Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is examined, including attenuation for transmission measurement of density and concentration. It was determined that transmission-corrected gamma-ray spectra provide a reliable way to monitor the 235 U concentration of uranyl nitrate solution in transfer pipes in NUCPs. Furthermore, existing predictive and analysis methods are adequate to design and realize practical designs. The 137 Cs transmission source employed in this work is viable but not optimal for 235 U densitometry determination. Validated simulations assessed the viability of 133 Ba and 57Co as alternative densitometry sources. All three gamma-ray detectors are viable for monitoring natural uranium feed; although high-purity germanium is easiest to interpret, it is, however, the least attractive as an installation instrument. Overall, for monitoring throughput in a facility such as UNCLE, emulating the uranium concentration and pump speeds of the Springfields conversion facility in the United Kingdom, an uncertainty of less than 0.17% is required in order to detect the diversion of 1 SQ of uranyl nitrate through changes in uranium concentration over an accountancy period of one year with a detection probability of 50%. As a result, calibrated gamma-ray detection systems are capable of determining the concentration of uranium content in NUCPs, it is only in combination with verifiable operator declarations and supporting data, such as flow rate and enrichment, that safeguards conclusions can be drawn.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling and experimental validation of a W f /W-fabrication by chemical vapor deposition and infiltration

Tungsten (W) has a unique combination of excellent thermal properties, low sputter yield, low hydrogen retention, and acceptable activation. Therefore, W is presently the main candidate for the first wall material in future fusion devices. However, its intrinsic brittleness and its further embrittlement during operation bears the risk of a sudden and catastrophic component failure. As a countermeasure, tungsten fiber-reinforced tungsten (W f /W) with extrinsic toughening is being developed. A possible synthesis route is chemical vapor deposition (CVD) using heated W fabrics as substrate. The challenge is that the growing CVD-W can isolate domains from precursor access leading to strength-reducing pores. To deepen the process understanding and to optimize the CVD parameters, models were developed with COMSOL Multiphysics and validated experimentally. W deposition rate equations as function of the temperature and the partial pressures of the precursors H 2 and WF 6 were experimentally validated in previous work. In the present article, these equations are applied to obtain partial pressures within the CVD reactor. The results are taken as input for transient simulations in the microscale, in which W coatings, growing onto multiple adjacent W fibers, were simulated via mesh deformation and remeshing. The surface-to-surface contact of the W coatings and the corresponding potential pore formation were simulated by implementing sophisticated deposition rate stop conditions. Within the measuring uncertainties of ≃ ±1%, the models are validated successfully by experimental comparison regarding the deposition rate, pore structure, and relative densities ranging from 0.6 to 0.9.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SMR safety through HTTF modeling and benchmark efforts for code validation for gas-cooled reactor applications

Accurate modeling and simulation tools for thermal-hydraulics calculations are a key element needed to design and license new advanced reactors including Small Modular Reactors (SMR) and Microreactors. Uncertainties in modeling and simulation can have significant safety and economic implications. The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled prismatic-block nuclear reactors. High-quality measurement data is available from the HTTF that is suitable for a thermal-hydraulics code validation benchmark for gas-cooled reactor simulations. Here, this paper summarizes individual HTTF modeling efforts to date for tool validation at Idaho National Laboratory (INL), Argonne National Laboratory (ANL), Oregon State University (OSU) and Canadian Nuclear Laboratories (CNL) using system thermal-hydraulics codes, Computational Fluid Dynamics (CFD) codes and system-CFD code couplings. Also, the paper introduces the ongoing OECD Nuclear Energy Agency (NEA) High Temperature Gas Reactor Thermal-Hydraulics (HTGR T/H) benchmark that allows for better comparisons of results between different international modeling teams. The benchmark provides well defined computational problems that include code-to-code comparisons and comparisons to measured data. These problems provide an avenue for quantifying accuracy and identifying sources of uncertainty in thermal-hydraulics calculations, including in measured thermophysical properties, as part of validation for gas-cooled reactor simulation tools.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A crisis for the verification and validation of turbulence simulations

