Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value stacking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY12 Status Report

Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory methods. This document is a progress report for FY2012 PNNL analysis and algorithm development. Progress made by PNNL in FY2012 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel assemblies. PNNL further refined the semi-empirical model developed in FY2011 based on singular value decomposition (SVD) to numerically account for the effects of self-shielding. The average uncertainty in the Pu mass across the NGSI-64 fuel assemblies was shown to be less than 3% using only six calibration assemblies with a 2% uncertainty in the isotopic masses. When calibrated against the six NGSI-64 fuel assemblies, the algorithm was able to determine the total Pu mass within <2% uncertainty for the 27 diversion cases also developed under NGSI. Two purely empirical algorithms were developed that do not require the use of Pu isotopic fission chambers. The semi-empirical and purely empirical algorithms were successfully tested using MCNPX simulations as well applied to experimental data measured by RPI using their LSDS. The algorithms were able to describe the 235U masses of the RPI measurements with an average uncertainty of 2.3%. Analyses were conducted that provided valuable insight with regard to design requirements (e.g. Pb stack size, neutron source location) of an LSDS for the purpose of assaying used fuel assemblies. Sensitivity studies were conducted that provide insight as to how the LSDS instrument can be improved by making it more sensitive to the center of the fuel assemblies. In FY2013, PNNL will continue efforts to develop and refine design requirements of an LSDS for the ultimate purpose of assaying used fuel assemblies. Future efforts will be directed toward more extensive experimental benchmarking of currently implemented time-spectra analysis algorithms.

Kulisek, Jonathan A.↗

Investigating high-energy proton-induced reactions on spherical nuclei: Implications for the preequilibrium exciton model

A number of accelerator-based isotope production facilities utilize $100-200$ MeV proton beams due to the high production rates enabled by high-intensity beam capabilities and the greater diversity of isotope production brought on by the long range of high-energy protons. However, nuclear reaction modeling at these energies can be challenging because of the interplay between different reaction modes and a lack of existing guiding cross section data. A Tri-lab collaboration has been formed between the Lawrence Berkeley, Los Alamos, and Brookhaven National Laboratories to address these complexities by characterizing charged-particle nuclear reactions relevant to the production of established and novel radioisotopes. In the inaugural collaboration experiments, stacked-targets of niobium foils were irradiated at the Brookhaven Linac Isotope Producer ($E_p=200$ MeV) and the Los Alamos Isotope Production Facility ($E_p=100$ MeV) to measure $^{93}$Nb(p,x) cross sections between $50-200$ MeV. The results were compared with literature data as well as the default calculations of the nuclear model codes TALYS, CoH, EMPIRE, and ALICE. The default code predictions largely failed to reproduce the measurements. Therefore, we developed a standardized procedure, which determines the reaction model parameters that best reproduce the most prominent reaction channels in a physically justifiable manner. Overall, the primary focus of the procedure was to determine the best parameterization for the pre-equilibrium two-component exciton model. This modeling study revealed a trend towards a relative decrease for internal transition rates at intermediate proton energies ($E_p=20-60$ MeV) in the current exciton model as compared to the default values. The results of this work are instrumental for the planning, execution, and analysis essential to isotope production.

43 PARTICLE ACCELERATORS↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

ON THE FORMATION TIMESCALE OF MASSIVE CLUSTER ELLIPTICALS BASED ON DEEP NEAR-INFRARED SPECTROSCOPY AT z {approx} 2

We present improved constraints on the formation timescale of massive cluster galaxies based on rest-frame optical spectra of galaxies in a forming cluster located at z = 2.16. The spectra are obtained with MOIRCS on the Subaru Telescope with an integration time of {approx}7 hr. We achieve accurate redshift measurements by fitting spectral energy distributions using the spectra and broadband photometry simultaneously, allowing us to identify probable cluster members. Clusters at low redshifts are dominated by quiescent galaxies, but we find that quiescent galaxies and star-forming galaxies coexist in this z = 2 system. Interestingly, the quiescent galaxies form a weak red sequence in the process of forming. By stacking the spectra of star-forming galaxies, we observe strong emission lines such as [O II] and [O III] and we obtain a tentative hint of active galactic nucleus activities in these galaxies. On the other hand, the stacked spectrum of the quiescent galaxies reveals a clear 4000 A break with a possible Ca II H+K absorption feature and strong emission lines such as [O II] are absent in the spectrum, confirming the quiescent nature of these galaxies. We then perform detailed spectral analyses of the stacked spectrum, which suggest that these massive quiescent galaxies formed at redshifts between 3 and 4 on a timescale of {approx}< 0.5 Gyr. This short formation timescale is not reproduced in recent numerical simulations. We discuss possible mechanisms for how these galaxies form 10{sup 11} M{sub Sun} stellar mass on a short timescale and become red and quiescent by z = 2.

