic interpretation and attribute analysis, were conducted to evaluate reservoir integrity and the potential that leakage of injected CO{sub 2} might occur. Leakage from the injection reservoir was not detected. PFC tracers made breakthroughs at 2 of 3 offset wells which were not otherwise directly observable in produced gases containing 20–30% CO{sub 2}. These results have aided reservoir geophysical and simulation investigations to track the underground movement of CO{sub 2}. 3D seismic analysis provided a possible interpretation for the order of appearance of tracers at production wells.

54 ENVIRONMENTAL SCIENCES↗

Numerical Analysis of Stress Intensity Factors in Three-Dimensional Functionally Graded Materials

In this paper, a finite element method based on nonhomogeneous elements is used to study crack problems in three-dimensional (3D) functionally graded materials (FGMs). Since the actual material properties at each integral point are employed in the integration during formation of the element stiffness matrix, each element can have nonhomogeneous material properties. By this method, the number of elements is reduced and the meshing effort for the structure is simplified. Therefore, the modeling process for numerical simulation of fracture behavior in 3D FGMs is greatly simplified. The crack front characteristics of Mode-I edge penetrable crack in 3D FGM specimens are studied under uniform tension loading. The influence of material nonhomogeneity constant and geometric parameters on the stress intensity factors (SIFs) of the 3D FGM specimens are investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strain mapping of three-dimensionally structured two-dimensional materials

Strain plays a crucial role in tuning materials’ properties, influencing their optical, electrical, and chemical performances. In two-dimensional (2D) materials, applied stress often induces out-of-plane deformation, resulting in a more intricate three-dimensional (3D) topography, where mapping the strain remains a challenge due to the limitations of conventional characterization techniques. In this work, we introduce BRIGHT (Bragg-Rod Informed, Gradient-based Height-mapping Technique), an integrated method for reconstructing both the topography and planar strain profile of 3D-structured 2D materials using nanobeam four-dimensional scanning transmission electron microscopy (4D-STEM). We apply BRIGHT to a MoS2-MoSe2 transition metal dichalcogenide (TMD) lateral heterojunctions exhibiting built-in strain and out-of-plane ripples and show that varying heterojunction widths lead to distinct surface morphologies and corresponding changes in the planar strain distribution. These results establish a foundation for more effective strain engineering in 2D materials by accounting for out-of-plane structural features, thereby enabling more precise control of strain-dependent properties.

Mireles, Adan [Rice Univ., Houston, TX (United Sta↗

Large-Format, Fully-Depleted, Back-Illuminated CMOS Imaging Technology

A Voxtel-led team has developed a new class of large-area, high-performance, backside-illuminated CMOS imaging sensor for low-light-level surveillance applications, specifically designed for both low-noise and high near-infrared (NIR) response. The imager integrates two technologies: 1) large-area backside-illuminated (BSI) imaging; and 2) high-density 3D via-less electrical interconnection and wafer bonding. In this program, Voxtel, in collaboration with Jazz Semiconductor, Sharp Labs and Ziptronix Inc., developed and fabricated a wafer-scale imaging platform. We integrated the design rules necessary for large-area photocomposition using a sub-field stitched reticle at Jazz, and wafer-scale 3D stacked electrical connect using the Ziptronix process. The Jazz CA25QFES process was shown to be ideal for use in the Ziptronix process because of its compatibility with the last via back end of line (BEOL) process used to create tungsten vias up to the wafer surface. To accomplish program goals, Voxtel integrated and fabricated a stitched CMOS ROIC design, and bonded the ROIC to an array of thick, high-resistivity, fully depleted pinned silicon photodiodes, fabricated in a silicon-on-insulator (SOI) wafer. By fabricating the detector and ROIC separately, the silicon used to fabricate the circuits from the ROIC and the fully depleted, high-resistivity silicon detector array are optimized for their respective tasks, improving their performance, increasing yield, and reducing cost.

