Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Interband cascade light-emitting diodes grown on silicon substrates using GaSb buffer layer

Interband cascade light-emitting diodes (ICLEDs) offer attractive advantages for infrared applications, which would greatly expand if high-quality growth on silicon substrates could be achieved. Here, this work describes the formation of threading dislocations in ICLEDs grown monolithically on GaSb-on-Silicon wafers. The epitaxial growth is done in two stages: the GaSb-on-Silicon buffer is grown first, followed by the ICLED growth. The buffer growth involves the nucleation of a 10-nm-thick AlSb buffer layer on the silicon surface, followed by the GaSb growth. The AlSb nucleation layer promotes the formation of 90° and 60° interfacial misfit dislocations, resulting in a highly planar morphology for subsequent GaSb growth that is almost 100% relaxed. The resulting GaSb buffer for growth of the ICLED has a threading dislocation density of ~10 7 /cm 2 after ~3 μm of growth. The fabricated LEDs showed variations in device performance, with some devices demonstrating comparable light–current–voltage curves to those for devices grown on GaSb substrates, while other devices showed somewhat reduced relative performance. Cross-sectional transmission electron microscopy observations of the inferior diodes indicated that the multiplication of threading dislocations in the active region had most likely caused the increased leakage current and lower output power. Enhanced defect filter layers on the GaSb/Si substrates should provide more consistent diode performance and a viable future growth approach for antimonide-based ICLEDs and other infrared devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic order in nanogranular iron germanium (Fe 0.53 Ge 0.47 ) films

We study the effect of strain on the magnetic properties and magnetization configurations in nanogranular Fe x Ge 1-x films (x = 0.53 ± 0.05) with and without B20 FeGe nanocrystals surrounded by an amorphous structure. Relaxed films on amorphous silicon nitride membranes reveal a disordered skyrmion phase while films near and on top of a rigid substrate favor ferromagnetism and an anisotropic hybridization of Fe d levels and spin-polarized Ge sp band states. The weakly coupled topological states emerge at room temperature and become more abundant at cryogenic temperatures without showing indications of pinning at defects or confinement to individual grains. These results demonstrate the possibility to control magnetic exchange and topological magnetism by strain and inform magnetoelasticity-mediated voltage control of topological phases in amorphous quantum materials.

36 MATERIALS SCIENCE↗

Study of Plasma Radiation Shielding

The Plasma Radiation Shield is an active device using free electrons, electric and magnetic fields for the purpose of shielding astronauts from energetic solar flare-produced protons. The concept of Plasma Radiation Shielding is reviewed in the light of current studies. The available evidence indicates that the concept is physically sound, but important practical questions remain in at least two areas: these have to do with establishment and control of the extremely high voltages required, and with integration of the concept into a realistic space vehicle design.

Source record↗

The dc-to-dc converters employing staggered-phase power switches with two-loop control

A switched inductor voltage is coupled to a sense winding in each phase, and all sense windings are connected in series to one of two feedback loops to provide a signal that indicates when one of the power switches is on as the principal determinant of switching instants. A sequencer is triggered each time a pulse generator is triggered to turn on a different power switch in sequence at each switching instant.

Wester, G. W.↗

Instrumentation, data acquisition and reduction for a large spaceborne helium dewar

The data acquisition system monitors five types of transducers: (1) platinum and germanium resistance thermometers; (2) superconducting liquid level indicators for both cryogen tanks; (3) pressure transducers for both tanks; (4) strain gauges at critical structural locations; and (5) flowmeters for monitoring cryogen tank boiloff which are linear voltage output transducers. All the transducers produce a voltage proportional to the parameter they measure; this is routed to a single six and one-half digit voltmeter by way of an 80-channel multiplexer. The data acquisition program has six main functions: (1) definition and modification of the channels to be stimulated; (2) sensor stimulation and measurement; (3) raw data storage; (4) raw data conversion; (5) real-time formatting and output of raw or converted data; and (6) editing. The heart of the program is a driver section that represents approximately 20 percent of the code. The driver mode sequences and controls the six main functions.

Brooks, W. F.↗

Cable coupling lightning transient qualification

Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

Cook, M.↗

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗

Fault handling schemes in electronic systems with specific application to radiation tolerance and VLSI design

Naturally occurring space radiation particles can produce transient and permanent changes in the electrical properties of electronic devices and systems. In this work, the transient radiation effects on DRAM and CMOS SRAM were considered. In addition, the effect of total ionizing dose radiation of the switching times of CMOS logic gates were investigated. Effects of transient radiation on the column and cell of MOS dynamic memory cell was simulated using SPICE. It was found that the critical charge of the bitline was higher than that of the cell. In addition, the critical charge of the combined cell-bitline was found to be dependent on the gate voltage of the access transistor. In addition, the effect of total ionizing dose radiation on the switching times of CMOS logic gate was obtained. The results of this work indicate that, the rise time of CMOS logic gates increases, while the fall time decreases with an increase in total ionizing dose radiation. Also, by increasing the size of the P-channel transistor with respect to that of the N-channel transistor, the propagation delay of CMOS logic gate can be made to decrease with, or be independent of an increase in total ionizing dose radiation. Furthermore, a method was developed for replacing polysilicon feedback resistance of SRAMs with a switched capacitor network. A switched capacitor SRAM was implemented using MOS Technology. The critical change of the switched capacitor SRAM has a very large critical charge. The results of this work indicate that switched capacitor SRAM is a viable alternative to SRAM with polysilicon feedback resistance.