79 ASTRONOMY AND ASTROPHYSICS↗

A MULTI-WAVELENGTH VIEW OF THE STAR FORMATION ACTIVITY AT z {approx} 3

We present a multi-wavelength, UV-to-radio analysis for a sample of massive (M{sub *} {approx} 10{sup 10} M{sub sun}) IRAC- and MIPS 24 {mu}m detected Lyman break galaxies (LBGs) with spectroscopic redshifts z {approx} 3 in the GOODS-North field. For LBGs without individual 24 {mu}m detections, we employ stacking techniques at 24 {mu}m, 1.1 mm, and 1.4 GHz to construct the average UV-to-radio spectral energy distribution and find it to be consistent with that of a luminous infrared galaxy with L{sub IR} = 4.5{sup +1.1}{sub -2.3} x 10{sup 11} L{sub sun} and a specific star formation rate of 4.3 Gyr{sup -1} that corresponds to a mass doubling time {approx}230 Myr. On the other hand, when considering the 24 {mu}m detected LBGs we find among them galaxies with L{sub IR}>10{sup 12} L{sub sun}, indicating that the space density of z {approx} 3 UV-selected ultra-luminous infrared galaxies (ULIRGs) is {approx}(1.5 {+-} 0.5) x 10{sup -5} Mpc{sup -3}. We compare measurements of star formation rates from data at different wavelengths and find that there is tight correlation (Kendall's {tau}>99.7%) and excellent agreement between the values derived from dust-corrected UV, mid-IR, millimeter, and radio data for the whole range of L{sub IR} up to L{sub IR} {approx} 10{sup 13} L{sub sun}. This range is greater than that for which the correlation is known to hold at z {approx} 2, possibly due to the lack of significant contribution from polycyclic aromatic hydrocarbons to the 24 {mu}m flux at z {approx} 3. The fact that this agreement is observed for galaxies with L{sub IR}>10{sup 12} L{sub sun} suggests that star formation in UV-selected ULIRGs, as well as the bulk of star formation activity at this redshift, is not embedded in optically thick regions as seen in local ULIRGs and submillimeter-selected galaxies at z = 2.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiochemical study of the kinematics of multi-nucleon transfer reactions in 48 Ca + 248 Cm collisions 10% above the Coulomb barrier

In this paper, the kinematics of multi-nucleon transfer reactions in 48 Ca + 248 Cm collisions at 262 MeV (center of target) was investigated by using a stacked-foil technique and radiochemical separations of trans-curium elements. Trans-curium isotopes were identified by α-particle spectroscopy. For Fm isotopes, by comparing the centroids of the measured post-neutron emission isotope distributions with the most probable primary mass number predicted by Volkov's generalized Q g g systematics, the missing mass (number of evaporated neutrons) is estimated. The latter is compared with that deduced from the measured centroid of the laboratory angular distribution peaked closely to the grazing angle and the centroid of the range distribution, being used to determine the average total kinetic energy loss (TKEL) and the average excitation energy. The latter agrees within the uncertainties with the missing mass so that a consistent picture of the reaction mechanism emerges. For products closer to the target Z, e.g., Cf and Bk, the distributions of kinetic energies are much broader than for Fm, reflecting the fact that in the former, values of TKEL reach from quasi-elastic scattering all the way to deep inelastic scattering. Finally, the measured laboratory angular distribution and the average laboratory kinetic energy of the Fm isotopes, being the prototypes for multi-nucleon transfer products, are benchmark values for the design of electromagnetic separators to be constructed for the separation and detection of unknown neutron-rich transactinides produced in this nuclear reaction type.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Eastern Kodak Company

