Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High-Voltage Charging-Induced Strain, Heterogeneity, and Micro-Cracks in Secondary Particles of a Nickel-Rich Layered Cathode Material

Nickel-rich layered materials LiNi 1-x-y Mn x Co y O 2 are promising candidates for high-energy-density lithium-ion battery cathodes. Unfortunately, they suffer from capacity fading upon cycling, especially with high-voltage charging. It is critical to have a mechanistic understanding of such fade. Synchrotron-based techniques (including scattering, spectroscopy, and microcopy) and finite element analysis are utilized to understand the LiNi 0.6 Mn 0.2 Co 0.2 O 2 material from structural, chemical, morphological, and mechanical points of view. The lattice structural changes are shown to be relatively reversible during cycling, even when 4.9 V charging is applied. However, local disorder and strain are induced by high-voltage charging. Nano-resolution 3D transmission X-ray microscopy data analyzed by machine learning methodology reveal that high-voltage charging induced significant oxidation state inhomogeneities in the cycled particles. Regions at the surface have a rock salt–type structure with lower oxidation state and build up the impedance, while regions with higher oxidization state are scattered in the bulk and are likely deactivated during cycling. In addition, the development of micro-cracks is highly dependent on the pristine state morphology and cycling conditions. Hollow particles seem to be more robust against stress-induced cracks than the solid ones, suggesting that morphology engineering can be effective in mitigating the crack problem in these materials.

25 ENERGY STORAGE↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Coal as Value-Added for Lithium Battery Anodes (Final Report)

Graphite is a basic material used for energy storage in lithium-ion (Li-ion) batteries. More than 70% of worldwide graphite production and nearly 50% of the annual graphite supply for the United States comes from China. Potential economic and national security concerns exist because Li-ion batteries are used not only for the fast-growing electrical vehicle market (15.6% compound annual growth rate [CAGR] from 2018 to 2028 in North America), but also for defense applications including unmanned aerial and ground vehicles. Development of an alternative formulation for Li-ion batteries is key. Building upon previous research confirming the ability of silicon alloys to improve the energy density of anodes, Semplastics developed a novel material based on our X-MAT® polymer-derived ceramic (PDC) technology. The X-MAT anode material is a composite of chemically tailored silicon oxycarbide (SiOC) and domestically sourced coal powder, designed to be a drop-in replacement for graphite within Li-ion battery anodes. Preliminary tests of this material showed more than twice the reversible capacity of graphite anodes (1,000 mAh/g vs. 372 mAh/g), with excellent stability and capacity retention, almost 100% coulombic efficiency, low voltage potential, and low thermal expansion. At full adoption in 2024, we expect the coal utilization to reach 27,300 tons. Through this project, Semplastics proposed to complete development and begin commercialization of this material. The objective was to determine the best formulation for technical performance and economic viability. At the end of the project, the X-MAT anode material is ready for implementation into existing battery manufacturing processes and can have a significant impact on the utilization of coal, with positive effects for the mining sector and the mitigation of carbon dioxide (CO 2 ) emissions.

01 COAL, LIGNITE, AND PEAT↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Unraveling the Cooperative Activity of Hydrophilicity, Conductivity, and Interfacial Active Sites in Alginate‐CNT‐Cuo Self‐Standing Electrodes with Benchmark‐Close Activity for Alkaline Water Splitting

Designing electrocatalysts that excel in hydrogen and oxygen electrochemistry is crucial for sustainable hydrogen generation through electrochemical water splitting. This study presents a novel tricomponent catalyst composed of an alginate hydrogel (AL) infused with single-walled carbon nanotubes (CNTs) and copper oxide (CuO) nanoparticles. The catalyst exhibits benchmark-close bifunctional activity toward hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) under alkaline conditions. The aerophobic nature of the AL-gel facilitates superior bubble release from the electrode, while the inclusion of CNTs mitigates charge transfer resistance. Moreover, heterojunctions of CuO and CNTs create unique interfacial active sites, culminating in high electrocatalytic water-splitting activity. The structural rigidity of the composite permits its use as self-standing electrodes (SSE) without using substrates or binders, enabling a direct evaluation of its activity. The composite electrode demonstrates exceptional electrocatalytic HER activity in an alkaline solution, with onset potentials of 93 mV and moderate OER activity with an onset of 155 mV. Furthermore, a water electrolysis cell featuring the bifunctional SSE exhibits an open circuit voltage of 1.85 V at 100 mA.cm −2 , and only 8% efficiency loss after 100 h marking this a significant stride in developing self-standing nonprecious electrocatalysts with impressive catalytic performance.