Attia, John Okyere↗

Modeling and Simulation of Trapping Mechanisms of Granular Media in Space

This paper describes the modeling and simulation of trapped granular media, within the context of the Granular Imager project. We describe the physics of trapped granular media in space, and the methodologies used to stably confine and shape such a medium using electromagnetic fields. The numerical models have also been validated with results in the literature, obtaining excellent agreement. The results of the numerical tests indicate that it is possible, with structural arrangements of rings and plates at different levels of electrostatic potential, to stably confine one or more charged particles, when driven by voltages that can be modulated in time and space.

Quadrelli, Marco B.↗

Constructing uniform oxygen defect engineering on primary particle level for high-stability lithium-rich cathode materials

Lithium-rich layered cathode materials are considered to be research focus of cathode candidates for next generation lithium-ion batteries due to their high specific capacity and low cost. However, lattice deoxidation associated with elemental migration and internal local shrinkage usually results in deteriorated cyclic performance and notorious voltage attenuation, severely limiting its application. In this paper, we have successfully injected uniform oxygen defects into surface region of Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 primary particles under the high-pressure and weak carbonate environment. Various experimental investigations indicate that the injected robust oxygen defects can not only mitigate detrimental interfacial reactions but also suppress unfavorable lattice variation and particle breakage. More importantly, theoretical calculations unravel the critical roles of oxygen defects in regulating energy band structure for strengthened anionic reversibility. Owing to stabilization effects of unique oxygen defect engineering, the modified Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 cathode has harvested dramatically enhanced electrochemical performance including a high initial coulombic efficiency of 96.6%, an outstanding capacity retention of 91.96% (1C, 200 cycles) and suppressed voltage decay of only 1.62 mV per cycle. Therefore, this facile and effective defect engineering strategy could establish new guidance for promoting practical application of Li-rich Mn-based cathode material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

Juno↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of power generation experiments in the NASA Lewis closed cycle MHD facility

The design and operation of the closed cycle MHD facility is discussed and results obtained in recent experiments are presented. The main components of the facility are a compressor, recuperative heat exchanger, heater, nozzle, MHD channel with 28 pairs of thoriated tungsten electrodes, cesium condenser, and an argon cooler. The facility has been operated at temperatures up to 2100 K with a cesium-seeded argon working fluid. At low magnetic field strengths, the open circuit voltage, Hall voltage and short circuit current obtained are 90, 69, and 47 percent of the theoretical equilibrium values, respectively. Comparison of this data with a wall and boundary layer leakage theory indicates that the generator has shorting paths in the Hall direction.

Sovie, R. J.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers

The experimental paralleling characteristics of two 1200 Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences. However, equilibrium could not be reached in extreme cases where alternator load differences were great and, at the same time, the phase-angle error was large (150 deg or more).

Perz, D. A.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers.

The experimental paralleling characteristics of two 1200-Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based power systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences.

Perz, D. A.↗

Theoretical effects of surface diffused region lifetime models on silicon solar cells

A computer simulation of silicon solar cells has indicated that the combination of band gap reduction due to heavy doping and certain spatial forms of lifetime dependence can combine to form severe limitations on the open-circuit voltage of such cells. The interaction of these effects tends to shift the active region of the diffused surface layer away from the injecting junction, resulting in an increase in the current density injected into the surface region. Reductions in open circuit voltage as great as 10% over models which do not include these effects can be seen.

Dunbar, P. M.↗

1.0 to 2.5 micrometer short wavelength infrared /SWIR/ linear array technology for low background applications

A design concept is presented for a hybrid linear focal plane array operating in the 1.0 to 2.5 micron band under low background conditions such as encountered in spaceborne missions. The concept is based on direct gate coupling of the input from a photovoltaic mercury-cadmium telluride detector into a CCD multiplexer. Theoretical analysis indicates a specific detectivity at peak wavelength on the order of 10 to the 12th cm sq rt Hz/W when the system is operating at 200 K. Values of the voltage responsivity, specific detectivity and the relative voltage noise levels of the coupled system obtained in experimental studies with direct-gate-coupled 4.0-micron detectors support the theoretical analysis performed for the case of system detectivity limited by the CCD 1/f noise.

Stobie, J.↗