Lighting consumes more than 20% of electricity generated in the United States. Solid state lighting relies upon either inorganic or organic light-emitting diodes (OLEDs). OLED devices because of their thinness, fast response, excellent color, and efficiency could become the technology of choice for future lighting applications, provided progress is made to increase power efficiency and device lifetime and to develop cost-effective manufacturing processes. As a first step in this process, Eastman Kodak Company has demonstrated an OLED device architecture having an efficacy over 50 lm/W that exceeds the specifications of DOE Energy Star Program Requirements for Solid State Lighting. The project included work designed to optimize an OLED device, based on a stacked-OLED structure, with performance parameters of: low voltage; improved light extraction efficiency; improved internal quantum efficiency; and acceptable lifetime. The stated goal for the end of the project was delivery of an OLED device architecture, suitable for development into successful commercial products, having over 50 lum/W power efficiency and 10,000 hours lifetime at 1000 cd/m{sup 2}. During the project, Kodak developed and tested a tandem hybrid IES device made with a fluorescent blue emitter, a phosphorescent yellow emitter, and a phosphorescent red emitter in a stacked structure. The challenge was to find low voltage materials that do not absorb excessive amounts of emitted light when the extraction enhancement structure is applied. Because an extraction enhancement structure forces the emitted light to travel several times through the OLED layers before it is emitted, it exacerbates the absorption loss. A variety of ETL and HTL materials was investigated for application in the low voltage SSL device structure. Several of the materials were found to successfully yield low operating device voltages without incurring excessive absorption loss when the extraction enhancement structure was applied. An internal extraction layer comprises two essential components: a light extraction element (LEE) that does the actual extraction of emitted light and a light coupling layer (LCL) that allows the emitted light to interact with the extraction element. Modeling results show that the optical index of the LCL needs to be high, preferably higher than that of the organic layers with an n value of {approx}1.8. In addition, since the OLED structure needs to be built on top of it the LCL needs to be physically and chemically benign. As the project concluded, our focus was on the tandem hybrid device, which proved to be the more efficient architecture. Cost-efficient device fabrication will provide the next challenges with this device architecture in order to allow this architecture to be commercialized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GAS MOTION STUDY OF Ly{alpha} EMITTERS AT z {approx} 2 USING FUV AND OPTICAL SPECTRAL LINES {sup ,}

We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopy for five Ly{alpha} emitters (LAEs) at z {approx_equal} 2.2 for which high-resolution FUV spectra from Magellan/MagE are available. We detect nebular emission lines including H{alpha} on the individual basis and low-ionization interstellar (LIS) absorption lines in a stacked FUV spectrum, and measure average offset velocities of the Ly{alpha} line, {Delta}v {sub Ly{alpha}}, and LIS absorption lines, {Delta}v {sub abs}, with respect to the systemic velocity defined by the nebular lines. For a sample of eight z {approx} 2-3 LAEs without active galactic nucleus from our study and the literature, we obtain {Delta}v {sub Ly{alpha}} = 175 {+-} 35 km s{sup -1}, which is significantly smaller than that of Lyman-break Galaxies (LBGs), {Delta}v {sub Ly{alpha}} {approx_equal} 400 km s{sup -1}. The stacked FUV spectrum gives {Delta}v {sub abs} = -179 {+-} 73 km s{sup -1}, comparable to that of LBGs. These positive {Delta}v {sub Ly{alpha}} and negative {Delta}v {sub abs} suggest that LAEs also have outflows. In contrast to LBGs, however, the LAEs' {Delta}v {sub Ly{alpha}} is as small as |{Delta}v {sub abs}|, suggesting low neutral hydrogen column densities. Such a low column density with a small number of resonant scattering may cause the observed strong Ly{alpha} emission of LAEs. We find an anti-correlation between Ly{alpha} equivalent width (EW) and {Delta}v {sub Ly{alpha}} in a compilation of LAE and LBG samples. Although its physical origin is not clear, this anti-correlation result appears to challenge the hypothesis that a strong outflow, by means of a reduced number of resonant scattering, produces a large EW. If LAEs at z > 6 have similarly small {Delta}v {sub Ly{alpha}} values, constraints on the reionization history derived from the Ly{alpha} transmissivity may need to be revised.