Three algorithms have been proposed for solution of the Rayleigh–Taylor turbulent mixing problem. They are based upon three different physical principles governing the Euler equations for fluid flow. The principles serve to select the physically relevant solution from among many nonunique solutions. The admissibility principle is in dispute. The three different algorithms, expressing the three physical admissibility principles can be formulated in terms of the three energy dissipation rates or the entropy production rates, as selected by the size of the sub grid scale coefficients. These have maximal values or less than maximal values. The resulting solutions are markedly different. We find strong validation evidence that supports the maximum rate principle, based on a review of prior results and on new results presented here. We review experimental data used for validation and sufficient to discriminate among the three. We present a new analysis of this data. We show that the hypothesized long wave length perturbations in the initial conditions are not significant, so that validation can be based on this data in a straight forward manner. One of the algorithms is labeled direct numerical simulation, but is not, and as a consequence, the two algorithms with less than maximal SGS coefficients are variants of one another. Finally recommendations for the numerical modeling of the deflagration to detonation transition in type Ia supernova are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Recommendations for Next-Generation Ground Magnetic Perturbation Validation

Data-model validation of ground magnetic perturbation forecasts, specifically of the time rate of change of surface magnetic field, dB/dt, is a critical task for model development and for mitigation of geomagnetically induced current effects. While a current, community-accepted standard for dB/dt validation exists (Pulkkinen et al., 2013), it has several limitations that prevent more complete understanding of model capability. This work presents recommendations from the International Forum for Space Weather Capabilities Assessment Ground Magnetic Perturbation Working Team for creating a next-generation validation suite. Four recommendations are made to address the existing suite: greatly expand the number of ground observatories used, expand the number of events included in the suite from six to eight, generate metrics as a function of magnetic local time, and generate metrics as a function of activity type. For each of these, implementation details are explored. Limitations and future considerations are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Urban Scaling as Validation for Predictions of Imperviousness From Population

Abstract Strategies for creating quantitative projections for human systems, especially impervious surfaces, are necessary to consider the human drivers of climate and ecosystem change. There are models that generate predictions of how impervious surfaces may change in response to different potential futures, but few tools exist for validating those predictions. We seek to fill that gap. We demonstrate a statistically robust sublinear scaling relationship between population and urban imperviousness across a 15 year history. We show that Integrated Climate and Land‐Use Scenarios (ICLUS) urbanization projections are also consistent with theory. These results demonstrate a theory that can be used to validate other models' predictions of urban growth and land cover change, analogous to the ways in which allometric scaling laws in biology have been used to validate process‐based models of ecosystem composition under different climate scenarios.

54 ENVIRONMENTAL SCIENCES↗

The incongruity of validating quantitative proteomics using western blots

Similar to the age-old reviewer request for quantitative PCR validation of RNA sequencing data, nearly every researcher using proteomics technologies has, at one time or another, been asked by a reviewer to provide “western blot validation” of their mass spectrometry-based protein abundance data. We believe this request demonstrates a lack of awareness amongst the plant biology community about the extraordinary improvements in cost, sensitivity and reliability the field of mass spectrometry-based proteomics has made in recent years. Here, in this study, as a group of experts in different domains of quantitative plant proteomics, we explain why “western blot validation” of quantitative proteomics data is both unnecessary and invalid. Furthermore, we invite our colleagues in the plant science community to update their perception of quantitative mass spectrometry as a sensitive and reliable method of protein identification and quantitation.

