Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Deliquescence of eutectic LiCl-KCl diluted with NaCl for interim waste salt storage

Molten eutectic LiCl-KCl salt is a widely used electrolyte for electrorefining uranium from spent nuclear fuel. Due to the hygroscopic nature of this salt, careful handling and storage of solidified waste electrorefiner (ER) salt is required to avoid deliquescence and corrosion of container materials. This study investigated a potential processing path for reducing the deliquescence through dilution with NaCl. The hydration behavior of LiCl-KCl salts diluted with NaCl was evaluated in terms of mass gain due to mass of water absorption, visual evidence of deliquescence, and visual evidence of corrosion to stainless steel containers in a humid air environment. Pure eutectic LiCl-KCl exhibited a 50 mass% increase due to water absorption and showed signs of deliquescence after 24 hours. 89 mass% NaCl was required in order to prevent deliquescence. Dilution with 89% NaCl was also found to protect corrosion to stainless steel crucibles. Corrosion, thus, appears to require deliquescence. While NaCl dilution greatly decreases steady state hydration and eliminated deliquescence, storage volume is increased ~10x.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing

Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.

Wang, Haoqing↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

DEVELOPMENT AND TESTING OF FAULT-DIAGNOSIS ALGORITHMS FOR REACTOR PLANT SYSTEMS

Argonne National Laboratory is further developing fault diagnosis algorithms for use by the operator of a nuclear plant to aid in improved monitoring of overall plant condition and performance. The objective is better management of plant upsets through more timely, informed decisions on control actions with the ultimate goal of improved plant safety, production, and cost management. Integration of these algorithms with visual aids for operators is taking place through a collaboration under the concept of an operator advisory system. This is a software entity whose purpose is to manage and distill the enormous amount of information an operator must process to understand the plant state, particularly in off-normal situations, and how the state trajectory will unfold in time. The fault diagnosis algorithms were exhaustively tested using computer simulations of twenty different faults introduced into the chemical and volume control system (CVCS) of a pressurized water reactor (PWR). The algorithms are unique in that each new application to a facility requires providing only the piping and instrumentation diagram (PID) and no other plant-specific information; a subject-matter expert is not needed to install and maintain each instance of an application. The testing approach followed accepted procedures for verifying and validating software. It was shown that the code satisfies its functional requirement which is to accept sensor information, identify process variable trends based on this sensor information, and then to return an accurate diagnosis based on chains of rules related to these trends. The validation and verification exercise made use of GPASS, a one-dimensional systems code, for simulating CVCS operation. Plant components were failed and the code generated the resulting plant response. Parametric studies with respect to the severity of the fault, the richness of the plant sensor set, and the accuracy of sensors were performed as part of the validation exercise. The background and overview of the software will be presented to give an overview of the approach. Following, the verification and validation effort using the GPASS code for simulation of plant transients including a sensitivity study on important parameters will be presented

Fault Diagnosis Algorithm↗

Volcano infrasound: progress and future directions

Over the past two decades (2000–2020), volcano infrasound (acoustic waves with frequencies less than 20 Hz propagating in the atmosphere) has evolved from an area of academic research to a useful monitoring tool. As a result, infrasound is routinely used by volcano observatories around the world to detect, locate, and characterize volcanic activity. It is particularly useful in confirming subaerial activity and monitoring remote eruptions, and it has shown promise in forecasting paroxysmal activity at open-vent systems. Fundamental research on volcano infrasound is providing substantial new insights on eruption dynamics and volcanic processes and will continue to do so over the next decade. The increased availability of infrasound sensors will expand observations of varied eruption styles, and the associated increase in data volume will make machine learning workflows more feasible. More sophisticated modeling will be applied to examine infrasound source and propagation effects from local to global distances, leading to improved infrasound-derived estimates of eruption properties. Future work will use infrasound to detect, locate, and characterize moving flows, such as pyroclastic density currents, lahars, rockfalls, lava flows, and avalanches. Infrasound observations will be further integrated with other data streams, such as seismic, ground- and satellite-based thermal and visual imagery, geodetic, lightning, and gas data. The volcano infrasound community should continue efforts to make data and codes accessible and to improve diversity, equity, and inclusion in the field. In summary, the next decade of volcano infrasound research will continue to advance our understanding of complex volcano processes through increased data availability, sensor technologies, enhanced modeling capabilities, and novel data analysis methods that will improve hazard detection and mitigation.

58 GEOSCIENCES↗

X-ray microtomography of field-induced macro-structures in a ferrofluid.