79 ASTRONOMY AND ASTROPHYSICS↗

Fermi-LAT constraints on dark matter annihilation cross section from observations of the Fornax cluster

We analyze 2.8-yr data of 1–100 GeV photons for clusters of galaxies, collected with the Large Area Telescope onboard the Fermi satellite. By analyzing 49 nearby massive clusters located at high Galactic latitudes, we find no excess gamma-ray emission towards directions of the galaxy clusters. Using flux upper limits, we show that the Fornax cluster provides the most stringent constraints on the dark matter annihilation cross section. Stacking a large sample of nearby clusters does not help improve the limit for most dark matter models. This suggests that a detailed modeling of the Fornax cluster is important for setting robust limits on the dark matter annihilation cross section based on clusters. We therefore perform the detailed mass modeling and predict the expected dark matter annihilation signals from the Fornax cluster, by taking into account effects of dark matter contraction and substructures. By modeling the mass distribution of baryons (stars and gas) around a central bright elliptical galaxy, NGC 1399, and using a modified contraction model motivated by numerical simulations, we show that the dark matter contraction boosts the annihilation signatures by a factor of 4. For dark matter masses around 10 GeV, the upper limit obtained on the annihilation cross section times relative velocity is (σν)∼<(2–3) × 10{sup −25} cm{sup 3} s{sup −1}, which is within a factor of 10 from the value required to explain the dark matter relic density. This effect is more robust than the annihilation boost due to substructure, and it is more important unless the mass of the smallest subhalos is much smaller than that of the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Position Paper on Practicable Performance Criteria for the Removal Efficiency of Volatile Radionuclides

As a result of fuel reprocessing, volatile radionuclides may be released from the facility stack if no processes are put in place to remove them. The radionuclides that are of concern in this document are 3 H, 14 C, 85 Kr, and 129 I. The question we attempted to answer is how efficient must this removal process be for each of these radionuclides? To answer this question, we examined the three regulations that may impact the degree to which these radionuclides must be reduced before process gases can be released from the facility. These regulations are 40 CFR 61 (EPA 2010a), 40 CFR 190(EPA 2010b), and 10 CFR 20 (NRC 2012). These regulations apply to the total radionuclide release and to a particular organ - the thyroid. Because these doses can be divided amongst all the radionuclides in different ways and even within the four radionuclides in question, we provided several cases. We first looked at the inventories for these radionuclides for three fuel types (PWR UOX, PWR MOX, and AHTGR), several burn-up values, and time out of reactor extending to 200 y. We calculated doses to the maximum exposed individual (MEI) with the EPA code CAP-88 (Rosnick 1992). Finally, we looked at two dose cases. Allocating all of the allowable dose to be used by the volatile radionuclides is one case, but, perhaps, unrealistic. In lieu of this, we arbitrarily selected a value of 10% of the allowable dose to be assigned to the volatile radionuclides. We calculated the required decontamination factors (DFs) for both of these cases, including the case for the thyroid dose for which 14 C and 129 I were the main contributors. With respect to 129 I doses, we found that the highest dose was calculated with iodine as a fine particulate. The dose scaled as the fraction of the total 129 I that was particulate. Therefore, we assumed for all of our calculations that 100% of the 129 I was particulate and allow the user of the results given here to scale our calculated doses to their needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capacitive Deionization Using Alternating Polarization: Effect of Surface Charge on Salt Removal

Alternating polarization (AP) at ±1.2/0 V is performed on a capacitive deionization stack assembled with carbon xerogel (CX) electrodes. Long-term testing shows enhanced cycling stability without the formation of inversion peaks. AP also leads to an arch-shaped plot of salt adsorption capacity (SAC) versus cycling time, with the highest SAC of approximately 3 mg (NaCl) g −1 (CX) during this long-term test. Characterization of both the freshly prepared and cycled electrodes depict that AP results in surface charge of all the electrodes being modified from positive to negative character. Here by leveraging balances of electronic, surface, and ionic charges in carbon micropores, it is found that a portion of the electronic charge contributes to the ionic charge for salt adsorption, and another portion is parasitically consumed to balance the surface charge during the charge reconciliation process. When the consumption of electronic charge for charge reconciliation becomes minimal, both the positive and negative surface charges are nearly equivalent on the CX electrode. Under such a condition, the highest SAC values can be achieved for AP testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using ChemCam LIBS data to constrain grain size in rocks on Mars: Proof of concept and application to rocks at Yellowknife Bay and Pahrump Hills, Gale crater