14 SOLAR ENERGY↗

Effects of 3d electron configurations on helium bubble formation and void swelling in concentrated solid-solution alloys

Currently, elemental specific chemical complexity is known to play a vital role in microstructure development in single-phase concentrated solid-solution alloys (SP-CSAs), including both He bubble formation and irradiation-induced void swelling. While cavity formation and evolution under ion irradiation at elevated temperature are complex nonequilibrium processes, chemical effects are revealed at the level of electrons and atoms herein in a simplified picture, using Ni and a special set of Ni-based SP-CSAs composed of 3d transition metals as model alloys. Based on Ni and the model alloys with minimized variables (e.g., atomic mass, size, and lattice structure), we report on the effects of chemically-biased energy dissipation, defect energetics, sluggish diffusion, and atomic transport on cavity formation and evolution under both self-ion Ni irradiation and He implantation. The observed difference in microstructure evolution is attributed to the effects of d electron interactions in their integrated ability to dissipate radiation energy. The exhibited impact of alloying 3d transition metals with larger differences in the outermost electron counts suggests a simple design strategy for tuning defect properties to improve radiation tolerance in structural alloys.

36 MATERIALS SCIENCE↗

High speed vibration compensation using magnetic fiducials via NIMBLE

Additive manufacturing (AM) technology, specifically 3D printing, holds great promise for in-orbit manufacturing. In-space printing can significantly reduce the mass, cost, and risk of long-term space exploration by enabling replacement parts to be made as needed and reducing dependence on Earth. However, printing in a zero-gravity environment poses challenges due to the absence of a rigid ground for the print platform, which can result in vibrational and rotational forces that may impact printing integrity. Here, to address this issue, this paper proposes a novel linear magnetic position tracking algorithm, named Navigation Integrating Magnets By Linear Estimation (NIMBLE), for dynamic vibration compensation during 3D printing of truss structures in space. Compared to the most commonly used nonlinear optimization method, the NIMBLE algorithm is more than two orders of magnitude faster. With only a single 3-axis magnet sensor and a small NdFeB magnet, the NIMBLE algorithm provides a simple and easily implemented tracking solution for in-orbit 3D printing.

3D printing in space↗

Physics augmented machine learning discovery of composition-dependent constitutive laws for 3D printed digital materials

Multi-material 3D printing, particularly through polymer jetting, enables the fabrication of digital materials by mixing distinct photopolymers at the micron scale within a single build to create a composite with tunable mechanical properties. Here, this work presents an integrated experimental and computational investigation into the composition-dependent mechanical behavior of 3D printed digital materials. We experimentally characterize five formulations, combining soft and rigid UV-cured polymers under uniaxial tension and torsion across three strain and twist rates. The results reveal nonlinear and rate-dependent responses that strongly depend on composition. To model this behavior, we develop a physics-augmented neural network (PANN) that combines a partially input convex neural network (pICNN) for learning the composition-dependent hyperelastic strain energy function with a quasi-linear viscoelastic (QLV) formulation for time-dependent response. The pICNN ensures convexity with respect to strain invariants while allowing non-convex dependence on composition. To enhance interpretability, we apply $L_0$ sparsification. For the time-dependent response, we introduce a multilayer perceptron (MLP) to predict viscoelastic relaxation parameters from composition. The proposed model accurately captures the nonlinear, rate-dependent behavior of 3D printed digital materials in both uniaxial tension and torsion, achieving high predictive accuracy for interpolated material compositions. This approach provides a scalable framework for automated, composition-aware constitutive model discovery for multi-material 3D printing.

Constitutive modeling↗

Raptor

Raptor is an efficient Python-based tool for predicting the formation and morphology of stochastic lack of fusion defects in metal AM processes. A major obstacle for the qualification and certification of additively manufactured parts in critical applications continues to be performance variability caused in part by porosity-related defects. High-fidelity process models that could predict these defect features are currently too computationally expensive for component-level analysis. To address this, Raptor employs a high-performance geometric method to model the dynamic melt pool rather than relying on computationally intensive thermal fluid dynamics. This allows Raptor to rapidly identify regions of unmelted material that correspond to lack of fusion pores. The efficiency of this approach significantly reduces the time and resources needed for generating 3D defect predictions, which enables users to conduct large-scale parameter studies and evaluate how process variations affect part quality. The framework offers operational flexibility; users can execute simulations through a simple command line interface or integrate core functions as a library within larger computational workflows. Simulation outputs include 3D porosity maps for visualization and tools for quantitative morphological analysis. These results are suitable for direct comparison with experimental characterization data from methods such as X-ray computed tomography and can be used for statistical process optimization.

Subraveti, Vamsi [Vanderbilt Univ., Nashville, TN ↗