X-ray microtomography is used to visualize, in-situ, the three-dimensional nature of the magnetic field induced macro-structures (>1 ?m) inside a bulk (not, vert, similar1 mm diameter) magnetite-particle-mineral oil ferrofluid sample. Columnar structures of not, vert, similar10 ?m diameter were seen under a 0.35 kG applied magnetic field, while labyrinth type structures not, vert, similar4 ?m in width were seen at 0.55 kG. The structures have height/width aspect ratios >100. The results show that the magnetite volume fraction is not constant within the structures and on average is considerably less than a random sphere packing model.

36 MATERIALS SCIENCE↗

MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41 Degree-Sign {+-} 0.45 Degree-Sign and a translation error of 1.67 {+-} 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional characterization of hardened paste of hydrated tricalcium silicate by serial block-face scanning electron microscopy

With the application of a three-dimensional (3D) characterization technique, serial block-face scanning electron microscopy (SBFSEM), the 3D microstructure of a hydrated cement monomineral, tricalcium silicate (C 3 S), was measured with nanoscale resolution. The 3D morphologies of anhydrous particles, hydrated products, and capillary pores were visualized. Closed and open pores were discovered inside an anhydrous particle. The size and distribution of both the anhydrous C 3 S particles and their capillary pores were analyzed quantitatively and the porosity was determined to be 9%. The distribution of pores was found to be in a good agreement with the inner and outer product model of Hu et. al., with an inner shell distance of 860 nm. Here, considering the spatial resolution of the instrument and the volume of sample measured, most pores in this experiment could be characterized as capillary pores.

3D microstructure↗

Visualizing subcellular rearrangements in intact β cells using soft x-ray tomography

Characterizing relationships between cell structures and functions requires mesoscale mapping of intact cells showing subcellular rearrangements following stimulation; however, current approaches are limited in this regard. Here, we report a unique application of soft x-ray tomography to generate three-dimensional reconstructions of whole pancreatic β cells at different time points following glucose-stimulated insulin secretion. Reconstructions following stimulation showed distinct insulin vesicle distribution patterns reflective of altered vesicle pool sizes as they travel through the secretory pathway. Our results show that glucose stimulation caused rapid changes in biochemical composition and/or density of insulin packing, increased mitochondrial volume, and closer proximity of insulin vesicles to mitochondria. Costimulation with exendin-4 (a glucagon-like peptide-1 receptor agonist) prolonged these effects and increased insulin packaging efficiency and vesicle maturation. This study provides unique perspectives on the coordinated structural reorganization and interactions of organelles that dictate cell responses.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of realistic PET simulations incorporating tumor patient's specificity using anthropomorphic models: Creation of an oncology database

Purpose: The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging system's performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties.Methods: PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient-specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distribution corresponding to the clinical image following PVC. The three different types of simulated data in each case were reconstructed with two iterations and filtered with a 3D Gaussian postfilter, in order to simulate the intratumor heterogeneous uptake. Heterogeneity in all generated images was quantified using textural feature derived parameters in 3D according to the ground truth of the simulation, and compared to clinical measurements. Finally, profiles were plotted in central slices of the tumors, across lines with heterogeneous activity distribution for visual assessment.Results: The accuracy of the simulated database was assessed against the original clinical images. The PVC simulated images matched the clinical ones best. Local, regional, and global features extracted from the PVC simulated images were closest to the clinical measurements, with the exception of the size zone variability and the mean intensity values, where heterogeneous tumors showed better reproducibility. The profiles on PVC simulated tumors after postfiltering seemed to represent the more realistic heterogeneous regions with respect to the clinical reference.Conclusions: In this study, the authors investigated the input activity map heterogeneity in the GATE simulations of tumors with heterogeneous activity distribution. The most realistic heterogeneous tumors were obtained by inserting PVC activity distributions from the clinical image into the activity map of the simulation. Partial volume effect (PVE) can play a crucial role in the quantification of heterogeneity within tumors and have an important impact on applications such as patient follow-up during treatment and assessment of tumor response to therapy. The development of such a database incorporating patient anatomical and functional variability can be used to evaluate new image processing or analysis algorithms, while providing control of the ground truth, which is not available when dealing with clinical datasets. The database includes all images used and generated in this study, as well as the sinograms and the attenuation phantoms for further investigation. It is freely available to the interested reader of the journal at http://www.med.upatras.gr/oncobase/.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4D structural changes and pore network model of biomass during pyrolysis