36 MATERIALS SCIENCE↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-based Inverters

Grid-forming inverters rely upon an internal reference to regulate the grid 's voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller's clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller's clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Performance enhancement of a polymer-electrolyte membrane H2O and CO2 co-electrolysis system for the production of syngas

Co-electrolysis of water and CO 2 to produce hydrogen and CO would provide an alternative pathway to making chemicals and fuels. The process could provide a way to use excess renewable electricity, or could be coupled to nuclear or carbon-based power generation. Opus 12 has overcome barriers to using a proton exchange membrane (PEM) reactor for this reaction by modifying the cathode catalyst layer to enhance simultaneous electrochemical H 2 production and CO 2 reduction. Current reactor performance metrics in terms of selectivity, current density, and applied voltage meet or exceed internal targets. However, the cell lifetime must be extended for a commercial product to be feasible. Through this H2@Scale project, we propose to work with the Weber Group at LBNL to diagnose performance decay mechanisms that currently limit the lifetime of the electrochemical syngas generator. LBNL is host to a number of advanced PEM diagnostic tools and lab scientists have unique experience in exploring performance and lifetime tradeoffs at the component to cell scales. Using the results of this study, the identified limiting mechanisms will be mitigated through improved cell and catalyst design.

10 SYNTHETIC FUELS↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-Based Inverters: Preprint

Grid-forming inverters rely upon an internal reference to regulate the grid’s voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller’s clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller’s clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Cathode Loading Effect on Sulfur Utilization in Lithium–Sulfur Battery

The Lithium-Sulfur (Li-S) battery is under intensive research in recent years due to its potential to provide higher energy density and lower cost than the current state-of-the-art lithium-ion battery technology. To meet cost target for transportation application, high sulfur loading up to 8 mAh cm -2 is predicted by modeling. In this work, we have investigated the sulfur loading effect on the galvanostatic charge/discharge cycling performance of Li-S cells with theoretical sulfur loading ranging from 0.5 mAh cm -2 to 7.5 mAh cm -2 . We found that the low sulfur utilization of electrodes with sulfur loading of > 3.0 mAh cm-2 is due to their inability to deliver capacities at the 2.1V voltage plateau, which corresponds to the conversion of soluble Li 2 S 4 to insoluble Li 2 S 2 /Li 2 S. This electrochemical conversion process recovers to deliver the expected sulfur utilization after several activation cycles for electrodes with sulfur loading up to 4.5 mAh cm -2 . For electrodes with 7.0 mAh cm -2 loading, no sulfur utilization recovery was observed for 100 cycles. The root cause of this phenomenon is elucidated by SEM/EDS and EIS investigation. Carbon interlayer cell design and low rate discharge activation are demonstrated to be effective mitigation methods.

25 ENERGY STORAGE↗

Software Development for Data Visualization and Analysis of PN-Diodes & MOSFET Devices

The U.S. Department of Energy has a broad mission to ensure the nation’s security by addressing ongoing environmental challenges, developing novel energy production technologies, and mitigating nuclear security concerns. These efforts benefit from developing more effective semiconductor materials and devices. The research discussed in this report aims to further the development of these new electronics by improving implementations of vertical device structures, which offer theoretically better performance compared to lateral structures. Specifically, it reviews the background and development of a new and easy-to-use program for data processing and analysis from experiments run on vertical gallium nitride power devices. Current vertical structures fall short in critical performance metrics, such as On-Resistance and Breakdown Voltage, due to poor management of the device’s electric field. Junction termination extensions, or JTEs, are a field management technique that increases a device’s resilience to expected failure modes by controlling its surface electric fields. Each JTE design requires significant experimental validation, consisting of hundreds of tested devices, each outputting an enormous set of data points. The new software includes multiple methods of filtering large sets of device testing data to identify and remove flawed devices, automate device analyses, and provide statistical breakdowns for four metrics used to define the effectiveness of the JTE and the current carrying capacity of the device. These results can then be related back to fabrication techniques and device design, and in the future, be combined with processing simulations to further improve our understanding of the JTE mechanisms.

