Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “undulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

LCLS Ultrafast Science Instruments:Conceptual Design Report

The Stanford Linear Accelerator Center (SLAC), along with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) facility, which will operate in the wavelength range 1.5 nm - 0.15 nm. This FEL, the Linac Coherent Light Source (LCLS), utilizes the SLAC linac and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac will be used as the source of electrons for the LCLS. The high energy electrons will be transported across the SLAC Research Yard, into a tunnel which will house a long undulator. In passing through the undulator, the electrons will be bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength will be tunable from 1.5 nm to 0.15 nm. The LCLS will include two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing three X-ray instruments in order to exploit the unique scientific capability of this new LCLS facility. The technical objective of the LCLS Ultrafast Science Instruments (LUSI) project is to design, build, and install at the LCLS three hard X-ray instruments that will complement the initial instrument included in the LCLS construction. As the science programs advance and new technological challenges appear, instrumentation needs to be developed and ready to conquer these new opportunities. The LCLS instrument concepts have been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the LUSI project instruments have been identified as meeting the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community.

43 PARTICLE ACCELERATORS↗

NSLS 2007 Activity Report (National Synchrotron Light Source Activity Report 2007)

The National Synchrotron Light Source is one of the world's most productive and cost-effective user facilities. With 2,219 individual users, about 100 more than last year, and a record-high 985 publications, 2007 was no exception. In addition to producing an impressive array of science highlights, which are included in this Activity Report, many NSLS users were honored this year for their scientific accomplishments. Throughout the year, there were major strides in the development of the scientific programs by strengthening strategic partnerships with major research resources and with the Center for Functional Nanomaterials (CFN). Of particular note, the Consortium for Materials Properties Research in Earth Sciences (COMPRES) received renewed funding for the next five years through the National Science Foundation. COMPRES operates four high-pressure NSLS beamlines--X17B2, X17B3, X17C, and U2A--and serves the earth science community as well as the rapidly expanding segment of researchers using high-pressure techniques in materials, chemical, and energy-related sciences. A joint appointment was made between the NSLS and Stony Brook University to further enhance interactions with COMPRES. There was major progress on two key beamline projects outlined in the Five-Year Strategic Plan: the X25 beamline upgrade and the construction of the X9 small angle scattering (SAXS) beamline. The X25 overhaul, which began with the installation of the in-vacuum mini-gap undulator (MGU) in January 2006, is now complete. X25 is once again the brightest beamline for macromolecular crystallography at the NSLS, and in tandem with the X29 undulator beamline, it will keep the NSLS at the cutting edge in this important area of research. Upgrade work associated with the new MGU and the front end for the X9 SAXS beamline--jointly developed by the NSLS and the CFN--also was completed. Beamline X9 will host the SAXS program that currently exists at beamline X21 and will provide new microbeam SAXS capabilities and much-needed beam time for the life sciences, soft condensed matter physics, and nanoscience communities. Looking toward the future, a significant step has been made in expanding the user base and diversifying the work force by holding the first Historically Black Colleges and Universities (HBCU) Professors' Workshop. The workshop, which brought 11 professors to the NSLS to learn how to become successful synchrotron users, concluded with the formation of an HBCU User Consortium. Finally, significant contributions were made in optics and detector development to enhance the utilization of the NSLS and address the challenges of NSLS-II. In particular, x-ray detectors developed by the NSLS Detector Section have been adopted by an increasing number of research programs both at the NSLS and at light sources around the world, speeding up measurement times by orders of magnitude and making completely new experiments feasible. Significant advances in focusing and high-energy resolution optics have also been made this year.

43 PARTICLE ACCELERATORS↗

Matter in Extreme Conditions Instrument - Conceptual Design Report

The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by means of diffraction measurements, measurements of the pressure wave characteristics, in situ probing by x-ray scattering of various types all time resolved. The necessary diagnostics are discussed.