Biochar is an engineered carbon-rich substance used for soil improvement, environmental management, and other diverse applications. To date, the understanding of how biomass affects biochar microstructure has been limited due to the complexity of analysis involved in tracing the changes in the physical structure of biomass as it undergoes thermochemical conversion. In this study, we used synchrotron x-ray micro-tomography to visualize changes in the internal structure of biochar from diverse feedstock (miscanthus straw pellets, wheat straw pellets, oilseed rape straw pellets, and rice husk) during pyrolysis by collecting a sequence of 3D scans at 50 °C intervals during progressive heating from 50 °C to 800 °C. The results show a strong dependence of biochar porosity on feedstock as well as pyrolysis temperature, with observed porosity in the range of 7.41–60.56%. Our results show that the porosity, total surface area, pore volume, and equivalent diameter of the largest pore increases with increasing pyrolysis temperature up to about 550 °C. The most dramatic development of pore structure occurred in the temperature range of 350–450 °C. This understanding is pivotal for optimizing biochar’s properties for specific applications in soil improvement, environmental management, and beyond. By elucidating the nuanced variations in biochar’s physical characteristics across different production temperatures and feedstocks, this research advances the practical application of biochar, offering significant benefits in agricultural, environmental, and engineering contexts.

54 ENVIRONMENTAL SCIENCES↗

Measurement of needle and armature dynamics in a gasoline direct injector by high-speed neutron imaging

In modern spark ignition engines, precise delivery of fuel with gasoline direct injection has become increasingly important in the effort to meet ever stricter efficiency and emissions regulations. Use of multiple small close-coupled injections has become more common in attempt to precisely control fuel distribution in the cylinder, but these strategies are hindered by nonlinear injection effects due to operation in the ballistic region of the solenoid-operated valve and due to armature bounce at the end of injection. Understanding the internal dynamics of the injector is crucial to minimizing and controlling non-linearity and shot-to-shot variation, but the experimental techniques available to date are capable only of tracking the position of either the top of the needle (via laser sensors or by monitoring current and voltage in the solenoid coil) or the bottom of the needle (via transparent nozzles or high-speed x-ray imaging). Furthermore, a complete picture of the axial and radial motion of valve needle has until now remained elusive. In this work, we present high-speed ensemble neutron transmission imaging of an entire 8-hole gasoline direct injector operating at 200 bar, allowing for both visualization and quantification of the actuation dynamics including lift and wobble of the valve ball, oscillation and bending of the valve needle, lift, rocking, and bounce of the armature, compression of the springs, and radial swelling of the solenoid during energization. Because neutrons offer high penetration through the metal injector while also being sensitive to the 1 H nuclei in fuel molecules, it is also possible to simultaneously see the fluid dynamics of the injection process, including filling of the sac volume, emanation of the spray through the nozzle holes and into the downstream gas, and the formation and evolution of fuel films on the tip of the injector and the walls of the spray container.

33 ADVANCED PROPULSION SYSTEMS↗

Field‐Induced Ferroelectric Phase Evolution During Polarization “Wake‐Up” in Hf 0.5 Zr 0.5 O 2 Thin Film Capacitors

Abstract As an emerging nonvolatile memory technology, HfO 2 ‐based ferroelectrics exhibit excellent compatibility with silicon CMOS process flows; however, the reliability of polarization switching in these materials remains a major challenge. During repeated field programming and erase of the polarization state of initially pristine HfO 2 ‐based ferroelectric capacitors, the magnitude of the measured polarization increases, a phenomenon known as “wake‐up”. In this study, the authors attempt to understand what causes the wake‐up effect in Hf 0.5 Zr 0.5 O 2 (HZO) capacitors using nondestructive methods that probe statistically significant sample volumes. Synchrotron X‐ray diffraction reveals a concerted shift in HZO Bragg peak position as a function of polarization switching cycle number in films prepared under conditions such that they exhibit extremely large (≈3000%) wake‐up. In contrast, a control sample with insignificant wake‐up shows no such peak shift. Capacitance – voltage measurements show evolution in the capacitance loop with switching cycle number for the wake‐up sample and no change for the control sample. Piezoresponse force microscopy measurements are utilized to visualize the domain switching with wake‐up. The combination of these observations clearly demonstrates that wake‐up is caused by a field‐driven phase transformation of the tetragonal phase to the metastable ferroelectric orthorhombic phase during polarization switching of HZO capacitors.