Mehta, Devang↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Test methodology for validation of multi-frequency models of renewable energy generators using small-signal perturbations

Providing trustworthy and accurate multi-frequency (or harmonic) models for renewable energy generators (REG) is an ongoing challenge for harmonic studies. There have been effective attempts to propose and design a test device to validate the harmonic models, mainly based on shunt current perturbations. However, using additional devices for perturbations is costly for converter-based test sites. This paper provides the test specifications to extend the application of the grid emulators for voltage perturbations and appropriate harmonic model validation. Besides, the effects of the sequence couplings, initial emissions, and power set-points on the test results have been overlooked in the literature. Considering these effects, this paper proposes a generic test methodology to obtain more accurate models in the sequence domain. The experimental verification of the proposed methodology is demonstrated using a 7 MVA grid emulator for testing of a 2 MVA photo-voltaic converter and a 2 MVA Type 3 wind turbine. This way, the test challenges, specifications, and recommendations are presented using the MW-scale experiments on different REGs. Furthermore, the effects of sequence couplings and initial emissions on the calculation results are investigated and compared. The proposed methodology is applicable for harmonic model validation as well as empirical modelling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Outcomes of WPEC SG47 on "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation"

The Working Party on International Nuclear Data Evaluation Co-operation Subgroup 47 (WPECSG47) entitled "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation" was organised from 2019 and 2022 with the objectives to promote more systematic and wider use of shielding benchmark experiments in nuclear data (ND) and transport code validation and development, to provide feedback on the Shielding Integral Benchmark Archive and Database (SINBAD), and to promote its further development in coordination with the Expert Group on Physics of Reactor Systems (EGPRS). Altogether 9 meetings, the large majority (8) held remotely, were organised during the past 3 years to discuss the experience on the use of SINBAD, evaluation of new benchmarks and improvements to be contributed to the database which was severely neglected and lacking maintenance over the past ← 10+ years. Several proposals for new or updated benchmark evaluation were presented and discussed, such as FNG copper, LLNL pulsed spheres, CIAE iron sphere, KFK 1977 gamma measurements, Rez Fe sphere, ASPIS, ORNL Oxygen broomstick, TIARA and others. Complementing the database with new features was also discussed, for example providing the nuclear data sensitivity profiles more systematically would facilitate and better guide the use of data. Information on the geometry, (radiation source) and materials available in CAD format is expected to allow an easier and less error prone reference for computational model preparation and a potential input to CAD based workflows. Inputs for various transport codes and other benchmark data from participants have been shared via the NEA GitLab which could hopefully in the future evolve and form a bases for critically checked and validated benchmark data. Future development of SINBAD will be monitored by EGPRS and the newly created SINBAD Task Force.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validity of Saha's equation of thermal ionization for negatively charged spherical particles in complex plasmas in thermal equilibrium

The authors have discussed the validity of Saha's equation for the charging of negatively charged spherical particles in a complex plasma in thermal equilibrium, even when the tunneling of the electrons, through the potential energy barrier surrounding the particle is considered. It is seen that the validity requires the probability of tunneling of an electron through the potential energy barrier surrounding the particle to be independent of the direction (inside to outside and vice versa) or in other words the Born's approximation should be valid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large-database cross-verification and validation of tokamak transport models using baselines for comparison

State-of-the-art 1D transport solvers ASTRA and TRANSP are verified, then validated across a large database of semi-randomly selected, time-dependent DIII-D discharges. Various empirical models are provided as baselines to contextualize the validation figures of merit using statistical hypothesis tests. For predicting plasma temperature profiles, no statistically significant advantage is found for the ASTRA and TRANSP simulators over a baseline empirical (two-parameter) model. For predicting stored energy, a significant advantage is found for the simulators over a baseline empirical model based on confinement time scaling. Uncertainty in the results due to diagnostic and profile fitting uncertainties is approximated and determined to be insignificant due in part to the large quantity of discharges employed in the study. Advantages are discussed for validation methodologies like this one that employ (1) large databases and (2) baselines for comparison that are specific to the intended use-case of the model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration and validation of the foundation for a multiphase strength model for tin