43 PARTICLE ACCELERATORS↗

A Design Report of the Baseline for PEP-X: an Ultra-Low Emittance Storage Ring

Over the past year, we have worked out a baseline design for PEP-X, as an ultra-low emittance storage ring that could reside in the existing 2.2-km PEPII tunnel. The design features a hybrid lattice with double bend achromat (DBA) cells in two arcs and theoretical minimum emittance (TME) cells in the remaining four arcs. Damping wigglers are used to reduce the horizontal emittance to 86 pm-rad at zero current for a 4.5 GeV electron beam. At a design current of 1.5 A, the horizontal emittance increases, due to intrabeam scattering, to 164 pm-rad when the vertical emittance is maintained at a diffraction limited 8 pm-rad. The baseline design will produce photon beams achieving a brightness of 10{sup 22} (ph/s/mm{sup 2}/mrad{sup 2}/0.1% BW) at 10 keV in a 3.5-m conventional planar undulator. Our study shows that an optimized lattice has adequate dynamic aperture, while accommodating a conventional off-axis injection system. In this report, we present the results of study, including the lattice properties, nonlinear dynamics, intra-beam scattering and Touschek lifetime, RF system, and collective instabilities. Finally, we discuss the possibility of partial lasing at soft X-ray wavelengths using a long undulator in a straight section.

43 PARTICLE ACCELERATORS↗

Proposal for the Alignment of the 'Loose End'

The 'loose end' of the girder presents an alignment problem because there is no beam based alignment procedure available to position it. The positioning always depends on the fiducialization of the undulator. A direct way to position the 'loose end' to the next quadrupole is to measure their fiducials in relation to each other. By spanning a wire over a distance of several girders, each undulator and quadrupole can be measured by reading its distance to the wire with a portable wire sensor. The pitch of a girder can be determined by measuring height differences at different points on the girder. To measure the height differences a portable HLS is used. During the measurements of the portable system the permanent Wire Position Monitor and the permanent HLS are used to monitor the interim movements of the girder. After the initial alignment the position of the 'loose end' can be monitored with the permanent systems in relation to the quadrupoles.

43 PARTICLE ACCELERATORS↗

Surface Quality of AMg2 Aluminum Alloy with Ultrafine Grain Structure after Machining. 1. Turning

The influence of cutting on the surface roughness and undulation of AMg2 aluminum alloy with regular and ultrafine grain structure is considered. The quantitative influence of profile filters on its surface roughness and undulation is established, on the basis of 2D parameters. In the machining of materials with ultrafine grain structure, the surface quality is better than for materials with regular grain structure.

42 ENGINEERING↗

A Paris-Edinburgh Cell for High-Pressure and High-Temperature Structure Studies on Silicate Liquids Using Monochromatic Synchrotron Radiation

A Paris-Edinburgh press combined with a multi-channel collimator assembly has been commissioned at the GeoSoilEnviro Center for Advanced Radiation Sources (GSECARS) beamline for monochromatic X-ray scattering, with an emphasis on studying low-Z liquids, especially silicate liquids at high pressure. The Paris-Edinburgh press is mounted on a general-purpose diffractometer, with a pixel array detector mounted on the detector arm. The incident monochromatic undulator beam with energies up to 60 keV is focused both horizontally and vertically to a beam size about 30 × 30 µm. With this setup, background scattering from the surrounding pressure media is completely removed at 2θ angles above 10° for samples larger than 1.05 mm in diameter. Thirty minutes is typically sufficient to collect robust X-ray scattering signals from a 1.6 mm diameter amorphous silicate sample. Cell assemblies for the standard Paris-Edinburgh anvils have been developed and pressures and temperatures up to 7 GPa and 2300 K, respectively, have been maintained steadily over hours. We have also developed a cupped-toroidal Drickamer anvil to further increase pressure and temperature capabilities. The cupped-toroidal Drickamer anvil combines features of a modified Drickamer anvil and the traditional Paris-Edinburgh anvil. Pressures up to 12 GPa have been generated at temperatures up to 2100 K.