Grain size in martian sedimentary rocks can be constrained using point-to-point chemical variabilities in Laser Induced Breakdown Spectroscopy (LIBS) data from the ChemCam instrument on the Mars Science Laboratory (MSL) Curiosity rover. The diameter of each point ablated by the ChemCam laser is in the range of medium to coarse sand in size. Thus, rocks with grains significantly smaller than the laser spot size produce bulk rock compositions at each LIBS point and low point-to-point chemical variability among LIBS points. In contrast, analyses of rocks with grains about the size of the spot or larger contain contributions from individual grains at each point and often have high point-to-point chemical variability. Here the Gini index, a statistical parameter, was used to calculate the point-to-point chemical variability in major-element oxide compositions derived from the ChemCam LIBS data. First, the total range of each LIBS major-element oxide composition was normalized from 0 to 1 across all LIBS observations. Then the Gini index was calculated for each oxide in each LIBS observation. Finally, the Gini indices of each oxide were averaged to derive a Gini index mean score, G MEAN , for each LIBS observation. A correlation between G MEAN and grain size was validated using sedimentary rocks of various grain sizes from the Yellowknife Bay formation and the Pahrump Hills member of the Murray formation in Gale crater. Overall, finer-grained rocks had smaller G MEAN than coarser-grained rocks. To calibrate G MEAN to grain size, grain size estimates based on visual assessment of high-resolution images were compared to G MEAN values for the same targets to create a calibrated scale. This calibrated scale was used to infer the grain size of rocks with unknown grain size. Overall, the grain sizes predicted for rocks with unknown grain size overlapped with those of known grain size from the same units and/or bedrock targets. The grain sizes inferred using the G MEAN based on ChemCam LIBS data are complimentary to those determined from images and both techniques can be used to improve interpretations of the depositional environments of rocks analyzed by Curiosity and future Mars missions with LIBS, such as the Mars 2020 rover.

58 GEOSCIENCES↗

Monitoring the CMS Data Acquisition System

The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for rob ust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is suppor ted in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an app roach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into re gions of collections. An implementation following this scheme is deployed as the monitoring infrastructure of the CMS experiment at the Large Hadron Collider. All services in this distributed data acquisition system are providing standard web service inte rfaces via XML, SOAP and HTTP [15,22]. Continuing on this path we adopted WS-* standards implementing a monitoring system layered on top of the W3C standards stack. We designed a load-balanced publisher/subscriber system with the ability to include high-s peed protocols [10,12] for efficient data transmission [11,13,14] and serving data in multiple data formats.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

β -decay half-lives and β -delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N = 126

Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8 He up to 150 La . Apart from 210 Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150 . Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126 , in order to guide theoretical models and help understand the formation of the third r-process peak at A ~ 195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126 . Method: Ions of interest were produced by fragmentation of a 238 U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3 He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204-206 Au, 208 – 211 Hg, 211 – 216 Tl , 215 – 218 Pb, and 218 – 220 Bi, nine of them for the first time. Neutron emission probabilities are reported for 210, 211 Hg and 211 – 216 Tl . Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. Lastly, the measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution spectroscopy of extremely metal-poor stars from SDSS/Segue. II. Binary fraction

The fraction of binary systems in various stellar populations of the Galaxy and the distribution of their orbital parameters are important but not well-determined factors in studies of star formation, stellar evolution, and Galactic chemical evolution. While observational studies have been carried out for a large sample of nearby stars, including some metal-poor Population II stars, almost no constraints on the binary nature for extremely metal-poor (EMP; [Fe/H] <−3.0) stars have yet been obtained. Here we investigate the fraction of double-lined spectroscopic binaries and carbon-enhanced metal-poor (CEMP) stars, many of which could have formed as pairs of low-mass and intermediate-mass stars, to estimate the lower limit of the fraction of binary systems having short periods. The estimate is based on a sample of very metal-poor stars selected from the Sloan Digital Sky Survey and observed at high spectral resolution in a previous study by Aoki et al. That survey reported 3 double-lined spectroscopic binaries and 11 CEMP stars, which we consider along with a sample of EMP stars from the literature compiled in the SAGA database. We have conducted measurements of the velocity components for stacked absorption features of different spectral lines for each double-lined spectroscopic binary. Our estimate indicates that the fraction of binary stars having orbital periods shorter than 1000 days is at least 10%, and possibly as high as 20% if the majority of CEMP stars are formed in such short-period binaries. This result suggests that the period distribution of EMP binary systems is biased toward short periods, unless the binary fraction of low-mass EMP stars is significantly higher than that of other nearby stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Acidities of MgO surface sites: implications for the formation mechanism of Mg(OH) 2