In this work, the Common Model of Multi-phase Strength and Equation of State (CMMP) model was applied to tin. Specifically, calibrations of the strength-specific elements of the CMMP foundation were developed with a combination of experiments and theory, and then the model was validated experimentally. The first element of the foundation is a multi-phase analytic treatment of the melt temperature and the shear modulus for the solid phases. These models were parameterized for each phase based on ab initio calculations using the software VASP (Vienna Ab initio Simulations Package) based on density functional theory. The shear modulus model for the ambient phase was validated with ultrasonic sound speed measurements as a function of pressure and temperature. The second element of the foundation is a viscoplastic strength model for the phase, upon which strength for inaccessible higher-pressure phases can be scaled as necessary. The stress–strain response of tin was measured at strain rates of 10 -3 to 3 x 10 3 s -1 and temperatures ranging from 87 to 373 K. The Preston–Tonks–Wallace (PTW) strength model was fit to that data using Bayesian model calibration. For validation, six forward and two reverse Taylor impact experiments were performed at different velocities to measure large plastic deformation of tin at strain rates up to ⁠10 5 s -1 . The PTW model accurately predicted the deformed shapes of the cylinders, with modest discrepancies attributed to the inability of PTW to capture the effects of twinning and dynamic recrystallization. Some material in the simulations of higher velocity Taylor cylinders reached the melting temperature, thus testing the multiphase model because of the presence of a second phase, the liquid. In simulations using a traditional modeling approach, the abrupt reduction of strength upon melt resulted in poor predictions of the deformed shape and non-physical temperatures. With CMMP, the most deformed material points evolved gradually to a mixed solid–liquid but never a fully liquid state, never fully lost strength, stayed at the melt temperature as the latent heat of fusion was absorbed, and predicted the deformed shape well.

36 MATERIALS SCIENCE↗

Validation of galvanomagnetic and thermomagnetic transport measurements using Standard Reference Material 3451

In the “method of four coefficients,” electrical resistivity (ρ), Seebeck coefficient (S), Hall coefficient (RH), and Nernst coefficient (Q) of a material are measured and typically fit or modeled with theoretical expressions based on Boltzmann transport theory to glean experimental insights into features of electronic structure and/or charge carrier scattering mechanisms in materials. Although well-defined and readily available reference materials exist for validating measurements of ρ and S, none currently exists for R H or Q. We show that measurements of all four transport coefficients—ρ, S, R H , and Q—can be validated using a single reference sample, namely, the low-temperature Seebeck coefficient Standard Reference Material® (SRM) 3451 (composition Bi 2 Te 3+x ) available from the National Institute for Standards and Technology (NIST) without the need for inter-laboratory sample exchange. Here, R H and Q data for NIST SRM 3451 reported here for the temperature range 80–400 K complement the data already available for ρ and S and will therefore be of interest to researchers desiring to validate new or existing galvanomagnetic and thermomagnetic transport properties measurement systems.

47 OTHER INSTRUMENTATION↗

Extension of the Advanced Test Reactor Operating Envelope Via Enhanced Reactor Physics Validation Techniques

The Korea Atomic Energy Research Institute is currently in the process of qualifying a low-enriched-uranium fuel element design for the new Ki-Jang Research Reactor (KJRR). As part of this effort, a prototype KJRR fuel element was irradiated in this paper for several operating cycles in the northeast flux trap of the Advanced Test Reactor (ATR) at the Idaho National Laboratory. The KJRR fuel element contained a very large quantity of fissile material (618 g 235 U) in comparison with historical ATR experiment standards (<1 g 235 U), and its presence in the ATR flux trap was expected to create a neutronic configuration that would be well outside of the approved validation envelope for the reactor physics analysis methods used to support ATR operations. Accordingly, it was necessary to conduct an extensive set of new low-power physics measurements in the ATR Critical Facility (ATRC), a companion facility to the ATR, located in an immediately adjacent building and sharing the same fuel storage canal. The new measurements included fission power distributions, reactivity, and measurements related to the calibration of the in-core online instrumentation. The effort was focused on the objective of expanding the validation envelope for the computational reactor physics tools used to support ATR operations and safety analysis to include the planned KJRR irradiation in the ATR and similar experiments that are anticipated in the future. The computational and experimental results have demonstrated that the neutronic behavior of the KJRR fuel element in the ATRC is well understood in terms of its general effects on ATRC core reactivity and fission power distributions and its effects on the calibration of the ATR Lobe Power Calculation and Indication System, as well as in terms of its own internal fission rate distribution and total fission power per unit ATRC core power. Finally, taken as a whole, these results have significantly extended the ATR physics validation envelope, thereby enabling an entire new class of irradiation experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗

On the validity of the Poisson assumption in sampling nanometer-sized aerosols

A Poisson process is traditionally believed to apply to the sampling of aerosols. For a constant aerosol concentration, it is assumed that a Poisson process describes the fluctuation in the measured concentration because aerosols are stochastically distributed in space. Recent studies, however, have shown that sampling of micrometer-sized aerosols has non-Poissonian behavior with positive correlations. The validity of the Poisson assumption for nanometer-sized aerosols has not been examined and thus was tested in this study. Its validity was tested for four particle sizes - 10 nm, 25 nm, 50 nm and 100 nm - by sampling from indoor air with a DMA- CPC setup to obtain a time series of particle counts. Five metrics were calculated from the data: pair-correlation function (PCF), time-averaged PCF, coefficient of variation, probability of measuring a concentration at least 25% greater than average, and posterior distributions from Bayesian inference. To identify departures from Poissonian behavior, these metrics were also calculated for 1,000 computer-generated Poisson time series with the same mean as the experimental data. For nearly all comparisons, the experimental data fell within the range of 80% of the Poisson-simulation values. Essentially, the metrics for the experimental data were indistinguishable from a simulated Poisson process. The greater influence of Brownian motion for nanometer-sized aerosols may explain the Poissonian behavior observed for smaller aerosols. Although the Poisson assumption was found to be valid in this study, it must be carefully applied as the results here do not definitively prove applicability in all sampling situations.

concentration measurement↗

SPITZER INFRARED OBSERVATIONS AND INDEPENDENT VALIDATION OF THE TRANSITING SUPER-EARTH CoRoT-7 b

The detection and characterization of the first transiting super-Earth, CoRoT-7 b, has required an unprecedented effort in terms of telescope time and analysis. Although the star does display a radial-velocity signal at the period of the planet, this has been difficult to disentangle from the intrinsic stellar variability and pinning down the velocity amplitude has been very challenging. As a result, the precise value of the mass of the planet-and even the extent to which it can be considered to be confirmed-has been debated in the recent literature, with six mass measurements published so far based on the same spectroscopic observations, ranging from about 2 to 8 Earth masses. Here we report on an independent validation of the planet discovery using one of the fundamental properties of a transit signal: its achromaticity. We observed four transits of CoRoT-7 b at 4.5 {mu}m and 8.0 {mu}m with the Infrared Array Camera (IRAC) on board the Spitzer Space Telescope in order to determine whether the depth of the transit signal in the near-infrared is consistent with that observed in the CoRoT bandpass, as expected for a planet. We detected the transit and found an average depth of 0.426 {+-} 0.115 mmag at 4.5 {mu}m, which is in good agreement with the depth of 0.350 {+-} 0.011 mmag (ignoring limb darkening) found by CoRoT. The observations at 8.0 {mu}m did not yield a significant detection. The 4.5 {mu}m observations place important constraints on the kinds of astrophysical false positives that could mimic the signal. Combining this with additional constraints reported earlier, we performed an exhaustive exploration of possible blend scenarios for CoRoT-7 b using the BLENDER technique. We are able to rule out the vast majority of false positives, and the remaining ones are found to be much less likely than a true transiting planet. We thus validate CoRoT-7 b as a bona fide planet with a very high degree of confidence, independently of any radial-velocity information. Our Spitzer observations have additionally allowed us to significantly improve the ephemeris of the planet, so that future transits should be recoverable well into the next decade. In its warm phase Spitzer is expected to be an essential tool for the validation, along the lines of the present analysis, of transiting planet candidates with shallow signals from CoRoT as well as from the Kepler mission, including potentially rocky planets in the habitable zones of their parent stars.

79 ASTRONOMY AND ASTROPHYSICS↗