36 MATERIALS SCIENCE↗

A primer on forest structure measurement with lidar for ecologists

Light detection and ranging (lidar) technology has fundamentally advanced the way we measure forest structure, facilitating new insights into ecological processes. Lidar for forest ecology applications is deployed on multiple types of platforms that operate from the ground, air, or space, and each has associated strengths and limitations. Ideally, the choice of what kind of lidar to use in a particular study should be guided by the ecological question of interest; however, practical considerations of cost, data availability, and processing tools can be equally important. This synthesis is a practical introduction to how different lidar platforms characterize forest structure (e.g., tree size/location, wood volume, branching structure, aboveground biomass, leaf properties), designed for a general audience of ecologists (not remote sensing scientists) seeking an accessible introduction to the use of lidar. We also provide examples of novel ecological insights from recent lidar research and describe current limitations and areas of expected improvement. Last, we include an appendix of data collected from terrestrial, mobile, unoccupied aerial system, airplane, and satellite lidar platforms within a common temperate forest area, with associated code to allow new lidar users to visualize and manipulate data in R.

Cushman, KC [ORNL] (ORCID:0000000234641151)↗

IDAES-PSE 2.6.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.6.0 Release Highlights Upcoming Changes IDAES will be switching to the new Pyomo solver interface in the next release. Whilst this will hopefully be a smooth transition for most users, there are a few important changes to be aware of. The new solver interface uses a different version of the IPOPT writer (“ipopt_v2”) and thus any custom configuration options you might have set for IPOPT will not carry over and will need to be reset. By default, the new Pyomo linear presolver will be activated with ipopt_v2. Whilst are working to identify any bugs in the presolver, it is possible that some edge cases will remain. IDAES will begin deploying a new set of scaling tools and APIs over the next few releases that make use of the new solver writers. The old scaling tools and APIs will remain for backward compatibility but will begin to be deprecated. New Models, Tools and Features New Intersphinx extension automatically linking Jupyter notebook examples to project documentation New end-to-end diagnostics example demonstrated on a real problem New complementarity formulation for VLE with cubic equations of state, backward compatibility for old formulation New solver interface with presolve (ipopt_v2) in support of upcoming changes to the initialization and APIs methods, with default set to ipopt to maintain backwards compatibility; this will deprecate once all examples have been updated New forecaster and parameterized bidder methods within grid integration library Updated surrogates API and examples to support Keras 3, with backwards compatibility for older formats such as TensorFlow SavedModel (TFSM) Updated costing base dictionary to include the 2023 cost year index value Updated ProcessBlock to include information on the constructing block class Updated Flowsheet Visualizer to allow visualize() method to return value and functions Bug Fixes Fixed bug in the Modular Property Framework that would cause errors when trying to use phase-based material balances with phase equilibria. Fixed bug in Modular Properties Framework that caused errors when initializing models with non-vapor-liquid phase equilibria. Fixed typos flagged by June update to crate-ci/typos and removed DMF-related exceptions Minor corrections of units of measurement handling in power plant waste/transport costing expressions, control volume material holdup expressions, and BTX property package parameters Fixed throwing >7500 numpy deprecation warnings by replacing scalar value assignment with element extraction and item iteration calls Testing and Robustness Migrated slow tests (>10s) to integration, impacting test coverage but also yielding a nearly 30% decrease in local test runtime Pinned pint to avoid issues with older supported Python versions Pinned codecov versions to avoid tokenless upload behavior with latest version Bumped extensions to version 3.4.2 to allow pointing to non-standard install location Deprecations and Removals Python 3.8 is no longer supported. The supported Python versions are 3.9 through 3.12 The Data Management Framework (DMF) is no longer supported. Importing idaes.core.dmf will cause a deprecation warning to be displayed until the next release The SOFC Keras surrogates have been removed. The current version of the SOFC surrogate model in the examples repository is a PySMO Kriging model.

AS↗

Analysis of flame surface density measurements in turbulent premixed combustion

In premixed turbulent combustion, reaction rates can be estimated from the flame surface density. This parameter, which measures the mean flame surface area available per unit volume, may be obtained from algebraic expressions or by solving a transport equation. In this study, detailed measurements were performed on a Bunsen-type burner fed with methane/air mixtures in order to determine the local flame surface density experimentally. This burner, located in a high-pressure combustion chamber, allows investigation of turbulent premixed flames under various flow, mixture, and pressure conditions. In the present work, equivalence ratio was varied from 0.6 to 0.8 and pressure from 0.1 to 0.9 MPa. Flame front visualizations by Mie scattering laser tomography are used to obtain experimental data on the instantaneous flame front dynamics. The exact equation given by Pope is used to obtain flame surface density maps for different flame conditions. Some assumptions are made in order to access three-dimensional information from our two-dimensional experiments. Two different methodologies are proposed and tested in term of global mass balance (what enters compared to what is burned). The detailed experimental flame surface data provided for the first time in this work should progressively allow improvement of turbulent premixed flame modeling approaches. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