Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vibration testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cryogenic star-tracking telescope for Gravity Probe B

This paper describes the design, development and preliminary testing of the cryogenic star-tracking telescope used as an optical reference for the gyroscopes in the Gravity Probe B Relativity Gyroscope experiment. The telescope is operated at 1.8 K; it is fabricated entirely from fused quartz components held together by optical contacting; it has a physical length of 14 in., a focal length of 150 in. and an aperture of 5.6 in. Readout is by two photomultiplier chopper-detector assemblies at ambient satellite temperature. When fully operational, the telescope may be expected to have a precision approaching 0.1 milliarcsec over a linear range of 70 + or 70 milliarcsec. Its projected noise performance corresponds to an angular resolution of 1 milliarcsec in 1 Hz bandwidth. The paper includes a theoretical analysis, a description of the design and fabrication of a laboratory version of the telescope, a discussion of techniques of optical contacting, an account of vibration tests on a separate mass model of the telescope, a description of the artificial star developed for optical tests, and an account of preliminary experimental results.

Everitt, C. W. F.↗

Measurement of damping of graphite epoxy composite materials and structural joints

The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.

Crocker, Malcolm J.↗

Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Characterization of Friction Joints Subjected to High Levels of Random Vibration

This paper describes the test program in detail including test sample description, test procedures, and vibration test results of multiple test samples. The material pairs used in the experiment were Aluminum-Aluminum, Aluminum- Dicronite coated Aluminum, and Aluminum-Plasmadize coated Aluminum. Levels of vibration for each set of twelve samples of each material pairing were gradually increased until all samples experienced substantial displacement. Data was collected on 1) acceleration in all three axes, 2) relative static displacement between vibration runs utilizing photogrammetry techniques, and 3) surface galling and contaminant generation. This data was used to estimate the values of static friction during random vibratory motion when "stick-slip" occurs and compare these to static friction coefficients measured before and after vibration testing.

aluminum↗

A power-spectral-density computer program

Computer program simplifies and clarifies random noise vibration test results. It also varies PSD test specifications, sets up automatic equalization equipment, and calculates an exact accleration level for the random noise prior to the test.

Chapman, C. P.↗

Vibration damping composition has flush-away feature

Vibration damping compound nullifies resonant frequencies in structures that support critical components undergoing vibration testing. The main feature of this damping composition is the ability to remove it with a flush of plain tap water.

Fellin, J. F.↗

Shaker slip-plate adapter

Magnesium adapter ties in all of the attachment bosses on a horizontal slip table and makes a rigid coupling which terminates in a single row of attachment bosses at the edge of the horizontal plate. This eliminates ineffective dissipation of the driving force in vibration tests.

Holm, O. S.↗

Portable vibration exciter

Gas-driven vibration exciter produces a sinusoidal excitation function controllable in frequency and in amplitude. It allows direct vibration testing of components under normal loads, removing the possibility of component damage due to high static pressure.

Beecher, L. C.↗