58 GEOSCIENCES↗

The earth's gravitational field from the combination of satellite and terrestrial data

This paper reviews techniques and results in the combination of gravimetric and satellite data. The estimation of mean anomalies for use in combination studies is discussed with the location of current gravity material being described. Specific techniques for combination solutions are discussed for various models. These models include those where the gravitational field is represented by a set of potential coefficients, or by a set of discrete blocks distributed on the earth. The potential coefficient solutions compared are those of the SAO Standard Earth II and III, the Goddard Earth Model 4, and a solution by the author. These solutions are compared in terms of coefficients, undulation and anomaly differences, and implied anomaly degree variances. In addition, comparisons were made through terrestrial anomaly comparisons, astrogeodetic undulation comparisons, and orbit fitting tests.

Rapp, R. H.↗

The effect of remote zones on the accuracy of evaluating the Molodensky

An analytical method is presented for determining the error in computing the gravity anomaly from the Molodensky integral if geoidal undulation data in remote zones are neglected. The error is given in terms of the usual degree variance and a set of parameters which are functions only of the size of the area in which undulation data are taken. A numerical calculation using Kaula's degree variances indicates that it is necessary to integrate the Molodensky integral over approximately a hemisphere in order to reduce the effect of neglected data to the order of 1 milligal in the computation of gravity anomaly.

Buglia, J. J.↗

Detailed gravimetric geoid computations in North America

A detailed gravimetric geoid has been computed for the Eastern United States and the Northwestern Atlantic Ocean by combining the Goddard Space Flight Center GEM-8 earth gravity model with the available 15 x 15 arcmin and 1 x 1 deg mean free air surface gravity observations. The short wavelength undulations were computed by applying Stokes' formula to the 15 x 15 arcmin and 1 x 1 deg surface data. The long wavelength undulations were provided by the GEM-8 model. The gravimetric geoid has been compared with Geoceiver derived and astrogeodetically determined geoid heights in the United States and the rms agreement is on the order of 1.5 meters. Excellent agreement in shape has been found between the detailed geoid and geoidal profiles derived from GEOS-III altimeter data in the Northwest Atlantic Ocean.

Marsh, J. G.↗

The influence of the atmosphere on geoid and potential coefficient determinations from gravity data

For the precise computation of geoid undulations the effect of the attraction of the atmosphere on the solution of the basic boundary value problem of gravimetric geodesy must be considered. This paper extends the theory of Moritz for deriving an atmospheric correction to the case when the undulations are computed by combining anomalies in a cap surrounding the computation point with information derived from potential coefficients. The correction term is a function of the cap size and the topography within the cap. It reaches a value of 3.0 m for a cap size of 30 deg, variations on the decimeter level being caused by variations in the topography. The effect of the atmospheric correction terms on potential coefficients is found to be small, reaching a maximum of 0.0055 millionths at n = 2, m = 2 when terrestrial gravity data are considered. The magnitude of this correction indicates that in future potential coefficient determination from gravity data the atmospheric correction should be made to such data.

Rummel, R.↗

Improved ground truth geoid for the GEOS-3 calibration area

The purpose of this investigation is to develop methods and procedures are reported for computing a detailed geoid to be used as geodetic ground truth for the calibration and verification of GEOS-3 altimeter data. The technique developed is based on rectifying the best available detailed geoid so that the rectified geoid will have correct scale, orientation, shape and position with respect to the geocenter. The approach involved the development of a mathematical model based on a second degree polynomial, in rectangular Cartesian coordinates, describing the geoid undulations at the control stations. A generalized least squares solution was obtained for the polynomial which describes the variation of the undulation differences between the control stations geoid and the gravimetric geoid. Three rectified geoid were determined. These geoids correspond to three sets of tracking station data: (1) WFC/C-band data; (2) GSFC/C-band data; and (3) OSU-275 data. The absolute accuracy of these rectified geoids is linearly correlated with the uncertainties of the tracking station coordinates and, to a certain extent, with those of the detailed geoid being rectified.