The hydroxylation of periclase (MgO) to brucite (Mg(OH) 2 ) is thought to be an important intermediate step when using MgO to capture CO 2 from the atmosphere. However, the mechanism of hydroxylation of MgO to form Mg(OH) 2 is poorly understood. In this work, we used atomic-scale density functional tight binding simulations coupled with the metadynamics rare event method to analyze the surface chemistry of MgO and the acid dissociation equilibrium constants (pK a ) of its surface sites. The method and parameters were validated by calculating the pK a for hydroxylation of the first shell water bound to aqueous Mg 2+ ion. The pK a value derived using a probabilistic method was 12.3, which is in fair agreement with the accepted value of 11.4, with the difference between them equal to a ∼5 kJ mol −1 error in the calculations. We then extended these pK a calculations to probe the hydroxylation reactions of the surface sites of the MgO(100)–water interface, arriving at pK a s of 5.4 to deprotonate terminal water molecules bound to the surface magnesium sites (η-OH 2 or 〉MgOH 2 ), and 13.9 to deprotonate hydroxylated bridging oxygen sites (μ 5 -oxo or 〉O). Hydroxide (OH − ) adsorption on the surface was also probed and found to be less thermodynamically favorable than deprotonation of the terminal water molecule. The plausibility of the computed pK a s was verified using an activity-based speciation model and compared to pH measurements of water equilibrated with MgO nanoparticles and single crystals. The model predicted a solution pH of 7.1 when surface sites buffered and the pH of 12.0 when MgO dissolution dominated. These are close to the experimental initial solution pHs of 7–7.5 and the long term pHs of ∼10.5. The similarity suggests that the calculated pK a values from the DFTB+/metadynamics simulations are plausible and that these methods can be a useful tool to probe reaction mechanisms involving covalent bonds.

Adapa, Sai Krishna Reddy [Oak Ridge National Labor↗

Direct comparison of elastic incoherent neutron scattering experiments with molecular dynamics simulations of DMPC phase transitions

Neutron scattering techniques have been employed to investigate 1,2-dimyristoyl-sn-glycero-3- phosphocholine (DMPC) membranes in the form of multilamellar vesicles (MLVs) and deposited, stacked multilamellar-bilayers (MLBs), covering transitions from the gel to the liquid phase. Neutron diffraction was used to characterise the samples in terms of transition temperatures, whereas elastic incoherent neutron scattering (EINS) demonstrates that the dynamics on the sub-macromolecular length-scale and pico- to nano-second time-scale are correlated with the structural transitions through a discontinuity in the observed elastic intensities and the derived mean square displacements. Molecular dynamics simulations have been performed in parallel focussing on the length-, time- and temperature-scales of the neutron experiments. They correctly reproduce the structural features of the main gel-liquid phase transition. Particular emphasis is placed on the dynamical amplitudes derived from experiment and simulations. Two methods are used to analyse the experimental data and mean square displacements. They agree within a factor of 2 irrespective of the probed time-scale, i.e. the instrument utilized. Mean square displacements computed from simulations show a comparable level of agreement with the experimental values, albeit, the best match with the two methods varies for the two instruments. Consequently, experiments and simulations together give a consistent picture of the structural and dynamical aspects of the main lipid transition and provide a basis for future, theoretical modelling of dynamics and phase behaviour in membranes. The need for more detailed analytical models is pointed out by the remaining variation of the dynamical amplitudes derived in two different ways from experiments on the one hand and simulations on the other.

Aoun, Bachir↗