97 MATHEMATICS AND COMPUTING↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Factors Influencing Gas Evolution from High‐Nickel Layered Oxide Cathodes in Lithium‐Based Batteries

Abstract Gas evolution from high‐nickel layered oxide cathodes (>90% Ni) remains a major issue for their practical application. Gaseous species, such as CO 2 , O 2 , and CO, that are evolved at high states of charge (SOC) worsen the overall safety of batteries, as pressure build‐up within the cell may lead to cell rupture. Since these gasses are produced during cathode degradation, tracking the formation of gasses is also important in diagnosing cathode failure. Online electrochemical mass spectrometry (OEMS) is a powerful in situ technique to study gas evolution from the cathode during high‐voltage charge. However, the differences in the OEMS experimental setups between different groups make it challenging to compare results between groups. In this perspective, the various factors that influence gas evolution based on the OEMS results collected in this group are presented. The focus is on the conditions that lead to gas release, with a particular emphasis on reactive oxygen formation and subsequent chemical reactions with the electrolyte. Promising strategies, such as electrolytes, compositional tuning, and surface coatings that are effective at suppressing gas evolution from the cathode are highlighted. Critical insights into mitigating cathode degradation and gas evolution are provided to guide the development of safer, high‐energy batteries.

Chemistry↗

GPS signal loss in the wide area monitoring system: Prevalence, impact, and solution

The phasor measurement unit (PMUs), equipped with Global Positioning System (GPS) receivers for precise time synchronization, provides measurements of voltage and current phasors at different nodes of the wide area monitoring system. However, GPS receivers are likely to lose satellite signals due to various unpredictable factors. The prevalence of GPS signal loss (GSL) on PMUs is first investigated using real PMU data. The historical GSL events are extracted from a phasor data concentrator (PDC) and FNET/GridEye server. The correlation between GSL and time, spatial location, solar activity are explored via comprehensive statistical analysis. Furthermore, the impact of GSL on phasor measurement accuracy has been studied via experiments. Finally, several potential solutions to mitigate the impact of GSL on PMUs are discussed and compared.

47 OTHER INSTRUMENTATION↗

Mechanistic Insights into the Interplay between Ion Intercalation and Water Electrolysis in Aqueous Batteries

Improving electrolyte stability to suppress water electrolysis represents a basic principle for designing aqueous batteries. Herein, we investigate counterintuitive roles that water electrolysis plays in regulating intercalation chemistry. Using the Na x Fe[Fe(CN) 6 ]∥NaTi 2 (PO 4 ) 3 (x < 1) aqueous battery as a platform, we report that high-voltage overcharging can serve as an electrochemical activation approach to achieving concurrent Na-ion intercalation and an electrolytic oxygen evolution reaction. When the cell capacity is intrinsically limited by deficient cyclable Na ions, the electrolytic water oxidation on the cathode allows for extra Na-ion intercalation from the electrolyte to the NaTi 2 (PO 4 ) 3 anode, leading to a major increase in cyclable Na ions and specific capacity. Furthermore, the parasitic oxygen generation and potential transition-metal dissolution, as proved by our synchrotron and imaging tools, can be significantly mitigated with a simple reassembling approach, which enables stable electrochemical performance and sheds light on manipulating ion intercalation and water electrolysis for battery fast charging and recycling.

25 ENERGY STORAGE↗

Systems-level investigation of aqueous batteries for understanding the benefit of water-in-salt electrolyte by synchrotron nanoimaging

Water-in-salt (WIS) electrolytes provide a promising path toward aqueous battery systems with enlarged operating voltage windows for better safety and environmental sustainability. In this work, a new electrode couple, LiV 3 O 8 -LiMn 2 O 4 , for aqueous Li-ion batteries is investigated to understand the mechanism by which the WIS electrolyte improves the cycling stability at an extended voltage window. Operando synchrotron transmission x-ray microscopy on the LiMn 2 O 4 cathode reveals that the WIS electrolyte suppresses the mechanical damage to the electrode network and dissolution of the electrode particles, in addition to delaying the water decomposition process. Because the viscosity of WIS is notably higher, the reaction heterogeneity of the electrodes is quantified with x-ray absorption spectroscopic imaging, visualizing the kinetic limitations of the WIS electrolyte. This work furthers the mechanistic understanding of electrode–WIS electrolyte interactions and paves the way to explore the strategy to mitigate their possible kinetic limitations in three-dimensional architectures.