Mourad, A. G.↗

Mean gravity anomalies and sea surface heights derived from GEOS-3 altimeter data

Approximately 2000 GEOS-3 altimeter arcs were analyzed to improve knowledge of the geoid and gravity field. An adjustment procedure was used to fit the sea surface heights (geoid undulations) in an adjustment process that incorporated cross-over constraints. The error model used for the fit was a one or two parameter model which was designed to remove altimeter bias and orbit error. The undulations on the adjusted arcs were used to produce geoid maps in 20 regions. The adjusted data was used to derive 301 5 degree equal area anomalies and 9995 1 x 1 degree anomalies in areas where the altimeter data was most dense, using least squares collocation techniques. Also emphasized was the ability of the altimeter data to imply rapid anomaly changes of up to 240 mgals in adjacent 1 x 1 degree blocks.

Rapp, R. H.↗

Detailed gravity anomalies from GEOS-3 satellite altimetry data

A technique for deriving mean gravity anomalies from dense altimetry data was developed. A combination of both deterministic and statistical techniques was used. The basic mathematical model was based on the Stokes' equation which describes the analytical relationship between mean gravity anomalies and geoid undulations at a point; this undulation is a linear function of the altimetry data at that point. The overdetermined problem resulting from the excessive altimetry data available was solved using Least-Squares principles. These principles enable the simultaneous estimation of the associated standard deviations reflecting the internal consistency based on the accuracy estimates provided for the altimetry data as well as for the terrestrial anomaly data. Several test computations were made of the anomalies and their accuracy estimates using GOES-3 data.

Gopalapillai, G. S.↗

Comparison of surface and satellite gravity data

Satellite derived potential coefficients (GEM 9) are compared to terrestrial gravity data by degree in terms of coefficient differences and in terms of mean anomaly differences. The root mean square undulation difference (to degree 20) was 9 + or - m and the anomaly difference was + or - 7 mgals with GEM 9 commission errors of + or - 1.7 m and + or - 3.8 mgals. The standard deviations of the GEM 9 implied undulations increased from + or - 4 cm at degree 2 to + or - 53 cm at degree 20. The corresponding values implied by a recent (June 1978) terrestrial 5 deg field were + or - 2.53 m and + or - 0.38 m (at degree 20). Comparisons between Geos-3 altimeter derived anomalies and 1 deg X 1 Deg terrestrial data showed that + or - 6-8 mgals is a reasonable accuracy estimate for the altimeter derived anomalies. Anomalies derived from satellite to satellite tracking data indicate an accuracy of about + or - 6 mgals for the recovery of 5 deg equal area blocks.

Rapp, R. H.↗

Quantum/classical mode evolution in free electron laser oscillators

The problem of oscillator evolution and mode competition in free electron lasers is studied. Relativistic quantum field theory is used to calculate electron wave functions, the angular distribution of spontaneous emission, and the transition rates for stimulated emission and absorption in each mode. The photon rate equation for the weakfield regime is presented. This rate equation is applied to oscillator evolution with a conventional undulator, a two-stage optical klystron, and a tapered undulator. The effects of noise are briefly discussed.

Bosco, P.↗

Contributions of GRM to the ocean topography experiment (TOPEX)

The permanent shape of the sea surface, the time averaged mean sea level, is comprised of: (1) an ellipsoidal component due to the mean mass of a rotating Earth; (2) spatial undulations due to the inhomogeneous distribution of mass in the Earth; and (3) spatial undulations due to permanent ocean currents. The amplitude of the three components are in the ratio 10,000 : 100 : 1 m, the first two components comprising the marine geoid, and the third being the permanent topography of the sea surface.

Stewart, R.↗

The geoid in Kenya

The definition of geoidal undulations is given and after summarizing the methods of determination of the geoid, computed geoidal undulations by some of the methods for several points in Kenya are compared to the results obtained by the satellite gravimetric solutions. Results from astrogeodetic levelling and satellite altimetry show some reasonable agreement with the satellite gravimetric geoids while results by Doppler satellite positioning indicate that good agreement can be obtained if the orthometric heights for the points are adjusted to a uniform system.

Lwangasi, Alphonse S.↗