36 MATERIALS SCIENCE↗

Current State of the Electrodynamic Dust Shield for Mitigation

The Electrodynamic Dust Shield (EDS) has been developed as a means to lift, transport and remove dust from surfaces for over 18 years in the Electrostatics and Surface Physics Laboratory at NASA Kennedy Space Center. Resent advances in the technology have allowed large-scale EDSs to be fabricated using roll-to-roll techniques for quick efficient processing. The aim of the current research is to demonstrate the 3-dimensional (3-D) version of the EDS and its applicability to various surfaces of interest throughout the Artemis program that require dust mitigation. The conventional two dimensional (2-D) EDS has been comprised of interdigitated electrodes across a surface of alternating polarity to setup non-uniform electric fields in the location of interest for which the particles need to be removed. The 2-D system can be designed to accommodate various phases. For example, the two phase EDS is comprised of two electrodes 180˚ out of phase, while the 3-phase EDS is 120˚ out of phase with the adjacent leg. 4-phase EDS configurations are also possible but for each square wave a high voltage signal is applied to each leg.

Buhler, C. R.↗

How Successful Site Preparation Work at a Large, Commercial, Hazardous and Toxic Waste Site Can Benefit DOE Cleanup Projects - 18111

Jacobs recently completed site preparation work supporting the private commercial development of a world-scale petrochemical complex (an 'ethylene cracker' to produce the primary building block for many forms of plastic) in Monaca, Pennsylvania - the first major U.S. project of its kind outside the Gulf Coast region in 20 years and one of the largest (multi-billion dollar) construction projects in the eastern U.S. Prior to beginning construction on the petrochemical complex, the site's previous large, industrial zinc smelter operations had to be decommissioned and the facilities had to be removed. During the previous 80 years, the smelting operations at the site were used to produce zinc, lead, mercury, and sulfuric acid (a by-product of smelting). The smelting operations left landfills and industrial soil over a large area that had to be removed or closed under regulatory review to allow development across the 81,000 m{sup 2} (200-acre) industrial site located near a major river and local populations. In order to meet Pennsylvania's site-specific Land Recycling Program (commonly referred to as 'Act 2') legislative requirements, the direct contact pathway for landfill soil and slag was removed or mitigated. The site preparation work, or 'Early Works', started in January 2015. As the selected Early Works overall Engineering, Procurement, and Construction Management (EPCM) contractor, Jacobs performed the front end engineering and design. Subsequently, Jacobs had overall responsibility for procurement, construction management, health and safety, quality, security, and environmental services for the entire site and all contractors. The Early Works project included eight separate work scope packages: 1) Site Preparation, 2) Site Development, 3) Marine Works, 4) Rail Works, 5) Road Works and Offsite Utilities, 6) Site Security, 7) Construction Facilities, and 8) High Voltage Line Relocation. The Early Works scope was successfully completed in 2017. The challenges faced by this privately funded commercial project have much in common with large DOE and government construction projects. This paper explores lessons learned from the project and compares how project challenges were addressed on this private commercial project with those anticipated at large DOE/government construction and remediation sites, particularly those in the areas of Safety, Logistics, Infrastructure, and Stakeholder Involvement. The identification of best practices demonstrated on this successful project are shared for the purpose of bringing outside, commercial perspectives to ongoing or planned DOE/government construction projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stationary Oxygen Vacancy Construction toward a Superior-Performance Ultrahigh Nickel Single-Crystal Cathode

Oxygen vacancies exert a complex and profound influence on the layered cathodes, especially those with ultrahigh nickel content. They can facilitate lithium-ion transport and enhance electronic conductivity, while aggressive oxygen vacancy formation causes structural degradation and electrolyte decomposition. Herein, taking ultrahigh nickel single-crystal LiNi 0.92 Co 0.06 Mn 0.02 O 2 (SC-Ni92) as a model material, we propose a pinning strategy to harness the benefits of oxygen vacancies while mitigating their detrimental effects. Through a carefully controlled thermal process, both oxygen vacancies and pinning atoms are successfully introduced into the surface region. The resulting anchored oxygen vacancies, capitalizing on their inherent advantages, improve conductivity and lithium-ion diffusion. Simultaneously, the neighboring pinning atoms effectively increase the migration barrier and suppress the adverse effects of these vacancies, including electrolyte decomposition and structural degradation during long-term electrochemical cycling. Consequently, oxygen vacancy-anchored single-crystal LiNi 0.92 Co 0.06 Mn 0.02 O 2 (SC-Ni92-OV) demonstrates significantly improved high-voltage electrochemical performance, with 86.16% capacity retention after 200 cycles at 4.6 V and 1 C in a half-cell and 90.71% after 300 cycles at 4.5 V and 1 C in a full cell. Furthermore, this study not only provides valuable insights into the chemistry of oxygen vacancy but also introduces a viable strategy for leveraging oxygen vacancies to achieve stable high-voltage performance in ultrahigh nickel single-crystal cathodes.

defects in solids↗